Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.6 LAccepted-AOC | L1 | Accepted-AOC ok | |
| 2 | L2₹29.7 L+₹1.1 L (3.97%)Rejected-AOC | L2 | Rejected-AOC ok | |
| 3 | L3₹31.7 L+₹3.1 L (10.9%)Rejected-AOC BUNGALOW NO 21 CANTONMENT BAREILLY 243001 | BAREILLY | UTTAR PRADESH | 243001 | L3 | Rejected-AOC ok |
Tender Value
₹32.9 L
EMD Value
₹65,700
Closing Date
13 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE WEST BAREILLY
GE WEST BAREILLY
PROVN OF CERTAIN E/M SANCTIONED WORKS UNDER GE (W) BAREILLY
2021_MES_468002_1
8980/C/E8
Open Tender
Civil Works
Item Rate
180 days
GE WEST BAREILLY
SCANNED COPY OF ENLISTMENT LETTER IN MES IN RELEVANT CLASS CATEGORY SCANNED COPY OF APPLICATION ON LETTER HEAD OF FIRMSCAN COPY OF DD OF RS 500.00 IN FAVOUR OF GE WEST BAREILLY FROM ANY NATIONALISED OR SCHEDULED BANK SCANNED COPY OF REGISTRATION
6 documents required · 6 mandatory
₹500
Yes
GE WEST BAREILLY
₹65,700
Yes
28 Sept 2021
14 Aug 2021
15 Sept 2021
14 Aug 2021
13 Sept 2021
31 Aug 2021
14 Aug 2021 - 30 Aug 2021
60 days
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in hard/dence soil for laying of LT UG cables/base for Pole etc complete.
Returning, filling in, including spreading levelling, watering and well ramming in layers not exceeding 25 cm thick in hard/dense soil
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point
M&L for sand cushioning laid in trenches for laying of LT UG cables complete
M&L Modular bricks common burnt clay building bricks, sub-class ‘B’ designation-75 for LT UG cable protection complete
Supply and laying & testing UG cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm, 4 core Make- Havells/Kalinga/Paragan/Gloster
All as per Item No- 6 here in before but conductor of size 25 sq mm, 3.5 core
All as per Item No- 6 here in before but conductor of size 95 sq mm, 3.5 core
All as per Ser item No 6 here-in-before but 185 Sq mm 3.5 core
S&F Multi Core Round PVC Insulated Copper Conductor (Flexible), industrial cables PVC Sheathed Cables Nominal area of conductor 1.50 Sqmm, 2 Core, 1100 volts to IS: 694 Make- Havells/Kalinga/Polycab/Finolex
Supply and errection of Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-22 (9 metres long)
Cement concrete in foundations,filling and mass concrete Type C2 1:3:6, 40 mm graded aggregate for foundation for LT Panel/POLE
Supply and fixing LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion esistant including thermal management in multiple optics complete with IP 65/66 protection complete.
M & L for installation, commissioning and testing factory made CPRI approved out door junction box300x250x200mm cubical type fabricated with 2mm thick CRCA sheet (Heavy duty) over a frame of 25 x 25 x 4mm angle iron all around and dust & vermin proof, IP-65 protection, back side openable, fixed with nuts & bolts and front side openable with hinged shutter and locking arrangement by operate alen key individuals and over all front panel double door shutter with powder coated finished both internally and externally suitable for 415 V, AC, 50 HZ, 3 Phase, 4 wire system by means of AL bus bar of size 50 x 6mm (Main) duly wrapped with coloured insulating tape/ sleeves mounted on porcelain insulators with provision for incoming and outgoing lighting cables conection duly crimping with suitable size copper lugs complete.
S&F GI tubes light grade of dia 40mm with all fitting and fixed complete for protection of LT UG Cables laid to walls or in floors or along with poles etc Make- Jindal/Parkash/TATA
Supply and fixing of street light bracket made out of 40 mm dia GI tubing medium grade made to shape 1.5 mtr long incl duly painted with synthetic aluminium paint over a coat of primer Note:-MS clamps and back plates fabricated from steel section including nuts, bolts, washers items required shall be measured and paid separately *(Rates 411x1.50RM=616.50) for each Complete all as specified and directed. Make- Jindal/Parkash/TATA
M&L Bracings, supports, clamps and chequered steel back plates, angle iron equal size or any size fabricated from steel section including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape or size etc as indicated or directed and duly painted with synthetic enamel aluminium/smooke grey paint over a coat of primer complete
M & L for installation, commissioning and testing factory made CPRI approved out door junction 1000x750x300mm cubical type fabricated with 2mm thick CRCA sheet (Heavy duty) over a frame of 50 x 50 x 4mm angle iron all around and dust & vermin proof, IP-65 protection, back side openable, fixed with nuts & bolts and front side openable with hinged shutter and locking arrangement by operate alen key individuals and over all front panel double door shutter with powder coated finished both internally and externally suitable for 415 V, AC, 50 HZ, 3 Phase, 4 wire system by means of AL bus bar of size 50 x 6mm (Main) duly wrapped with coloured insulating tape/ sleeves mounted on porcelain insulators with provision for incoming 100 Amp MCCB and TWO no of out going nature timer witch control streat light complete with wiring of cap 12 KW 3 phase outgoing complete .
M&L for Boring of holes under road /pavement/hard standing or any other situation by mannual means for 80/50 mm bore at the depth not less than 1 mtr below ground level for crossing the cable and making good both the ends all as specified and directed at site. Note :- GI pipe shall be measure and paid separately under respective item.
Taking down of old aluminium conductor/ hanging service mains any description /size from LT Poles, Panel including dismantling cross arms, bracing and other steel accessories complete all as specified and as directed..
Taking down of old hanging service mains and LT cables of any description , any size from LT Poles, Panel including dismantling cross arms, bracing and other steel accessories complete all as specified and as directed..
Supply and fixing Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp.
Supply,installing,commissioning and testing of LT feeder pillar outdoor type of size 2000 x 1500 x 600mm CPRI certified factory made cubical type weather and vermin proof fixed on and including ventilation and louvers arrangement PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in foundation of required/suitable size and as directed at site with angle iron frame of size 70x70x6mm, 3 phase 4 wire 415 volts 50 HZ fabricated out of 3.15 mm thick CRCA sheet steel including duly powder coated painted and keeping adequate working space inside of the box (outer width of the box not less than 45cm and gap between bus bar not less than one inch) and double door handle including locking arrangement wih 1 No pad lock of 65mm as directed before manufacturing the panel. Including dismantling/ disconnection of old rusted LT panels with accessories. The drawing of the feeder pillar box will be approved by Engr-in-Charge and the same have the following electric controls :-
Insulated epoxy coated high conductivity aluminium bus bar 630 Amps (Size 60mmx6mm thick) for phase and neutral complete all as specified and directed.
(A) incoming
On load Change Over Switch 300 Amp
MCCB 250 Amp 35KA, 4 pole, 415 volts 50 Hz adj thermal & magnetic setting – 01 No.
(B) Outgoing
MCCB 200 Amp 25KA, 4 pole, 415 volts 50 Hz adj thermal & magnetic setting (As out going) – 01 Nos.
MCCB 100 Amp 16KA, 4 pole, 415 volts 50 Hz adj thermal & magnetic setting (As out going) – 05 Nos.
LED Indicating lamp assembly R,Y,B Phase – 06 Set
M & L for fabrication of MS busbar chamber of nominal dimension 900 mm x 600 mm x 400 mm duly provided with aluminimum busbar of size 50 mm x 6mm dixed on porcelain insulators TPN type out door weather/vermin proof with both way opening duly provided with neoprene rubber gasket along the doors openings pedestal type duly painted powder coated on CRCA steel sheet encloser 3.15mm thick with one No incommer MCCB 100 Amp 16 KA complete all as sepcified and directed incl making connection /thimbles etc complete.
M&L for earthing complete with galvanised or steel earth plate electrode of size 60cm x60cmx6mm thick burried directly in ground vertically ( to a depth not less than 2.25mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to strip 32x 6 mm size with nuts, bolts , check nuts , washers, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick all around, top & bottom watering pipe 20mm bore of GI medium grade with funnel and wiremesh all as shown in electrical plate No. 5 of SSR -1991 Part I and connecting to arthing test point,main switch board and testing on completion including PCC chamber concrete 1:3:6 type C-2 and RCC cover 75mm thick with MS TMT bar 8mm dia @ 150mm c/c both ways in cement concrete(1:2:4) type B-1 all asshown in electrical plate in No 5 of SSR(Pt-I)1991 complete all as specified and dirfected by Engineer-in-charge.
Supply and fixing/laying of galvanized iron strip of size 32x6 mm as earth continuity conductor provided in between earth test point terminal and upto the equipment incl nuts, bolts and washers complete all as specified and directed.Note: Making of earth test point is also included in the quoted rate.
Supply and errecting, in truly vertical position, HT steel tubular swaged poles 11 mtrs long with CI base plate, finial taper plug, bolts, nuts and screws as specified, type 410,SP-55, including painting of poles with two coats of aluminium paint and synthatic enamel paint in black and white strips upto 1.5 mtr height from coping over a coat of red oxide primer including numbering of poles with provision of four lights connected to a ring with nuts ,bolts ,clamps of suitable heavy grade GI pipe complete all as directed by Engineer in charge. Note : PCC, Earth work will be measured and paid separately.
S & F security flood light with PDC aluminium housing with sealed toughned glass cover SMD LED 180 W with secondary lens 150 Watt complete all as specifies and directed.
M&L for concealed type wiring for one light/ fan/ bell point controlled by one switch with1.5 Sqmm (Nominal area) PVC insulated, unsheathed, stranded copper, conductor cable (1100Volts grade) FRLS,ISI marked, drawn in and including rigid PVC conduits ,20/25 mm dia all as directed with all fittings and accessories alongwith PVC insulated cable with solid copper conductor of size 1.5 Sqmm as earth continuity conductor including fixing of 2mm thick MS sunk terminal box duly flushed to wall with 3mm thick plastic laminated/ebonite sheet cover fixed with brass screws,cap and washers incl. making good the disturbed surfaces complete all as below:-
(a) One exhaust fan point controlled by one switch.
All as per item 29 here in before but for one 15 Amp 6 Pin switch socket out let independent with 2.5 Sqmm FRLS (Nominal Area) PVC unsheathed copper conductor single core multistranded complete all as specified.
S&Fswitch piano type 15 Amp flush type 240 Volt complete.
S&Fsocket out let 6 Pin 2 in 1, 5/15 Amp flush type 240 Volt complete.
S&F MCB SPN 63 Amp 240 volt complete all as specified and directed by the Engr-in-Charge.CAT No. CSMBS1B40/63 N of Make C&S or equivalent in Legrand/ Scheneider.
S&F MCB single pole 6 to 32 Amp 240 Volt 'B' curve 10 KA complete all as specified and directed by the Engr-in-Charge.CAT No. CSMBS1B6-32 of Make C&S or equivalent in Legrand/ Scheneider.
Supply and fix flush sheet metal enclosure SPN DB 4 way with double door IP-42 protection detachable gland plates, flush mounting for MCB fitted with bus bar , earth bar and neutral links Cat part No CSDBSPNSD04 ofof C&S or Equivalent Model in Legrand / Schenieder as Approved by GE complete including taking down old unsv all as specified and directed.
Supply and Fix water heater storage type, electric, capacity 25 litr.BEE 5 star
M &L for GI water tubing medium grade laid in trenches/on well etc with running fittings complete of following sizes :-
(a) 20 mm dia
S&F gun metal gate vlave with iron wheel head, both ends screwed of following sizes
(a) 20 mm dia
M & L cutting of existing CI/GI pipe line for taking branch connectiong by necessary cutting/weilidng work, providing GI fittings such aa tee/reducers etc upto 25 mm bore complete necessary earth work complete all as directed at site.
Supply and fixing 1100 volt grade heavy duty cable PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connectious suspended by insulating hangers not more than 1 meter apart including 4 mm dia suspension wire, one twin core cable flat of size 10 sqmm all as specified.
Supply and fix flush sheet metal enclosure SPN DB 8 way with double door IP-42 protection detachable gland plates, flush mounting for MCB fitted with bus bar , earth bar and neutral links Cat part No CSDBSPNSD04 ofof C&S or Equivalent Model in Legrand / Schenieder as Approved by GE complete including taking down old unsv all as specified and directed.
Material & Labour for earthing complete including taking out old unsv and replace with galvanised steel earth plate 600x600x 6mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 meters below normal ground level, surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate using 4 mm dia GI wire as earth wire electrode moulded and rivetted to earth plate at one end and connected to main switch/ control switches of buildings at another end, GI earth wire encased in and including 15 mm dia GI 'light grade' pipe from upper end of earth plate upto main switch board of building including 20 dia bore GI pipe 'light grade' as water pipe from earth chamber and including excavation and earth work, PCC 1:3:6 type C1 chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced all as specified
S&F switch piano flush type 5 Amp single pole one way.
Supply and Fixing ceiling rose PVC / Poly carbonate, Isolated body, three terminal AC 230 volts complete all as specified and directed.
Suuply, fixing and testing iron exhaust fan of size 300 mm , 230V AC type of make- havells/Crompton/Surya complete all as specified and directed by Engr-in-Charge
M&L for cutting wall and make sutable size hole for fixing exhaust fan and repair & finishing wall after fixing exhaust fan all as directed by Engr-in-Charge.
Notes:-
M/S HINA ELECTRICALS
prabhave traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .