Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.8 LAccepted-AOC PARTH B 203 PATEL COLONY STREET NO 11 ROAD NO 3 JAMNAGAR 361 006 GUJARAT | JAMNAGAR | GUJARAT | 361006 | ₹42.8 L Quoted ₹44.0 L | L1 | Accepted-AOC L1 |
| 2 | L2₹45.9 L+₹1.9 L (4.42%)Rejected-Finance 00 CHAH KATHAUTI CHAH KATHAUTI MATHURA UTTAR PRADESH 281001 | MATHURA | UTTAR PRADESH | 281001 | ₹45.9 L+₹1.9 L (4.42%) | L2 | Rejected-Finance Not L1 |
| 3 | L3₹46.3 L+₹2.3 L (5.18%)Rejected-Finance 0 BADRI ELECTRICALS NEAR SHRIGOR FALI NEAR ANADABAWA CHAKLO JAMNAGAR GUJARAT 361001 UDYAM GJ 10 0001822 | JAMNAGAR | GUJARAT | 361001 | ₹46.3 L+₹2.3 L (5.18%) | L3 | Rejected-Finance Not L1 |
| 4 | L4₹47.1 L+₹3.1 L (6.94%)Rejected-Finance | ₹47.1 L+₹3.1 L (6.94%) | L4 | Rejected-Finance Not L1 |
| 5 | L5₹49.7 L+₹5.7 L (13.0%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | ₹49.7 L+₹5.7 L (13.0%) | L5 | Rejected-Finance Not L1 |
Tender Value
₹44.5 L
EMD Value
₹89,000
Closing Date
6 Jul 2019, 6:00 pmClosed
GE I NAVY JAMNAGAR
INS NAVY VALSURA JAMNAGAR 361150
WELCOME MAINTENANCE TO MD ACCN INCLUDING REPLACEMENT OF INTERNAL WIRING AND REPAIR REPLACEMENT AND MAINTENANCE OF INTERNAL ELECTRIFICATION OF ZONE A AND CONNECTED ITEMS AT INS VALSURA
2019_MES_261703_1
8378
Open Tender
Electrical and Maintenance Works
Item Rate
300 days
GE I NAVY JAMNAGAR
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE I NAVY JAMNAGAR
₹89,000
Yes
16 Jan 2020
21 Jun 2019
9 Jul 2019
22 Jun 2019
6 Jul 2019
1 Jul 2019
22 Jun 2019 - 29 Jun 2019
Amount
Taking down existing light fittings fixed in any description and S&F new 20 Watt wall mounted 4 ft glaze LED batten CCT(K) 6500 high quality design aluminium extruded with decortive and caps fixed as per manufacturers instructions and making necessary electrical connections and testing on completion complete all as directed. Make: Jaquar Cat No. LGLZ01X020XC 20 W CCT 6500 / Bajaj / Crompton / Philips / Wipro/ Havells.
Taking down existing light fittings fixed in any description and S&F new 10 Watt wall mounted 2 ft glaze LED batten CCT(K) 6500 high quality design aluminium extruded with decortive and caps fixed as per manufacturers instructions and making necessary electrical connections and testing on completion complete all as directed. Make: Jaquar Cat No. LGLZ01X010XC 10 W CCT 6500 / Bajaj / Crompton / Philips / Wipro
Taking down existing street light fittings of any type and S&F new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium roadway luminaire with high power LED as light source of power 25W, IP 66, system luminous efficacy >85 Lm/ W, life 50,000 hrs, zero maintenance including all light fittings etc. and connection from ceiling rose to light fitting by using two core 1.5 sq mm copper conductor cable complete all as specified. Make: Jaquar LSRT01S025XC or an equivalent specifications in Osram / Schreder / Bajaj BCLST 25W
Taking down existing any type of light fittings fixed in any description and S&F new 36 /40 W LED panel, indoor recessed / pendent mounted made from CRCA housing with full window acrylic diffuser, 2 ft X 2 ft lighting fixture flat light dissipater. The CCT(K) should be between 3000 to 6500 fixed as per manufacturers instructions and making necessary electrical connections and testing on completion complete all as directed. Make: Jaquar Cat No. LULT01S036XC / Bajaj SKYLUX BZRSQL 36W CZI W/N/CW / Havells Venus Neo HE4X1 PLR 36W LED 8XXS
Taking down existing light fittings fixed in any description S&F new 36 /40 W LED panel, indoor surface mounted made from CRCA housing with full window acrylic diffuser, 2 ft X 2 ft lighting fixture flat light dissipater. The CCT(K) should be between 3000 to 6500 fixed as per manufacturers instructions and making necessary electrical connections and testing on completion complete all as directed. Make: Jaquar Cat No. LSVR01S036SC / Schreder / Philips / Havells / Bajaj
S&F in repairs electronic driver suitable for LED fittings of 20 to 45 Watt. Make: Philips/Osram/Jaquar/C&S/Bajaj/GE etc
S&F in repairs electronic driver suitable for LED fittings of existing type of make / model of 24 to 45 Watt security light luminiares. Make: Philips/Osram/Jaquar/C&S/Bajaj/GE etc
S&F in repairs electronic driver suitable for LED fittings of 9 to 19 Watt. Make: Philips/Osram/Jaquar/C&S/Bajaj/GE etc
S&F in repairs ceiling rose surface bakelite White / Ivory / Urea finish 50 mm dia three terminals including supply and fix PVC square mounting block complete all as specified and directed.
S&F in repairs switch piano flush, single pole, one way 5 / 6 Amp complete all as directed. Make: Anchor / Standard / Leader
S&F in repairs switch socket outlet 3 Pin 6 Amp flush type complete all as directed. Make: Anchor / Standard / Leader
S&F in repairs switch socket outlet multipurpose 3 Pin 16 Amp and 3 pin 6 Amp, 240 Volt, controlled by one switch complete all as directed. Make: Anchor / Standard / Leader
S&F in repairs switch bell push, piano flush type, single pole, 6 Amp complete all as directed. Make: Anchor / Standard / Leader
S&F in repairs bell AC 230 Volt Ding Dong type, 240 Volt AC supply complete all as directed. Make: Anchor / HPL / Rider/ Leader
S&F in repairs switch modular type single pole one way 6 Amp with all accessories complete all as directed. Make: Legrand Cat No. 6755 01 or equivalent in Philips / Crabtree / ABB / Havells
S&F in repairs switch modular type single pole one way 16 Amp with all accessories complete all as directed. Make: Legrand Cat No. 6755 11 or equivalent in Philips / Crabtree / ABB / Havells
S&F in repairs socket outlet 3 Pin 6 Amp modular type all accessories complete all as directed. Make: Legrand Cat No. 6755 52 or equivalent in Philips / Crabtree / ABB / Havells
S&F in repairs socket outlet multipurpose 2/3 Pin for 6 / 16 Amp modular type with all accessories complete all as directed. Make: Legrand Cat No. 6755 55 or equivalent in Philips / Crabtree / ABB / Havells
S&F in repairs bell push 6 Amp modular type with all accessories complete all as directed. Make: Legrand Cat No. 6755 04 or equivalent in Philips / Crabtree / ABB / Havells
S&F in repairs RCBO 30 mA, having current carrying capacity 40 Amp, SPN complete. Make: Legrand Cat No. 411327 or equivalent Havells / L&T / ABB
S&F in repair sheet metal enclosure with socket plug top single pole and neutral enclosure with a two pin and earth plug and socket with one single pole 20 Amp MCB complete. Make: Legrand Cat No. 507814 / ABB / Siemens / Indo Asian
S&F in repairs epoxy powder coated sheet with metal door enclosures with 2 mm thick CRCA sheet for and including MCB DB SPN 4 way, 240 V with 200 Amp rated bus bar with double door locking system complete. Make: Legrand Cat No. 507610 10 / Havells / L&T / ABB
S&F in repairs epoxy powder coated sheet with metal door enclosures with 2 mm thick CRCA sheet for and including MCB DB SPN 8 way, 240 V with 200 Amp rated bus bar with double door locking system complete. Make: Legrand Cat No. 507611 11 / Havells / L&T / ABB
S&F in repairs epoxy powder coated sheet with metal door enclosures with 2 mm thick CRCA sheet for and including MCB DB TPN 4 way, 240 V with 200 Amp rated bus bar with double door locking system complete. Make: Legrand Cat No 507670 / Havells / L&T
S&F in repairs MCB SP 6 to 32 amp, 50 Hz, AC supply, 10 kA. Make: Legrand Cat No. 4085 87 to 4085 95 / Havells / L&T / ABB
S&F in repairs MCB SPN 10 to 32 Amp 240 V 50 Hz AC supply, 10 kA. Make: Legrand Cat No. 4086 12 to 4086 17 / Havells / L&T / ABB
S&F in repairs MCB SPN 40 to 63 Amp 240 V 50 Hz AC supply, 10 kA. Make: Legrand Cat No. 4086 18 to 4086 20 / Havells / L&T / ABB
S&F in repairs MCB TPN 6 to 32 Amp, 50 Hz, AC supply, 10 kA with proper size lugs. Make: Legrand Cat No. 4086 72 to 4086 80 / Havells / L&T / ABB
S&F in repairs MCB TPN 40 to 63 Amp, 240 V, 50 Hz, AC supply. Make: Legrand Cat No. 4086 81 to 4086 83 / Havells / L&T / ABB
S&F in repairs MCCB 125 Amp 3 pole 25 kA in existing board connecting with proper size link set at incoming and outgoing cable connections and making necessary modification in existing panel as required complete all as directed. Make: Legrand Cat No. 4200 46 or an equivalent in Havells / L&T
S&F in repairs MCCB 100 Amp 3 pole 25 kA in existing board connecting with proper size link set at incoming and outgoing cable connections and making necessary modification in existing panel as required complete all as directed. Make: Legrand Cat No. 4200 45 or an equivalent in Havells / L&T
S&F in repairs MCCB 63 Amp 3 pole 16 kA in existing board connecting with proper size link set at incoming and outgoing cable connections and making necessary modification in existing panel as required complete all as directed. Make: Legrand Cat No. 4200 03 or an equivalent in Havells / L&T
S&F in repairs fan step regulator, AC, 230V electronic type, single pole complete all as directed. Make: Bajaj / Anchor / Standard / Leader
S&F in repairs step type, electronic fan regulator, 2 module, AC, 230 V complete all as directed. Make: Legrand Cat No. 6755 30 or an equivalent in Crab tree / Schneider / Philips / Panasonic.
S&F in repairs step type, electronic fan regulator, 1 module, AC, 230 V complete all as directed. Make: Legrand Cat No. 6755 31 or an equivalent in Crab tree / Schneider / Philips / Panasonic.
Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators, sockets etc. to be measured separately), removing materials to store for keeping in safe custody for re-use at site and making good disturbed surfaces of walls, floors, etc to match with the existing surface complete all as directed.
M&L for point wiring with 1100 V, 1.5 Sqmm single core PVC insulated unsheathed cable, copper conductor multistranded passing through heavy duty PVC casing, capping, min 25 mm wide including sheet metal box, terminal plates suitable for modular switch, socket etc. with all accessories, concealed MS box / PVC modular box with cover and 1.5 sqmm earth copper cable, for one light point, bell point, fan point controlled by one switch including cutting and making good surface of walls applying suitable painting as required all as directed.
All as per item No. 37 here-in-above, but for 6 Amp (2/ 3 pin), modular switch socket in same board with earth wire 1.5 Sq.mm PVC insulated multistranded copper conductor cable complete all as directed.
All as per item No. 37 here-in-above, but for 6 Amp (2/ 3 pin), modular switch socket in independent board with earth wire 1.5 Sq.mm PVC insulated multistranded copper conductor cable all as directed.
All as per item No. 37 here-in-above, but size of cable 2.5 Sq.mm for 16 Amp and 6 Amp (3 pin) combined, modular switch socket in independent board with earth wire 2.5 Sq.mm PVC insulated multistranded copper conductor cable all as directed.
M&L for point wiring with 1100V grade with 1.5 Sqmm single core PVC insulated cable, copper conductor multistranded passing through in existing PVC concealed 20 mm dia conduit and conduit accessories with concealed MS/ PVC Box and logic modular white plate of suitable size as required at site with PVC insulated unsheathed stranded copper conductor of size 1.5 sqmm as earth wire connected to common earth dolly as specified for one light point controlled by one switch complete all as directed. Note : (1) Rate include cost of cutting wall / floor / ceiling and making chasses and MS box in concealed for cutting and sinking for boxes and making good to walls, no extra payment will be made for the same. (2) Switch and socket shall be measured and paid separately.
All as per item No. 41 here-in-above, but for 6 Amp (2/ 3 pin), modular switch socket in same board with earth wire 1.5 Sq.mm PVC insulated multistranded copper conductor cable complete all as specified.
All as per item No. 41 here-in-above but for 6 Amp (2/ 3 pin), modular switch socket in independent board with earth wire 1.5 Sq.mm PVC insulated multistranded copper conductor cable complete all as specified.
All as per item No. 41 here-in-above but size of cable 2.5 Sq.mm for 16 Amp and 6 Amp (3 pin) combined, modular switch socket in independent board with earth wire 2.5 Sq.mm PVC insulated multistranded copper conductor cable all as directed.
M&L for 1100 V, 1.5 Sqmm single core PVC insulated unsheathed cable, copper conductor multistranded wire of appropriate color code as required at site and passing through existing concealed conduit from any point to concealed GI switch box complete all as directed.
All as per item No. 45 here-in-above but size of cable 2.5 Sq.mm.
All as per item No. 45 here-in-above but size of cable 4 Sq.mm.
Taking down old existing sub main wiring and M&L for sub main wiring with 2 run single core 2.50 Sq.mm PVC insulated unsheathed copper multistranded conductor 1100 Volts grade drawing into and including PVC heavy duty casing and capping with PVC coated copper earth conductor 2.50 Sq.mm one run complete. Note: 2 run of 2.50 Sq.mm cable one run 2.50 Sq.mm earth wire with casing capping considered as one unit.
Taking down old existing sub main wiring and M&L for sub main wiring with 2 run single core 4 Sq.mm PVC insulated unsheathed copper multistranded conductor 1100 Volts grade drawing into and including PVC heavy duty casing and capping with PVC coated copper earth conductor 6 Sq.mm one run complete. Note: 2 run of 4 Sq.mm cable one run 4 Sq.mm earth wire with casing capping considered as one unit.
Taking down old existing sub main wiring and M&L for sub main wiring with 2 run single core 6 Sq.mm PVC insulated unsheathed copper multistranded conductor 1100 Volts grade drawing into and including PVC heavy duty casing and capping with PVC coated copper earth conductor 6 Sq.mm one run complete. Note: 2 run of 6 Sq.mm cable one run 6 Sq.mm earth wire with casing capping considered as one unit.
M&L one side white laminated sheet board of size 3 mm thick of any size for fixing meter box/ switch board.
S&F in repairs PVC rectangular block of size 100 X 100 mm, 50mm deep for mounting switches, sockets, fan regulator etc. within 3 mm thick plastic laminated sheet cover.
S&F in repairs PVC rectangular block of size 175 X 100 mm, 50mm deep for mounting switches, sockets, fan regulator etc. within 3 mm thick plastic laminated sheet cover.
S&F in repairs PVC rectangular block of size 150 X 150 mm, 50mm deep for mounting switches, sockets, fan regulator etc. within 3 mm thick plastic laminated sheet cover.
S&F in repairs PVC rectangular block of size 200 X 300 mm, 50mm deep for mounting switches, sockets, fan regulator etc. within 3 mm thick plastic laminated sheet cover.
M&L for PVC casing and capping min 25 mm wide, in repairs by using existing wiring, for light point, fan point, bell point, PVC boards, good finishing for including screws, bolts nuts, drilling etc.
S&F single pointed air termination aluminium rod 12mm dia and 300mm long.
S&F in repairs aluminium strip 25x3 mm complete with insulators and fixing materials for fitting the strip complete.
S&F in repairs GI strip 32x6 mm complete buried in ground / wall.
S&F in repairs test point terminal block made of gun metal or phosphorus bronze size 75x75x25 mm drilled and screwed including 3 Nos. 8mm dia 25mm long hex. head screw.
M & L for PCC 1:3:6, type C2 using 40 mm graded crushed stone aggregate as in foundation filling mass concrete complete all as specified and directed
M&L pre cast PCC 1:2:4 type B1 (using 20 mm graded granite aggregate) as in block masonry with solid blocks, exceeding 10 cm in width and setting in CM 1:4 complete all as specified.
M&L bus bar insulator with two Nos. of screws of size 40 mm long fixed in PCC solid block for running the roof conductor
S&F in repairs earth continuity conductor or main earthing lead of galvanised iron wire of size 4 mm dia, fixed on pole from existing earth test point complete all as directed.
M&L for earthing complete with galvanized steel earth plate as electrode 600x600x6 mm buried directly in ground vertically to a depth not less than 2.25 m below ground level with top edge of earth plate at a depth not less than 1.5 m below ground level connected using galvanized iron earth lead strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI earth lead strip protected by Gl light grade pipe 40 mm bore, including provision of concrete pit of PCC 1:2:4, type B1 (using 20 mm graded stone aggregate) with 40 mm thick cover of RCC 1:2:4 reinforced with 8 mm dia TMT bars reinforced at 100 mm C/C both ways and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 2 m long placed on top edge of earth plate, char coal and common salt filling test point made out of 40x8 mm flange with fixing arrangement, funnel, wire mesh and earth work in any type of soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 m all as per electrical Plate No. 3 of SSR Part I and connected to earth test point, including taking down existing earthing complete all as specified including testing on completion.
M&L for earthing complete with galvanized steel earth plate as electrode 600x600x6 mm buried directly in ground vertically to a depth not less than 2.25 m below ground level with top edge of earth plate at a depth not less than 1.5 m below ground level connected using galvanized iron earth lead wire 4 mm dia as earthing lead by means of bolts, nuts, check nuts and washers of GI earth lead wire protected by Gl light grade pipe 15 mm bore, including provision of concrete pit of PCC 1:2:4, type B1 (using 20 mm graded stone aggregate) with 40 mm thick cover of RCC 1:2:4 reinforced with 8 mm dia TMT bars reinforced at 100 mm C/C both ways and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 2 m long placed on top edge of earth plate, char coal and common salt filling test point made out of 40x8 mm flange with fixing arrangement, funnel, wire mesh and earth work in any type of soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 m all as per electrical Plate No. 3 of SSR Part I and connected to earth test point, including taking down existing earthing complete all as specified including testing on completion. Note: (i) The contractor has to check the fittings / fixtures and wiring as per the complaint given by the Engineer-in-Charge / concerned JE. Spares being replaced shall be intimated by JE and the replaced spares will be measured and paid under respective items of BOQ and no extra payment will be done for the same. (ii) It is the responsible of the Contractor to ensure that day to day complaints slips are collected every morning before distibuting labours from JE from MES service centre and attend & complete the complaints the same day irrespective of any number of complaints and return back the complaint slip duly signed by the User to JE the same evening as a token of defect rectified as such contractor to make all arrangements including supply of materials required for attending complaints without any delay, the quoted rate aganist vasrious items is deemed to be inclusive of above excersice.
1R K Traders
M/S Badri Electicals
suvidhiconstruction
jagdish machinery stores
JAMNAGAR ELECTRIC AND MACHINERY CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .