Tender Value
₹51 L
EMD Value
₹1.0 L
Closing Date
27 Jun 2024, 6:00 pmClosed
Col Manish Dhaka CWE
HQ CWE (AF) Chiloda Military Engineer Services P.O CRPF Campus Vayu Shakti Nagar Gandhinagar 382042
REPAIR REPLACEMENT OF INTERNAL ELECTRIFICATION FITTING FIXTURE LIGHTS SPN TPN DBs SUBMAIN WIRING MCCBs MCBs LT CABLES AND COOLING APPLIANCES AND CONNECTED ACCESSORIES AT BISAG N GANDHINAGAR
2024_MES_656469_1
82200/CHL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GANDHINAGAR
As per tender documents
7 documents required · 7 mandatory
₹1,000
Yes
GE (AF) Chiloda
₹1.0 L
Yes
9 Dec 2024
29 May 2024
4 Jul 2024
29 May 2024
27 Jun 2024
20 Jun 2024
30 May 2024 - 1 Jun 2024
Amount
Taking down carefully old unserviceable copper/ aluminium point wiring (Light, fan, socket, power and Bell) including fixture and fittings such as switches, sockets, ceiling roses, lamp, holder , regulators, sockets light fittings etc , removing material to store for keeping in safe custody or for taking credit , and making good disturbed surface of walls, floors, etc. complete all as specified and directed by Engr in Charge.
M&L Point wiring with modular accessories ,modular metal flush box and cover plate with frame of suitable size complete with 1.5 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 1100 volts grade drawn through metallic rigid / PVC heavy duty concealed conduit/ casing capping/open conduit with 1.5 sqmm, single core, PVC insulated but unsheathed multistranded copper conductor FRLS cable 1100 volts grade as earth continuity wire terminated in new modular sunken boxes and modular metal flush box as required size at site incl all connected accessories , box made from not less than 1.6 mm GI sheet factory made complete all as specified and directed by Engr in Charge. for the following.
One light/bell/fan point controlled by one switch complete
One 3 pin socket out let 5 Amps on the independent board.
One 3 Pin socket out let 5 Amps on the same board.
Ditto- all as per item No.2 above but with cable of size 2.5 Sq mm PVC insulated on independent board for Power plug/sockets 15 Amps. Complete all as specified and directed by Engr in Charge.
S&F Modular switch one way 6A,1 Module, as per existing make as approved by GE complete all as specified and directed by Engr in Charge.
S&F Modular switch one way 16A,1 Module, as per existing make as approved by GE complete all as specified and directed by Engr in Charge.
S&F Modular socket 6/10A-2/3 pin combined 2 Module as per existing make as approved by GE complete all as specified and directed by Engr in Charge.
S&F Modular socket 16/15A-2/3 pin combined 2 Module as per existing make as approved by GE complete all as specified and directed by Engr in Charge.
S&F Modular switch one way 6A,1 Module, as per existing make as in repairs complete all as specified and directed by Engr in Charge
S&F Modular switch one way 16A,1 Module, as per existing make as in repairs complete all as specified and directed by Engr in Charge
S&F Modular bell push 6A,1 Module as per existing make as in repairs complete all as specified and directed by Engr in Charge
S&F Modular socket 6/10A-2/3 pin combined 2 as per existing make as in repairs complete all as specified and directed by Engr in Charge
S&F Modular socket 16/15A-2/3 pin combined 2 as per existing make as in repairs complete all as specified and directed by Engr in Charge
S&F Switch piano type 230 volts , 5 Amps, single pole as per existing make as in repairs complete all as specified and directed by Engr in Charge.
S&F Socket out let 2 in 1, 3 pin, 5 Amps flush type 230 volts as per existing make as in repairs complete all as specified and directed by Engr in Charge.
S&F 12 module open pvc box board as per existing make as in repairs complete all as specified and directed by Engr in Charge
S&F Ding dong bell AC 230V as per existing make as in repairs complete all as specified and directed by Engr in Charge
S&F Cord less bell of different music AC 230V as per existing make as in repairs complete all as specified and directed by Engr in Charge
S&F Ceiling rose 3 terminal/ poly carbonate, isolated body complete all as specified and directed by Engr in Charge.
S&F Ceiling rose 3 terminal/ poly carbonate, isolated body as per existing make as in repairs complete all as specified and directed by Engr in Charge
S & F White cover plate with frame , 3 module as per existing make as in repairs complete all as specified and directed by Engr in Charge
S & F White cover plate with frame , 6 module as per existing make as in repairs complete all as specified and directed by Engr in Charge
S & F White cover plate with frame ,8 module as per existing make as in repairs complete all as specified and directed by Engr in Charge
S & F White cover plate with frame ,12 module as per existing make as in repairs complete all as specified and directed by Engr in Charge
S & F White acrylic plate size 8"x6" or 12"x10" as per existing make as in repairs complete all as specified and directed by Engr in Charge
M&L Sub main wiring complete with two run of 6 Sqmm single core, PVC insulated but unsheathed, multistranded copper conductor FRLS 1100 Volts grade cable drawn through in and including non metallic, rigid, PVC heavy duty surface conduit/casing capping (ISI marked) with wall thickness not less than 1.8mm complete with all accessories like bends, tees, junction boxes fixed on wall, ceiling and including sunken type pressed steel terminal boxes with 3mm thick bakelite white/coloured (as approved) top cover including 6 Sqmm single core PVC insulated but unsheathed multistandard copper conductor FRLS 1100 Volts grade cable as earth continuity wire and connected to earth dolly complete as in repairs all as specified. Note :- Two run of 6 Sqmm cable including one run of 6 Sqmm cable for earth continuity cable and PVC conduit and its accessories shall be measured and paid as one length. complete all as specified and directed by Engr in Charge.
M&L Sub main wiring complete with PVC insulated cable two run of 04 Sq mm (FRLS) 1100 volts grade with multi stranded copper conductor for drawn through and including PVC casing capping with accessories including 4 Sq mm unsheathed multi stranded copper conductor as on earth wire complete as in repairs all as specified and directed by Engr in Charge. Note :- Two runs of 4 sqmm cable with one run of 4 sqmm cable for earth continuity cable including PVC casing capping and its accessories shall be measured and paid as one unit
M&L Sub main wiring complete with PVC insulated cable two run of 2.5 Sq mm (FRLS) 1100 volts grade with multi stranded copper conductor for drawn through and including PVC casing -capping with accessories incl 2.5 Sq mm unsheathed multi stranded copper conductor as on earth wire complete as in repairs all as specified and directed by Engr in Charge Note :- Two runs of 2.5 sqmm cable with one run 2.5 sqmm cable for earth continuity cable including PVC casing -capping and its accessories will be measured and paid as one unit
M&L Sub main wiring complete with PVC insulated cable two run of 1.5 Sq mm (FRLS) 1100 volts grade with multi stranded copper conductor for drawn through and including PVC casing -capping with accessories including 1.5 Sq mm unsheathed multi stranded copper conductor as on earth wire complete as in repairs all as specified and directed by Engr in Charge. Note :- Two runs of 1.5 sqmm cable with one run of 1.5 sqmm cable for earth continuity cable including PVC casing -capping and its accessories will be measured and paid as one unit
S&F TPN double door DB 4 way including civil work complete as in repairs all as specified and directed
S&F TPN double door vertical distribution board without MCCB 4 way including civil work complete as in repairs all as specified and directed.
S&F Sheet metal enclosure, single phase, double door DB, flush to wall mounting for MCB fitted with 200 Amp rated bus bars and neutral links (without MCB's) 12 ways SPN complete as in repairs all as specified and directed
S&F Sheet metal enclosure, single phase, double door DB, flush to wall mounting for MCB fitted with 200 Amp rated bus bars and neutral links (without MCB's) 8 ways SPN complete as in repairs all as specified and directed
S&F Sheet metal enclosure, single phase, double door DB, flush to wall mounting for MCB fitted with 200 Amp rated bus bars and neutral links (without MCB's) 4 ways SPN complete as in repairs all as specified and directed
S & F SPN Sheet metal enclosure with a two pin socket plug and socket with one single pole MCB 240Volts, 20 Amps, capacity complete as in repairs all as specified and directed
S&F MCB, TPN 415 volts, 63 Amps capacity complete as in repairs all as specified and directed
S&F MCB, SPN 240 volts, 40 to 63 Amps capacity complete as in repairs all as specified and directed
S&F MCB, SPN 240 volts, 5-32 Amps capacity complete as in repairs all as specified and directed
S& MCB, SP 240 volts capacity 5 - 32 Amps current rating, 10KA breaking capacity complete as in repairs all as specified and directed
S&F Blanking plate as per existing make complete as in repairs all as specified and directed
S&F MCCB 4 Pole 415 V. fixed type,100 Amps with breaking capacity 16 KA complete as in repairs all as specified and directed
S&F MCCB 4 Pole 415 V. fixed type,125 Amps with breaking capacity 16 KA complete as in repairs all as specified and directed
S&F MCCB 4 Pole .415 V. fixed type,160 Amps with breaking capacity 36 KA complete as in repairs all as specified and directed
S& F LED tube light fittings 1x20Watts, 230 volts surface and wall mounted LED type, extruded thermoplastic body with polycarbonate diffuser & integrated electronic driver complete with all accessories internally pre wired and including connection up with twin core twisted flexible copper conductor cable of size 1.5 sqmm and flexible pipe of white colour from ceiling rose to light complete as in repairs all as specified and directed
S&F LED light fittings 1x10Watts, single side connection 230 volts surface and wall mounted LED type complete with all accessories internally pre wired and including connection up with twin core twisted flexible copper conductor cable of size 1.5 sqmm and flexible pipe of white colour from ceiling rose to light complete as in repairs all as specified and directed
S&F Pluto Panel surface/recess mounted 2'x2' ,36/40 watt cool white or warm white in colour LED flat panel for surface mounting which provides soft-light and glare free symmetrical illumination including connection up with twin core twisted flexible copper conductor cable with suitable size complete as in repairs all as specified and directed
S&F Decorative wall mounting/Surface mounted round spot/focus light/mirror light CRCA body powder coated in white of capacity 12 watt complete as in repairs all as specified and directed
S&F LED security light 45 watt ,240 volt IP 65 protection ,weather proof, with all other accessories including all electrical connection complete as in repairs all as specified and directed
Taking down and re fixing after Re-winding in replacement of ceiling/exhaust /wall fan motor of any type and size including removing old burnt wire copper wire as per existing gauge & insulated paper, varnishing also including replacement of bearing, bush and capacitor with cleaning/greasing servicing and connection complete all as specified and directed.
S&F Modular electronic regulator Switch/socket type complete as in repairs all as specified and directed
S&F Exhaust fan 200 mm sweep silent type in PVC Body as required at site including making of holes complete as in repairs all as specified and directed
Taking down of ACs of split type capacity 1.5 /2 TR from the existing site/ locations and taking out filter and servicing the complete in all respect and re fixing the same in original location, and testing complete after installation all as specified and directed. (Note: Contractor has to provide blower and jet pump for cleaning and washing of AC, in this a separate PVC bag will also be provided for collection of waste, mechanic will be responsible to clean the site after servicing)
S &F Foam armor of size 5/8" in repair for AC copper tubing complete all as directed. Make Superlon or equivalent
S&F Foam armor of size 1/4" in repair for AC copper tubing complete all as directed. Make Superlon or equivalent
Taking down and shifting of existing split ACs of capacity 1.5/2 TR and fix in new location including all connection complete all as specified and directed. Note:- Copper pipe shall be measured and paid separately under relevant items.
S&F Starting capacitor suitable for existing split AC of cap 2 TR including all connection complete as in repairs all as specified and directed
S&F Running capacitor suitable for existing split AC of cap 1.5/2 TR including all connection complete as in repairs all as specified and directed
S&F Starting relay suitable for existing split AC of cap 1.5/2 TR including all connection complete as in repairs all as specified and directed
S&F Cooling coil motor suitable for inverter type AC of 1.5/2 TR including all connection complete as in repairs all as specified and directed
Rewinding of blower motor of 2.0 TR split ACs with suitable size of copper wire and refix the same after repair including all electrical connection complete all as specified and directed..
S&F Compressor suitable for existing split type AC 2 TR match with existing ACs including all connection complete as in repairs all as specified and directed
S&F Condenser suitable for existing Split type AC 2 TR match with existing ACs including all connection complete as in repairs all as specified and directed
S&F Condenser fan blade suitable for split AC 2 TR match with existing ACs including all connection complete as in repairs all as specified and directed
S&F Blower bush suitable for split AC of cap 2 TR match with existing ACs including all connection complete all as specified and directed
S&F Blower suitable for split AC of capacity of 2 TR. match with existing ACs including all connection complete as in repairs all as specified and directed
S&F Circuit plate with PCB suitable for split AC of cap 2 TR match with existing ACs including all connection complete as in repairs all as specified and directed
S&F Circuit plate with PCB inverter type of indoor/outdoor AC suitable for split AC of 2 TR match with existing ACs including all connection complete as in repairs all as specified and directed
S&F PVC air filter suitable for existing split AC of 2 TR match with existing ACs including all connection complete as in repairs all as specified and directed
S&F Remote controller suitable for existing split AC of 2 TR including all connection complete as in repairs all as specified and directed
S&F Swing motor suitable for existing split AC of 2 TR match with existing ACs including all connection complete as in repairs all as specified and directed
S&F Condenser motor suitable for existing split AC of 2 TR match with existing ACs including all connection complete as in repairs all as specified and directed
S&F Contactor relay suitable for existing split AC of 2 TR match with existing ACs including all connection complete as in repairs all as specified and directed
S&F Copper tube of 16 sq mm bore including all connection complete as in repairs all as specified and directed
S&F Copper tube of 12.7 sq mm bore including all connection complete as in repairs all as specified and directed
S&F Copper tube of 9.5 sq mm bore including all connection complete as in repairs all as specified and directed
S&F Copper tube of 6.3 sq mm bore including all connection complete as in repairs all as specified and directed
S&F Drain pipe PVC, 3 mtr in length, suitable for split AC of cap 1.5 /2 TR including all connection complete as in repairs all as specified and directed
S&F Bracket suitable for fixing of outdoor unit of existing split AC of cap 1.5/2 TR including all connection complete as in repairs all as specified and directed
S &F Brass valve1/4" suitable for existing split AC of cap 1.5/2 TR including all connection complete as in repairs all as specified and directed
S &F Brass valve1/2" suitable for existing split AC of cap 1.5/2 TR including all connection complete as in repairs all as specified and directed
S&F Brass valve 5/8" suitable for existing split AC of cap 1.5/2 TR including all connection complete as in repairs all as specified and directed
Supply & Filling gas Freon (R22/R32/R410A) or suitable for existing system. Note:- (i) Gas bottle to be arranged by contractor. (ii) Labour charges deemed included in item No 51 above.
S&F Cable three core flexible twisted copper conductor of 2.5 sq mm incuding all connection complete all as specified and directed.
S&F Capacitor 4 Mfd + 5% 440V MPP 'SH' match with existing incuding all connection complete as in repairs all as specified and directed
S&F PVC conduit pipe suitable for 3 core 1.5 Sqmm/2.5 Sqmm wire including all fittings for fixing at site complete as in repairs all as specified and directed
S&F 3 pin 15 A top including all connection complete as in repairs all as specified and directed
S&F Casing capping patti suitable for 3 core/1.5 Sqmm/2.5 Sqmm wire including all connection complete as in repairs all as specified and directed
S&F AC plug top metal type suitable for existing ac of capacity 1.5/2 TR including all connection complete as in repairs all as specified and directed
S&F Non-Return Valave of size 15/20 mm dia including all connection complete as in repairs all as specified and directed
S&F Non-adhesive tape roll for copper tubing of AC complete as in repairs all as specified and directed
M&L AC water leakage, removing of drain tray cleaning of tray clear all blockage, and refixing the same and make proper insulation and testing including all connection complete as in repairs all as specified and directed
S&F Capacitor 2.5 Mfd + 5% 440V MPP 'SH' including all connection complete as in repairs all as specified and directed
S&F Capacitor 6 Mfd + 5% 440V MPP 'SH' including all connection complete as in repairs all as specified and directed
S&F Line reactor (VFD) suitable for inverter type existing split AC of cap 1.5/2 TR including all connection complete as in repairs all as specified and directed
S&F Contact sensor (indoor/outdoor/gas/temperature) suitable for existing split AC inverter type or non-inverter tpe of cap 1.5/2 TR including all connection complete as in repairs all as specified and directed
M&L Repairs to burnt out indoor unit of split type AC carefully removing connection of old unit and fix indoor unit of same capacity & make including proper connection complete as in repairs all as specified and as directed
M&L Repairs to AC indoor cooling coil removing carefully of coil cleaning of coil clear all blockage fill nitrogen gas pressure for leakage testing ,close the leakage by welding and refixing the same and make proper insulation and testing complete as in repairs all as specified and directed
M&L Dry servicing of ACs of split type or window type capacity 1.5 /2 tr from the existing site and taking out filter and dry servicing the complete in all respect and fixing the same in original location, and testing complete. (Note: Contractor shall provide blower without any extra cost , Mechanic will be responsible to clean the site after servicing)
M & L Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried in ground (earth pit not less than 2.25 Mtr deep below normal ground level with top edge of the plate not less than 1.5 Mtrs below normal ground level, connecting to galvanized iron earth strip 25x4 mm as earthing lead by means of bolt ,nuts, check nuts and washer of galvanized iron or steel besides welding of all joints as shown in drawing and including excavation and earthwork and earth lead protection by provision of GI light grade pipe 32 mm bore including provision of concrete pit in PCC (1:2:4) type B1 using 20mm graded stone aggregate with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4gs/Sqm) and frame of angle iron 25mm x 25mm x 6mm with lugs 02 Nos and with 6 mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at the bottom 1.75 meter long placed on top edge of earth plate common salt and charcoal filling test point made out of 40mm x 8 mm FI with fixing arrangements, funnel, wire mesh and earth work in hard dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 Mtrs all as per electrical Plate No.3 of SSR Part I and connecting to earth test point all as specified or indicated including testing on completion Note: (i) Item includes the cost of 7.5 metre length GI pipe for protection of earth lead and earth lead . (ii) Earth resistance of earth pit should be less than 0.5 Ohms. On testing after completion if the desired earth resistance in not obtained the earthing will be redone at no extra cost
S &F On load type Change Over Switch of capacity 125 Amps, four pole 415 volts,50 Hz,AC in open execution complete with handle assembly having door interlock arrangement including all connection complete all as specified and directed.
S &F On load type Change Over Switch of capacity 200 Amps, four pole 415 volts,50 Hz,AC in open execution complete with handle assembly having door interlock arrangement including all connection complete all as specified and directed.
Excavation in trenches n.exc 1.5 m wide and n. exc. 1.5 m in depth for laying of electric cables for fixing of poles and stay or for laying pipes (where provided for protection of cables) and getting out trimming the sides forming bottom surface to required level in soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n. exc 25 cm in soft/loose soil complete all as specified and directed.
Removal of surplus soil to a distance n. exc 50 m and depositing where directed at a level n. exc 1.5 m above the starting point complete all as specified and directed
M & L Dry Sand cushioning to underground cable with screened, washed river sand, including punning gently all as specified and directed. Note: - Thickness after punning will be measured for payment.
Supply and lay burnt brick sub class `B' old size in trenches abutting each other width equal to length of brick etc complete all as specified and directed
Supply and laying in trenches in road cross / floors tube galvanised iron pipe of 40 mm bore light grade with all fittings for protection of cable all as specified.
Supply and laying of LT UG cable, XLPE insulated screened PVC bradded (ISI Marked), galvanized steel strip or wire , electric power cable (heavy duty) 1100 volt grade with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as specified and directed
Supply and laying of LT UG cable, XLPE insulated screened PVC bradded (ISI Marked), galvanized steel strip or wire , electric power cable (heavy duty) 1100 volt grade with stranded aluminium conductor of size 50 sq mm 3.5 core complete all as specified and directed
Supply and laying of LT UG cable, XLPE insulated screened PVC bradded (ISI Marked), galvanized steel strip or wire , electric power cable (heavy duty) 1100 volt grade with stranded aluminium conductor of size 35 sq mm 3.5 core complete all as specified and directed
Supply and laying of LT UG cable, XLPE insulated screened PVC bradded (ISI Marked), galvanized steel strip or wire , electric power cable (heavy duty) 1100 volt grade with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified and directed
Supply and laying of LT UG cable, XLPE insulated screened PVC bradded (ISI Marked), galvanized steel strip or wire , electric power cable (heavy duty) 1100 volt grade with stranded aluminium conductor of size 10 sq mm 2 core complete all as specified and directed
Supply and laying 50mm bore GI tubing medium grade including GI fittings like sockets, elbows, bends, Tees, unions, short pieces etc. laid in trench/on wall complete all as specified
Supply and laying 40mm bore GI tubing medium grade including GI fittings like sockets, elbows, bends, Tees, unions, short pieces etc. laid in trench/on wall complete all as specified
Supply and laying 25mm bore GI tubing medium grade including GI fittings like sockets, elbows, bends, Tees, unions, short pieces etc. laid in trench/on wall complete all as specified
S&F 50mm bore Gun metal gate/globe valve heavy duty (ISI marked) with iron wheel head screwed both ends for iron pipe including testing complete as in repairs all as specified
S&F 40mm bore Gun metal gate/globe valve heavy duty (ISI marked) with iron wheel head screwed both ends for iron pipe including testing complete as in repairs all as specified
S&F 25mm bore Gun metal gate/globe valve heavy duty (ISI marked) with iron wheel head screwed both ends for iron pipe including testing complete as in repairs all as specified
Taking down of RO of any type/capacity from the existing site/locations and taking out filter and servicing the complete in all respect and fixing the same in original location, and testing complete after installation all as specified and directed.
Notes for all items covered under BOQ, 1. Contractor shall provide experienced electrician of electrical works and technician for AC & other works including suitable helpers on daily basis to finish complaints. 2. Complaints noticed by user/ MES authority shall attend within 24 hrs otherwise penalty of Rs 500 per day complaint will be recovered from the contractor 3. Tools and plants required for the competition of entire work shall be provided as per requirement by the contractor without any extra cost to department
SHIV SHANKAR MISHRA (BID ID -3042509)
Harsh Infrastructure (BID ID -3041854)
SNEH TRADERS (BID ID -3041534)
Nitesh Enterprise (BID ID -3042307)
SHOBHIT BUILDERS (BID ID -3039665)
Shree Builders (BID ID -3041585)
K K Construction Co (BID ID -3039874)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .