Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.5 LAccepted-AOC 39 MAHESHMATI BANK COLONI MALDA WEST BENGAL | MALDA | MALDA | WEST BENGAL | 732101 | L1 | Accepted-AOC Agency GITANJALI ELECTRONICS AND ELECTRICALS has stood lowest in the e-tendering process. | |
| 2 | L2₹5.9 L+₹35,982 (6.52%)Rejected-Finance CHAKBHABANI RATHTALA BALURGHAT DAKSHIN DINAJPUR 733101 | BALURGHAT | DAKSHIN DINAJPUR | WEST BENGAL | 733101 | L2 | Rejected-Finance Quoted rate found 2nd Lowest (L2). | |
| 3 | L3₹5.9 L+₹41,038.50 (7.44%)Rejected-Finance CONGRESSPARA BALURGHAT DAKSHIN DINAJPUR | BALURGHAT | DAKSHIN DINAJPUR | WEST BENGAL | L3 | Rejected-Finance Quoted rate found 3rd Lowest (L3). | |
| 4 | Rejected-Technical VILL DANGI P O KHIDIRPUR | - | Rejected-Technical Technically disqualified for required credential(s) / document(s) do not fully satisfy the criteria as required in the relevant e-NIT. |
Tender Value
Refer Docs
EMD Value
₹13,000
Closing Date
2 Jan 2021, 5:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGG (P.W.D), D/DINAJPUR ELEC DIVN
OFFICE OF THE EXECUTIVE ENGINEER (P.W.D), DAKSHIN DINAJPUR ELECTRICAL DIVISION, BALURGHAT Dakshin Dinajpur - 733101
Repairing Court Room of Addl District and Session Judge 1st Court in the 1st floor of Balurghat Criminal Court Building and converting the same into the Child Friendly Court at Balurghat in the D Dinajpur Judiciary-E.I work and SITC of A.C Machines.
2020_WBPWD_309438_1
WBPWD/EE/DDED/e-NIQ-07/2020-21
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
Balurghat
Please refer tender documents
5 documents required · 5 mandatory
₹13,000
9 Feb 2021
24 Dec 2020
4 Jan 2021
26 Dec 2020
2 Jan 2021
26 Dec 2020
120 days
Amount
Supplying and fixing 415V, 63A TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. (Make- L&T)
Supplying and fixing 4 way double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. S&F 12 Nos. 240V, 6-32A SP MCB of Breaking capacity 10kA & C characteristics and 1 No. 240 V, 63A FP MCB Isolator on din rail of the DBs and making inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. (Make- Legrand/ L&T/ Seimens)
Supplying and fixing 2+8 way double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. S&F 8 Nos. 240V, 6-32A SP MCB of Breaking capacity 10kA & C characteristics and 1 No. 240 V, 32A DP MCB Isolator on din rail of the DBs and making inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. (Make: Legrand/ Seimens/ ABB)
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Make- Havells / Polycab / Finolex) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for horizontal run & above false ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Make- Legrand - Arteor / Myrius or Crabtree - Amare) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [PVC Rigid Conduit only for horizontal run & above false ceiling and vertical run concealed] a) Average run 8 mtr
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Make- Havells / Polycab / Finolex) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Make- Legrand - Arteor / Myrius or Crabtree - Amare) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works. (On Board)
Supply & Delivery of 1.1 KV grade 4 core 25 sqmm aluminium armoured PVC/XLPE insulated cable. (Make- Havells / Polycab / RR Kabel / Glostar)
Laying of 4 core 25 sqmm cable on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of 4 core 25 sqmm XLPE/PVC armoured cable.
Finishing the end of 4 core 25 sqmm XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials.
Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch (Make- Legrand - Arteor / Myrius or Crabtree - Amare) without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works with Supply & Fixing bakelite / perspex top cover on existing switch board by Brass screws after making housing for switch by cutting bakelite / perspex cover and making necessary connections as required
(i) 150 mm x 100 mm x 65 mm
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Make- Legrand - Arteor / Myrius or Crabtree - Amare) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Make- Havells / Polycab / Finolex) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required.
(a) 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC
(b) 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC
(c) 2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC
Cutting channel of 40 mm x 40 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works (19 mm dia 3 mm thick polythene pipe without earth continuity wire)
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Make- Anchor / Crabtree) & necy. Connections.
Supply & Fixing 27A, OLP 3+ Starter for A.C Machine with S&F 4 Module M.S. Metal Box and necy. Connection. (Make: ELECTRON)
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Make- Legrand - Arteor / Myrius or Crabtree - Amare), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
(a) 1.5 sqmm
(b) 2.5 sqmm
(c) 4 sqmm
(d) 6 sqmm
Earthing with 50 mm dia GI pipe (ISI-Medium) 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level.
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Connecting the equipments to earth busbar including S & F 6 SWG Solid GI (Hot Dip) wire on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages.
Supply & Delivery 220-240 Volt, 4 Ft. long, 18/20 Watt, Single LED Tube Light fittings complete with all accessories incl. 1 no. 18/20 W LED Tube. (Make-Philips, Cat no.-TMC 501 P 1xT-LED 22W P3241 and MAS LEDtube 1200mm 18W865 T8 I – 2100lm or equivalent make of Crompton)
Supply & Delivery 220-240 Volt, 4 Ft. long, 36/40 Watt, Single LED Tube Light fittings complete with all accessories incl. 2 nos. 18/20 W LED Tube. (Make-Philips, Cat no.-TMC 501 P 2xT-LED 22W P3242 and MAS LEDtube 1200mm 18W865 T8 I – 2100lm or equivalent make of Crompton)
Fixing only single /twin fluorescent light fitting complete with all accessories directly on wall/ceiling/HW round block and suitable size of MS fastener
Lowering and refixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. making necessary disconnection and connection as required.
Supply & Fixing of 220V 9/10 Watt LED bulb on existing angular holder. (Make- Philips / Crompton)
Supply & Fixing 240V, 50 Hz, 450 mm sweep, 1325 RPM wall mounted fan (Make- Orient Electric, Model- Tornado Wall II) on wall by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. Length.
Supply & Delivery of following capacity split type A.C. Machine suitable for operation of 1-Ph, 230 Volt, 50 Hz AC power supply with energy efficient compressor (minimum 3 Star rating) incl. loading & unloading charges with carrying at work site as per direction of EIC.
a) 2.0 Ton (R410 / R32) [Make- Hitachi, Model No. RMZ324HCDO or equivalent model of Blue Star / Daikin]
b) 1.5 Ton (R410 / R32) [Make- Hitachi, Model No. RSNS318HCDO or equivalent model of Blue Star / Daikin]
Supply, Fabrication and Installation of copper refrigeration pipe(1/4' dia & 5/8' dia) line with proper insulation arrangement & S&F 3/4 core 2.5 Sq mm copper wire for connection of indoor unit to outdoor unit incl. drainage pipe(25 mm & 32 mm) as per direction of EIC.
Installation charge of the above-said split type A.C machines with cutting necessary holes on wall/wooden/Iron grill etc. incl. S&F necy. Iron base channel etc. incl. mending good the damages to original finish as required as per direction of EIC.
MILLENNIUM ENGINEERS CO OP SOCIETY LTD
M/S Basak Electrical Repairing House
stage.html
html • 0.05 MB
technical_581287.pdf
PDF • 2.08 MB
techsummary_581287.pdf
PDF • 1.93 MB
finance_581287.pdf
PDF • 0.10 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_581287.pdf
PDF • 10.47 MB
AOC.pdf
PDF • 5.71 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .