| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.0 LAccepted-AOC RAILWAY ROAD 9 10 KC MARKET 132001 2021R66 | KARNAL | HARYANA | 132001 | L1 | Accepted-AOC LOA issued | |
| 2 | L2₹49.5 L+₹51,140 (1.04%)Rejected-Finance MEHEM ROAD NEAR TVS BIKE AGENCY GOHANA SONIPAT HARYANA 131301 ON MEHAM ROAD NEAR TVS BIKE AGENCY GOHANA 131301 | SONIPAT | HARYANA | 131301 | L2 | Rejected-Finance L2 | |
| 3 | L3₹51.1 L+₹2.1 L (4.29%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | Rejected-Technical 11 E 379 11 PUL PEHLL 110044 | SOUTH EAST DELHI | DELHI | 110044 | - | Rejected-Technical Not eligible | |
| 5 | Rejected-Technical | - | Rejected-Technical Not Eligible |
Tender Value
₹51.4 L
EMD Value
₹1.0 L
Closing Date
10 Apr 2025, 5:00 pmClosed
VISHWNATH KHICHI
ED - Karnal
Pdg. 250 KVA D.G. Set, 250 KA Transformer and Allied material for 900 LPM PSA plant based medical grade Oxygen Generated units in Civil Hospital Distt. Sonipat
2025_HRY_437781_1
2025A4B4B5BF B557 4951 955E 8289625822B5665BAR
Open Tender
Electrical Works
Works
180 days
Sonepat
2 documents required · 2 mandatory
₹5,000
₹1.0 L
Yes
17 Jun 2025
1 Apr 2025
11 Apr 2025
1 Apr 2025
10 Apr 2025
1 Apr 2025
Amount
[13.20]Providing and Fixing Poly Carbonate Sheet 1.25mm thickness on Gates and grills excluding the cost of MS framework but including the cost of nut bolts, Welding rods complete in all respect as per direction of Engineerin-Charge. [Through Rate]
[23.22.1.12]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.12. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 300 to 400 amp , 50 KA [Through Rate]
[23.22.1.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.3. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 16 to 100 Amp, 25 KA [Through Rate]
[23.22.1.5]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.5. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 200 to 250 Amp, 25 KA [Through Rate]
[23.22.1.6]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.6. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 300 Amp, 25 KA [Through Rate]
[23.22.8.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 8.3. SITC Four pole ON LOAD Manual change over switch in SS enclosure of following Ratings 200 amp 415 volts [Through Rate]
[23.24.1]MS STAND, BUS BAR CHAMBER AND PANELS 1. Supply and erection of M.S. angle iron frame duly welded for housing M.S. sheet & main switches etc. on it, fixed on wall by means of suitable size of rag bolts with cement concrete, duly painted with three coats of approved paint including one coat of red oxide. [Through Rate]
[23.26.1]SAFETY ITEMS 1. Supply and erection of Medium Voltage caution notice plate of size 200*150 mm in three languages. [Through Rate]
[23.26.2]SAFETY ITEMS 2. Supply and erection of High Tension Voltage caution notice plate of size 250*200 mm in three languages. [Through Rate]
[23.26.3]SAFETY ITEMS 3. Supply and erection of shock restoration chart in glass frame. [Through Rate]
[23.26.4]SAFETY ITEMS 4. Supply & Erection of mild steel bucket stand suitable for 6 Nos. fire buckets,(but without bucket) including the cost of welding and painting of complete stand will one coat of red oxide and 2 coats of approved paint of red colour with all labour and material required to complete the job in all respect up to the entire Satisfaction engineer in charge of the work (size 6x4 made of GI pipe 32mm dia). [Through Rate]
[24.1.10]EARTHING AND LIGHTENING ARRESTOR 10. Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material. [Through Rate]
[24.1.3]EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. [Through Rate]
[24.1.4]EARTHING AND LIGHTENING ARRESTOR 4. Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required. [Through Rate]
[24.1.5]EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode. [Through Rate]
[24.1.7]EARTHING AND LIGHTENING ARRESTOR 7. Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required. [Through Rate]
[24.1.8]EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. [Through Rate]
[24.1.9]EARTHING AND LIGHTENING ARRESTOR 9. Providing and fixing 25 mm x5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required. [Through Rate]
[24.13.100]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 100. 400 Sq mm 3.5 core (Arm.) [Through Rate]
[24.13.68]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 68. 120 Sq mm 3 core (Arm.) [Through Rate]
[24.16.4]HT CABLES (Aluminium Conductor, Armoured and Unarmoured) Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 4. Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 95 Sq mm 3 core [Through Rate]
[24.2.7.5]LT CABLE 7.5. Supply and erection of suitable compression type brass cable glands for underground Cable :- 120 sqmm to 185 sqmm Cable 3 to 32 Core [Through Rate]
[24.2.7.7]LT CABLE 7.7. Supply and erection of suitable compression type brass cable glands for underground Cable :- 300 sqmm to 400 sqmm Cable 3 to 3½ Core [Through Rate]
[24.2.8.10]LT CABLE 8.10. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 120 sqmm [Through Rate]
[24.2.8.12]LT CABLE 8.12. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 185 sqmm [Through Rate]
[24.2.8.15]LT CABLE 8.15. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 400 sqmm [Through Rate]
[24.2.8.8]LT CABLE 8.8. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 70 sqmm [Through Rate]
[24.3.3.3]HT CABLE 3.3. Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 240 to 400 sqmm [Through Rate]
[24.5.2.4]MISCELLANEOUS ITEMS 2.4. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 90/75 mm outer dia/inner dia [Through Rate]
[24.5.2.5]MISCELLANEOUS ITEMS 2.5. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 120/105 mm outer dia/ inner dia [Through Rate]
[24.7.5]RCC FOUNDATIONS FOR DG SET 5. 250 KVA DG Set [Through Rate]
[24.7]RCC FOUNDATIONS FOR DG SET "Providing RCC foundation of M20 grade (1 Cement:1.5 Stone aggregate: 3 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @ 50 kg/cum of concrete contents, concrete cover 50mm, over a bed of 75mm thick PCC 1:5:10, of required dimensions as per OEM recommendations to provide levelled surface for placement of the DG set complete in all respects and as per directions of Engineer-in-charge (Size of foundation assumed = 5.0x1.8x1.0m)" Unit: per cum [Through Rate]
Pdg. And Fixing of wire mesh jali around the transfarmer of size 4` x 8` made out of 75 x 25 x 3.25 mm jali fixed with angel iron frame made out of M.S. Angel 50 x 50 x 6 mm.
Supply , fixing , connecting and testing of APFC Panel 75 KVAR @ 440V. The stage ratings shall be 2 X 10 KVAR plus 1X 25 kVAr plus 3 X 10 KVAR. The APFC Panel shall be (Indoor) type, weather, dust and vermin proof suitable for humidity up to 95%. Average daily temperature: plus 35°C max, Ambient temperature: -5°C to 40°C, Maximum altitude: 2000 m. As equipment shall be comprising of the following:- (A) Insulated bus bar assembly made from Aluminium and rated of 200 Amps capacity. The short circuit withstand capacity shall be 50 KA / 1 Sec ( Icw) for the main bus bar and the rated impulse withstand voltage shall be 6 KV. ( B) The incomer of the APFC Panel shall be a 160 Amp, MCCB, 3P, 50kA TMD type with O/L and S/C protection, Ics = 100% Icu, MCCB shall have standard extended rotary handle, spreaders, phase barrier. . Make:- Schneider Electric / ABB / Legrand. (C) Capacitor Units : The capacitor unit shall be metalized polypropylene film with Zn / Al alloy. The capacitors shall be encapsulated in an aluminium can. The capacitor unit shall have a rated voltage of 440V and shall have a maximum over current capacity of : 1.8 In. The capacitor unit shall have a built in 3 phase over pressure protection and shall have discharge resistors ( 50V in 1min ) factory fitted and shall be tamper proof. Capacitance Tolerance -5%, plus 10%. Maximum permissible over voltage 1.1 x Un, 8 h every 24 h. Make – Schneider Electric / ABB / Legrand. `(D) Short-circuit and Overload Protection : Each stage of the APFC Panel shall have a suitably rated MCCB for short-circuit and overload protection. The over-current setting shall be adjustable and Breaking capacity Ics=) 36kA . The MCCB shall be of certified design confirming to IS Make:- Schneider Electric / ABB / Legrand. ` (E) PF Regulator : Advanced Range PF Regulator shall have 8 steps with a LCD Display, Voltage Range : 90V - 550V, 50 / 60Hz, CT Input : 1A/5A with a built in RS 485 communication port. The PF Regulator shall be of certified design confirming to IS. Make : Schneider Electric / ABB / Legrand. (F) Stage Contactor and reactor : The electromagnetic contactors shall be rated for 660 Volts and shall be 3-pole type and shall be employed for switching `on` and switching `off` operations in capacitor banks. The rated voltage of control coil shall be 415V (phase-to-phase). This voltage is subject to a variation of ( plus ) 10% and (-) 15%. The contactor shall be AC3b type. The contactor shall be of certified design confirming to IS. Make – Schneider Electric / ABB / Legrand. `(G) Ventilating fans of required size shall be sued to dissipate the heat produced by the capacitor bank components like the capacitor units, reactors, contactors, breakers etc. The capacitor banks should be of type tested design and temperature rise test report of the capacitor bank performed at an independent laboratory should be submitted along with the offer.
Supply and Erection of rubber mat of size 1M x 2 M X 12 mm thick suitable for 11 KV ISI marked complete in all respect up-to the entire satisfaction of the engineer In-charge of the work.
Supply and Erection of fire bucket of 9 ltr. capacity made out of 24guage G.l. sheet and duly painted with one coat of red oxide and 2 coats of approved paint in red colour and written with the fire` as per fire protection necessary sand filling in the bucket hung the bucket on stand with all labour and material required to complete the job all respect up to entire satisfaction of the Engineer m charge of the work
S/E/T/C of CO2 type fire Extinguisher 4.5 KG capacity made from brand new seamless cylinder as per ISI mark IS: 7285 and CCE approval fitted with discharge hose and horne and squeeze grip /wheel type valve with initial charge as per IS 15683 : 2006 specification bearing ISI marks and EIL approved complete in all respect (Safex/ Minimax Make)
`Supply, Erection, testing and commissioning of Transformer-250 KVA 11/0.433 K. V.3 Phase-50 cycles copper wound outdoor type as per latest IS specification efficency level 2 confirming to IS 1180 and IS 2026 with laid on existing foundation at site of work, along with petty works required up to the entire satisfaction of the Engineer-in-charge of work as per detailed specification given as under: No. load voltage ratio 11/0.433 K V. No. of Phase = 3 Frequency cycles = 50HZ Type- double wound core type copper wound Cooling = ONAN Duty = Outdoor Vector group/ISS-DYN 11 Off Load tap Changer. Temperature rise (oil/Res = 0C) 40/45 C Attitude= upto 1000metres above M.S.L. Fitting/Accessories Provided. Bucholez relay with alarm and trip contact. Oil Surge Relay. Oil conservator with Filling hole and cap. Plain oil level guage with minimum Level marking.` `Thermometer pocket 4Nos. plain roller uni directional OTI H.V Impulse with stand voltage (KV peak) 75 kvp. Silica-Gel Breather 1st Filling of oil. Drain cum filter value Rating and diagram plate Two earthing terminal Lifting arrangement Presure release walve / Air releases Plug, Explosion vent Diagram and rating plate Termination: - HV=3 pole single glands Cable box suitable for reception of 1 no. 3 core up to 120 sqmm H.T.XLPE cable including cost of copper lugs/thimble. LT: 4 Pole cable box suitable for 2x300 mmsq 3.5 core Aluminum cable having extended copper bars of requisite capacity from L. T. bushing for making connection. LV: Neutral suitable cable box for earthing Provided. Make as per approved make list attached
SITC of Three Phase 250 KVA (CPCB-IV plus ), Diesel Generating Set comprising of: ENGINE SPECIFICATION: 1500 RPM under NTP conditions, water cooled, Four stroke, Electric start, having the following technical specifications: - AIR INTAKE SYSTEM Air intake manifold. Dry type air cleaner. EXHAUST SYSTEM Exhaust manifold and turbocharger provided with shield to isolate heat Residential silencer. COOLANT SYSTEM Radiator Coolant additive concentrate. Bypass thermostat. LUBRICATING SYSTEM Mul level type oil filter with electric pump Full flow lube oil filter. Lube oil by-pass filter. ALTERNATOR SPECIFICATION: alternators (@40 Deg. C), suitable for continuous opera on at 1500 RPM genera ng 415 V at 0.8 P.F. (Lag) 50 Hz, 3 phase. The alternator shall be Brushless type, self-excited and self-regulated an AVR. The alternator will be suitable for tropical climate and shall generally conform to IS:13364 and IS/IEC 60034-1 The salient features of the alternator are: - · · · · ± 0.5% voltage regular on in static conditions. IP: 23 protections with class ‘H/ F’ insula on and temperature limited to class `H /F’` insula on limited. Permanent lubricated sealed bearing. Permissible overload of 10% for 1 hour in 12 hours of opera on. CANOPY SPECIFICATION: (Optional from 1010 KVA Onwards) · The enclosure is fabricated out of CRCA sheet. · The sheet metal components are hot dipped in TANKS pre-treated before powder cognation. · Enclosure is powder coated (inside as well outside) with a special pure polyester based powder. · The doors are gasketed with high quality EPDM gaskets to avoid leakage of sound. · The door handles are lockable type. · Sound proofing of enclosure is done with high quality rock wool/mineral wool/acoustic foam · The rock wool is further covered with fiber glass cloth and perforated powder coated MS sheet. BASE FRAME: Engine and alternator are mounted, coupled and aligned on a common channel iron fabricated Base Frame. FUEL TANK: Fuel tank is fabricated from sheet metal complete with drain valve, air vent and inlet and outlet connection. The fuel tank shall be floor mounting type placed Inside the acoustic enclosure. including Isolater Panel and AMF Panel including the cost of 250 Ltr. Diesel and 02 No. 50 Ltr. Tank Makes as per approved List.
PS ELECTRIC (BID ID -1239118)
advance electrical (BID ID -1239371)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .