Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹55.0 LAccepted-AOC 37 1634 IMPERIAL HOUSE KALOOR KATHRIKADAVU KATHRIKADAVU ERNAKULAM KERALA 682017 | ERNAKULAM | KERALA | 682017 | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹61.8 L+₹6.8 L (12.4%)Rejected-Finance CHEMBISSERY PUTHIYAKAVU TRIPUNITHURA P O KOCHI 682301 | ERNAKULAM | KERALA | 682301 | L2 | Rejected-Finance Quoted rates are higher than L1 | |
| 3 | L3₹66.9 L+₹11.9 L (21.6%)Rejected-Finance | L3 | Rejected-Finance Quoted rates are higher than L1 | |
| 4 | L4₹67.8 L+₹12.7 L (23.1%)Rejected-Finance 66 102 ARUN JYOTHI MULLASSERY CANAL ROAD ERNAKULAM KOCHI 682 011 | KOCHI | ERNAKULAM | KERALA | 682011 | L4 | Rejected-Finance Quoted rates are higher than L1 | |
| 5 | L5₹74.3 L+₹19.2 L (35.0%)Rejected-Finance 2ND FLOOR PAPPOOTTY COMPLEX VAZHAKULAM MUVATTUPUZHA KERALA 686670 | MUVATTUPUZHA | ERNAKULAM | KERALA | 686670 | L5 | Rejected-Finance Quoted rates are higher than L1 |
Tender Value
Refer Docs
EMD Value
₹1.7 L
Closing Date
30 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Commander Works Engineer NB Kochi
INS Dronacharya Fort Kochi Kochi 682 001
81015Addn Altn to HT Distribution System and Provn of HT Ring Main Circuit at INS Dronacharya
2020_MES_384721_1
81015/HT Ring Main Circuit/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
FortKochi
Class C and above
b ii
7 documents required · 7 mandatory
₹1,000
GE Fort Kochi
₹1.7 L
Yes
29 Jan 2021
8 Oct 2020
7 Dec 2020
8 Oct 2020
30 Nov 2020
16 Nov 2020
9 Oct 2020 - 22 Oct 2020
60 days
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m in depth and getting out in soft / loose soil.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in soft / loose soil.
Removing excavated material not exceeding 50 Mtr and depositing where directed at a level not exceeding 1.5 Mtr above the starting point.
Supply, laying and testing HT cable(Earthed) XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts grade, conforming to IS 7098 - Part II - 1985 of cross sectional area 185 Sq mm, 3 core complete all as specified and directed. Note : Cable joint, Jointing material, cable protection , cable cushioning and necessary earthwork excavation shall be measured and paid separately under respective items.
Providing sand cushioning with locally available dry sand including filling, spreading, levelling in layers in cable trench for protection of under ground cable. Note : Punned thickness shall be measured for payment.
Supply and laying un-reinforced precast concrete cable cover, class HV, type 1, size 300mm x 180mm x 40mm complete all as specified.
Supply and fix pre cast RCC cable route indicator of size 70 cm height x 30 cm wide x 05 cm thick tapered on top and embedded in ground up to 50cm depth at intervals not exceeding 30 Mtrs or as per the field requirement. The exposed portion shall be painted with non-washable paint of yellow colour and embosed with letters "HT CABLE 11 KV" and directions of cable and the same shall be paint with black paint complete all as directed.
Supply and fix cable jointing kit for 11 KV (Earthed) grade cable for indoor termination, heat shrink type joint complete with jointing materials and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 Sqmm complete all as specified.
Supply and fix cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing materials and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 Sqmm complete all as specified.
Supply and laying 80 mm bore galvanised steel tubes with all fittings, light grade laid in trenches for cable protection.
Supply, installation, testing and commissioning of SF6 Ring Main Unit 11 KV, 630 Amp, 21 kA for 3 sec, outdoor type, motor operated, both side extensible, non drawout type, three way module consisting of two Nos Load Break Switch with and including castle key lock for Load Break Switches including one Vacuum Circuit Breaker for outgoing. All live parts enclosed in a robotically welded minimum 2.5mm thick stainless steel tank with internal arc classification compiled to IEC 62271 - 200. Three numbers resin cast ring core current transformers of suitable ratio for protection of VCB including microprocessor based overcurrent and earth fault relay with highset on breaker side. Normal voltage 11 KV. Rated frequency 50 Hz. Copper busbars of 630 Amp rating. Temperature class -25 to +40 degree celsious outdoor. Degree of protection IP 67. Metal enclosed switchgear IEC 60298, General purpose switches IEC 60265-1, Disconnectors and earthing switches IEC 60129, Switch fuse combination IEC 60420, Circuit beakers IEC 60056, Common specifications IEC 60694. LBS & VCB module consisting of cable switch 12KV, 630 Amp. Bushings for connection of external busbar. Manometer and signal from pressure indicator wired to teminals. Snap action mechanism for motor operation. Control Voltage 24 V DC for motor operation. Arc proof cable cover standard with interlocking. Short circuit and earth fault indicator. Capacitive voltage indication fixed type VPIS 9-15 KV. Aux switch for load break switch and vacuum circuit breaker position 2 NO + 2 NC. Cable support bars with battery and battery charger complete with foundation as per OEM design and instruction. Note :- The cost of foundation and disconnection of existing HT cable from existing transformer/ HT switch gear & connection in RMU for installation of RMU shall be deemed to be included in the quoted rate.
Supply, installation, testing and commissioning of 630 Amp, 21 kA for 3 sec, outdoor type, motor operated, both side extensible, non drawout type, two way module consisting of two Nos Load Break Switch (one incomer and one outgoing) SF6 Ring Main Unit. All live parts enclosed in a robotically welded minimum 2.5mm thick stainless steel tank with internal arc classification compiled to IEC 62271 - 200. Normal voltage 11 KV. Rated frequency 50 Hz. Copper busbars of 630 Amp rating. Temperature class -25 to +40 degree celsious outdoor. Degree of protection IP 67. Metal enclosed switchgear IEC 60298, General purpose switches IEC 60265-1, Disconnectors and earthing switches IEC 60129, Switch fuse combination IEC 60420, Circuit beakers IEC 60056, Common specifications IEC 60694. LBS module consisting of cable switch 12KV, 630 Amp. Bushings for connection of external busbar. Manometer and signal from pressure indicator wired to teminals. Snap action mechanism for motor operation. Control Voltage 24 V DC for motor operation. Arc proof cable cover standard with interlocking. Short circuit and earth fault indicator. Capacitive voltage indication fixed type VPIS 9-15 KV. Aux switch for load break switch position 2 NO + 2 NC. Cable support bars with battery and battery charger complete with foundation as per OEM design and instruction. Note :- The cost of foundation and disconnection of existing HT cable from existing transformer/ HT switch gear & connection in RMU for installation of RMU shall be deemed to be included in the quoted rate.
Material and labour for galvanised iron strip 32 x 6 mm for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in pipe or any other indicated situation for loop earthing etc. as required complete all as specified and directed.
Material and labour for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level, steel earth plate connected with GI strip 32 x 6 mm by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel, GI protection pipe 40 mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connected to earthing test point all as specified or indicated including excavation, earth work, salt and charcoal dust mixed and packed 150 mm thick around GI earth plate, GI pipe medium grade 20 mm nominal bore watering pipe, GI sheet funnel, wire mesh, PCC pit, RCC cover 50 mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 8 mm dia at the rate of 75 mm centre to centre both way with 12 mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1 including testing on completion complete all as specified and directed. Note: Thye length of main earth lead up to 7.5m from earth electrode to test point is deemed to be included in the above quoted rate. Earth lead beyond this only shall be measured & paid seperately under item No. 13 of BOQ
Material and labour for disconnecting the power supply cable from the existing HT panel board at main power house, removing VCB panels from the panel board and re-arranging/Re-locating 1 No VCB panel in the same sub station as directed including connecting the removed cables and other accessories to the panel board asper the sketch enclosed and testing on completion, complete all as directed.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .