Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.3 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹27.1 L+₹74,540 (2.83%)Rejected-Finance | L2 | Rejected-Finance Rejected | |
| 3 | L3₹28.0 L+₹1.7 L (6.47%)Rejected-Finance 315 INDUSTRIAL AREA II PANCHKULA 134113 | PANCHKULA | HARYANA | 134113 | L3 | Rejected-Finance Rejected |
Tender Value
₹32.9 L
EMD Value
₹65,770
Closing Date
17 Apr 2023, 12:00 pmClosed
Executive Engineer Electrical
HIMUDA Electrical Division Dharamshala Distt. Kangra
Sub Head Providing Installation, Testing and Commissioning Addressable Fire Alarm System therein
2023_HIMUD_71955_1
HIMUDA/EDD/W-7/28-38
Open Tender
Electrical Works
Item Rate
180 days
Dharamshala Distt Mandi
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,770
Yes
₹65,770
Yes
17 May 2023
6 Apr 2023
17 Apr 2023
6 Apr 2023
17 Apr 2023
6 Apr 2023
6 Apr 2023 - 17 Apr 2023
Amount
Supply, Installation, Testing and Commissioning of Microprocessor based Intelligent Addressable Main Fire Alarm Control Panel with Suitable Loops modules and each loop capable of supporting not less than 250 devices (detectors & modules should be in any combination) ; Loop length up to 1.5 km, 8" Color LCD touch screen display with bright colors to indicate alarms and events, 4 Nos of Integrated Ethernet Ports & 2 Nos of , 200 Nos of Soft programmable keys with status indicators for individual triggering of NAC Ouputs, evacuation speaker zones, AHU Modules, Damper switch, Smoke extraction Fans, Lifts.. etc. The Panel shall support 10000 history logs in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 24 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger.The panel should also have IP30 or better protection. The panel shall have seamless integration with EVAC certified Public Address System and shall be complete with all accessories . EN54 / Vds/UL Certification Make Autronica/ Honeywell-Notifire / Bosch/Siemens EN
Supply, Installation, Testing and Commissioning of addressable multisensor smoke detector including mounting base with LED… etc. complete as required with 2 inbuilt Isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements; Drift Compensation feature & Automatic addressing. Detector should monitor Electromagnetic interference and report to the panel - current and average values.Detector should have IP40 or better protection rating. EMC safety for detector shall be 50 V/m. Shall be UL/EN/VDS certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector) Make Autronica/ Honeywell-Notifire / Bosch/Siemens EN
Supply, Installation, Testing and Commissioning of addressable Heat detector with fixed and rate of raise feature including mounting base with LED… etc. complete as required. Each Detector should have 2 inbuilt Isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and average values. Detector should have IP40 or better protection rating. EMC safety for detector shall be 50 V/m. Shall be UL/EN/VDS certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector) Make Autronica/ Honeywell-Notifire / Bosch/Siemens EN
Supply, Installation, Testing and Commissioning of smoke detector including mounting base with LED… etc. It should be capable of getting flush mount in the cieling in such a way it should . Detector should be able to match asthetic requirements of the area and shall be able with different colour rings to match with interiors.Detector shall be equipped with two opticalsensors ,Drift Compensation feature . Shall be EN54 -Vds/UL-FM Certification Make Autronica/ Honeywell-Notifire / Bosch/Siemens EN
Supply, Installation, Testing and Commissioning of addessable Single ACTION manual pull station & necessary fixing arrangements with key complete as required. MCP should have IP40 or better protection rating Shall be UL/EN/VDS Certified. Make Autronica/ Honeywell-Notifire / Bosch/Siemens EN
Supply, Installation, Testing and Commissioning of Addressable Monitor Module with 1 input, which shall monitor normally open or normally closed contacts.The module shall have an LED to indicate module status.It Shall be UL/EN/VDS Certified.Make Autronica/ Honeywell-Notifire / Bosch/Siemens EN
Supply, Installation, Testing and Commissioning of Addressable Control Relay Module with inbuilt isolators as per NFPA 72 style 7 wiring requirements .Relay Control module shall be used for emergency control functions including shutting down Fire dampers in AHU's, tripping of AHU's, Fresh air fans, Ventilation fans, tripping of Access control doorsetc.. Shall be EN54/ Vds Certification/UL Make Autronica/ Honeywell-Notifire / Bosch/Siemens EN
Supply, Installation, Testing and Commissioning of Active and networkable repeater panel with 4x20 character LCD display complete system function keys for programming and control like system reset, alarm acknowledgement, alarm silence, trouble acknowledgement etc. Shall be UL/EN/VDS Listed Make Autronica/ Honeywell-Notifire / Bosch/Siemens EN
Supply, Installation , Testing & commissioning of Glow Type EXIT Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink Sulphate as bare chemical class – 1 material PSPA fixed on 3 mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener including cost of labour & material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work Make PES/Giolite/OMEX
Supply,Installation,testing and commisioning of fault isolator compete with base as required or as approved by the engineer incharge .
Supply,Installation,testing and commisioning of power supply for hooter complete in all respect with connections as required or as approved by the engineer incharge .
Supply,Installation,testing and commisioning of PVC junction Box with SS screw & plate for detector as required or as approved by the engineer incharge .
Supply,Installation,testing and commisioning of respond indicator on surface/recessed MS Box having two LED ,mettallic cover complete with all connections etc as required or as approved by the engineer incharge .
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface recessed medium class PVC conduit as required
PVC unsheathed copper size 2 X 1.5 sq mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wireset, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required (But without MCB/RCCB/isolator) (4 Way double door)
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-Single pole. Cat-A.
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
63 Amps. Cat-A.
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No. HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.
2x10 Sq. mm.
AVNET SOLUTIONS
Insat Techno Services
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .