Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.4 LAdmitted-Finance H NO 159 VILL AND P O BHAUWALA NEAR S N PUBLIC SCHOOL RAJAWALA ROAD DEHRADUN UTTARAKHAND 248007 | DEHRADUN | UTTARAKHAND | 248007 | ₹9.4 L | L1 | Admitted-Finance |
| 2 | L2₹9.8 L+₹41,250 (4.40%)Admitted-Finance B 43 CIVIL LINES 1ST FLOOR NAYAPURA KOTA RAJASTHAN 324001 UDYAM RJ 24 0019224 08ABKPA3675N1Z9 R M | KOTA | RAJASTHAN | 324001 | ₹9.8 L+₹41,250 (4.40%) | L2 | Admitted-Finance |
| 3 | L3₹10.2 L+₹83,250 (8.87%)Admitted-Finance GROUND FLOOR LANE NO 5 SUBHASH NAGAR DEHRADUN U K 248 B O 286 PRAGATI NAGAR MEERUT | 248 | ₹10.2 L+₹83,250 (8.87%) | L3 | Admitted-Finance |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Others-EMD AND TENDER FEE NOT SUBMITTED |
| 5 | Not Admitted-Fee/PreQual/Technical NEAR TELEPHONE EXCHANGE BIJROL ROAD BARAUT U P PATEL NAGAR BARAUT 250611 DISTT BAGHPAT | BAGHPAT | UTTAR PRADESH | 250611 | - | - | Not Admitted-Fee/PreQual/Technical Others-EMD AND TENDER FEE NOT SUBMITTED |
| Sl No | Description | Qty | Unit | m/s star power solutions L3 | M/s Singhal and Co L2 | MSN CONSTRUCTION COMPANY L1 |
|---|---|---|---|---|---|---|
| 1.00 | (A) -Work of Patrolling of 132kV Bindal-Purkul Line (Tower to Tower) for one year, and submitting the Patrolling Report in prescribed Performa to Bindal Sub Division on quaterly basis in a year. Clearance of Patrolling Path by cutting & removing thorned bushes etc below the line in dense forest area & removing the same away from the 27 meter wide gallery. Checking Points are given as below:-
1. Position of disc insulator.
2. Identification and number of missing tower parts.
3. Dislocation of dampers.
4. Condition of the conductor & earth wire.
5. Identification of weak joints, deterioration of Jumpers, hot points and clamps etc.
6. Position of tower earthing & tower foundation.
7. Position of Danger plate, number plate and name plate . 8-Photography of Patrolling at each tower. Note-Report Submission by skilled Supervisor of Contractor. (11.5 KM X 4 Frequency = 46 KM) (B)-Lopping and chopping of trees and its branches near & under 132kV Bindal-Purkul Transmission lines in fields/crops by removing one by one all branches & stems developing towards the line & removing the same from the 27 meter wide gallery of the line safely with rope for safety of line conductors and to minimise future trippings. (quarterly basis in a year). | 46 | KM | 2,800 ₹1,28,800 | 1,500 ₹69,000 Lowest | 3,300 ₹1,51,800 |
| 1.01 | Cutting/Lopping and chopping of heavy dia tree including all labour and T&P etc. | 25 | No. | 2,600 ₹65,000 | 1,800 ₹45,000 Lowest | 3,000 ₹75,000 |
| 1.02 | Work of removing all the trapped waste material in river flood (During the monsoon season like wild bushes, poly bags, clothes, plastic rope, tree & metal wires from the first section of the tower No. 2C, 3C, 4C,5C, 7B, 8C, 9C, 10B, 17C, 18C,19C ,23B,24C,25B & 26 B of 132KV Bindal-Purkul line throw all the waste material away from the tower to safe place around 10 mtr. away from the tower location as direction of PTCUL repersentative. (15 JOB X 20 Frequency=300 Job) Note:- The Contractor will provide 06 person team (01 number Supervisor, 02 number skilled lineman and 03 number semiskilled labour) along with 01 number Jeep at 132kV Substation Bindal,Dehradun. All the required T&P and it's transporation will be provided by the contractor. Line T&P store of contractos must be located within 05 Km from 132kV Substation Bindal,Dehradun. | 300 | Job | 780 ₹2,34,000 | 1,900 ₹5,70,000 | 640 ₹1,92,000 Lowest |
| 1.03 | Thermography of Jumpers of 132kV Bindal-Purkul Line by thermal camera. (56KM X 2 Fqeuancy =112 KM) | 112 | km | 1,600 ₹1,79,200 | 1,000 ₹1,12,000 Lowest | 1,000 ₹1,12,000 Lowest |
| 1.04 | Emergency Patrolling and Lopping,chopping of 132kV Bindal-Purkul Line. | 11.5 | km | 2,500 ₹28,750 | 500 ₹5,750 Lowest | 2,600 ₹29,900 |
| 2.00SHUTDOWN/BREAKDOWN | ||||||
| 2.01 | Attending Emergency Breakdown/Replacement of damage/broken/punchure disc insulator of single/double suspension/tension fitting or Snapped/burnt/defective jumper of ACSR Panther conductor or earthwire fittings,including dismantling/lowering down and again hoisting complete string of 132kV Bindal-Purkul Line under 132kV S/s Bindal. | 1 | Job | 20,000 ₹20,000 | 5,000 ₹5,000 Lowest | 10,000 ₹10,000 |
| 2.02 | Replacement of Broken/defective/snapped ACSR panther conductor by using new STF/DTF,mid span joint/repair sleeve or earth wire complete accessories by using new earthwire of 7/10 SWG,complete work including De-stringing of above 132kV Bindal-Purkul Line. | 1 | Job | 30,000 ₹30,000 | 5,000 ₹5,000 Lowest | 15,000 ₹15,000 |
| 2.03 | Work of tightening of RYB phase jumpers of 132kV Bindal-Purkul line including all labour and T&P etc. | 168 | Nos | 2,000 ₹3,36,000 | 1,000 ₹1,68,000 Lowest | 2,100 ₹3,52,800 |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
25 Oct 2025, 6:00 pmClosed
SE O AND M CIRCLE DDUN
SE O AND M CIRCLE DDUN
Annual Maintenance Contract Preventive of 132 kV Bindal Purkul Transmission Line
2025_PTCUX_87797_1
T 38 SE O and M CR DDun 2025 26
Open Tender
Electrical Works
Item Wise
365 days
WORK
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
EE O AND M DIV YAMUNA COLONY PTCUL DEHRADUN
₹30,000
13 Nov 2025
3 Oct 2025
29 Oct 2025
3 Oct 2025
25 Oct 2025
3 Oct 2025
Amount
(A) -Work of Patrolling of 132kV Bindal-Purkul Line (Tower to Tower) for one year, and submitting the Patrolling Report in prescribed Performa to Bindal Sub Division on quaterly basis in a year. Clearance of Patrolling Path by cutting & removing thorned bushes etc below the line in dense forest area & removing the same away from the 27 meter wide gallery. Checking Points are given as below:- 1. Position of disc insulator. 2. Identification and number of missing tower parts. 3. Dislocation of dampers. 4. Condition of the conductor & earth wire. 5. Identification of weak joints, deterioration of Jumpers, hot points and clamps etc. 6. Position of tower earthing & tower foundation. 7. Position of Danger plate, number plate and name plate . 8-Photography of Patrolling at each tower. Note-Report Submission by skilled Supervisor of Contractor. (11.5 KM X 4 Frequency = 46 KM) (B)-Lopping and chopping of trees and its branches near & under 132kV Bindal-Purkul Transmission lines in fields/crops by removing one by one all branches & stems developing towards the line & removing the same from the 27 meter wide gallery of the line safely with rope for safety of line conductors and to minimise future trippings. (quarterly basis in a year).
Cutting/Lopping and chopping of heavy dia tree including all labour and T&P etc.
Work of removing all the trapped waste material in river flood (During the monsoon season like wild bushes, poly bags, clothes, plastic rope, tree & metal wires from the first section of the tower No. 2C, 3C, 4C,5C, 7B, 8C, 9C, 10B, 17C, 18C,19C ,23B,24C,25B & 26 B of 132KV Bindal-Purkul line throw all the waste material away from the tower to safe place around 10 mtr. away from the tower location as direction of PTCUL repersentative. (15 JOB X 20 Frequency=300 Job) Note:- The Contractor will provide 06 person team (01 number Supervisor, 02 number skilled lineman and 03 number semiskilled labour) along with 01 number Jeep at 132kV Substation Bindal,Dehradun. All the required T&P and it's transporation will be provided by the contractor. Line T&P store of contractos must be located within 05 Km from 132kV Substation Bindal,Dehradun.
Thermography of Jumpers of 132kV Bindal-Purkul Line by thermal camera. (56KM X 2 Fqeuancy =112 KM)
Emergency Patrolling and Lopping,chopping of 132kV Bindal-Purkul Line.
SHUTDOWN/BREAKDOWN
Attending Emergency Breakdown/Replacement of damage/broken/punchure disc insulator of single/double suspension/tension fitting or Snapped/burnt/defective jumper of ACSR Panther conductor or earthwire fittings,including dismantling/lowering down and again hoisting complete string of 132kV Bindal-Purkul Line under 132kV S/s Bindal.
Replacement of Broken/defective/snapped ACSR panther conductor by using new STF/DTF,mid span joint/repair sleeve or earth wire complete accessories by using new earthwire of 7/10 SWG,complete work including De-stringing of above 132kV Bindal-Purkul Line.
Work of tightening of RYB phase jumpers of 132kV Bindal-Purkul line including all labour and T&P etc.
M/s Singhal and Co (BID ID -403655)
m/s star power solutions (BID ID -403583)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.07 MB
TENDERDOCT38.pdf
Tender Documents • 0.57 MB
BOQ_104211.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .