| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹81,233.69Accepted-AOC | L1 | Accepted-AOC AS THE AMOUNT QUOTED IS LOWEST AND GENUINE IN SINGLE RE ETENDER THE CONTRACT IS AWARDED TO SASI.T | |
| 2 | L2₹81,840.11+₹606.42 (0.75%)Rejected-AOC | L2 | Rejected-AOC SECOND LOWEST |
Tender Value
₹81,840
EMD Value
₹2,046
Closing Date
24 Jan 2024, 12:00 pmClosed
RAJY K M
OFFICE OF THE ASSISTANT ENGINEER LSGD SECTION CHERUVANNUR GP
Annual Plan Cheruvannur GP Project No 116 Thadathil Meethal Colony DWSS Installation of pump set General Electrical Work
2024_LSGD_642656_1
28/AE/LIDEW/CNR/3/23-24
Open Tender
Electrical Works
Item Rate
270 days
LSGD SECTION CHERUVANNUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹555
Yes
₹2,046
Yes
24 Feb 2024
15 Jan 2024
25 Jan 2024
15 Jan 2024
24 Jan 2024
15 Jan 2024
Amount
SITC pump set and Electrification
OD362393/2022-2023:Supply and providing LED indicator lamp (Red, Green, Black, Yellow, Orange colours) in the existing panel board and giving connection
OD362394/2022-2023:Supply and providing LED indicator lamp (Blue colour) in the existing panel board and giving connection
2.10.3:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
OD362395/2022-2023:Supply and providing Danger 415 V, 150 X 100 mm Enameled danger plates
90.2.1.1:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point
90.2.1.6:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points
OD362396/2022-2023:Supply, Conveyance, Installation and testing of robust & reliable LED Bulk head with IP65 Protection and IK08 impact resistance suitable for wall mounting application including giving connection as required. (Make: Philips (Model: WT140W LED7S CW PSU S1 PC-9405) or any other equivalent make
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
OD362397/2022-2023:Supply and providing 2x25x3 mm G I strip as test joint on the existing watering pipe of earthing including bending and giving connections
OD362398/2022-2023:Providing and fixing 25mmx3mm GI Strip on surface or in recess for connections etc as required
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
OD362399/2022-2023:Supply and providing 25x6mm brass nut and bolt etc. as required.
OD362400/2022-2023:Supply & installation of dust and vermin proof, 3 Phase Sintex Meter Board size 650x350x170mm (6535)to fix KSEB meters, fuse units, CT inciuding necessary B&N, rubber bushes etc.as required including fixing it on wall, making good the damages colour washing etc. as required.
OD362401/2022-2023:Supply and providing 32A 2 way neutral link on existing meter board using suitable nut ,bolt etc. as required.
OD436570/2022-2023:Supply and providing 32A HRC fuseholder with suitable nut,bolt etc.
OD362403/2022-2023:Supply and providing 20-63A offset staggered HRC fuse link
90.6.10.3:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required32 mm
1.17.22:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 4 sq. mm
90.6.6.2:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.2.50 sq mm
OD362404/2022-2023:Supply and fixing 50mm (2") GI flange in the existing suction/delivery pipe line using required leak proofing materials etc. as required
OD362405/2022-2023:Supply and fixing clamp made with 50x6mm MS Flat for hanging delivery pipe of submersible motor pump set in existing GI pipe above the open well
OD362406/2022-2023:Supply and fixing 50mm B class GI pipe as support for hanging submersible motor pump set in open well
OD362407/2022-2023:Supply and fixing 63mm PVC threaded adaptor male
OD362408/2022-2023:Supply and fixing 63mm PVC pipe 6kgf/cm2
OD362409/2022-2023:Supply and providing suitable stranded Steel rope for hanging the 10HP submersible motor pump set
OD362410/2022-2023:Supply, installation, testing and commissioning of 2 1/2" Cast Iron Non Return Valve in the existing PVC/ ASTM pipe
OD362411/2022-2023:Supply and fixing 50mm 80 Sch ASTM Threaded Adaptor Male
OD362412/2022-2023:Supply and fixing 50mm 80 Sch ASTM Tee
OD362413/2022-2023:Supply and fixing 50mm 80Sch ASTM bend
OD362414/2022-2023:Supply, laying and fitting 50 mm 80 Sch ASTM pipe with suitable type solvent etc. as required at site,
OD362415/2022-2023:Supply and fixing 50mm ASTM socket 80 Sch
OD436568/2022-2023:Supply and fixing pump controller suitable for 3 Phase 10 HP Open well submersible motor pump set complete with DOL starter, single phasing preventer, ON OFF indication lamps, push buttons, volt meter and ammeter etc. in sheet steel enclosure duly wired in the existing panel board and giving connection etc. as required. LT LK make MU-G10 DOL or equivalent
OD362418/2022-2023: Supply and fixing 50mm GM Non Return valve in the existing ASTM/GI pipe
OD362419/2022-2023:Supply and fixing 50mm GM Ball valve in the existing ASTM pipe Zoloto make or equivalent
SASINDRAN E
Bidder Name
SASINDRAN E
SASI T
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_982994.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .