Construction of KGBV Hostel building (first floor) inside the campus of NC high School at Bhadrak under Bhadrak Municipality for the year 2025-26
2025_EICCL_121259_1
SE RandB BDK-25/2025-26-2
Open Tender
Civil Works - Buildings
Percentage
180 days
Bhadrak
Please refer Tender documents.
4 documents required · 4 mandatory
₹10,000
₹72,604
Yes
8 Jan 2026
14 Nov 2025
29 Nov 2025
14 Nov 2025
28 Nov 2025
14 Nov 2025
Dismentling brick masonary or stone masonary in cement mortar above under 3 Mtr.height including stacking the useful materials for reuse and removing the debries away from worksite etc.complete as per direction of Engineer-in-charge.
Dismantling and removing 2.5cm.thick Grading concrete from roof slab and stacking the useful materials for reuse and removing the debries within 50M.lead from worksite etc. complete.
Removal of the dismantined materials (debris) from work site to unwards up to 5 Km lead and from worksite including all cost of labour T&P etc.complete as directed by Engineer-in-charge.
Installation of The above arrangements including all accessories as per Direction of Engg. In charge.
(B ) Column Beam
(C ) Roof Slab
(D ) Stair case
(E ) Chajja
(F ) Shelves
Cutting,straightening, placing and binding of uncoated HYSD bar reinforcement coiled or bent up M.S.Rod or Tor steel of primary steel producers such as SAIL / TISCON / RINL (Grade Fe-500 D) etc. including bending,binding ,welding and jointing if necessary and tying the grills and placing in position as reqd.for RCC work and for providing fan hooks as reqd. hoisting,lowering,laying including cost, conveyance,t axes of M.S.Rod or Tor steel and binding wires of 18 to 20 gauge and labour reqd.for the work for bending,binding and tying the grills in all floors.(Payment will be made on standard weight of B.I.S.for M.S.Rods or Tor steel Only)etc.complete as per direction of Engineer-in-charge.
Fly Ash brick masonary in C.M(1:6)using bricks of size 250cmx120cmx80mm having crushing strength 75kg/cm2 after immersing the bricks for six hours in water before use in Superstructure with all necessary projections, cutting, moulding, corebelling, champering, watering and curing with all cost of materials and labour T&P etc.complete as per direction of Engineer-in-charge.
Fly Ash brick masonary in C.M(1:4)using bricks of size 250cmx120cmx80mm having crushing strength 75kg/cm2 after immersing the bricks for six hours in water before use in Superstructure with all necessary projections, cutting, moulding, corebelling, champering, watering and curing with all cost of materials and labour T&P etc.complete as per direction of Engineer-in-charge.
12mm thick Cement plaster in C.M(1:6)over exterior surface of brick walls after rackingout joint including watering and curing with all cost of materials and labour T&P etc.complete as per direction of Engineer-in-charge.
6 mm thick Cement plaster (1:4)to RCC surface finished smooth including closed deep chipping and slurry treatment with cost conveyance and royality of all materials and labour etc. complete
16mm thick Cement plaster in C.M(1:6)over surface of brick walls after rackingout joint including watering and curing with all cost of materials and labour T&P etc.complete as per direction of Engineer-in-charge.
2.5cm.thick Grading concrete with C.C.(1:2:2)on roof slab using 6mm size BHG(C.B) chips of appd. quality from appd. quarry including hoisting,lowering,laying and compactiung concrete watering and curing etc.complete as directed by the Engineer-in-charge.
Providing,fitting and fixing Vetrified floor tiles in floors,treads and steps over 600mm X 600mm (Coloured & Printed) of approved make confirming to IS 13755 lail on 20mm thick Cement Mortar (1:4) (1 Cement 4 Sand) and filling joints with white cement of approved quality with pigment to match the shades of tiles including all cost of materials and labour T&P etc. reqd. for the work complete as per direction of Engineer-in-charge.
Providing,fitting and fixing Vetrified floor tiles in dadoos Skirtings and riser of steps over 600mm X 600mm (Coloured & Printed) of approved make confirming to IS 13755 lail on 12mm thick Cement Mortar (1:3) (1 Cement 3 Sand) and filling joints with white cement of approved quality with pigment to match the shades of tiles including all cost of materials and labour T&P etc. reqd. for the work complete as per direction of Engineer-in-charge.
Providing,fitting and fixing Vetrified Industrial floor tiles (Plain) in floors of size 300mm X 300mm of approved make confirming to IS 13755 lail on 20mm thick Cement Mortar (1:4) (1 Cement 4 colours Sand) and filling joints with white cement of approved quality with pigment to match the shades of tiles including all cost of materials and labour T&P etc. reqd. for the work complete as per direction of Engineer-in-charge.
Providing,fitting and fixing Vetrified Industrial tiles of size 300mm X 300mm size in dadoos skirtings and riser of steps on 12 mm thick bed of on thick Cement Mortar (1:4) (1 Cement 3 Sand) and filling joints with white cement of approved quality with pigment to match the shades of tiles including all cost of materials and labour T&P etc. reqd. for the work complete as per direction of Engineer-in-charge.
Supplying fitting and fixing of fully glazed U- PVC Silding window of approved make with 6mm thick glass of approved quality complete with frame shutters of approved make and Design with necessary screws and nails including all cost of materials and labour T&P etc.complete as directed by Engineer-in-charge.
Supplying fitting and fixing U-PVC door shutters with frame necessary screws and nails including all cost of materials and labour T&P etc.complete as directed by Engineer-in-charge.
Supplying fitting and fixing of M.S. Flat of 20 x 20 x 6mmGrills, Grill gate, M.S.Gates, M.S.door, M.S.Angle , M.S.Shutter with Choukaaths ,Collapsible gates with top and bottom rails,steeel windows critical frames for windows ,staircase and parapet railing made out of M.S.Square bar / flat including .as per approved drawing and design with cost of all materials and labour, taxes, labour cess, T&P sundries etc.complete in all respect as per specification and direction of the Engineer-in-charge.
Labour for fitting and fixing M.S Window Grills with M.S flat of 20x20x6mm size including welding with cost of all materials charges for .complete as per direction of Engineer-in-charge.
Labour for fitting and fixing M.S Gollapsible Gate with M.S flat of 20x20x6mm size including welding with cost of all materials charges for .complete as per direction of Engineer-in-charge.
Finishing the plastered surface of wall with cement based Wall Putty (Water based ) of approved make and finishing the surface smooth and even by sand papering to receive paint in wall including all cost of materials and labour T&P etc.complete as directed by Engineer-in-charge.
Painting two coats to wall surface with approved plastic emulsion paint of appd.shade including all cost of materials and labour T&P etc.complete as directed by Engineer-in-charge.
Finishing wall surface with water proofing weather coat paint two coats over a coat of primer to give an even shade over the plastered surface of brick walls including all cost of materials and labour T&P etc.compete as directed by Engineer-in-charge.
Painting two coats with enamel paint of appd. shade Door/window over wood / Iron work over a coat of primer including all cost of materials and labour T&P etc.complete as directed by Engineer-in-charge.
Providing for supplying fitting and fixing of stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with balustrade of 32mmx32mmx2mm @ 0.90 mtr.C/C and stainless square pipe bracings of size 32mmx32mmx2mm in three row in stair case as for and specification butting polishing etc. approvede design including all cost of materials and labour T&P etc.complete as per direction of Engineer-in-charge.
EachCum.
(B ) Lintel
(C ) Roof Slab
(D ) Chajja
Cutting,straightening, placing and binding of uncoated HYSD bar reinforcement coiled or bent up M.S.Rod or Tor steel of primary steel producers such as SAIL / TISCON / RINL (Grade Fe-500 D) etc. including bending,binding ,welding and jointing if necessary and tying the grills and placing in position as reqd.for RCC work and for providing fan hooks as reqd. hoisting,lowering,laying including cost, conveyance,t axes of M.S.Rod or Tor steel and binding wires of 18 to 20 gauge and labour reqd.for the work for bending,binding and tying the grills in all floors.(Payment will be made on standard weight of B.I.S.for M.S.Rods or Tor steel Only)etc.complete as per direction of Engineer-in-charge.
Fly Ash brick masonary in C.M(1:6)using bricks of size 250cmx120cmx80mm having crushing strength 75kg/cm2 after immersing the bricks for six hours in water before use in Superstructure with all necessary projections, cutting, moulding, corebelling, champering, watering and curing with all cost of materials and labour T&P etc.complete as per direction of Engineer-in-charge.
2.5cm.thick Grading concrete with C.C.(1:2:2)on roof slab using 6mm size BHG(C.B) chips of appd. quality from appd. quarry including hoisting,lowering,laying and compactiung concrete watering and curing etc.complete as directed by the Engineer-in-charge.
12mm thick Cement plaster in C.M(1:6)over exterior surface of brick walls after rackingout joint including watering and curing with all cost of materials and labour T&P etc.complete as per direction of Engineer-in-charge.
16mm thick Cement plaster in C.M(1:6)over surface of brick walls after rackingout joint including watering and curing with all cost of materials and labour T&P etc.complete as per direction of Engineer-in-charge.
6 mm thick Cement plaster (1:4)to RCC surface finished smooth including closed deep chipping and slurry treatment with cost conveyance and royality of all materials and labour etc. complete
Supplying fitting and fixing of M.S.Grills, Grill gate, M.S.Gates, M.S.door, M.S.Angle , M.S.Shutter with Choukaaths ,Collapsible gates with top and bottom rails,steeel windows critical frames for windows ,staircase and parapet railing made out of M.S.Square bar / flat including .as per approved drawing and design with cost of all materials and labour, taxes, labour cess, T&P sundries etc.complete in all respect as per specification and direction of the Engineer-in-charge.
Labour for fitting and fixing M.S Window Grills with M.S flat of 20x20x6mm size including welding with cost of all materials charges for .complete as per direction of Engineer-in-charge.
Labour for fitting and fixing M.S M.S. Door with M.S flat of 20x20x6mm size including welding with cost of all materials charges for .complete as per direction of Engineer-in-charge.
Finishing the plastered surface of wall with cement based Wall Putty (Water based ) of approved make and finishing the surface smooth and even by sand papering to receive paint in wall including all cost of materials and labour T&P etc.complete as directed by Engineer-in-charge.
Painting two coats to wall surface with approved plastic emulsion paint over coat of Primer of appd.shade including all cost of materials and labour T&P etc.complete as directed by Engineer-in-charge.
Finishing wall surface with water proofing weather coat paint two coats over a coat of primer to give an even shade over the plastered surface of brick walls including all cost of materials and labour T&P etc.compete as directed by Engineer-in-charge.
Painting two coats with enamel paint of appd. shade Door/window over wood / Iron work over a coat of primer including all cost of materials and labour T&P etc.complete as directed by Engineer-in-charge.
Supplying and making end termination with brass double compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. 3.5core x 95 sq mm ( FOR main OFP )
GROUP-B
GROUP-C
Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( ( flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( ( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius ) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)(( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
Supplying,fixing of 1x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+1 no 6A switch & socket(modular type) ( flame retradant type) with suitable size modular box & metallic cover plate (both side) falme retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius/Panasonic (vision) (For equipement power)(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5)
Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5)
Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5)
Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit .(LFDB TO FLOOR PANEL TO TPN BDB power) (4X10+2X6)
Supplying and installation of 25A AC starter Modular type, Schneider/Siemens/Legrand coil voltage-230 Volt A.C. on mod Box of suitable size including modular coveras required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
Supply and fixing CALL bell (Ding dong type) /Buzzer on t
S/F of Bakelite angle holder/batten holder (make-Anchor/Havells )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision)
Sub-Head II (Light fitting Fixture & Fan)Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years.
Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years..
Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years
SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years .
Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge . (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved.
BDBS,DB,AC DB,FLOOR PANELS,MCBSSupplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB(ITUS) as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years. 4 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years
2+4 way MCB Enclosure DB (GLAZED door)(only each EM. CONNECTION UPS LOAD)Warranty on DB is 3 years
Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, single poles MCB of legrand dx3/ schneider acti9 A9N/ Siemens betaguard/ ABB ( SB 200). the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 3 years.
Supplying and fixing 6-32 amps rating, 240 volts, C series,10KA breaking capacity, Double poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 3 years.
Supplying and fixing 63Amps rating,C series,10KA breaking capacity, 4P 415 volts MCB Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 /ABB(SB 200) in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..The MCB should be Replacement Warranty will be 3 years.
Supplying and fixing 63Amps 4P 415 volts RCCB 30 mA Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB (FB 200) in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..The RCCB should be Replacement Warranty will be 3 years.
Providing and fixing 6SWG GI wire on surface or in recess for loop earthing as required as per direction of Engg.-in-Charge.
Providing and fixing 25mm x 5 mm G.I strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge.
Inverter installationSupply & Fixing Of 150 AH inverter Batterywith all Connection & acessoseries(Make-Luminous/exide/Microtek)
Supply & Fixing of 4.5 KW Inverter Machinewith all Connection & acessoseries (Make-Luminous/exide/Microtek)
Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Tra
ys should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge.
CABLING AND END TERMINATION MAIN AREASupplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. 3.5core x 95 sq mm ( FOR main panel )
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
EXTINGUISHER SYSTEMSupply,Installation,Testing and Commisioning of ISI marked (IS:2878) Fire Extinguisher ,Carbon di-oxide type capacity 4.5kg with all accessories (Ever safe/Fire shield/Ceasefire/Safex)
Supply,Installation,Testing and Commisioning of ISI marked (IS:2878) Fire Extinguisher ,ABC type capacity 6kg with all accessories (Ever safe/Fire shield/Ceasefire/Safex)
Fire buckets (FILLED WITH SAND) round bottom type enamel painted, white inside & Red out side and Letter "FIRE" in black out side and handle with mounting bracket.
SIGNAGESFire Exit signage at each stair on every floor, indicating the direction of fire exit, lettering size shall be 7.5 cm with contrasting color from back ground. Size shall be 15cm x 45cm.
Providing and fixing in position the signage of " Fire Extinguisher " to be fixed above the every extinguisher. Size 6" x 8"
Lightning Protection :- Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn
Supply of Roof conductor holder for parapet- Polyamide Conductor holder:With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn
Supply of Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance. Tested as per IEC 62561. Make-OBO/Dehn
Supply of Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Tested as per IEC 62561.(2nos/expansion piece ).Make-OBO/Dehn
Supply of 1 mtr vertical air terminal with mounting accessories on the flat surface to meet the requirements of IS/IEC 62305. Tested for Electrical , mechanical and chemical as per IEC 62561. Tested for 100kA lightning current. Make-OBO/Dehn
Supply of Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3 Nominal size Ø10/16 mm aluminium rod: 3 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. Tested as per IEC 62561. Make-OBO/Dehn
Supply for Providing of Stand for Fang Fix system 16 kg with base and clamp ,made up of frost resistant concrete and clamp tested upto 100KA lightning current . Make-OBO/Dehn
Supply for Providing of Stand for Fang Fix system 16 kg made up of frost resistant concrete. Make-OBO/Dehn
Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer. Tested for 100kA lightning current. Make-OBO/Dehn
Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr Height For Test Joint .Internal dimensions: 100x100x48 mm Make-OBO/Dehn
Supply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561. Make-OBO/Dehn
Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Make-OBO/Dehn
Supply of flat conductor holder- Fit: FL 30, With mounting hole 6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from hot-dip galvanised steel, Bottom section from polyamide, black. Tested as per IEC 62561. Make-OBO/Dehn
Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. Make-OBO/Dehn
Supply of UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 17.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2 Make-OBO/Dehn
Supply of universal clamp made of SS to connect rod with flat conductor Make-OBO/Dehn
Supply of Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested Make-OBO/Dehn
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.30 MB
BOQ_564318.xls
BOQ • 0.35 MB
2DTCNK.pdf
Tender Documents • 2.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .