Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.6 LAccepted-AOC C 347 ARBUDHA NAGAR ODHAV AHMEDABAD | AHMEDABAD | AHMEDABAD | GUJARAT | 382415 | ₹26.6 L | L1 | Accepted-AOC AOC, being the lowest bidder |
| 2 | L2₹27.3 L+₹71,260 (2.68%)Rejected-Finance H NO 1 ARYA LANE SECTOR 13 HISAR HARYANA 125001 | HISAR | HISAR | HARYANA | 125001 | ₹27.3 L+₹71,260 (2.68%) | L2 | Rejected-Finance OTHER THAN THE LOWEST BIDDER |
| 3 | L3₹35.6 L+₹9.0 L (33.8%)Rejected-Finance 200 NAVAGAM NAVAGAM TA SAYLA SURENDRA NAGAR GUJARAT 363430 | SURENDRANAGAR | GUJARAT | 363430 | ₹35.6 L+₹9.0 L (33.8%) | L3 | Rejected-Finance OTHER THAN THE LOWEST BIDDER |
| Sl No | Description | Qty | Unit | Navkar Enterprises L1 | ARTI CONSTRUCTION L3 | MAHIPAL CONSTRUCTION COMPANY L2 |
|---|---|---|---|---|---|---|
| 1.00 | Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) complete all as specified and directed. | 7 | Cum | 800 ₹5,600 Lowest | 850 ₹5,950 | 800 ₹5,600 Lowest |
| 2.00 | M&L for PCC 1:2:4 type B1 (20mm graded aggregate) as in levelling course for slope correction of existing RCC roof surfaces including cleaning the roof surfaces amd removing existing APP based membrane removing all foreign materials by wire brushes/brooms/water jet complete all as specified and directed. | 2 | Cum | 7,600 ₹15,200 | 80,000 ₹1,60,000 | 6,500 ₹13,000 Lowest |
| 3.00 | M & L for water proofing treatment on existing cleaned RCC roof with following specification and manufacturer Instruction complete all as specified as directed.
(a) Applying bitumen primer confirming to IS-3384-1986 over the cleaned plaster surfaces as per IS-3067-1966.
(b) Applying a layer of APP based polymeric membrane 3.0mm thick (minimum) weighing 3.0 Kilogram per sqm (reinforced with polyster non oven fabric weighing not less than 160 Gmss per sqm by torch application. The over laps shall be minimum 100mm on the transverse direction and 75 mm on longitudinal direction.
(c) applying one coat of aluminium paint @ 0.10 Litre per Sqm Over APP based Polymeric membrane.
(d) Sealing of all angles & abutments upstands with extra care to ensure perfect bondage. Sealing of edges well into grooves & protect the seal with a polysulphide/polyurethane sealant.
Note:- water proofing treatment work must be carried out by an authorized applicator or as per direction of GE. | 1,525 | Sqm | 595 ₹9,07,375 Lowest | 640 ₹9,76,000 | 850 ₹12,96,250 |
| 4.00 | S&F in repair 110mm bore PVC (SWR) soil, waste and vent pipe, in any length, with rubber joints, laid in trenches or in floors complete all as specified and directed. | 100 | RM | 450 ₹45,000 Lowest | 455 ₹45,500 | 500 ₹50,000 |
| 5.00 | S&F in repair PVC (SWR) 110mm dia bend and double T equal or unequal at junctions of any radius complete all as specified and directed. | 20 | Each | 300 ₹6,000 Lowest | 320 ₹6,400 | 500 ₹10,000 |
| 6.00 | Taking up or down steel tubing 15mm bore and connections, including removing or removal to store complete all as specified and directed. | 20 | RM | 32 ₹640 | 30 ₹600 Lowest | 35 ₹700 |
| 7.00 | Taking up or down steel tubing 20mm bore and connections, including removing or removal to store complete all as specified and directed. | 100 | RM | 32 ₹3,200 Lowest | 310 ₹31,000 | 35 ₹3,500 |
| 8.00 | S&F 15mm GI tubes, medium grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. | 20 | RM | 300 ₹6,000 Lowest | 360 ₹7,200 | 340 ₹6,800 |
| 9.00 | S&F 20mm GI tubes, medium grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. | 100 | RM | 350 ₹35,000 | 90 ₹9,000 Lowest | 420 ₹42,000 |
| 10.00 | Taking down cement plaster of any description on brick or stone walls or concrete surfaces including raking out joints, hacking for key complete all as specified and as directed | 2,125 | Sqm | 85 ₹1,80,625 | 430 ₹9,13,750 | 50 ₹1,06,250 Lowest |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
16 Jun 2026, 6:00 pmClosed
GE (AF) Chiloda
GE (AF) Chiloda, LekawadaPatia, PO CRPF Campus, Gandhinagar (Gujarat)-382042
REPAIR / REHABILITATION TO CERTAIN OTM AND MD ACCN BLDGS AT AF STN WADSAR UNDER GE (AF) CHILODA
2026_MES_768071_1
8431/26-27/E8
Open Tender
Civil Works
Item Rate
180 days
WADSAR
As per Tender Documents
7 documents required · 7 mandatory
₹500
GE (AF) CHILODA
₹50,000
Yes
2 Sept 2026
26 May 2026
18 Jun 2026
26 May 2026
16 Jun 2026
10 Jun 2026
26 May 2026 - 9 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) complete all as specified and directed. | - | Cum | - | - |
| 2 | M&L for PCC 1:2:4 type B1 (20mm graded aggregate) as in levelling course for slope correction of existing RCC roof surfaces including cleaning the roof surfaces amd removing existing APP based membrane removing all foreign materials by wire brushes/brooms/water jet complete all as specified and directed. | 2 | Cum | - | - |
| 3 | M & L for water proofing treatment on existing cleaned RCC roof with following specification and manufacturer Instruction complete all as specified as directed.
(a) Applying bitumen primer confirming to IS-3384-1986 over the cleaned plaster surfaces as per IS-3067-1966.
(b) Applying a layer of APP based polymeric membrane 3.0mm thick (minimum) weighing 3.0 Kilogram per sqm (reinforced with polyster non oven fabric weighing not less than 160 Gmss per sqm by torch application. The over laps shall be minimum 100mm on the transverse direction and 75 mm on longitudinal direction.
(c) applying one coat of aluminium paint @ 0.10 Litre per Sqm Over APP based Polymeric membrane.
(d) Sealing of all angles & abutments upstands with extra care to ensure perfect bondage. Sealing of edges well into grooves & protect the seal with a polysulphide/polyurethane sealant.
Note:- water proofing treatment work must be carried out by an authorized applicator or as per direction of GE. | 1,525 | Sqm | - | - |
| 4 | S&F in repair 110mm bore PVC (SWR) soil, waste and vent pipe, in any length, with rubber joints, laid in trenches or in floors complete all as specified and directed. | 100 | RM | - | - |
| 5 | S&F in repair PVC (SWR) 110mm dia bend and double T equal or unequal at junctions of any radius complete all as specified and directed. | 20 | Each | - | - |
| 6 | Taking up or down steel tubing 15mm bore and connections, including removing or removal to store complete all as specified and directed. | 20 | RM | - | - |
| 7 | Taking up or down steel tubing 20mm bore and connections, including removing or removal to store complete all as specified and directed. | 100 | RM | - | - |
| 8 | S&F 15mm GI tubes, medium grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. | - | RM | - | - |
| 9 | S&F 20mm GI tubes, medium grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. | - | RM | - | - |
| 10 | Taking down cement plaster of any description on brick or stone walls or concrete surfaces including raking out joints, hacking for key complete all as specified and as directed | - | Sqm | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.40 MB
Tenderdocuments8431.pdf
Tender Documents • 0.94 MB
BOQ_860137.xls
BOQ • 5.88 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .