| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | H1₹5.7 LAccepted-Finance | ₹5.7 L | H1 | Accepted-Finance Qualified. |
| 2 | H2₹5.0 L−₹65,815 (11.6%)Accepted-Finance 00 AGRA AGRA UTTAR PRADESH 282001 | AGRA | UTTAR PRADESH | 282001 | ₹5.0 L−₹65,815 (11.6%) | H2 | Accepted-Finance Qualified. |
| 3 | H3₹4.9 L−₹76,550 (13.5%)Accepted-Finance | ₹4.9 L−₹76,550 (13.5%) | H3 | Accepted-Finance Qualified. |
| Sl No | Description | Qty | Unit | Pawan Kumar H2 | Bhanu Pratap H1 | RAHUL GAUTAM H3 |
|---|---|---|---|---|---|---|
| 1.00Construction of Fish Processing Unit at Trout Fish Farm patlikuhal Distt Kullu (H.P) (SH-: Providing Air Curtain,metal duct & E.I therein) | ||||||
| 1.01 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copperconductor single core cable etc as required.(a) Group-C as directed by engineer in charge | 61 | Point | 1,050 ₹64,050 | 1,200 ₹73,200 | 800 ₹48,800 Lowest |
| 1.02 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.Make:-ANCHOR as directed by engineer in charge | 10 | Each | 340 ₹3,400 Lowest | 500 ₹5,000 | 400 ₹4,000 |
| 1.03 | Supplying and fixing suitable size GI box with modular plate and cover in FRLS on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.Make:-ANCHOR as directed by engineer in charge | 4 | Each | 450 ₹1,800 | 500 ₹2,000 | 400 ₹1,600 Lowest |
| 1.04 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed heavy class PVC conduit having wall thickness 2.0mm as required Plaza 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire as directed by engineer in charge | 160 | Rmtr | 140 ₹22,400 | 140 ₹22,400 | 100 ₹16,000 Lowest |
| 1.05 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed heavy class PVC conduit having wall thickness 2.0mm as required Plaza2 X 4 sq. mm + 1 X 4 sq. mm earth wire as directed by engineer in charge | 80 | Rmtr | 220 ₹17,600 | 240 ₹19,200 | 200 ₹16,000 Lowest |
| 1.06 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed heavy class PVC conduit having wall thickness 2.0mm as required Plaza 4 X 6 sq. mm + 2 X 6 sq. mm earth wire as directed by engineer in charge | 80 | Rmtr | 550 ₹44,000 Lowest | 680 ₹54,400 | 600 ₹48,000 |
| 1.07 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed heavy class PVC conduit having wall thickness 2.0mm as required Plaza4 X 16 sq. mm + 2 X 6 sq. mm earth wire as directed by engineer in charge | 5 | Rmtr | 1,050 ₹5,250 Lowest | 1,300 ₹6,500 | 1,200 ₹6,000 |
| 1.08 | Supplying and fixing batten/ angle holder including connection etc. as required. Make:-Anchor as directed by engineer in charge | 21 | Each | 50 ₹1,050 Lowest | 60 ₹1,260 | 50 ₹1,050 Lowest |
| 1.09 | Supplying and fixing 6 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Make:-L&T as directed by engineer in charge | 18 | Each | 200 ₹3,600 Lowest | 240 ₹4,320 | 200 ₹3,600 Lowest |
Tender Value
₹6.5 L
EMD Value
₹13,050
Closing Date
18 Apr 2026, 10:30 amClosed
Chief Executive Officer HPAFMS
Directorate of Fisheries HP Bilaspur
Construction of Fish Processing Unit at Trout Fish Farm patlikuhal, Distt. Kullu (H.P) (SH Providing Air Curtain, Metal duct and E.I therein).
2026_HAFMS_133315_1
2026_HPAFMS_1959_1
Open Tender
Electrical Works
Item Rate
90 days
Patlikuhal Distt. Kullu H.P.
Please refer Tender documents.
5 documents required · 5 mandatory
₹350
Chief Executive Officer HPAFMS
₹13,050
18 Apr 2026
4 Apr 2026
18 Apr 2026
4 Apr 2026
18 Apr 2026
4 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Construction of Fish Processing Unit at Trout Fish Farm patlikuhal Distt Kullu (H.P) (SH-: Providing Air Curtain,metal duct & E.I therein) | |||||
| 1.01 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copperconductor single core cable etc as required.(a) Group-C as directed by engineer in charge | 61 | Point | - | - |
| 1.02 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.Make:-ANCHOR as directed by engineer in charge | 10 | Each | - | - |
| 1.03 | Supplying and fixing suitable size GI box with modular plate and cover in FRLS on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.Make:-ANCHOR as directed by engineer in charge | 4 | Each | - | - |
| 1.04 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed heavy class PVC conduit having wall thickness 2.0mm as required Plaza 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire as directed by engineer in charge | 160 | Rmtr | - | - |
| 1.05 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed heavy class PVC conduit having wall thickness 2.0mm as required Plaza2 X 4 sq. mm + 1 X 4 sq. mm earth wire as directed by engineer in charge | 80 | Rmtr | - | - |
| 1.06 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed heavy class PVC conduit having wall thickness 2.0mm as required Plaza 4 X 6 sq. mm + 2 X 6 sq. mm earth wire as directed by engineer in charge | 80 | Rmtr | - | - |
| 1.07 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed heavy class PVC conduit having wall thickness 2.0mm as required Plaza4 X 16 sq. mm + 2 X 6 sq. mm earth wire as directed by engineer in charge | 5 | Rmtr | - | - |
| 1.08 | Supplying and fixing batten/ angle holder including connection etc. as required. Make:-Anchor as directed by engineer in charge | 21 | Each | - | - |
| 1.09 | Supplying and fixing 6 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Make:-L&T as directed by engineer in charge | 18 | Each | - | - |
stage.html
html • 0.04 MB
technical_197141.pdf
techsummary_197141.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.33 MB
Tendernotice_2.pdf
PDF • 2.12 MB
Tendernotice_3.pdf
PDF • 36.79 MB
BOQ_197141.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .