Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹66.1 LAccepted-AOC PSRA 146 A PULIMOOTTIL ROAD PADAMUGAL INDRA JUNCTION KAKKANAD PO KOCHI 682030 | KOCHI | ERNAKULAM | KERALA | 682030 | ₹66.1 L | L1 | Accepted-AOC Lowest tenderer |
| 2 | L2₹68.0 L+₹1.9 L (2.84%)Rejected-AOC 121004 | ₹68.0 L+₹1.9 L (2.84%) | L2 | Rejected-AOC Other than lowest tenderer |
| 3 | L3₹75.0 L+₹8.9 L (13.5%)Rejected-AOC KATTUPADATH H AZHEEKAL PO VYPEEN 682508 | KOCHI | ERNAKULAM | KERALA | 682508 | ₹75.0 L+₹8.9 L (13.5%) | L3 | Rejected-AOC Other than lowest tenderer |
| 4 | L4₹79.8 L+₹13.7 L (20.8%)Rejected-AOC CHEMBISSERY PUTHIYAKAVU TRIPUNITHURA P O KOCHI 682301 | ERNAKULAM | KERALA | 682301 | ₹79.8 L+₹13.7 L (20.8%) | L4 | Rejected-AOC Other than lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹1.5 L
Closing Date
4 Nov 2022, 6:00 pmClosed
CWE (NW) KOCHI
CWE (NW) KOCHI NAVAL BASE KOCHI
CERTAIN SANCTIONED E/M WORKS AT NAVAL BASE, KOCHI
2022_MES_555357_1
CWE(NW)/KOCHI/81313
Open Tender
Civil Works
Item Rate
270 days
KOCHI
AS PERNIT
6 documents required · 6 mandatory
₹1,000
GE (NW) KOCHI
₹1.5 L
Yes
29 Nov 2022
30 Sept 2022
7 Nov 2022
30 Sept 2022
4 Nov 2022
21 Oct 2022
30 Sept 2022 - 25 Oct 2022
Amount
Taking down copper/aluminium point wiring (light, fan,bell point, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, sheet metal encl. with plug & socket etc. Removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.
M&L point wiring with 1.5 Sqmm PVC insulated unsheathed FRLS multistranded single core copper conductor cable in PVC concealed conduit rigid non metallic ( ISI marked ) fixed concealed in wall /roof except beam, column and RCC roof including chases cutting incl 1.5 Sqmm PVC insulated copper conductor as earth continuity wire for One light point controlled by one switch complete all as specified and as directed.
All as per item No. 2 above but for One fan point / exhaust fan point controlled by one switch & regulator complete all as specified and as directed.
All as per item No. 2 above but for One 5 pin 5 Amps Socket point controlled by one switch on same board complete all as specified and as directed.
All as per item No. 2 above but for One 5 pin 5 Amps socket point controlled by one switch on independent board complete all as specified and as directed.
All as per item No 2 above but with 2.5 Sqmm copper conductor including 2.5 Sqmm copper cable as earth wire for one 6 Pin 16 Amps Socket outlet on independent board complete all as specified and as directed.
All as per item No 2 above but with 4 Sqmm copper conductor including 4.0 Sqmm copper cable on earth wire for sheet metal enclosure complete all as specified and as directed.
S&F Switch piano, flush type single pole, one way 5 Amp complete all as specified and as directed.
S&F Switch piano, flush type single pole, one way 16 Amp complete all as specified and as directed.
S & F Socket outlet 2 in 1, 3 pin, 5A complate all as specified and as directed.
S & F Socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type complete all as specified and as directed.
S & F Ceiling rose, 3 phase/PVC/ polycarbonate, isolated body complete all as specified and as directed.
Taking down existing Tube Light fittings / Mirror light/ Concealed light 2x2/ 1x1 of any type and size and removing to store yard for safe custody and for reuse or taking as credit all as specified and directed.
Taking down existing security light/ aviation light/ high bay lights/ flood lights of any type and size and removing to store yard complete all as specified and as directed.
Taking down existing MCB DB SPN with MCBs of any type and size and removing to store yard complete all as specified and as directed.
Taking down existing MCB DB TPN with MCBs of any type and size and removing to store yard complete all as specified and as directed.
Taking down old sub main wiring of any size and making good disturbed surface all as specified and directed complete all as specified and as directed.
Taking down existing LT cable of any type and making good disturbed surface all as specified and directed complete all as specified and as directed.
Taking down existing junction boxes with MCBs and busbar of any type and making good disturbed surface all as specified and directed.
Supply & fix LED down lighter 2'x2' , 36/40 W 240 volt all as per specified and directed. Make Havells Cat Part No. ENDURASLIMPROPLUS 2x2 PLR36WLED 840MOD and driver LEDDRIVER36V36WS or Crompton Cat Part No. LCTLRN-36-FO-CDL/ Philips Cat Part No. RC380BLED36S-6500G4L60PSUOD.
Supply & fix Regal Batten for LED tube lights, both side connection type all as specified and as directed. Make of batten : Havells Cat Part No. REGALBATTENT 8UPTO1X22WSSBSWH / Crompton Cat Part No. IGP131LT8-16 / Philips Cat Part No. TMC501P1XTLED22WP3241
Supply & fix LED down lighter, round or square, 12 W,240 volt all as per specified and directed. Make Crompton Cat Part No. LSDEP-12-CDL or Polycab Cat Part No.LD001200041/ Philips Cat Part No. 94051090
S & F for LED Mirror light fitting 8 watt with connected accessories complete all as specified & directed. Make :Crompton Cat No. LDL-10-WW or Polycab Cat Part No. LD00103040 / Luker Cat Part No. LTSM10
S&F LED flood light made up of pressure die cast housing with toughened glass and high power LEDs with option of secondary optic with IP 66 protection, 3000 K, with 10 KV SPD of 50 watt complete all as specified and directed including taking down of existing light fitting. Make : Crompton Cat Part No. LFL-50-CDL/60-M or Jaguar Cat Part No. LFLD02S050XW/ Philips Cat Part No. BVP 161 LED 43 NW/CW/WW 50W.
S&F LED high bay llight of 150 W IP66&IK08 protected highbay with PDC housing & toughened glass suitable for ceiling(surface/suspended) mount including all connection all as specified and as directed.Cat part no LHBY50 of Luker or Philips/Wipro
Supply and fixing building security light made up of pressure die cast housing with toughened glass and high power LEDs with option of secondary optic with IP 66 protection of 30 Watt including suitable GI bracket of 25 mm dia and fixing arrangement on walls all as specified and directed including taking down of existing light fitting. Make : Crompton Cat Part No. LSTS-30-CDL/NL-M or Philips HSN code 94054090/ Jaguar Cat Part No. LPCRSRT30WXW.
Taking down ceiling fan, Painting of celing fans/Exhaust fan/wall fan complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. and hanging in original position and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and as directed.
S & F stepped type electronic fan regulator flush type 5 steps, 230 Volt, 120 Watt on the existing phenolic laminated sheet etc. as required complete all as specified and as directed.
S&F Sheet metal enclosures with socket plug top and MCB' single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 20 A MCB complete all as specified and as directed.
S&F Sheet metal enclosure VTPN for DB's when MCCB's to be used 4 way with 200 amps bus bar double door all as specified.
S&F SPN sheet metal enclosure for DB 8 ways Double doorall as specified.
S&F MCCB 4 pole, 415 Volt fixed type 125 Amps with breaking capacity 16 KA complete all as specified and directed.
S&F MCB 'B' Curve 63 Amp Three pole, 415 Volts, all as specified and directed. Make L&T Cat Part No. BB30630B or Legrand Cat Part No. 408620/ Schneider Cat Part No. A9NIP63B.
S&F MCB 'B' Curve 40 Amp SPN ,240 Volts all as specified and directed. Make L&T Cat Part No. BB20400B or Schneider Cat Part No. A9NIP40B/ Legrand Cat Part No. 408618
S&F MCB 'B' Curve SP 6 To 32 Amp , 240 Volts, all as specified and directed. Make Schneider Cat Part No. A9N1P06B to A9N1P32B, or L&T Cat Part No. BB10060B to BB10320B / Legrand Cat Part No. 408587-408596
S&F energy efficient ceiling fan of 1200mm sweep (5 star rated) 230 Volt 50 Hz including all electrical connection all as specified and as directed. make :- Havells Cat Part No. ES-40 or Crompton Cat Part No. Maximus (5 star rated) Atomberg Model EFFICIO+ or equivalent make in list of manufactures”
“S&F 250mm sweep, PVC body exhaust fan heavy duty, single phase 230 Volts, 900 RPM all as specified & directed. Make: Havells Cat Part No. Ventil Air-DX white or Crompton Cat Part No. EXHD300-4-1 /Atomberg Model EFFICIO or equivalent make in list of manufactures.
M/L submain wiring with 2 single core 4 Sqmm PVC insulated unsheathed multistranded copper conductor cable 1100 volt grade drawn throgh and including suitable PVC rigid conduit concealed wiring inculding necessary PVC conduit specials including chases cutting complete exceapt beam and RCC roof and one run of 4Sqmm PVC insulated unshearthed single core 1100 volts grade multistranded copper conductor cable as earth continuity conduto9r and connceting with suitable size thimble complete allas specified and as directed. Note: two run of 4 sqmm size PVC cable , one run of 4 Sqmm size PVC cable as earth wire and one run of PVC conduit shall be measured as one unit length complete all as specified and as directed.
All as per item No 38 but 2 single core 6 Sqmm with 6 Sqmm earth wire all as specified and as directed. Note: two run of 6 sqmm size PVC cable , one run of 6 Sqmm size PVC cable as earth wire and one run of PVC conduit shall be measured as one unit length complete all as specified and as directed.
All as per item No 38 above 4 runs of 6 Sqmm PVC copper conductor including 2 runs of 6 Sqmm copper conductor as earth wire all as specified and as directed. Note: four run of 6 sqmm size PVC cable ,two run of 6 Sqmm size PVC cable as earth wire and one run of PVC conduit shall be measured as one unit length complete all as specified and as directed.
Taking down of existing unserviceable earthing of any type and making good disturbed surface all as specified and as directed.
M&L in repair earthing complete with galvanised steel earth plate electrode 60 cm x 60cm x6 mm thick, buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meters below normal ground level, connected to GI earth lead wire 4mm dia upto length 7.5 mtr by means of bolts, nuts and washers of galvanised steel all as shown in electrical plate No. 3 connected to earthing test point complete all as specified and indicated including testing on completion including taking out old earthing complete. Note : The rate is deemed to be inclusive of the cost of complete earth work in any type of soil. PCC 1:3:6 type C-1 for chamber, RCC 1:2:4 type B1 for cover slab 50 mm thick, reinforcement 8 mm CTD bars @ 100 mm c/c both way, necessary form work, handle, charcoal dust 20mm dia GI med grade for watering and 40mm dia GI med grade earth lead protection pipes with funnel and wire mesh all complete all as specified and directed.
S&F Integral aviation obstruction light fitting comprising of aluminium housing with polycarbonate inclouser including fixing arrangement and connection complete all as specified and as directed.Cat part no BGAV 302 LED of bajaj or Philips/wipro .
Refixing of existing cable removed as per Srl Item No. 18 above on walls/ceilings with necessary clamps, saddles, screws etc all as specified and as directed.
S&F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of 6 Sqmm 2 core complete on walls/ ceilings with necessary clamps, saddles, screws etc for street light fittings all as specified and as directed.
Supply and fixing street light control panel, single phase 6 KW load with 24 hour Digital timer, Contactor rating 32 Amps TP, MCB rating 40 Amps SPN complete all as specified and as directed. Havells Cat Part No. IHXSS01060
Supply and Fixing PVC Junction box, with 2 x Aluminium busbar and one MCB SP 6 Amps for controlling street/ security lights water tight all as specified and directed. Make : Syntex or equivalent
Refixing only existing LED tube rods obtained as per item No. 13 above on new fittings all as specified and directed.
S&F air termination single pointed aluminium rod 12 mm dia and 300 mm long complete all as specified and as directed.
S&F test point terminal block made of gun metal or phosphorus bronze size 75 x 75 25 mm, and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screw including PVC junction box complete all as specified and as directed.
S&F aluminium strip 25 x 3.15 mm with saddles, insulators and fixing screws etc for roof conductors and down conductors on walls/above ground complete all as specified and as directed.
M&L earthing complete with galvanised steel earth plate electrode 60 cm x 60cm x6 mm thick, buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meters below normal ground level, connected to GI earth strip 32x6 mm as earth lead 7.5 mtrs by means of bolts, nuts and washers of galvanised steel all as shown in electrical plate No. 3 connected to earthing test point complete all as specified and indicated including testing on completion including taking out old earthing complete. Note : The rate is deemed to be inclusive of the cost of complete earth work in any type of soil. PCC 1:3:6 type C-1 for chamber,RCC 1:2:4 type B1 for cover slab 50 mm thick, reinforcement 8 mm CTD bars @ 100 mm c/c both way, necessary form work, handle, charcoal dust 20mm dia GI med grade for watering and 40mm dia GI med grade earth lead protection pipes with funnel and wire mesh complete all as specified and as directed.
Taking down old air termination rod and making good surface complete all as specified and as directed.
Taking down old test point block and making good surface complete all as specified and as directed.
Taking down old aluminium strip and making good surface complete all as specified and as directed.
Taking down old earthing complete all as specified and as directed.
Taking down existing Light fittings of any type and size and removing to store yard complete all as specified and as directed.
Supply and fixing box type, both side connections LED tube light fitting ( Batten) with both side connection LED tube rod 20W with all fixing accessories and connections to the existing electrical system complete all as specified and as directed. . Make Havells Cat Part No. BATTENT 8 UPTO 1x 22W SSWSSBSWH & CRYSTAL 1213T8DSTC20WLED 865 SGLASS, Crompton Cat Part No. LGT8-20-865-2, Jaquar Cat Part No. LTBLGlX020C
S&F of recess mounting 2x2 CRCA powder coated white after phosphochromate treatment housing luminaire with high performance LEDs, suitable for mounting with Armstrong/ Grid ceiling with 36W, CRI>80, 6500K, 100 Lm/Watt. Make Havells Model VENUSNEO2x2PLR36WLED857POTR / Philips Cat Part No. RC380BLED36S-6500G4L60W60PSUOD / Crompton Cat Part No. LCPL-36-CDL (2x2) or equivalent make in list of manufactures
S&F of surface and wall mounted 2 feet linear LED batten with polycarbonate housing & integrated electronic driver, 10W, 6500K, Minimum 100 Lm/Watt, CRI ≥ 80 directed.Make : Havells Cat Part No. LUMILINEBS10WLED865SPCWH / Philips Cat Part No. BN 021 LED10S 6500 PSU GR S1 / Luker Cat Part No. LMR 10 or equivalent make in list of manufactures
S&F of suspended linear light fitting 36W, 4 feet length, 5700K, CRI ≥ 80, 110 Lm/Watt, suspension kit, end caps & cable for mounting accessories complete all as specified and directed. Make : Havells Cat Part No. DESTG2501P/S36WLED857SWH1130 / Philips Cat Part No SP811P LED33S-6500 PSD W6L120 OD SI / Wipro Cat Part No. LM31-401 XXX-57WGI or equivalent make in list of manufactures
Supply and fixing LED Highbay luminaire,80watt,Uniquely designed circular highbay with IP lens 110 Lumens/W , IP66 with additional safety chain and all necessaries connection complete as directed by EIC Make CG cat No TIP-320-80-57-SL-GL-NSG or Havells Cat Part No. SAUCERGENXHBP80WLED757P60DBOLTG / Bajaj Cat Part No. TENTO nxt B88L WH N BSD or equivalent make in list of manufactures”
S&F 4 feet surface mounted batten type 20W LED luminaire with emergency light output, shall be maximum 4 hours battery backup in case of power failure with Li battery, luminaire efficacy 100 lm/w with an operating voltage range from 140V-270V, initial lumen at battery mode will reduce to 35-50%, charging time approx 8-12 hours. The luminaire shall have aluminium extruded main housing. PC LED front cover. The luminaire shall have a CCT of 6500K, CRI>80. Power factor hours as per L70 B50 criteria. The luminaire shall be EMI/ EMC complaint and shall have open and short circuit protection, reverse polarity protection, internal surge protection of 30 KV IP 20 ingress protection. Make : Halonix Model No HLB-08-20-CW-INV or Havells Cat Part No. MAGNUMGRANDPWB1P6620WLED857SPC or equivalent make in list of manufactures”
Supply and fix LED Tubelight fitting 20 Watts DAWN PLUS, smart Extruded Aluminium LED Batten (4 ft) with higher efficiency, Microwave sensor to save more energy reduces the light by 70% during non-occupancy complete all as specified and directed by Engr-in-charge. Cat Part No. BCLAB 20W LED PS of Bajaj or Havells Cat Part No. LUMILINESMART20WLED865PCWH / Philips or equivalent make in list of manufactures ”
Supply and fixing call button with modes of operating online and offline ,user input- call,cancel,acknowledge and house keeping ,range -300 mtrs ,battery backup-1 years,materials-ABS(Acrylonitrile butadiene styrene),buzzer frequency-4 Khz,radio module-compatible with Lora at 867 Mhz, customizable 137-1020 Mhz,bandwidth 400 nm ,RJ4 PC,IP-32,battery used -Alkaline battery complete all as specified and as directed by the Engr-in-Charge. Make -Evelabs / Yarward Nurse Call System / FORBIX SEMICON or equivalent make in list of manufactures
Supply and fixing pandant button with 1.5 mtr wire,materials-ABS(Acrylonitrile butadiene styrene) 3 D printed ,colour white and orange ,connetion to main call button RJ-11 complete all as specified and as directed . Make - Evelabs / Yarward Nurse Call System / FORBIX SEMICON or equivalent make in list of manufactures”
Supply and fixing Evegate Lora Gateway single channel with modes of operating online, offline and config , device range -700 mtrs,working modes -serial,MQTT,Websocket,Supports up to 150 nodes ,WIFI-802.11b/g/n,type C USB connection ,radio module-compatible with Lora at 867 Mhz, customizable 137-1020 Mhz,bandwidth 125 Mhz ,Led idicator -red blue and green ,IP-32 ,battry input 5V,1 Amp complete all as specified and as directed . Make -Make : Evelabs / Yarward Nurse Call System / FORBIX SEMICON or equivalent make in list of manufactures”
Supply and fixing Evegate Lora Gateway repeater with modes of operating online, offline and config , device range -700 mtrs,working modes -serial,MQTT,Websocket,Supports up to 150 nodes ,WIFI-802.11b/g/n,type C USB connection ,radio module-compatible with Lora at 867 Mhz, customizable 137-1020 Mhz,bandwidth 125 Mhz ,Led idicator -red blue and green ,IP-32 ,battry input 5V,1 Amp complete all as specified and as directed.Make -Make : Evelabs / Yarward Nurse Call System / FORBIX SEMICON or equivalent make in list of manufactures”
Supply and install 32 inch smart monitor with Processor-cortex -A 53 x 4.64 bit,Graphic Processor-Mali 470x2,RAM-1.5 GB, ROM-8 GB,Suported mobile system-Android ios,all supported app , pre installed nurse call software with patient call history call alert ,average response time and commplete all as specified and as directed .make-Acer / HP / Dell or equivalent. Note:-The rate quoted will be inclusive of two years annual maintenance and replacement warranty for Ser No. 65 to 69.”
M&L galvanised iron strip 32X6mm burried in ground or under floor or through GI pipe and connecting to the existing /new system by welding complete all as specified and as directed.
M/L submain wiring with 2 single core 2.5 Sqmm PVC insulated unsheathed multistranded copper conductor cable 1100 volt grade drawn throgh and including PVC rigid conduit concealed wiring inculding necessary PVC conduit specials including chases cutting complete exceapt beam and RCC roof and one run of 2.5 Sqmm PVC insulated unshearthed single core 1100 volts grade multistranded copper conductor cable as earth continuity condutor and connceting with suitable size thimble complete allas specified and as directed. Note: two run of 2.5 sqmm size PVC cable , one run of 2.5 Sqmm size PVC cable as earth wire and one run of PVC conduit shall be measured as one unit length complete all as specified and as directed.
Taking down old galvanised iron strip and making good surfaces complete all as specified and as directed.
Supply and Fix exhaust fan, steel body AC single Phase, 230V of size 300m sweep, 900 RPM, with blades and frame and louvers complete including connecting to the existing electrical system all as specified and as directed. Make : Havells Cat Part No. Ventil Air – DB Neo / Bajaj Model Bahar / Usha Cat Part No. S.PH TURBO HDEF 900RPM ISI GREY or equivalent make in list of manufactures”
All as per item No. 73 above but for 380mm sweep, 900 RPM complete all as specified and as directed. Make : Almonard Model. MARK/ Havells Cat Part No. Turbo Force SP / Usha Cat Part No. S.PH TURBO HDEF 900RPM ISI GREY or equivalent in list of manufactures”
All as per item No. 73 above but for 450 mm sweep, 900 RPM, heavy duty complete all as specified and as directed. Make : Almonard Model. HEAVY DUTY EXHAUST FAN / Havells Cat Part No. Turbo Force SP / Usha Cat Part No. S.PH TURBO HDEF 900RPM ISI GREY or equivalent in list of manufactures”
S&F wall mounted air circulators metallic body, 600mm sweep, 1440 rpm with fixing arrangements on wall including screws, rawal plugs etc. connetcing to the electrical system all as specified and directed. Make:Havells Cat Part No. Turbo Force /Usha Model DOMINAIRE / Bajaj Model SUPREME PLUS or equivalent in list of makes”
All as per item No. 76 above but for 400mm/ 450 mm sweep complete all as specified and as directed.. Make: Havells Cat Part No. Turbo Force / Almonard Model EFFICIO + / CromptonCat Part No. WMSDX 120 or equivalent in list of makes”
Taking down existing exhaust fan, sealing cable end, dismantling blades and removing fan and blades to store complete all as specified and as directed.
All as per item No. 78 above but for wall fans/ air circulators complete all as specified and as directed
Taking down old ceiling fans sealing cable end, dismantling blades and removing fan and blades to store complete all as specified and as directed
Neptune Engineers and Builders
MS BUILDERS
M/s.Rejoy Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .