Tender Value
₹23.8 L
EMD Value
₹50,000
Closing Date
15 Jun 2020, 12:00 pmClosed
General Manager (Tech.) i/c
Travancore Titanium Products Ltd, P.B.No.1, Kochuveli P.O, Trivandrum- 21
Electrical works for VES Plant ,CRP Godown and CRP Additional Works at Travancore Titanium Products Ltd, Trivandrum- 21
2020_TTPL_350298_1
TTPL/PROJ/ELE-VES/RT/14/ 2019-20
Open Tender
Electrical Works
Item Rate
180 days
Travancore Titanium Products Ltd, Trivandrum- 21
Please refer Tender documents.
9 documents required · 9 mandatory
₹2,950
Yes
online
₹50,000
Yes
Travancore Titanium Products Ltd, Trivandrum- 21
18 Dec 2020
16 Mar 2020
18 Jun 2020
16 Mar 2020
15 Jun 2020
16 Mar 2020
16 Mar 2020 - 7 Apr 2020
26 Mar 2020
Amount
Laying and Jointing PVC Pipe. Heading
Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date.
3.5C 240sq mm Al
3.5C 70sq mm Al
3.5C 35sq mm Al
4C 16sq mm Al
4C 6sq mm Al
3C 2.5 Sq.mm Cu
4C 1.5 sqmm Cu
Supplying and making end termination with brass double compression gland and aluminium/Copper lugs for following size of XLPE insulated PVC sheathed aluminium/copper conductor cable of 1.1 kV grade as required.
3.5C 240sq mm Al(Flame Proof)
3.5C 70 Sq.mm Al
3.5C 35sq mm Al(Flame Proof)
4C 16sq mm Al
4C 6sq mm Al(Flame Proof)
4C 6sq mm Al
3C 2.5 Sq.mm Cu
4C 1.5 sqmm Cu
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Cable size upto 35sq mm
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Above 185sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Cable size upto 35sq mm
Above 185 sq.mm upto 400 sq.mm
Laying of one number additional PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Above 185 sq.mm upto 400 sq.mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Cable size upto 35sq mm
Above 185 sq.mm upto 400 sq.mm
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 kV grade of following size on cable tray as required.
Cable size upto 35sq mm
Above 35 sq.mm upto 95 sq.mm
Above 185 sq.mm upto 400 sq.mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.
Above 185 sq.mm upto 400 sq.mm
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
Fabrication, supply and installation of following size of ladder type FRPcable tray including horizontal and vertical reducers, tees, cross members and other accessories as required and duly suspended from the ceiling/wall with MS suspenders and painting etc as required
300mm WIDTH X 50mm DEPTH X 3mm THICK
150mm WIDTH X 50mm DEPTH X 3mm THICK
Supply, fabricating and installing MS items such as Tees/ angles/ channels etc. on floor/ ceiling/ wall including necessary civil work such as grouting, finishing etc. and painting with two coats of zinc chromate primer and two coats of enamel paint of approved make.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. The total distance from one point to another point will not exceed 5meters. In case if the total length increases 5meters, the wiring shall be measured under item 13.01)
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate,suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for group controlled (looped) light point/fan point/ exhaust fan point/ call bell point(without independent switch etc.) with 1.5 sq mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit and earthing the point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable etc as required.The total distance from one point to another point will not exceed 5meters. In case if the total length increases 5meters, the wiring shall be measured under item 13.01)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium steel conduit as required
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Group controlled light point with 1.5 sq. mm wire - Wiring for Group controlled light point (from one point to another point) with 3X 1.5 sq. mm PVC insulated, (FRLS), copper conductor cable in surface/recessed mounted rigid medium class 20mm PVC conduit with all accessories as required. ( Note: This item does not include the cost of MCB or 16Amp/ 6Amp one way switches. The total distance from one point to another point will not exceed 5meters. In case if the total length increases 5meters, the additional lengtth shall be measured under item 3.04. The distance from DB to 1st point will be measured under item point wiring.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing following modular switch/ socket with modular plate & cover on surface or in recess, including proving and fixing suitable size GI box,inter connection etc as required complete.
6 pin 15/16 amp socket outlet
15/16 amp switch
Supply & fixing Computer points with 3 nos 3 pin 5/6A socket with 2no.5/6A switch with modular front plate and cover on surface/recess, including proving and fixing suitable size GI boxs, its interconnections etc as required complete. (Note: 2 nos 5/6A socket fixed at 60cm above FFL and 2 nos 6A switch with 1no 5/6A socket at 1m above FFL)
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing following way, 3 phase vertical, fire retardent and acid proof, polycarbonate body, dust protected, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way (8 + 24), Double door
Supplying and fixing following way, 3 phase horizontal, fire retardent and acid proof, polycarbonate body, dust protected, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
4 way (8 + 12), Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
6 way (4 + 18), Double door
Supplying and fixing following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel,IP 54, IK 09 dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's, with provision of 125 amps TP 16 KA MCCB as incomer, interconnection between incomer MCCB and bus bars (but without MCB's/ MCCB) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
8 way, Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, IP54, IK 09, dust protected ,415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
6 way (4 + 18), Double door
4 way (4 + 12), Double door
Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
100Amp, 16 KA,FPMCCB
Supply and fixing of following rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required
4 pole 25 amps. (415 Volts),30mA sensitivity.
4 pole 40 amps. (415 Volts),30mA sensitivity.
4 pole 40 amps. (415 Volts),100mA sensitivity.
4 pole 63 amps. (415 Volts),100mA sensitivity.
Supply and fixing of following rating, 10 KA, Miniature Circuit Breakers as required.
6A to 32A, SP, B/C-CURVE
6 A to 32 A TP MCB, C-CURVE
6 A to 32 A SP MCB, D-CURVE
40 A to 63 A TP MCB, C-CURVE
Supply, installation, testing and commissioning of four pole 40A, 415V isolator in sheet steel enclosure withall accessories as required complete
Supply and fixing outdoor type START/STOP (2way) push button station (IP65) including all the necessary accessories as required complete with suitable mounting arrangement.(Cat No Hensel-PBS 0201 or equivalent approved make)
Supply installation, testing and commissioning of DOL starter upto 5HP, 3ph motor including auxilliary contactors, and all necessary accessories as required complete.
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,IP 66 enclosed plug top alongwith 20 amps "C" curve, SP, MCB, in the IP66 enclosure, on surface or in recess,complete with connections, testing and commissioning etc. as required. Make: Hensel TR 119 306 TS or equivalent approved make
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supply of industrial surface mounted LED batten and lamp with Poly Carbonate Body , along with driver , surge protector,system wattage of maximum 22W,lumen output of lamp greater than 1800 lumen, power factor >= 0.9, system efficacy greater than 90lumen/watt,cool day light and including all necessary accessories as required complete.Make:- Cat No: Crompton IGP131LT-8-16 housing+ 1nos of LTT8-20 LED or Wipro WIO 921208channel+ 1nos Proled T5 LL13-18165-T5 or equivalent approved make
Supply of outdoor IP 65 corrosion proof industrial LED fitting with driver , surge protector,system wattage of 40+/-4 Watts,lumen output of lamp greater than 4000 lumen, power factor > 0.9,rated life of L70 @ 50,000 hours, system efficacy greater than 100 lumen/watt and including all necessary accessories as required complete.Make:- Cat No: Wipro LE-20-491-XXX-57-XX or equivalent approved make
Supply of Highbay LED fixture with housing made of die cast Aluminium body with a high efficiency diffuser along with driver,system wattage 65+/-5 Watts,lumen output of lamp not less than 6000 lumens, power factor >= 0.9,rated life of L70 @ 50,000 hours, system efficacy greater than 95 lumen/watt, Cool day light fixture ,with suitable driver and including all necessary accessories as required complete.Make:- Cat No: Wipro LED Highbay LH-09-851-060-XX-V6 or equivalent approved make.
Supply of LED wellglass IP 65 luminaire with polycarbonate body along with driver, system wattage maximum of 70+/-5Watts, lumen output of lamp greater than 6500 lumens, powerfactor>0.9, rated life of L70 @ 40,000 hours. system efficacy greater than 95 lumen/watts including all necessary accessories as required complete.Make:- Wipro LE07-112or equivalent approved make
Supply of 2x2 LED recess mounted fixture with housing made of CRCA body with a high efficiency diffuser along with driver,system wattage 34+/-4 Watts,lumen output of lamp greater than 3500 lumens, power factor >= 0.9,rated life of L70 @ 50,000 hours, system efficacy greater than 95 lumen/watt, Cool day light fixture ,with suitable driver and including all necessary accessories as required complete.Make:- Cat No: CG LCTLRN-36-FO-CDL or equivalent approved make.
Supply of LED outdoor floodlight luminaire. The fixture shall be of IP66 protected, pressure die cast aluminium housing body with optimal heat sink, with system wattage less than 40 (+/-5)W with rated life of L70 @ 50,000 hours, CRI greater than or equal to 70 & with system lumens greater than 3500 lumen and system efficacy greater than or equal to 95%.Make Wipro LF19-471-060-57-XX or equivalent approved make
Supply of 400 mm size wall mounting oscillating type fan having three speed control, oscillation control at bottom and suitable for operation on single phase 230 volt, 50Hz AC supply complete with continuous duty motor, chrome plated front and rear gaurds and all accessories as required complete.(Make: CG Vortex air circulator 450mm or equivalent approved make).
Supply of following sizes of 1200 mm sweep. 5 star rated ceiling fan, with double ball bearing, Aluminium pressure die cast body with Aluminium blades, canopies, hanging shackle, 30 cm down rod and without speed regulator suitable for 240V 50 HZ, AC supply confirms to IS 374/1979 as required complete. (Make crompton-ENTRUST50 or equivalent approved make).
Supply of 450 mm sweep,900 rpm heavy duty exhaust fan in plastic body with self opening louvers working on 230 V AC supply complete with all accessories as required. (Make:Crompton EXHD450-4-1 or equivalent approved make)
Installation, testing and commissioning of pre-wired, LED/ fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of LED fittings with chain and copper wiring - Installation testing and commissioning of prewired fluorescent fittings of all types including LED complete with all accessories, lamps etc. on false ceiling including supplying and fixing of GI chain and hook arrangement, upto 60cm length, and wiring using 3 runs of 1.5 sqmm FRLS PVC insulated stranded copper conductor cable as required.
Installation, testing and commissioning of High bay/Mid bay/LED/ FLOOD type fittings on wall/Column/truss/false ceiling using suitable MS clamps, nuts, bolts/ 20mm heavy duty GI chain/ pipe (upto 50cm)etc including connections with 3C 1.5 Sq.mm PVC insulated flexible copper conductor cable as required.
Installation, testing and commissioning of Wall fan, including all the supports as required and wiring using 3 runs of 1.5 sqmm FR PVC insulated stranded copper conductor etc complete.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FRLSH PVC insulated, copper conductor, single core cable etc. as required.
Installation, testing and commissioning of exhaust fan upto 450mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connections, testing & commissioning etc as required.
Numbering of ceiling fan / exhaust fan/ fluorescent fitting as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing GI/Cu strip/wire on surface or in recess for connections etc. as required.
25mm x 6 mm GI
3.15mm Cu (10 SWG)
25mm X 3mm Cu
Supplying and laying following GI or copper strip(tinned at the points of contacts) / wire at 0.6m below ground level including excavation and refilling for conductor earth electrode including welding etc as required.
25mm x 6 mm GI
3.15mm Cu (10 SWG)
25mm X 3mm Cu
Supply and fixing of of fire retardant/extinguishing electrical insulated synthetic mat of 2m x 1m x 2 mm for 3.3kV grade thick, +/- 10% confirming to BIS: DOC No. ET-02 (5440) meeting requirements of IS:15652:2006 (with upto date amendment), suitable for 3.3kV voltage and having minimum width of 1000mm +/- 20mm and including supply of required quantity of adhensive / compound .
Supply and fixing single line diagram, schematic diagrams etc. of A1 size on suitable Aluminium sheet including lamination etc. as required complete on wall.
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Supply and fixing of 8 mm Aluminum Round Conductor as horizontal air terminal for parapet wall/terrace/roofing sheet with the required mounting clamps ,glue, cross connectors , expansion piece and other accessories required as per IEC 62305-3
Supply and fixing of 8 mm Aluminum Round Conductor as down conductor with the required mounting clamps , cross connectors , expansion piece and other accessories required as per IEC 62305-3
Providing and fixing of test joint suitable for hot dipped galvanized steel tape 32 mm x 3mm and 8mm dia solid round aluminium conductor made of stainless steel SS 304 grade. Conforms to the requirements according to (IS/IEC 62305).with an outdoor glass-fibre reinforced polycarbonate enclosure having minimum inner dimension of 75mm x 75 mm x 50 mm.
Providing and laying hot dipped galvanized steel tape 32 mm X3 mm from earth electrode directly in ground as required.
Supply, installation, testing and commissioning of 9m long Hot dipped GI pole painted with PU coat with built- in control box prewired, with pole suitable for mounting LED luminairie with lamp , concealed wiring with 3Cx 2.5 sq.mm copper wire from the control box to light fixture, and all other accessories. complete including necessary civil foundation. Along with LED Lamp with die cast Aluminium alloy housing and polycarbonate diffuser, inbuilt driver,system wattage maximum of 90(+/-10) watts, lumen outputnot less than 8500 lumen, System efficacy not less than 95 lumen per watt ,power factor >= 0.9, IP 66 compliant including all necessary accessories as required complete. Note:Incoming and outgoing cable at termination box shall be terminated with glands properly.(Pole Make : unique poles UELP012 or equivalent approved make. Luminairie Make: Wipro Skyline LR02-102-XXX-57-XX or equivalent approved make)
Leela Electricpower Services Pvt.Ltd
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .