Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.2 LAccepted-AOC D NO 71 31 96 6 ASRR COLONY MALKAPURAM POST VISAKHAPATNAM 530 011 | VISAKHAPATANAM | ANDHRA PRADESH | 530011 | L1 | Accepted-AOC 1st Lowest | |
| 2 | L2₹36.7 L+₹1.8 L (5.20%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | Rejected-Technical | - | Rejected-Technical Since the contractor not enlisted in requisite category and not submitted similar work experience |
Tender Value
₹37.1 L
EMD Value
₹74,200
Closing Date
6 Jun 2023, 6:00 pmClosed
Garrison Engineer P Navy Kalinga Visakhapatnam
Garrison Engineer P Navy Kalinga Military Engineer Services INS Kalinga PO Visakhapatnam 531 163
SPECIAL REPAIRS/REPLACEMENT OF APFC PANEL AT SUB STATIONS OF TP AREA AND NON TP AREA AT NAD BHEEMUNIPATNAM AND PROVISION OF 02 NOS LMG OUTPOSTS, DHOBI GHAT, STABILIZED POWER SUPPLY FOR NCN EQUIPMENTS HELD AT IT ROOM AND FALSE CEILING FOR INDUSTRIAL C
2023_MES_594101_1
GE (P)/N/K/8995 OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer P Navy Kalinga Visakhapatnam
Class D, Category a(i), b(i)
6 documents required · 6 mandatory
₹500
Garrison Engineer P Navy Kalinga Visakhapatnam
₹74,200
Yes
10 Jul 2023
9 May 2023
8 Jun 2023
9 May 2023
6 Jun 2023
23 May 2023
Amount
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft/ loose soil complete all as directed.
Excavation over areas not exc 1.5m deep and getting out in hard/dense soil complete all as specified and as directed.
All as per Srl Item No. 2 here-in-before but for exc 1.5 mtr and n exc 3.0 mtr depth
Excavation in trenches n. exc 1.5 mtr wide and n. exc 1.5 mtr in depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, FRLS cable etc. n.exc 10 Sqm on plan and n.exc 1.5m in depth and getting out in soft /loose soil complete all as specified and as directed.
Removing excavated material/Soil to a distance n. exc. 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed by the Engineer-in-Charge.
M & L Plain cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete, bed etc complete all as specified and as directed.
M&L PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in surface channels, drain etc finishing the top surface even and smooth without using extra cement complete all as specified and as directed.
M&L for PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in coping including weathering, slightly rounded or chamfered angles complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick using soft/loose soil obtained from excavation. complete all as specified and as directed by the Engineer-in-Charge.
M & L reinforced cement concrete M-30 (Design Mix Concrete) using 20mm graded aggregate as in footings, plinth beams, and the like complete all as specified and as directed.
M & L reinforced cement concrete M-30 (Design Mix Concrete) using 20mm graded aggregate as in columns and pillars complete all as specified and as directed.
M&L for Reinforced Cement Concrete M-30 (Design Mix Concrete) (Using 20mm graded granite stone aggregate) in lintel beams, roof beams and the like etc complete all as specified and directed.
M & L reinforced cement concrete M-30 (Design Mix Concrete) using 20mm graded aggregate as in slab supported on walls and the like complete all as specified and as directed.
Use and waste of form work to sides of concrete foundations, footings, bases of columns, rafts and raft beams, sided and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished flat surface of concrete completed all as specified and as directed.
Use and waste of form work to sides of columns and pillars for fair finished surfaces complete all as specified and directed.
Use and waste of form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressumers, lintels, cantilevers, shelves including supports, overhangs, etc also splays between floors and beams finished rough surfaces of concrete complete all as specified and as directed.
Use and waste of formwork to soffits of suspended slab such as roof slabs floor slab, landing and similar work not exceeding 200mm thick (Horizontal or sloping) in flat rough finished surface at concrete complete all as specified and as directed.
M & L for TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M & L for TMT steel bars 6 to 8mm dia , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M & L for TMT steel bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L Brick work with fly ash bricks straight or curved on plan exc 6.0 mtr mean radius built in cement mortar (1:6) complete all as specified and as directed
M&L for moorum or red bajri filling in floors or pavings, laid in layers n exc 15 cm thick, spread, levelled and rammed including watering complete all as specified and as directed.
M & L 75 mm thick PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in sub base/ floor, complete all as specified and directed.
M&L for 40 mm thick plain cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in floor finishing with using extra cement complete all as specified and as directed.
M&L for rendering 10 mm thick with CM 1:6 on internal plastered surfaces of fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M&L 15 mm thick rendering on fair faces of brick/concrete surfaces in cement mortar 1:4 in two layers of 10mm thick and 5mm thick, finished fair and smooth and water proofing compound shall be added on top layer as per manufacturer instruction complete all as specified. (Note :- WPC will be measured and paid separately under appropriate item as supply only).
M&L for rendering 5 mm thick on fair faces of concrete surfaces of ceilings in CM 1:3 and finished even and smooth with out using extra cement complete all as specified and directed by the Engineer-in-Charge.
Supply only Integral Water Proofing Compound (ISI marked) of approved make.
M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer on internal surfaces of walls .
M&L for preparation of new external surfaces of walls and applying two coats of cement based paint over a coat of primer on external surfaces of walls .
M&L for preparation of new plastered surfaces of ceiling and applying two coats of white wash complete all as specified and as directed by the Engineer-in-Charge.
S & F powder coated aluminium frame for doors, windows, ventilators with one or more rebates including jointing cleat for fixing etc, (minimum thickness of powder coating 50 micron) complete all as specified and as directed.
S&F anodised powder coated aluminium window and ventilator shutters, sliding type without sash bars, aluminium sections including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws and suitable anodised aluminium handles and rollers complete all as specified (minimum thickness of powder coating 50 micron) complete all as specified and as directed by the Engineer-in-Charge.
M & L rendering 15mm thick on fair faces of brick wall or concrete surface in cement mortar 1:3 with water proofing compound complete all as specified and as directed.
M&L for normal water proofing treatment on roof slab portion consisting with the following operation : (i) Cleaning surface by wire brushes broom, removing dust and applying with bitumen primer conforming to IS 3384-1986 @ 0.50 kg per sqm (ii) Applying a tack coat of bitumen 85/25 @ 1.2 kg per sqm for water proofing membrane (iii) Applying of polymeric water proofing membrane weight not less than 3 kg per sqm over entire area with overlapping and sealed complete all as specified and as directed. (iv) Again applying hot bitumen 85/25 @ 1.2 kg per sqm over water proofing membrane (v) Applying a bituminous aluminium primer/ paint 0.10 kg per sqm complete all as specified and as directed.
S&F framed work such as grills, grating, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars, barred iron doors, ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 Gde E-165 complete all as specified and as directed.
M&L for 75mm thick PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in plinth protection/ sub base and paving finished cement concrete surfaces even and fair without using extra cement .
S&F 5.5 mm thick sheet glass, ordinary quality and glazing with oil putty in square exc. 0.5 Sq.m. in each pane complete all as specified and as directed by the Engineer-in-Charge.
S&F of aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and directed.
S&F GI frame work for seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45 mm suspended from soffit at approx. 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (n.exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre size of grid of GI frame 600 x 600mm to receive E-board ceiling complete all as specified and as directed.
S&F hangers 6mm dia GI (upto 1200mm length) adjoining level fixed in roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete all as specified and as directed.
M&L for providing and fixing gypsum board 12mm thick in ceiling fixed with screw as per manufacturers instructions complete all as specified and as directed.
M & L for preparation of new surfaces of gypsum board and applying two coats of oil bound distemper over a coat of primer on ceiling complete all as specified and directed.
Excavating soft/loose soil in post holes (or similar holes) each n.exc 0.5 Cu.m getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cm in any type of soil complete all as specified and as directed.
M&L for Plain cement concrete (1:2:4) type B-2 using 40mm graded stone aggregate as in foundation filling and mass concrete, bed etc complete all as specified and as directed.
S&F Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, Fe 410 - W (Gde - E-250) quality A etc.
S&F for steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240 including gusset plate, including erection of vertical supports for holding purlins, rafters, base plates, nuts & bolts etc. .
S&F 12mm dia. mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exe 15 cm and n. exc. 22.5 cm long complete all as specified and directed by the Engineer-in-Charge.
M&L mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe-410 W (Gde-E-250) quality A complete all as specified and as directed.
M&L preparation of new or previously untreated steel surfaces of any description, over 10cm in width or girth and applying two coats of synthetic enamel paint over a priming coat of red oxide zinc chrome primer complete all as specified and directed by the Engineer-in-Charge.
S&F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick (i.e. including coating) of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws as specified.
S&F for pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws .
M & L 100mm thick hardcore of broken granite stone or boulders of gauge n.exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and well rammed to a true surface, complete all as specified and directed.
M & L 100 mm thick PCC 1:4:8 type D2 using 20 mm graded stone aggregate as in sub base/ floor, complete all as specified and directed.
M & L 50 mm thick cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in floors finished even smooth without using extra cement complete all as specified and as directed.
M&L 1000 Litres capacity rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) three layered ISI marked hoisted and fixed in position complete all as specified and as directed by the Engineer-in-Charge.
M&L ball valve high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for 20mm dia iron pipe and fixed (minimum weight 210gm) complete all as specified and as directed
S&F in repair bib taps 15mm dia. fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed by the Engineer-in-Charge.
S&F 25mm dia gun metal globe gate valves with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.
S&F 25mm outer dia. 3-layer PP-R polypropylene random copolymer pipes SDR 7.4 & SDR 11 UV stabilised and antimicrobial welded having thermal stability for hot & cold water supply including all PPR plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for point wiring for one light controlled by 1 one way switch with 1.5 Sqmm PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable 1100 Volts grade drawn carefully through existing/New concealed conduit along with 1.5 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire, connected to earth dolly and to be terminated in and including new pressed steel sunken boxes , readily available (Having wall thickness not less than 1.22 mm for boxes upto a size of 200 mmX300 mm and beyond that the wall thickness shall be not less than 1.63 mm) concealed type with 3mm thick bakelite sheet cover for mounting switches, sockets, fan regulators etc including testing on completion complete including making good disturbed surface all as specified and as directed.
All as per Item no 61 here-in-before but for one fan E/Fan and ceiling Fan point controlled by 1 one way switch and regulator all as specified and as directed.
All as per Item no 61 above but for one 3 pin switch socket outlet, 5 Amp on independent board all as specified and as directed.
All as per Item no 61 here-in-before but for one switch socket outlet, 5 Amp on same board with other switches all as specified and as directed
All as per Item no 61 here-in-before but for one16 Amp 3 & 5 pin switch socket outlet, independent with 4 Sqmm single core multi-stranded copper conductor cable (FRLS) along with 4 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire all as specified and as directed.
M & L for XLPE insulated GI wire/strip armoured electric power cable (Heavy duty) ISI mark with stranded aluminium conductor 1100 Volts grade, cross sectional area 25 Sqmm 3.5 Core laid in trenches/poles/ on wall all as specified and as directed.
Supply and fixing socket combination 2 in 1 3 pin 5 and 15 amp flush type universal all as specified and as directed.
Supply and fixing switch piano flush button single pole one way 5 amps all as specified and as directed.
S&F switch flush type, single pole Two way 5 Amps 230 volts all as specified and as directed.
Supply and fixing socket combination 2 in 1 3 pin 5 amp flush type universal all as specified and as directed.
Supply and fixing ceiling rose surface bakelite three terminals all as specified and as directed.
Supply and fixing fan regulator electronic deluxe rotary step type all as specified and as directed.
Supply and fixing sheet metal enclosure for MCB, DBs, phosphatised, Powder coated , Triple Pole and Neutral (TPN), suitable for 4 way, Double door 415 Volts all as specified and as directed .
Supply and fixing sheet metal enclosure for MCB, DBs, phosphatised, Powder coated , single pole and neutral (SPN) 240 Volt , double door, suitable for 8 way with dim rail earth and neutral bar all as specified and as directed.
Supply and fixing MCB Four Pole (FP) C curve 10kA breaking capacity of 63 amps, 415 Volts in proper position all as specified and as directed.
Supply and fixing MCB Single Pole (SP) C curve 10kA breaking capacity of 6 to 32 amps, 240 Volts in proper position all as specified and as directed.
S&F in proper position MCB Double Pole of capacity up to 40 amps, 240 Volts C-series with 10kA breaking capacity all as specified and as directed.
Supply and fixing indoor luminaire decorative batten for wall/ceiling mounting box type Extruded aluminium housing ,PC Diffuser, energy efficient saving LED BATTEN LIGHT 20W,230 V,50 HZ, slim integrated design easy install incl twin twisted copper conductor flexible wire from ceiling rose to connector all as specified and as directed.
Supply and fixing LED mirror light fittings 07 W,230 V,50 HZ suitable for indoor and outdoor applications complete all as specified and as directed.
Supply and fixing LED bulk head fittings 10 W,230 V,50 HZ suitable for indoor and outdoor applications complete all as specified and as directed. Make : Surya cat no SLE BH 10 W or equivalent as approved by GE
Supply and fixing on wall security LED light luminaire fitting 1X25 W and including cable for connection from celling rose with 1.5 Sqmm PVC insulated stranded copper conductor (FRLS) cable including 25 mm GI bracket medium grade 1m long bent to shape including bolt, nut,washer,clamp etc all as specified and as directed by the Engineer-in-charge.
Taking down carefully ceiling fan any sweep and any make after disconnecting the electrical connection, dismantling the blades and removing fan incl blades for safe custody for reuse and re-assembling the fan complete and refixing the fan in same position including all electrical connection all as specified and as directed.
Material and labour for taking out and removing burnt copper winding, cleaning the armature, rewinding the fan armature for 1200mm sweep fan with new super enamelled copper wire of existing gauge including supply and fixing necessary insulating materials etc and varnishing with approved grade of insulation varnish and heating up and testing all as specified and as directed by Engineer-in-Charge.
Supply only bearing No.6201/6202 for ceiling /Exhaust fan
Supply only fan condenser upto 2.5 mfd
Material and labour for painting of ceiling fans complete of any sweep/make with one coat of first quality synthetic enamel paint of approved tint by spray including preparation of old painted surface and removing all dust, oil mark etc and filling cavities with filler materials, and writing serial / MES number as specified (with paint of black colour with each letters/figures in Block of height n.exc2 cm ) complete all as specified and as directed.
S&F Exhaust fan wall mount type 300 mm sweep metal body , single phase with louver shutter and connecting up including provision of hold fasts for fixing fan and louver shutter with cutting of hole and necessary PCC(1:3:6) all as specified and as directed.
S&F Exhaust fan wall mount type 250 mm sweep PVC body , single phase with louver shutter and connecting up including provision of hold fasts for fixing fan and louver shutter with cutting of hole and necessary PCC(1:3:6) all as specified and as directed.
Material and labour for sand cushioning for protection of underground FRLS cable consolidated and compacted with clean dry sand all as specified and as directed (Compacted thickness shall only be measured and paid)
Supply and lay bricks common burnt clay building bricks sub-class B of size 230x113x75 complete all as directed by Engr-in-Charge.
M & L for cutting existing road/PCC Drain/Hard standing for taking out/laying of underground cable and including necessary earth work and making good to match the existing surface with PCC 1:3:6 type C1 using 20 mm grade aggregates complete all as specified.
Material and labour for galvanized iron tubing 50 mm bore light grade with all fitting for protection of FRLS cable, laid in trenches/wall/floor incl necessary clamp, bolt/nut if any all as specified and as directed. Note: Excavation ,earth work shall be measured and paid separately
Material and labour for concealed sub main wiring with two run of 4 sqmm PVC insulated unsheathed FLRS copper conductor single core multi stranded and one run of insulated copper earth wire 4 Sqmm drawn through PVC Conduit complete. Note :- Copper conductor 3 run of 4 sqmm and one run PVC conduit shall be measured as one length.
M & L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron strip 25×4mm earth lead wire by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion
Supply and fixing LED flood lights 100 W for area lighting applications made with single piece pressure die-case aluminium housing with dedicated heat sink and toughened glass. LED surrounded with aluminium reflector for better light distribution and control, IP-65 degree of protection & impact resistance of IK 07 and integrated driver with 5 KV inbuilt surge protection all as specified and directed by Engineer-in-Charge
Supply and fix Voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 15 KVA
M&L for fixing , testing & commissioning digital Power factor meter with accuracy class 1 suitable for LT 415V panel flush pattern square type & wiring including disconnecting and taking down the unserviceable meters complete all as specified and directed
Supply & fixing for APFC , calibrating, testing & commissioning of Microprocessor based Automatic Power Factor Controller of any size with Aux supply 100-440V AC 50 HZ, CT input range 1Amps/5Amps , Voltage input range 100-600 V 50 Hz , Minimum 8 Analogue outputs, with following Salient Features 1. 3 CT Input for Current & Voltage Measurement 2. Provision for Dual PF Settings for Mains & DG Application 3. Manual & Automatic Operation 4.Accuracy of +0.8% for Reactive Power, + 0.5% for Current 6 or 12 steps to operate Capacitor Circuits. 6. 2 & 4 Quadrant Operation for Sites with/without Solar Plants 7. Option of LIFO, FIFO & Intelligent Control Mode to choose the best combination of capacitor bank for compensation with minimum switching to achieve the desired power factor 8. Power Quality Information such as Total & Individual I-THD & V-THD up to 31st Order 9. Current & Voltage Angles displayed for ease of troubleshooting 10. PF Display – 3 Steps after Decimal 11. Capacitor Health Check Monitoring 12. Record of Capacitor Step Switching for scheduling of maintenance of your panel 13. Ambient Temperature Monitoring 14. Time stamping of latest 32 Alarms Controller will be with LCD display Make :- L&T etaSMART or equivalent as approved by GE
Supply & fixing in repair of power factor correction (PFC) capacitors of rating 10 KVAR 440V 50Hz , 3-phase capacitor of any type (cylindrical/rectangular) designed for high-voltage on-load tap-changer (OLTC) applications with Low energy consumption, Capable of withstanding high inrush current, Dry-type, free from oil leakage, Explosion proof feature ,Compact size and light weight.
Supply & fixing in repair of power factor correction (PFC) capacitors of rating 12.5 KVAR 440V 50Hz , 3-phase capacitor of any type (cylindrical/rectangular) designed for high-voltage on-load tap-changer (OLTC) applications with Low energy consumption, Capable of withstanding high inrush current, Dry-type, free from oil leakage, Explosion proof feature ,Compact size and light weight.
Supply & fixing in repair of power factor correction (PFC) capacitors of rating 25 KVAR 440V 50Hz , 3-phase capacitor of any type (cylindrical/rectangular) designed for high-voltage on-load tap-changer (OLTC) applications with Low energy consumption, Capable of withstanding high inrush current, Dry-type, free from oil leakage, Explosion proof feature ,Compact size and light weight.
Supply & fixing in repair of power factor correction (PFC) capacitors of rating 50 KVAR 440V 50Hz , 3-phase capacitor of any type (cylindrical/rectangular) designed for high-voltage on-load tap-changer (OLTC) applications with Low energy consumption, Capable of withstanding high inrush current, Dry-type, free from oil leakage, Explosion proof feature ,Compact size and light weight.
S&F in repair of Control Wiring up to Capacitor bank from outgoing terminals with 1 Core , 2.5 Sq mm copper cable .
S&F in repair of Control Wiring up to Capacitor bank from outgoing terminals with 1 Core , 6 Sq mm copper cable with proper ferules & appropriate Lugs.
S&F in repair of Control Wiring up to Capacitor bank from outgoing terminals with 1 Core , 16 Sq mm copper cable with proper ferules & appropriate Lugs.
S&F in repair of Control Wiring up to Capacitor bank from outgoing terminals with 1 Core , 25 Sq mm copper cable with proper ferules & appropriate Lugs.
S&F in repair of Control Wiring up to Capacitor bank from outgoing terminals with 1 Core , 35 Sq mm copper cable with proper ferules & appropriate Lugs.
Supply and replace Copper lugs suitable for 2.5 Sqmm including nuts, bolts and washers complete all as specified and as directed.
Supply and replace Copper lugs suitable for 6 Sqmm including nuts, bolts and washers complete all as specified and as directed.
Supply and replace Copper lugs suitable for 16 Sqmm including nuts, bolts and washers complete all as specified and as directed.
Supply and replace Copper lugs suitable for 25 Sqmm including nuts, bolts and washers complete all as specified and as directed.
Supply and replace Copper lugs suitable for 35 Sqmm including nuts, bolts and washers complete all as specified and as directed.
Supply and fixing in repair of 3 Pole Power contactor 25A TP 1NO+1NC 220 V AC with Add-on blocks, Conforms to IS/IEC 60947-4-1 & IEC 60947-4-1
Supply and fixing in repair of 3 Pole Power contactor 50A TP 1NO+1NC 220 V AC with Add-on blocks, Conforms to IS/IEC 60947-4-1 & IEC 60947-4-1
Supply and fixing in repair of 3 Pole Power contactor 110A TP 1NO+1NC 220 V AC with Add-on blocks, Conforms to IS/IEC 60947-4-1 & IEC 60947-4-1
Supply and fixing in repair indication lamp, 230 volts AC, LED type colour of Red, Yellow, Blue, Green, White, Amber complete all as directed.
Supply, fixing, testing and commissioning of CT with primary Current 30A - 120A or as per existing panel ratings, class of accuracy class 1 upto 5 VA, including disconnecting old U/S meter, removed from bus bar, fixing new CT to bus bar with suitable clearance, secondary wiring with FRLS insulated copper conductor and lugs with suitable size complete all as directed.
Supply and replace MCCB 3 pole, 415 V, adjustable type 400 Amps with TMD breaking capacity 36 KA including necessary modification in the panel complete all as specified and as directed.
Supply and replace MCCB 3 pole, 415 V, adjustable type 125 Amps with TMD breaking capacity 36 KA including necessary modification in the panel complete all as specified and as directed.
Supply and replace MCCB 3 pole, 415 V, adjustable type 63 Amps with TMD breaking capacity 36 KA including necessary modification in the panel complete all as specified and as directed.
Supply and replace MCCB 3 pole, 415 V, adjustable type 25 Amps with TMD breaking capacity 36 KA including necessary modification in the panel complete all as specified and as directed.
S & F Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20 cm size all as directed
Decarburizing/cleaning complete LT 415 Volts 3 phase panel/ bus bar chamber with electrical connections, complete bus bar from the bus bar chamber, cleaning with CTC and ensure proper decarburizing, refixing the same after applying Becktol Red solution to the bus bar insulator & checking all the connections, tightening the nuts, bolts & thimbles of in-coming/out-going system complete incl replacement of defective rusted bolts & nuts all as specified and directed.
M&L for taking out the loose or separated Door / canopy / front & back sheet covers from existing LT panel and refixing the same after welding, provn of nut bolts / hinges if required as per site, proper locking arrangement and fixing of proper earth connection etc complete all as specified and directed.
M&L for Preparation of external surfaces of LT panels indoor/outdoor type for painting by scraping down old dusted paint by steel brush brooming rubbing and cleaning applying two coats of synthetic enamel paint as approved and marking feeders by Engineer-in-Charge.
M&L for 2mm thick fibre reinforced plastic coating with epoxy paint coat of approved colour on the surface of panel board, RMUs after cleaning the surfaces thoroughly complete all as directed & specified.
SWATHI CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .