Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L2₹23.3 L+₹59,463.97 (2.62%)Accepted-AOC VAIKOM RANNI P O 689 672 KERALA | PATHANAMTHITTA | KERALA | 689672 | L2 | Accepted-AOC Agreement executed | |
| 2 | L1₹22.7 LRejected-AOC | L1 | Rejected-AOC L1 | |
| 3 | L3₹23.8 L+₹1.1 L (4.77%)Rejected-AOC | L3 | Rejected-AOC L3 |
Tender Value
Refer Docs
EMD Value
₹35,310
Closing Date
4 Feb 2021, 6:00 pmClosed
EE LSGD
EE LSGD LSGD DIVISION JILLA PANCHAYAT PATHANAMTHITTA
JP PTA 322/21 Maintenance of Ayurveda Hospital Building under the control of District Panchayath
2021_LSGD_406614_4
10/2020-21/EE/LSGD/PTA
Open Tender
Civil Works - Buildings
Item Rate
365 days
Pathanamthitta
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,500
₹35,310
Yes
26 Jun 2021
23 Jan 2021
6 Feb 2021
23 Jan 2021
4 Feb 2021
23 Jan 2021
Amount
maintenance
13.48.1 : Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm
14.46 : Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
14.54.1 : Painting with synthetic enamel paint of approved brand and manufacture of required colour to an give even shade:One or more coats on old work
14.57.1 : Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade:One or more coats on old work
14.72 : Providing and fixing double scaffolding system (cup lock type) on the exterior side, upto seven story hight made with 40 mm dia. M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staricase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required location with essential safety features for the workmen etc. complete as per directions and approval of Engineer- in Charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. Note:- This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done .
14.76 : Cleaning and desilting of gully trap chamber, including removal of rubbish mixed withearth etc. and disposal of same, all as per the direction of Engineer-in-charge.
14.77 : Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operatedhigh pressure suction cum jetting sewer cleaning machine fitted with pump having4000 litres suction capacity and 6000 litres water jetting tank capacity including skilledoperator, supervising engineer etc. for cleaning and partial desilting of manholes anddechocking of sewer lines. Dechocking and flushing of sewer line from one manholeto another by high pressure jetting system of 2200 PSI for sewer line from 150mm diaupto 300mm dia for all depth.
14.78 : Cleaning of under ground sump, Over Head R.C.C. Tank ( independent staging)including disposal of slit and rubbish, all as per direction of Engineer-in-Charge. Thecleaning shall consist following operations:-(i)Tank shall be emptied of water by pumping & bottom shall be cleaned of slit andother deposits.(ii) Entire surface area of the sump shall then scrubbed thoroughly with wire brush etc.and pressure washed with water.(iii) Chlorination of RCC internal surface by liquid chlorine. (iv) The treated surface shall be dried using air jetting and all loose particles shall beremoval from the surface.(v) Finally the surface shall be treated with ultraviolet radiation etc. as per direction ofEngineer-in-Charge.
11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
51.18.12.7 : Providing and fixing G.I. pipes complete with G.I. fittings (Cost of fittings to be paid separately) External work - 65 mm nominal dia
51.19.ST4 : Supplying and installing ready made PVC Septic tank including the cost of carriage, trenching, placing at the level below ground level as specified as per the direction of engineer in charge (Provision for CC/RCC/Sand/06mm aggregate for the preparation of bed shall be paid separately)<br> 4. 35 to 50 flush capacity
10.16.1 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
od928753/2020_2021 : Providing and fixing 0.35mm thick tile profile/Trafford sheets roofing up to any pitchand fixing with polymer coated J, or L hooks, bolts and nuts 8mm dia. G.I. plain and bitumen washers or withself drilling fastener and EPDM washers etc. complete (excluding the cost of purlins, rafters and trusses),including cutting sheets to size and shape wherever required.
od928757/2020_2021 : Providing and laying 60mm factory made cement concrete interlocking paver block of M-30made by block making machine with strong vibratory compaction, approved size,design &shape ,laid in required colour and pattern over and including 50mm thick compacted bed coarse aggregate 6mm etc all complete as perthe direction of engineer in charge.
50.18.9.12.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 20 mm dia 10Kgf/cm2 External work- Exposed on wall
50.18.9.17.1 : Providing and fixing PVC pipes including fixing the pipe with clamps/ clip at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 6 Kgf/cm2 - External work - Exposed on wall
50.18.9.19.1 : Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall
50.18.9.19.2 : Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 m dia 4 Kgf/cm2 - External work - Exposed on wall
50.18.9.20.2 : Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -63 dia 45 degree Elbow
50.18.9.20.3 : Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Door Elbow
50.18.9.20.6 : Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -63x63x63 mm dia Door Tee
Ranny Taluk Labour Contract Co-operative SocityLtd
SUNICO CONSTRUCTIONS
Bidder Name
Ranny Taluk Labour Contract Co-operative SocityLtd
SUNICO CONSTRUCTIONS
SUDAN G
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_578096.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .