| 3 | L3₹36.9 L+₹5.1 L (16.0%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹37.0 L+₹5.2 L (16.4%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹37.2 L+₹5.4 L (17.1%)Rejected-Finance PLOT NO 626 627 GIDC BEHIND GANGOTRI DIARY PORBANDAR 360 577 | PORBANDAR | GUJARAT | 360577 | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
26 Dec 2022, 6:00 pmClosed
Maj Yogender Singh
GE Navy Porbandar Tija Mile Porbandar
PROVN OF INFRASTRUCTURE FOR INSTALLATION OF MOBILE TOWER, ADDITION / ALTERATION OF AED AND ALLIED FACILITIES AT NAE, PROVN OF INTERNAL WIRING INCLUDING FANS AT 100 MEN COMPLEX AND SPECIAL REPAIR TO GEYSERS AT NAVAL BASE UNDER GE NAVY PORBANDAR
2022_MES_564602_1
9152/PBR/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Porbandar
Please refer Tender Documents
7 documents required · 7 mandatory
₹500
Garrison Engineer Navy
₹60,000
Yes
12 Jan 2023
22 Nov 2022
27 Dec 2022
22 Nov 2022
26 Dec 2022
7 Dec 2022
23 Nov 2022 - 6 Dec 2022
Amount
Powder coated aluminium anodised frame for doors, windows, Ventilators and partitions with one or more rebates including necessary joining cleats, glazing clips, rubber neoprene packing, handle, stoppage, locking arrangements etc complete with powder coating of approved colour minimum thickness 50 micron complete all as specified and directed.
Anodised aliminium door shutters, aluminium section weight 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodized aluminium snap beading screws complete all as specified and directed.
5.5 mm thick Sheet glass,ordinary quality and glazing with Aluminium snap beading with rubber Neoprene packing in square exc 0.5 sq. m in each pane complete all as specified and as directed.
5mm thick plain colour PVC sheet in strips & channel feathered at the edges for fixing on Solid PVC Wall Lining, Insulated PVC Wall Lining, and Solid PVC Partitions/fixing in aluminium door inclusive of Solvent Cement and fixing at site complete all as specified and directed.
Solar control film 25 micron reflective type pasted to glass panes as per instructions of manufacturers complete all as specified and as directed.
Mortice lock 2 levers verticle type size 100mm complete all as specified and directed.
Hydraulically aluminium extruded section body door closer regulated designation No. 3 universal type suitable for door shutters of 851 to 1000mm in width and weight between 61 to 80 kg complete all as specified and directed.
Floor door stopper 140mm length aluminium alloy body double tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and as directed.
125mm long aluminium anodized barrel tower bolts of extruded section complete all as specified and directed.
12mm thick toughened glass for door, partition etc. of any size and side portions of toughened glass fixed to wall / floor, joints sealed with clear silicon silicate gel to make water tight, edges with diamond cut including taper drilling to flush the screws / all fitting as required, floor hinges, patch fitting top, bottom and sides, lock and handles, spider joint etc. and floor door spring as per requirement all as specified, required at site by manufacturer instructions and complete all as specified and directed.
Supply, install and testing air cooled split unit air conditioners inverter AC's BEE 5 star rated electric driven single phase, copper tube condensor coil of capacity of 2.0 TR including outdoor unit mounting brackets complete with cordless remote control complete all as specified and directed.
Supply and fix voltage stabilizer single phase 50 cycles AC supply complete with voltmeter and designed for input voltage of 175V to 250V and out put voltage stablised between 215V to 240V of capacity 4 KVA as specified. Make : V Guard / Microtek / Luminous / Livguard.
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and directed.
PVC pipe 20 mm dia heavy duty for drain out condensing water of split AC's including cutting of floor/opening of hole in wall and making good after laying of pipe etc to match the existing surfaces complete all as specified and directed by Engineer-in-Charge.
MCB DB double door TPN 4 Way with 200 Amps rated copper bus bar complete all as specified and directed.
MCB TPN 63 Amps complete all as specified and directed.
MCB SP 5-32 Amps,10 KA breaking capacity 'B' Curve suitable 230 V50 Hz for lighting and other domestic load complete all as specified and directed.
Sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable FRLSH 4 single core of size 10 Sqmm earth continuity conductor of size 10 Sqmm to be drawn through and including PVC casing caping / PVC conduit not less than 32mm dia medium grade complete all as Specified and directed by Engr-in-Charge. Note : Four wires of 10 Sqmm and one wire of 10 Sqmm as earthwire and one run of PVC conduit / casing caping shall be measured as one unit.
Sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable FRLSH 2 single core of size 4 Sqmm earth continuity conductor of size 4 Sqmm to be drawn through and including PVC casing caping / PVC conduit not less than 25mm dia medium grade fixed on walls / roof / floors complete all as Specified and directed by Engr-in-Charge. Note : Two wires of 4 Sqmm and one wire of 4 Sqmm as earthwire and one run of PVC conduit / casing caping shall be measured as one unit.
Supply, install, testing and commissioning Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric underground power cable with stranded aluminium conductor cross sectional area 120 sqmm 3.5 core suitable for working on 1100 Volts, laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed. Note :- Excavation, earthwork, sand cushioning, PCC protection cover, GI pipe shall be measured and paid for separately.
Sheet metal enclosure suitable to accommodate MCCB 125 Amps 4 pole upto 185 sqmm 3.5 core cable complete all as directed by Engineer - in - Charge. Make : L&T cat part No. CM91003OOOO or equivalent model of Schenider / Legrand.
MCCB 125 Amps, 4 pole breaking capacity 25 KA with thermal magnetic release complete all as specified and directed. Make : L&T cat part No. CM90642OOMO or equivalent model of Schenider / Legrand.
Onload change over switch with sheet metal enclosure of capacity 125 Amps 4 pole complete all as directed by Engineer - in - Charge.
Double Walled Corrugated (DWC) HDPE pipe of size 90 mm outer dia and 75 mm inner dia conforming to IS 16205 Part -24 Including necessary bends, coupling, tees, reducers, spacers, end caps, rubber rings etc having pressure rating not less than 450 N through trenches/wall/floor/on pole in any type of soil for protection of electric cable complete all as directed by Engr-In-Charge.
Supply, Install testing & Commissioning of horizontal openwell submersible Pump set of capacity 7.5 HP, Three phase, 415Volts, 21-36 meter Head range including connecting to inlet & outlet and testing complete all as specified and as directed. Make : Lubi / Lirloskar / Pluga / V guard / CRI Pumps. Note: (i) HDPE Suction and delivery line will be measured and paid seprately. (ii) The cost of PCC base in cement concrete 1:2:4 type B1 is deemed to be included in the unit rate.
Supply, Install & testing of DOL starter suitable for 7.5 HP openwell submersible pump complete all as specified and directed.
Weatherproof copper conductor PVC flat cable 4 Sqmm 3 core for connection of pump to starter and panel board complete all as specified and as directed.
Galvanised tubing medium grade 80 mm nominal bore for passing of cable, fixed to poles / walls / laying under floor/ roads complete with and including fittings, clamps nut bolts as required complete all as specified and as directed.
Brass mental globe or gate valves, with iron wheeled head screwed both ends of iron pipes for 80 mm bore pipe fixed complete all as specified and directed.
Flexible hose reel Pipe suitable for 80mm dia GI pipe complete all as specified and as directed.
PCC 1:2:4 type B-1 using (20mm graded crushed stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, Benching, kneelers, apex stones, bed plates, kerbs, saucer drain(including finishing top surface of drain even and smooth without using extra cement), water troughs and the like including weathering, slightly rounded or chamfered angles and throating, and similar work including use & waste of necessary form work complete all as specified and as directed.
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation of pipeline and getting out in hard dense soil complete as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soil complete all as specified.
Removing of excavated materials n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
Sand cushioning with a layer of sand 8cm thick before laying of cable and 15cm thick after laying of cable in trenches complete all as specified and directed.
Unreinforced precast concrete cable cover, ISI marked class LV types 2 flat size 250mm x 150mm x 40mm having minimum average breaking load 200Kg, complying IS:5820-1970 made of concrete used of grade M-20, laid flat in trenches over the cable with the length of concrete cover perpendicular to the direction of the cable length, adjacent / abutting each other complete all as specified.
Electric siren of 3 phase 440 Volts, 50 Hz with audioable range of 3.25 Km alongwith suitable size starter, push buttons and its connected electrical acessories complete all as specified and directed. Make : KHERAJ Model No. HDT-325 or equivalent model of Perfect.
PVC insulated 3 core 2.5 Sqmm multi stranded copper conductor cable complete all as Specified and directed by Engr-in-Charge.
Point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade / PVC surface casing caping of size not less than 20mm width complete with and including all PVC conduit accessories and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc including all cutting / chases etc in walls complete all as specified and directed.
(a) One light point controlled by one switch
(b) One ceiling fan /Exhaust fan controlled by one switch & regulator
(c) One 5 Amps 3/5 pin socket outlet on independent board.
Point wiring with 2.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 2.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade / PVC surface casing caping of size not less than 20mm width complete with and including all PVC conduit accessories and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc including all cutting / chases etc in walls complete all as specified and directed for Description a for independent switch socket outlet 3 pin 5 Amps and all as directed at site.
Point wiring with 4 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 4 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade / PVC surface casing caping of size not less than 20mm width complete with and including all PVC conduit accessories and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc including all cutting / chases etc in walls complete all as specified and directed for Description a for switch socket outlet 3 pin 15 Amps all as directed at site.
Modular switch 1 way 6 Amps, 1 modules 230 volts complete all as specified and directed.
Ceiling rose surface bakelite 65x50mm 3 terminal complete all as specified and directed.
Modular socket 6A, 2/3 pin combined, 2 modules 230 volts complete all as specified and directed.
Modular socket 16A, 2/3 pin combined, 2 modules 230 volts complete all as specified and directed.
Modular switch 1 way 16 Amps, 1 modules 230 volts complete all as specified and directed.
Switch piano 1 way 6A, complete all as specified.
Socket outlet 2 in one 5/3 pin 5 Amps complete all as specified and directed.
Sheet metal enclosure, double door, single pole and neutral, AC, 415 volts, 8way, with 200 Amps rated copper bus bar and metal door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as directed by Engineer - in - Charge.
LED batten 24 watt 4 feet with aluminium housing & integrated electronic driver wall mounted type fitting with LED tube rod, complete all as specified and directed by Engr-in-Charge.
MCB SPN 32 Amps,10 KA breaking capacity 'C' Curve suitable 230 V,50 Hz for lighting and other domestic load complete all as specified and directed.
MCCB 4 pole 125 Amps, breaking capacity 25 KA, 415 Volts, fixed thermal & magnetic releases, (Conforms to IEC:60947-II / IS:13947-II) complete all as specified and as directed by Engineer-in-charge.
MCB TPN 40 Amps, 10 KA breaking capacity , C Curve suitable for 230 V, 50 Hz AC Supply complete all as specified and directed by Engineer - in - Charge.
MCB DP 32 Amps alongwith suitable enclosure complete all as specified and directed by Engineer - in - Charge.
MCB DP 40 Amps alongwith suitable enclosure complete all as specified and directed by Engineer - in - Charge.
Supply, install, testing and commissioning Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric underground power cable with stranded aluminium conductor cross sectional area 10 sqmm 4 core suitable for working on 1100 Volts, laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed.
Supply, install, testing and commissioning Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric underground power cable with stranded aluminium conductor cross sectional area 35 sqmm 3.5 core suitable for working on 1100 Volts, laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed. Note for item No. 56.00 & 57.00 :- Excavation, earthwork, sand cushioning, PCC protection cover, GI pipe shall be measured and paid for separately.
Galvanised tubing light grade 50 mm nominal bore for passing of cable, fixed to poles / walls / laying under floor/ roads complete with and including fittings, clamps nut bolts as required complete all as specified and as directed.
Cutting of PCC floor/foot path/hard standing/ Road up to 15cm wide and 30cm in depth for laying of pipe line/cable and making good surfaces by using 100mm thick PCC 1:2:4 type B-2 over hard core 150mm thick over rammed earth after laying of pipe line/ cable and removing rubbish outside MD land complete all as specified and as directed.
Wall mounted fan white in colour 300mm sweep 3/4 blades complete all as specified and as directed.
Ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep min air delivery 210 CFM with service value 6.00 BEE five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
Water heater storage type, electric,capacity 25 litres.BEE 5 star rated with rated power 230 V, 1 phase, 50 Hz AC, 2000 W fixing to wall with the help of heavy fastners Inner container Feroglas coated, Mounting vertical, Heating eleement Incoloy 800 glass coated, Temprature gauge, Temperature setting knob, water proof degree IP x 4, class of appliances Class-I, along with hot and cold water pipes of suitable lengths all as specified and as directed. Make : Havells 'PURO' or its equivalent model of makes specified in Appx 'B' here-in-before. Note : (a) Geyser to be fitted by company technician only. (b) Geyser fixing to be done only by heavy fastners. (c) Warranty card of every New Geyser will be submmited to the Engineer-in-Charge duly stamped.
20mm outer dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings on walls / ceiling or lying in floors complete all as specified and directed.
Female Brass Threaded Adaptor (MTA/ MBTA 20 mm x 15 mm size CPVC complete all as specified and directed.
JAY BHARAT METAL SUPPLIERS
BABUBHAI BHIMABHAI PANDAVADRA
SHREEJI ENTERPRISE
K K Construction Co
shree chamunda enterprise
SURESH ELECTRICALS
Leo Elevator Company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .