| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.9 LAccepted-AOC H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L1 | Accepted-AOC Deducts after sch of credit | |
| 2 | L2₹9.9 L+₹92,278 (10.3%)Rejected-Finance 0 NEAR SHIV MANDIR KALYANIPURA KRIPAL NAGAR AJMER RAJASTHAN 305001 UDYAM RJ 01 0091182 | AJMER | RAJASTHAN | 305001 | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹10.0 L+₹1.0 L (11.4%)Rejected-Finance 2 A 31 CHOPASANI HOUSING BOARD JODHPUR RAJASTHAN 342008 | JODHPUR | RAJASTHAN | 342008 | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹12.2 L+₹3.2 L (36.1%)Rejected-Finance PAHARGANJ SECOND COLONY LAL SAGAR JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L4 | Rejected-Finance Not Being L1 | |
| 5 | Rejected-Technical | - | Rejected-Technical Due to EPF Number not uploaded |
Tender Value
Refer Docs
EMD Value
₹19,960
Closing Date
6 Mar 2021, 6:00 pmClosed
AGE I Nagtalao
Military Engineer Services AGE I Nagtalao Pin 342037 CO 56 APO
Repair Replacement to runway and taxi way lights cable CCR unit and other connected works at Ralawas Under AGE I Nagtalao
2021_MES_421959_1
8326/20-21/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE I Nagtalao
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
AGE I Nagtalao
₹19,960
Yes
17 May 2021
13 Feb 2021
8 Mar 2021
13 Feb 2021
6 Mar 2021
20 Feb 2021
Amount
Supply, Installation, Testing & Commissioning of FAA complaint indoor type microprocessor based, air cooled constant current regulator of Thyristor control electronic type suitable for use on 240/415 VAC; 50/60 Hz, input AC supply with below mentioned output power at 6.6 amps with 5 steps variation of current output suitable for local and remote control operation with 24/48 VDC control supply complete with output current indicated on multifunction digital display, over current, over voltage, earth fault protection and earth leakage meter, positive back indication equipments relay contactor etc. as required as per specification of following rating :a)7.5 KW MPCCR at 6.6 Amp, supply voltage 240 VAC tapping at 4 KW. Complete all as specified and directed by Engineer-in-charge Make:- Nasu System / ABD / Safeguard.
Maintenance and upgrading of Licensed Airfield Lighting Control and Monitoring System software to existing ALCMS system. Complete all as specified and directed by Engineer-in-charge Make: Make: Rockwell Automation / Siemens /Indosoft / GE Fanuk
Supply & Fixing of Aerodrome beacon Light Lamp , suitable for AB-500P64 220V ROTATING BEACON 220V. Complete all as specified and directed by Engineer-in-charge, Model :- M60-19 Lamp 500W Make:- Manairco, Hughey & Phillips
Supply, Installation, testing and commissioning of high intensity 200 watt bi-pin lamp in repair for runway lights complete all as specified and directed by Engineer-in-charge.Make:- AMA or equivalent to Bildal/ESA/Thorn
Supply, Installation, testing and commissioning of high intensity 200 watt bi-pin lamp holder in repair for runway lights complete all as specified and directed by Engineer-in-charge.Make:- AMA or equivalent to Bildal/ESA/Thorn
Supply, Installation, Testing & Commissioning of Medium Intensity 45 watt bi-pin lamp for runway taxiway lights. complete all as specified and directed by Engineer-in-charge. Make:- AMA/Bildal/ESA/Thorn
M & L for 5 KV grade plug and receptable of type - I class -B connector and suitable for field attachment with 5 KV grade PVC insulated PVC sheathed single core copper conductor cable as required and confirming to the specification as required. Make: AMA/Thorn/Bildal/ESA
M&L for medium intensity 15watt ,6/6.6 Amps,5KV,50Hz,0.95PF individual lamp series to series type isolating transformer encapsulated in polyester resin , finally moulded with neoprene type rubber compliant to FAA specification no. 150/5345-47C specification complete all as specified and directed by Engineer-in-charge.
Supply and Laying of 6 mm square 5 KV grade single core, stranded copper conductor PVC insulated & PVC sheathed, underground airport lighting cable generally.confirming to IS: 1554 Part-II 1981 with upto date amendment as required. complete all as specified and as directed by Engineer in charge.
Excavating in trenches n.exc 1.5 m width and n.exc 1.5m in depth for taking out cable and cable cover and getting out in any type of soil. complete all as specified and as directed by Engineer in charge.
Returning, filling in, including spreading levelling, watering and well ramming in layers n.exc 25 Cm. complete all as specified and as directed by Engineer in charge.
Removing excavated materials n.exc 50 mtr depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and as directed by Engineer in charge.
M&L for sand cushioning to PVC/ XLPE cables with tibba sand and punning to provide required cover to UG cables. complete all as specified and as directed by Engineer in charge.Note :- For the purpose of payment only punned thickness will be measured
Laying only old retrieved stone patty/brick/PCC cover on the cable abutting each other for the cable protection gap between two adjacent patties n.exc 10mm complete all as specified and as directed by Engineer in charge.
Material and labour for laying 40 to 50 mm thick quarry faced stone slab 25 to 30 cm wide and not exceeding 60 cm long laid dry abutting each other with gap between adjacent patties n.exc 10 mm for cable protection complete all as specified and as directed by Engineer in charge.
Supply and fix GI Tubing 40 mm bore light grade (ISI Marked) with all fittings (ISI marked) and fixed complete to wall and ceiling or laid in floor complete all as specified and as directed by Engineer in charge.
M & L in finding and rectifying the fault in Runway/Taxiway lights by duly locating fault and rectifing by checking the circuit in series / light to light, Excavation and Returning filling if required at site. complete all as specified and as directed by Engineer in charge. Note:- Lamps, Lamp Holder, connectors, transformers, cables etc required in rectifying the fault will be measured and paid seperately under relevent items
M/S JAGDAMBA ENTERPRISES
Axxon Tech Industries
Shree Karni Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .