| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹74.7 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹78.6 L+₹2.1 L (2.74%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹83.0 L+₹6.5 L (8.44%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹91.9 L+₹15.4 L (20.2%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹1.0 Cr+₹24.4 L (31.9%)Rejected-AOC KATTUPADATH H AZHEEKAL PO VYPEEN 682508 | KOCHI | ERNAKULAM | KERALA | 682508 | L5 | Rejected-AOC Rejected |
Tender Value
₹80 L
EMD Value
₹1.4 L
Closing Date
11 Apr 2024, 6:00 pmClosed
Shri DC Sharma IDSE CWE(NW) Kochi
CWE(NW) Kochi
SPECIAL REPAIR TO P-17 STORE HOUSE AND P-20A CLOTHING GODOWN AT BV YARD KOCHI
2024_MES_645584_1
CWE(NW)KOCHI/81431
Open Tender
Civil Works
Item Rate
270 days
Kochi
As per NIT
6 documents required · 6 mandatory
₹1,000
GE(NW) Kochi
₹1.4 L
Yes
3 Jun 2024
7 Mar 2024
15 Apr 2024
7 Mar 2024
11 Apr 2024
28 Mar 2024
Amount
Taking down of existing roof treatment consisting of screed bed plaster tar felts etc and removal of dismantled materials complete all as specified and directed by Engr in Charge.
M&L for Cement concrete type B- 1, 1:2:4 (20mm graded aggregate) for coping or chamfered on edges and. levelling coarses of concrete in roof slab all as specified and as directed.
Supply and fix Galvanized Z sections (Z shaped GI subgrit of size 50X50X50-2MM THICK) as in purlins where connected on RCC slab with fastner of 10mm dia and 40mm long and galvalume sheet connected to Z purlin with SDST screws of 12GX14 TPI-55mm (L) complete all as specified and as directed by the Engineer-in-Charge. Note:-The rate inclusive of the rate of fastner and SDST screws)
Providing and applying pitch free polyethene water proof coating using Fosroc Nitoproof 600 or equivalent, over dry surface at 1.5mm thick in 2 coats with interval period of 6 hours over a substrate at coverage rate of 2Kg/Sqm using spray/squeege/ roller/ brush. Water proofing coating shall have the elongation of 200% (ASTM D412-90, Tear resistance of >7N (ASTM D 624-00), and tensile strength of 1.5N/mm2 (ASTM D412-90) and it should have a solid content of 80-85% (The rate includes the application of the chemical with specialized agency or the manufacturer)
S&F Pre-painted galvalume aluminum zinc coated GI based corrugated steel sheet 0.50mm thick of any colour, having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, ridge , Gutter, Gable flashing, corner flashing etc, fixed with self tapping screws as specified and directed.
Taking down cement plaster of any description on brick work or stone masonry walls including rackingout joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engr-in-Charge.
M&L 15mm thick rendering in cement mortar (1:6) on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
M&l for rendering 8mm thick in CM 1:4 using liquid WPC over 12mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces finished even & fair without using extra cement complete all as directed. Note: Supply only water proofing compound shall be paid separately.
M&L 5mm thick rendering in ceiling of cement mortar (1:3) on fair faces of brick work or concrete surfaces, finished the surfaces even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
Supply only liquid water proofing compound complete all as specified and directed by Engr-in-Charge.
M&L for preparation of old ceiling surface and applying two coats of Oil Bound Distemper on ceiling complete all as specified and directed. Note:The height of ceiling is more than 10 mts. Cost of necessary scaffolding shall be included in the quoted rate.
M&L for two coats of oil bound distemper over a coat of 1.5mm thick wall care putty to newly plastered surface including preparation of surfaces complete all as specified and directed by Engr-in-Charge.
M&L for complete removal of existing surface finishes of external wall,preparation of surface and apply one coat of alkali resistant exterior primer over 1.5mm thick exterior grade wall care putty and allowed to dry over night before applying first coat of weather proof (premium acrylic emulsion paint alkali & fungal resistance,dirt resistance exterior paint) ) complete all as specified and as directed. Note :- Before application of primer coat, the moisture of the wall surface shall be checked with a moisture meter.
M&L preparation of new plastered external surface and apply one coat of alkali resistant exterior primer over 1.5mm thick exterior grade wall care putty and allowed to dry over night before applying first coat of weather proof (premium acrylic emulsion paint alkali & fungal resistance, dirt resistance exterior paint) ) complete all as specified and as directed. Note :- Before application of primer coat, the moisture of the wall surface shall be checked with a moisture meter .
M&L for application of first coat of weather proof paint (premium acrylic emulsion paint alkali & fungal resistance, dirt resistance exterior paint of required shade ) ( Asian paint apex ultima protek or equivalent of Berger /Nerolac ) on primed wall surface using spray application or mechanical means, to get a smooth and tint free surface and allowed to dry for at least 8 hrs/ overnight to receive second coat of acrylic exterior emulsion paint complete all as specified and as directed.
M&L for application of second coat of weather proof paint (premium acrylic emulsion paint alkali & fungal resistance, dirt resistance exterior paint of required shade ) ( Asian paint apex ultima protek or equivalent of Berger /Nerolac ) over first coat on wall surface using spray application or mechanical means, to get a smooth and tint free surface complete all as specified and as directed. Note for item No. 14 to 17: (i) The old surface shall prepared using mechanical ways I.e., jet-spray, grinding etc., in such a manner that there should not be any impression of dent, all cracks to be filled with crack filler, water proofing primer in shaft/dampness areas and it should be made even all as per manufacturers instruction before application of putty base primer/base coat and emulsion paint. (ii). The work shall be got executed through authorised applicator of approved manufacturer. Authorisation letter of applicator shall be produced by the contractor before starting the work (iii) The contractor shall submit performance Guarantee certificate provided by manufacturer for a period of FIVE years from the certified date of completion of entire work. (iv) After preparation of surface exterior putty to be applied to make surface even to receive base coat and two coat of emulsion paint, the same shall be got approved by GE before each stage.
M&L for preparation of old ceiling surface and One coat of white wash on ceiling complete all as specified and directed by Engr-in-Charge.
M&L for preparation and complete removal of existing treatment and applying two coats of Oil bound distemper over a coat of 1.5 mm thick wall care putty complete all as specified and directed. Note:- Application of paint, primer and wall care putty shall be as per manufacturer's instruction.
M&L for preparation of old painted steel surfaces of any description, not otherwise described and applying one coat of synthetic enamel paint over 10cm width or girth complete all as specified and as directed by Engr-in-Charge
Demolition of cement concrete (Un-reinforced) in ground floors and pavings n.exc 15cm thick (above or below GL) complete all as specified and directed by Engr-in-Charge.
M&L 75mm thick PCC (1:3:6) type C-2 (Using 20mm graded crushed stone aggregate) as in plinth protection /hardstanding , laid in panels, finished the top surfaces even and fair without using extra cement complete all as specified and directed by Engr-in-Charge.
Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engr-in-Charge.
M&L for Machine cut pre polished Kota stone slab 18-20mm thick as in floor/ treads of steps (single piece) laid over and including 15mm thick screed in CM 1:4, set & jointed with grey cement slurry and pointed in white cement mixed with pigment to match the shade of the slab including cutting, rubbing complete all as specified and directed by Engr-in-Charge.
M&L for machine cut pre polished Kota stone slab 18-20 mm thick (single piece) as in risers to steps, skiting/dado, pillars, window cills and the like, laid over and including 10mm thick rendering in cement mortar 1:3, set & jointed with grey cement slurry and pointed in white cement mixed with pigment to match the shade of the slab including cutting, rubbing and polishing complete all as specified and directed by Engr-in-Charge.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engr-in-Charge.
M&L RCC (1:2:4) type B-1 (Using 20mm graded crushed stone aggregate) as in slabs, shelves supported on walls, beams and columns in floor or roof including balconies, canopies, deck slabs or in Chajja/facia projection and the like complete all as specified and directed by Engr-in-Charge.
M&L mild steel CRS bars 10mm dia and over, cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engr-in-Charge.
Formwork to chullah hoods, chajjas, troughs & similar items including edges.
Repairs to Aluminum door shutter / windows of any size including taking down and cleaning / repairing / replacement of all fittings and fixtures (If required) and re-fixing in the same opening complete all as specified and directed at site by Engineer-in-Charge.
S/F 4mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with stainless steel screws complete all as specified
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/blankets, any thickness including cover fillets.
S/F Aluminum snap grid false ceiling with grid 605x605mm size including hangers 6 mm dia GI (upto 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flats 40 x 3 mm size 60 mm long & expansion hold fastners 12.5 mm dia 40 mm long complete all as specified.JINDAL/INDAL/HINDALCO)
Dismantling wrought iron or mild steel work of any description complete all as specified
M & L Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
M&L for Welded steel wire fabric of thickness more than 3mm and weight n.exc 4kg/ sqm fixed to steel members complete and specified.
Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.5 litres per sq.m of the vertical surface of the sub-structure to a depth of 300mm including excavating channel along the wall and rodding etc.complete all as specified
Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and directed
Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed
Dismantling single layer MP roofing tiles including ridges complete all as specified and directed.
Dismantling plain or corrugated steel sheeting, any guage, thickness incl Nainital or similar pattern roof covering complete all as specified and directed
Dismantling timber scantlings under 40 sqcm in sec in fillets, rails, posts, rafters, purlins etc, in unframed works complete all as specified and directed.
Same as per Item No 42 but over 40 sqcm in sec in fillets, rails, posts, rafters, purlins etc, in unframed works complete all as specified and directed.
Dismantling battens for tiles, shingles etc spaced exc 15cm of any size incl tilting fillets complete all as specified and directed
M&L for 2nd class hard wood in scantling clean sawn fixed as in purlins, rafters, etc in roof complete all as specified and directed
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed
S&F 200mm dia of half round or 220mm width rectangular UPVC eaves gutter with union sockets and joints set in approved jointing compound incl supports/ brackets and fittings etc complete all as specified and directed
S&F PVC rain water pipes 110mm dia including bend, elbow, iron brackets for fixing etc complete all as specified
M&L for Rolled sections (Tublar sections) as in main pillars and cross beams, hip and jack rafters, purlins where connected to common rafters and fixed with angle cleats or other connecting plates complete all as specified and directed.
M&L for preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed.
S&F 0.63mm thick glavanised corrugated mild steel sheeting with two corrugation side lap fixed with 'L' type or 'J' type hook bolts and washers in roofs with grade of zinc coating 275 complete all as specified and directed.
Taking down chowkats or frames not exceeding 1.5 Sqm each but with shutters (without taking off shutters from the frames) all as specified.
Taking down chowkats or frames exceeding 1.5 Sqm but not exceeding 4.0 sqm each but with shutters (without taking off shutters from the frames) complete all as specified.
M/L 2nd class Hw Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and directed.
M/L 2nd class HW 35mm thick Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed.
M&L 30mm thick IInd class hardwood glazed and skeleton shutters , open rebated and prepared to receive glass gauge etc, edges of framing plain chamfered or rounded, fitted with cut and mitered beads for securing glass etc, size of members of shutter as specified in SSR (Part-I)- 2009 complete all as specified and directed.
M/L PCC 1:2:4 type B-1,using 20mm graded stone aggregate for fixing holdfast including necessary form work complete all as specified and directed.
S/F Mild steel work in bands, straps, support for rainwater pipe, MS holdfast made out of FI 25x3mm etc complete conforming to Fe-290 Gde-E-165 complete all as specified and directed.
S/F 100 mm long mild steel butt hinges medium weight complete all as specified and directed.
S/F 75 mm long mild steel butt hinges medium weight complete all as specified and directed.
S&F aluminum anodized barrel tower bolt 200mm long of extruded section complete all as specified and directed.
S&F aluminum anodized barrel tower bolt 100mm long of extruded section complete all as specified and directed.
S&F aluminum anodized sliding door bolt 300mm long with hasp and staples (bolt type) and fixing clips of sheet cast of extruded section and fixing bolts and sliding bolts of extruded section complete all as specified and directed.
S&F aluminum bow handle "D" type anodized 150mm long complete all as specified and directed.
S&F aluminum bow handle "D" type anodized 100mm long complete all as specified and directed.
M & L 2nd Class hardwood Plain fillets. square, rectangular or triangular in section exc 6 sq cm not exc 13 Sq cm , clean sawn, secured with nails or brads complete all as specified
S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in square n.exc 0.5 Sqm each pane complete all as specified and directed.
M/L preparation of new wooden Surfaces of any description, not otherwise described, over 10cm width or girth and applying 2 coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed by Engineer-in-Charge.
M&L point wiring with 1.5 Sqmm PVC insulated sheathed FRLSH multistranded single core copper conductor cable in concealed stove enamelled steel (metallic) conduit ( ISI marked ) fixed concealed on wall /roof except beam, column and RCC roof including chases cutting incl suitable for modular switch and socket (sunken box) modular white cover plate,flush metal box etc incl 1.5 Sqmm PVC insulated copper conductor as earth continuity wire for One light /Fan point controlled by one switch and making good disturbed surfaces of walls, floors,etc complete all as specified and as directed by Engineer-in-Charge.
All as per item No 70.above but for one 5 pin 5 amps socket outlet on the same board complete all as specified and as directed by Engineer-in-Charge.
All as per item No 70.above but for one 5 pin 5 amps socket outlet an independent board complete all as specified and as directed by Engineer-in-Charge.
All as per item No 70 above but with 2.5 Sqmm copper conductor including 2.5 Sqmm copper cable on earth wire for one 6 Pin 16 Amps Socket outlet independent board complete all as specified and as directed by Engineer-in-Charge.
All as per item No 70 above but with 4 Sqmm copper conductor including 4.0 Sqmm copper cable on earth wire for sheet metal enclosure complete all as specified and as directed by Engineer-in-Charge.
S & F modular switch 1 way 6 Amps,1 module type complete all as specified and as directed by Engineer-in-Charge.
S & F socket modular 6 Amps and 2/3 pin combined 2 module complete all as specified and as directed by Engineer-in-Charge.
S & F switch 15 A One way SP modular type 2 module complete all as specified and as directed by Engineer-in-Charge.
S & F Modular socket 6 A/16 A - 2/3 pin combined 2 module complete all as specified and as directed by Engineer-in-Charge.
S&F ceiling rose surface bakelite 65 x 50mm 3 terminals complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repairs of metallic exhaust fans AC single phase 230/ 240 V of size 450 mm sweep complete all as specified and as directed by Engineer-in-Charge. Model - TurboForce SP of Havells or any other equivalent make in the approved manufactures list. NOTE : Old exhaust fan shall be deposited to MES Store Yard.
Supply and fixing Wall mounted fans of size 450 mm sweep AC single phase 230 / 240 V complete all as specified and as directed by Engineer-in-Charge. Make : Turbo force of Havells or any other equivalent make in the approved manufactures list. NOTE : Old wall mounted fan shall be deposited to MES Store Yard.
Supply & fix Regal Batten for LED tube lights, both side connection type and LED tube rod 1 x 20 Watt, 120 Lum/Watt, both side connection complete all as specified and as directed by Engineer-in-Charge. Make of batten : Havells Cat Part No. Regal batten 8UPT001X22WSSBSWH Make of tube rod : Havells Cat Part No. Crystal 1213T8DSTL20W LED 865 GLASS or any other equivalent make in the approved manufactures list.
Supply and fix LED street light 35Watt, 120 Lum/Watt, IP 65 protection including all accessories and suitable GI pipe for fixing on wall including all connection complete all as specified and as directed by Engineer-in-Charge. Make: Cat Part No:LSTS-36-CDL-M of Crompton or any other equivalent make in the approved manufactures list.
S&F Sheet metal enclosures with socket plug top and MCB' single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 20 A MCB complete all as specified and as directed by Engineer-in-Charge.
Taking down old DBs from existing position including MCB,s complete all as specified and as directed by Engineer-in-Charge.
S&F Sheet metal enclosure SPN DB when MCB's to be used 4 way with 200 amps bus bar double door, complete all as specified and as directed by Engineer-in-Charge.
S&F Sheet metal enclosure SPN DB when MCB's to be used 8 way with 200 amps bus bar double door, complete all as specified and as directed by Engineer-in-Charge.
S&F Sheet metal enclosure TPN DB when MCB's to be used 4 way with 200 amps bus bar double door, complete all as specified and as directed by Engineer-in-Charge.
S&F MCCB TPN 100 amp ,415 volts ,16 KA complete all as specified and as directed by Engineer-in-Charge.
S&F of MCCB enclosure of capacity 100 Amps TPN complete complete all as specified and as directed by Engineer-in-Charge. Make : Legrand Cat Part No. 5078 01 or any other equivalent make in the approved manufactures list.
S&F MCB TPN 100 Amps Amp ,240 Volts,10 KA complete all as specified and as directed by Engineer-in-Charge. Cat part No -AU15S41003C of L&T or any other equivalent make in the approved manufactures list.
S&F MCB 'B' Curve 63 Amp SPN ,240 Volts complete all as specified and as directed by Engineer-in-Charge. Make L&T Cat Part No. BB20630B or any other equivalent make in the approved manufactures list.
S&F MCB 'B' Curve 6-32 Amp SPN ,240 Volts complete all as specified and as directed by Engineer-in-Charge. Make L&T Cat Part No. BB20060B to BB20320B or any other equivalent make in the approved manufactures list.
S&F MCB 'B' Curve SP 6 to 32 Amp, 240 Volts, complete all as specified and as directed by Engineer-in-Charge. Make L&T Cat Part No. BB10060B to BB10320B or any other equivalent make in the approved manufactures list.
Taking down old sub main wiring of any size complete all as specified and as directed by Engineer-in-Charge.
M&L for sub main wiring using proper colour coding 1100 Volts grade with 2 runs of 4 Sqmm (FRLSH) grade PVC insulated unsheathed multistranded copper conductor cable and 1 run of 4 Sqmm (FRLSH) cable as earth continuity wire drawn through and including PVC conduit medium grade not less than 25 mm dia with all conduit accessories concealed in wall/floor including cutting chesses and making good disturbed surface to match with existing surface complete all as specified and as directed by Engineer-in-Charge. Note - 2 runs of 4 Sqmm wire and one run of 4 sq mm wire for earthing and PVC conduit pipe with accesories shall be measured as one unit.
M&L for sub main wiring using proper colour coding 1100 Volts grade with 4 runs of 6 Sqmm (FRLSH) grade PVC insulated unsheathed multistranded copper conductor cable and 2 run of 6 Sqmm (FRLSH) cable as earth continuity wire drawn through and including PVC conduit medium grade not less than 25 mm dia with all conduit accessories concealed in wall/floor including cutting chesses and making good disturbed surface to match with existing surface complete all as specified and as directed by Engineer-in-Charge. Note - 4 runs of 6 Sqmm wire and 2 run of 6 sq mm wire for earthing and PVC conduit pipe with accesories shall be measured as one unit.
All as per item No 97 but 2 single core 6 Sqmm with 6 Sqmm earth wire complete all as specified and as directed by Engineer-in-Charge. Note - 2 runs of 6 Sqmm wire and one run of 6 sq mm wire for earthing and PVC conduit pipe with accesories shall be measured as one unit.
M & L in repair XLPE insulated, galvanised steel strip or wire armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area 25 sq.mm 4 core including taking down old unserviceable cable complete all as specified and as directed by Engineer-in-Charge.
Material and labour earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm buried directly in ground to a depth not less than 2.25m below ground level with top edge of the earth plate at a depth not less than 1.5m below normal ground level surrounted from all side by 15 cm of thick and packed layers of charcoal dust and common salt ,filling alternate layers and electorde connected by using GI wire 4 mm dia (max -length of 7.5 mtrs )by means of bolts,nut and washer of GI and providing GI light grade pipe 15 mm dia as prrotection pipe for GI wire connected main controll board / test point and provided with GI pipe of light grade 20 mm bore for watering and including funnel,wire mesh PCC chamber of 1;3;6 type C1 ,and RCC cover of 1;2;4 type B1 including necessary earth work in any type of soil /strata disposal of soil all as directed and shown in electricall plate No. 3 of SSR part -1 including testing on completion complete all as specified and as directed by Engineer-in-Charge.
Excavation in trenches for not exc 1.5 mtr wide and not exc 1.5 mtr depth and getting out in soft/loose soil including taking out faulty cable/cable, cable covers and GI pipe complete all as specified and as directed by Engineer-in-Charge.
Returning filling in including spreading levelling watering and well ramming in layers n.exc 25cm complete all as specified and as directed by Engineer-in-Charge.
Removing excavated materials n.exc 50m and depositing where directed at a level n.exc 1.5m above the Starting pointcomplete all as specified and as directed by Engineer-in-Charge.
M & L for riddle sand as sand cushioning for protection of UG cable including punning of sand in layers complete all as specified and as directed by Engineer-in-Charge.
Supply & laying un-reinforced precast concret cable cover class LV type 1, flat size 250mm x 150mm x 40 mm complete all as specified and as directed by Engineer-in-Charge.
M&L for point wiring with 1.5 Sqmm(FRLSH) insulated unsheathed multistranded single core copper conductor cable in concealed stove enamelled steel (metallic) conduit with all accessories incl MS sheet pressed terminal box (recessed) with laminated sheet cover for housing switches , sockets etc or PVC moulded switch boards for accommodating switches/sockets etc. and 6 pin 15 amps switch socket outlet point on independent board with 2.5 sqmm (FRLSH) PVC insulated unsheathed stranded copper conductor with 2.5 sqmm PVC (FRLSH) insulated stranded copper wire for continuous earthing for one light point/ exhaust fan point/ wall mounting fan point complete all as specified and directed by Engr-in-Charge.
All as per item No 106.above but for one 5 pin 5 amps socket outlet on the same board complete all as specified and as directed by Engineer-in-Charge.
All as per item No 106.above but for one 5 pin 5 amps socket outlet an independent board complete all as specified and as directed by Engineer-in-Charge.
All as per item No 106 above but with 2.5 Sqmm copper conductor including 2.5 Sqmm copper cable on earth wire for one 6 Pin 16 Amps Socket outlet independent board complete all as specified and as directed by Engineer-in-Charge.
All as per item No 106 above but with 4 Sqmm copper conductor including 4.0 Sqmm copper cable on earth wire for sheet metal enclosure complete all as specified and directed complete all as specified and as directed by Engineer-in-Charge.
S&F LED flood light made up of pressure die cast housing with toughened glass and high power LEDs with option of secondary optic with IP 66 protection, 3000 K, with 10 KV SPD of 50 watt, 120 Lumen/Watt complete all as specified and as directed by Engineer-in-Charge. Make Crompton, Cat Part No. LFL-80-CDL/60-M or any other equivalent make in the approved manufactures list.
S&F Sheet metal enclosure TPN DB when MCB's to be used 8 way with 200 amps bus bar double door, complete all as specified and as directed by Engineer-in-Charge.
S&F MCCB TPN 200 amp ,415 volts ,16 KA complete all as specified and as directed by Engineer-in-Charge. Make : L&T Cat Part No. CM90634OOPO or any other equivalent make in the approved manufactures list.
S&F of MCCB enclosure of capacity 200 Amps TPN complete complete all as specified and as directed by Engineer-in-Charge. Make : L&T Cat Part No. SK95418 or any other equivalent make in the approved manufactures list.
Bell Builders
ARCHITRAVE CONSTRUCTIONS
M/s ANTONY THOMAS AND CO
MS BUILDERS
Kaadosh Real Estates Pvt Ltd
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .