Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.1 LAccepted-AOC 11TH FLOOR ECO CENTRE BUSINESS TOWER P NO 4 EM BLOCK SECTOR V KOLKATA 91 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | L1 | Accepted-AOC L1 |
Tender Value
Refer Docs
Closing Date
19 Oct 2024, 3:00 pmClosed
DGM-C
Gujarat Refinery, Vadodara
JC24ELS257-Comprehensive Maintenance of Ms Bluestar make Air conditioning system at IOCL Dumad complex.
2024_JR_180296_1
JC24ELS257
Single
Electrical Works
Works
365 days
Gujarat Refinery
As per NIT
5 documents required · 5 mandatory
Exempted
16 May 2025
25 Sept 2024
21 Oct 2024
25 Sept 2024
19 Oct 2024
25 Sept 2024
Amount
RFQ ITEM NO.00010 Comprehensive Maint of Bluestar AC Comprehensive Maintenance of M/s Bluestar make VRF type AC plants installed at different locations of IOCL Dumad Complex inlcuding supply of manpower, materials i.e. spares(subject to standard exclusions) & consumables, tools & tackles, etc. required for successful execution of the job complete in all aspects.
SOR ITEM '00020: Comprehensive Maintenance of (3 X 24HP) VRF TYPE AC installed for Admin building ground floor & first floor, with following configuration: Outdoor units: Capacity - 24 HP, Qty - 3 Nos. Indoor Units: a) Ductable split AC: Capacity - 2.5 TR, Qty - 3 Nos Capacity - 4.0 TR, Qty - 4 Nos Capacity - 5.0 TR, Qty - 2 Nos b) 4-way cassette AC: Capacity - 2.8 TR, Qty - 2 Nos Capacity - 2.0 TR, Qty - 2 Nos
SOR ITEM '00030: Comprehensive Maintenance of (4 X 18HP) VRF TYPE AC installed for Admin building ground floor, with following configuration: Outdoor units: Capacity - 18 HP, Qty - 4 Nos. Air Handling Unit (AHU): Capacity - 10500 CFM, Qty - 2 Nos. Chemical Media filter : Qty - 1 Nos.
SOR ITEM '00040: Comprehensive Maintenance of (4 X 24HP) VRF TYPE AC installed for Admin building first floor, with following configuration: Outdoor units: Capacity - 24 HP, Qty - 4 Nos. Air Handling Unit (AHU): Capacity - 13750 CFM, Qty - 2 Nos. Chemical Media filter : Qty - 1 Nos.
SOR ITEM '00050: Comprehensive Maintenance of (3 X 26HP) VRF TYPE AC installed for Security building, with following configuration: Outdoor units: Capacity - 26 HP, Qty - 3 Nos. Indoor Units: a) Ductable split AC: Capacity - 3.0 TR, Qty - 1 Nos Capacity - 8.0 TR, Qty - 3 Nos b) 4-way cassette AC: Capacity - 1.7 TR, Qty - 1 Nos Capacity - 2.3 TR, Qty - 1 Nos Capacity - 2.8 TR, Qty - 3 Nos Capacity - 3.2 TR, Qty - 1 Nos Capacity - 4.0 TR, Qty - 1 Nos b) 4-way compact cassette AC: Capacity - 1.0 TR, Qty - 4 Nos Capacity - 1.3 TR, Qty - 2 Nos Capacity - 1.5 TR, Qty - 2 Nos Treated fresh air units: Capacity - 5.5 TR, Qty - 2 Nos.
SOR ITEM '00060: Comprehensive Maintenance of (3 X 14HP) VRF TYPE AC installed for Fire & safety facility, with following configuration: Outdoor units: Capacity - 14 HP, Qty - 3 Nos. Indoor Units: a) Ductable split AC: Capacity - 3.0 TR, Qty - 2 Nos b) 4-way cassette AC: Capacity - 2.3 TR, Qty - 1 Nos Capacity - 2.8 TR, Qty - 2 Nos Capacity - 3.2 TR, Qty - 5 Nos Treated fresh air units: Capacity - 3.5 TR, Qty - 1 Nos.
SOR ITEM '00070: Comprehensive Maintenance of (2 X 14HP) VRF TYPE AC installed for Workshop, with following configuration: Outdoor units: Capacity - 14 HP, Qty - 2 Nos. Indoor Units (4-way cassette AC): Capacity - 1.7 TR, Qty - 6 Nos Capacity - 2.3 TR, Qty - 1 Nos Treated fresh air units: Capacity - 3.5 TR, Qty - 1 Nos.
SOR ITEM '00080: Comprehensive Maintenance of (2 X 22HP) VRF TYPE AC installed for Warehouse, with following configuration: Outdoor units: Capacity - 22 HP, Qty - 2 Nos. Indoor Units (4-way cassette AC): Capacity - 1.5 TR, Qty - 1 Nos Capacity - 2.8 TR, Qty - 5 Nos Capacity - 3.2 TR, Qty - 1 Nos Treated fresh air units: Capacity - 3.5 TR, Qty - 1 Nos.
SOR ITEM '00090: Comprehensive Maintenance of M/s Bluestar make (3 X 5.5TR) Pacakge AC installed at mounted bullet SRR, including supply of manpower, material (i.e. spares & consumables), tools & tackles, etc. required for successful execution of the job complete in all aspects.
SOR ITEM '00100: Supply of authorised skilled manpower of M/s Bluestar limited for operation and day-to-day upkeep activities of the aforementioned VRF type AC systems installed at IOCL Dumad complex as per the directions of Engineer-in-charge.
SOR ITEM '00110: Manpower cost for 2 Nos skilled
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .