Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.7 CrAdmitted-Finance 202 3 PHASE 2 IDA CHERLAPALLY HYDERABAD TELANGANA 500051 | MEDCHAL MALKAJGIRI | TELANGANA | 500051 | L1 | Admitted-Finance | |
| 2 | L2₹8.8 Cr+₹1.1 Cr (13.9%)Admitted-Finance 212 338 OLD DALANWALA DEHRADUN | DEHRADUN | DEHRADUN | UTTARAKHAND | L2 | Admitted-Finance | |
| 3 | L3₹8.9 Cr+₹1.2 Cr (15.9%)Admitted-Finance 10TH FLOOR UNIT NO 1003 KLJ TOWER NETAJI SUBHASH PLACE PITAMPURA NORTH WEST DELHI DELHI 110034 | NORTH WEST DELHI | DELHI | 110034 | L3 | Admitted-Finance | |
| 4 | L4₹9.6 Cr+₹1.9 Cr (24.6%)Admitted-Finance A1 6TH FLOOR SAFAL PROFITAIRE CORPORATE ROAD PRAHLADNAGAR AHMEDABAD 380015 | AHMEDABAD | AHMEDABAD | GUJARAT | 380015 | L4 | Admitted-Finance | |
| 5 | L5₹9.7 Cr+₹2.0 Cr (25.6%)Admitted-Finance 103 PLATINUM PLAZA OPP IOCL PETROL PUMP NR JUDGES BUNGLOW CROSS ROAD BODAKDEV AHMEDABAD GUJARAT 380054 | AHMEDABAD | AHMEDABAD | GUJARAT | 380054 | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | CORE Energy Systems Pvt. ltd. L13 | Modern Electric Company L2 | EVERCREST PROJECTS PVT LTD. L5 | JITENDRA ELECTRICALS L10 | Power and Instrumentation Guj. Ltd. L4 | M/s SterlingElectro Enterprises.P.Ltd L11 | S.T.ELECTRICALS PVT. LTD. L6 | GEETU ENGINEERING AND CONSTRUCTIONS PVT. LTD. L8 | Matsya Green Enviro Pvt Ltd L1 | shiv electric L3 | Ardee Engineering Limited L9 | M/S CMRM INFRAA ENGINEERING PVT LTD L12 | RC POWER PROJECT LIMITED L7 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00Supply, installation, testing and commissioning of 11KV, 1250 A, 26.3 KA/3 sec short circuit rated , 26.3 KA/1 sec Arc Flash rated , Totally Type Tested, LSC2B, HV indoor draw out type metal enclosed switchboard with Copper busbars incorporating Vacuum Circuit breakers, line PT, complete with CTs, PTs, Multi function meters (MFMs), metering and numerical relays and all other accessories like lifting truck, earthing truck, commissioning spares etc complete. The switchgear shall be fabricated as per latest IS and tender specifications 1250A VCB-2 No as Incomer 1250A VCB - 1 No as Buscoupler 1250A VCB- 1 Nos as Tie Feeder 1250A VCB- 9 Nos as Outgoings All feeders shall be provided with numerical relays with IEC 61850 protocol, digital multi function meters to indicate voltage, current, power, energy, power factor; Analog ammeters with selector switch and On/Off/Trip Indication Lamps | ||||||||||||||||
| 1.10 | Supply | 1 | Set | 1,78,04,610.73 ₹1,78,04,610.73 | 94,00,000 ₹94,00,000 | 1,07,79,314 ₹1,07,79,314 | 1,41,23,000 ₹1,41,23,000 | 1,08,58,936.25 ₹1,08,58,936.25 | 88,90,033 ₹88,90,033 Lowest | 1,66,98,000 ₹1,66,98,000 | 1,23,01,500 ₹1,23,01,500 | 1,60,00,000 ₹1,60,00,000 | 99,12,000 ₹99,12,000 | 1,40,10,450 ₹1,40,10,450 | 1,68,74,000 ₹1,68,74,000 | 1,55,76,000 ₹1,55,76,000 |
| 1.20 | Installation | 1 | Set | 9,52,767.4 ₹9,52,767.4 | 1,00,000 ₹1,00,000 | 35,400 ₹35,400 Lowest | 5,60,000 ₹5,60,000 | 61,065 ₹61,065 | 7,55,303 ₹7,55,303 | 2,07,000 ₹2,07,000 | 7,67,000 ₹7,67,000 | 5,25,000 ₹5,25,000 | 1,00,000 ₹1,00,000 | 77,000 ₹77,000 | 5,36,900 ₹5,36,900 | 1,29,800 ₹1,29,800 |
| 2.00Supply, installation, testing and commissioning of 11/0.433KV 2500KVA 3 phase, 50Hz, Dyn11 indoor step down Cast Resin transformer with 8% Impedance, ECBC Energy effeciency rating, Air Natural cooling, Off circuit tap changer with a range of - 7.5% to + 7.5% in steps of 2.5% on HT side and other accessories as listed in the specifications. The transformer shall be suitable for bus duct termination on LV side and shall be provided with cable termination chamber on HV side. The Marshalling box shall be SCADA Compatible with Digital outputs.The CTs required for Restricted earth Falt Protection shall also be provided. The transformer shall be as per technical specification attached and in compliance with IS 2026, IS 10028, latest CPWD and CBIP specifications and latest ECBC code. Note: Trasformer shall be mounted on existing foundation | ||||||||||||||||
| 2.10 | Supply | 3 | Nos | 1,10,80,171.83 ₹3,32,40,515.49 | 82,60,000 ₹2,47,80,000 | 74,15,103 ₹2,22,45,309 | 81,62,000 ₹2,44,86,000 | 81,28,406.4 ₹2,43,85,219.2 | 89,56,124 ₹2,68,68,372 | 85,56,000 ₹2,56,68,000 | 84,07,500 ₹2,52,22,500 | 73,00,000 ₹2,19,00,000 Lowest | 85,00,000 ₹2,55,00,000 | 90,19,350 ₹2,70,58,050 | 1,30,27,200 ₹3,90,81,600 | 84,37,000 ₹2,53,11,000 |
| 2.20 | Installation | 3 | Nos | 97,719.73 ₹2,93,159.19 | 1,07,000 ₹3,21,000 | 35,400 ₹1,06,200 | 88,000 ₹2,64,000 | 54,280 ₹1,62,840 | 1,80,111 ₹5,40,333 | 1,38,000 ₹4,14,000 | 1,18,000 ₹3,54,000 | 1,15,000 ₹3,45,000 | 1,00,000 ₹3,00,000 | 35,000 ₹1,05,000 Lowest | 3,68,750 ₹11,06,250 | 64,900 ₹1,94,700 |
| 3.00Supply, installation, testing and commissioning of 415V, 50Hz, 65KA /1 sec short circuit rated, 65 KA/0.3 sec Arc Flash rated , with copper busbars, indoor switchgear with draw out type ACBs with overload, short circuit and earth fault release protections. The panel shall be totally type tested, arc flash withstand and Form IV B construction. The switchgear shall be fabricated as per latest IS and tender specifications 4000 A microprocessor based EDO 4 pole Incomer Air Circuit Breakers - 3 Nos 4000 A microprocessor based EDO 4 pole Buscoupler Air Circuit Breaker - 2 No 1250 A microprocessor based EDO TPN Outgoing Air Circuit Breakers - 8 Nos 1000 A microprocessor based EDO TPN Outgoing Air Circuit Breakers - 22 Nos All feeders shall be provided with numerical relays with IEC 61850 protocol, digital multi function meters to indicate voltage, current, power, energy, power factor; Analog ammeters with selector switch and On/Off/Trip Indication Lamps Necessary CTs shall be provided on the three phases and neutral to achieve overload, short circuit and ground fault protections. | ||||||||||||||||
| 3.10 | Supply | 1 | Set | 4,43,00,774.49 ₹4,43,00,774.49 | 2,80,00,000 ₹2,80,00,000 | 4,21,38,349 ₹4,21,38,349 | 4,23,23,000 ₹4,23,23,000 | 3,85,97,784.9 ₹3,85,97,784.9 | 4,07,97,034 ₹4,07,97,034 | 3,03,60,000 ₹3,03,60,000 | 3,76,12,500 ₹3,76,12,500 | 2,20,00,000 ₹2,20,00,000 Lowest | 3,25,00,000 ₹3,25,00,000 | 3,29,49,275 ₹3,29,49,275 | 3,97,12,900 ₹3,97,12,900 | 3,24,50,000 ₹3,24,50,000 |
| 3.20 | Installation | 1 | Set | 10,26,057.2 ₹10,26,057.2 | 2,18,000 ₹2,18,000 | 1,12,100 ₹1,12,100 | 2,35,000 ₹2,35,000 | 67,850 ₹67,850 | 3,90,434 ₹3,90,434 | 1,38,000 ₹1,38,000 | 17,70,000 ₹17,70,000 | 12,00,000 ₹12,00,000 | 3,00,000 ₹3,00,000 | 52,500 ₹52,500 Lowest | 2,24,790 ₹2,24,790 | 1,29,800 ₹1,29,800 |
| 4.00Supply and installation of 415V, 4000 A, 65kA/1sec, 3 phase and neutral sandwich type copper busduct with all required accessories for indoor installation as per Specifications | ||||||||||||||||
Tender Value
₹8.5 Cr
EMD Value
₹17 L
Closing Date
11 Jul 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Chief Engineer and DCE CED PD EP
Chief Engineer and DCE CED PD EP, 2nd Floor Sarathi Building, NFC Hyderabad, 500062
SITC of 11KV Substation works for Tube Plants Load Centre at NFC, Hyderabad
2026_NFC_910983_1
NFC/EP/11/2026
Open Tender
Electrical Works
Works
300 days
NFC Hyderabad
Please refer Tender documents.
9 documents required · 9 mandatory
₹0
₹17 L
3 Oct 2026
1 Jun 2026
15 Jul 2026
1 Jun 2026
11 Jul 2026
12 Jun 2026
1 Jun 2026 - 10 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply, installation, testing and commissioning of 11KV, 1250 A, 26.3 KA/3 sec short circuit rated , 26.3 KA/1 sec Arc Flash rated , Totally Type Tested, LSC2B, HV indoor draw out type metal enclosed switchboard with Copper busbars incorporating Vacuum Circuit breakers, line PT, complete with CTs, PTs, Multi function meters (MFMs), metering and numerical relays and all other accessories like lifting truck, earthing truck, commissioning spares etc complete. The switchgear shall be fabricated as per latest IS and tender specifications 1250A VCB-2 No as Incomer 1250A VCB - 1 No as Buscoupler 1250A VCB- 1 Nos as Tie Feeder 1250A VCB- 9 Nos as Outgoings All feeders shall be provided with numerical relays with IEC 61850 protocol, digital multi function meters to indicate voltage, current, power, energy, power factor; Analog ammeters with selector switch and On/Off/Trip Indication Lamps | |||||
| 1.1 | Supply | 1 | Set | - | - |
| 1.2 | Installation | 1 | Set | - | - |
| 2Supply, installation, testing and commissioning of 11/0.433KV 2500KVA 3 phase, 50Hz, Dyn11 indoor step down Cast Resin transformer with 8% Impedance, ECBC Energy effeciency rating, Air Natural cooling, Off circuit tap changer with a range of - 7.5% to + 7.5% in steps of 2.5% on HT side and other accessories as listed in the specifications. The transformer shall be suitable for bus duct termination on LV side and shall be provided with cable termination chamber on HV side. The Marshalling box shall be SCADA Compatible with Digital outputs.The CTs required for Restricted earth Falt Protection shall also be provided. The transformer shall be as per technical specification attached and in compliance with IS 2026, IS 10028, latest CPWD and CBIP specifications and latest ECBC code. Note: Trasformer shall be mounted on existing foundation | |||||
| 2.1 | Supply | 3 | Nos | - | - |
| 2.2 | Installation | 3 | Nos | - | - |
| 3Supply, installation, testing and commissioning of 415V, 50Hz, 65KA /1 sec short circuit rated, 65 KA/0.3 sec Arc Flash rated , with copper busbars, indoor switchgear with draw out type ACBs with overload, short circuit and earth fault release protections. The panel shall be totally type tested, arc flash withstand and Form IV B construction. The switchgear shall be fabricated as per latest IS and tender specifications 4000 A microprocessor based EDO 4 pole Incomer Air Circuit Breakers - 3 Nos 4000 A microprocessor based EDO 4 pole Buscoupler Air Circuit Breaker - 2 No 1250 A microprocessor based EDO TPN Outgoing Air Circuit Breakers - 8 Nos 1000 A microprocessor based EDO TPN Outgoing Air Circuit Breakers - 22 Nos All feeders shall be provided with numerical relays with IEC 61850 protocol, digital multi function meters to indicate voltage, current, power, energy, power factor; Analog ammeters with selector switch and On/Off/Trip Indication Lamps Necessary CTs shall be provided on the three phases and neutral to achieve overload, short circuit and ground fault protections. | |||||
| 3.1 | Supply | 1 | Set | - | - |
| 3.2 | Installation | 1 | Set | - | - |
| 4Supply and installation of 415V, 4000 A, 65kA/1sec, 3 phase and neutral sandwich type copper busduct with all required accessories for indoor installation as per Specifications | |||||
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.17 MB
Tendernotice_2.pdf
PDF • 0.04 MB
Tendernotice_3.pdf
PDF • 0.28 MB
Tendernotice_4.pdf
PDF • 3.31 MB
Tendernotice_5.pdf
PDF • 0.58 MB
Tendernotice_6.pdf
PDF • 1.30 MB
Technicalbid.xls
Tender Documents • 0.09 MB
BOQ_957431.xls
BOQ • 0.27 MB
Corrigendum__datechange2.pdf
PDF • 0.55 MB
Corrigendum__clarifications3.pdf
PDF • 0.55 MB
Corrigendum2_Clarifications.pdf
PDF • 0.47 MB
Corrigendum_Datechange.pdf
PDF • 0.47 MB
Corrigendum_Queries.pdf
PDF • 1.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .