GE Palampur
Holta Camp Palampur Kangra (H.P) 176061
OUTSOURCING OF SERVICES FOR MAINTENANCE AND OPERATION OF CENTRAL AIR CONDITIONING PLANT AND REPAIR AND MAINTENANCE OF SPLIT/WINDOW ACS CENTRAL AC PLANT COOLING/HEATING APPLIANCES REFRIGERATORS AND MISC WORK AT PALAMPUR MIL STN
2020_MES_374284_1
GEP- /2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Palampur
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
GE Palampur
₹35,000
Yes
14 Oct 2020
3 Sept 2020
12 Sept 2020
3 Sept 2020
10 Sept 2020
4 Sept 2020
Amount
SCHEDULE 'A' PART-I:- Outsourcing of services for maintenance and operation of central air conditioning plant and standby DG Set of capacity 250 KVA installed at Signal Centre at Palampur Mil Stn by engaging 01 Refrigeration mechnic or AC tradesmen (ITI qualified) each shift at Palampur Military Station for shift of 8 hours for three shift in a day including Sundays and holidays all as directed. .
Outsourcing of services for maintenance and operation of Central Air Conditioning Plant installed at Signal Centre by engaging 01 Helper for tradesmen at Palampur Military Station in one shift of 8 hours in a day and to assist tradesmen engaged for maintenance and operation of AC Plant at Srl No. 1 above in Maint and Operation of DG Set of capacity 250 KVA for Signal Centre 24x7 including topping up of Fuel and oil in the DG Set including Sundays & holidays all as directed Note for Item No 01 to 02:- (i) Inside, surrounding area of the Central AC Palnt Installations and all equipments shall be maintained neat and clean all the time and the unit rate quoted shall be deemed to incl the cost of the same. (ii) The skilled tradesmen shall be ITI certificate holder & capable to attend emergency repair/ maintenance and complaints as per the directions of Engr-in-charge. (iii) All T&P required for attending complaints and maintenance of plant and installation will be supplied by the contractor and cost is incl in the rate quoted. (iv) Proper attendance register shall be maintained by the contractor. (v) The Tradesmen shall be provided with protective clothings/safety hand gloves/industrial helmets/ safety belts/ face masks/rain coat and shall bear that while on duty and the cost is incl in the rate quoted.
(vi) The contractor has to provide adequate means to the workmen for conducive work environment and he has to ensure that the workers are covered as per labour law and insurance act. All the tradesmen should be covered under Insurance act vide Indian Electricity Rules, 1956. (vii) The unit rate quoted is deemed to include for printing log sheet, registers and other stationery items. (viii) The contractor shall be provided with approved colour of uniform for the tradesmen. The rate quoted deemed to be included in the quoted rate. (ix) The following register/documents to be maintained on daily basis. :- (a) Plant Running Record book. (b) Daily Log sheet for Central AC Palnt. (x) In case the contractor fails to depute person in shift as asked, then suitable recovery shall be made for the same. Panel reovery @ Rs 600/- per shift shall be recovered in case of operator / technician / helper found absent from duty. (xi) The contractor will provide two sets of complete tools and one commando torch, tool bag which will be used by the technicians and Helpers while on duty at the installtions. The tools will be returned to the contractor on completion of the contract. The rates for the same are deemed to be included in the rates quoted. In case of non provision of tools Rs. 20000.00 will be recovered will be recovered from the contractor due amount. (xii) The contractor has to ensure all COVID-19 precautions with preventive materials. The cost of preventive materials shall be included in the qouted rates. Note : All items are required for maintenance shall be paid to contractor as supply only
SCHEDULE 'A' PART-II:- Supplying and re-charging of refrigerant Gas R-22 / R-410 in AC plant after detection of leakage & rectification of same in the system by using Carbon Di-oxide Gas and flushing the complete system thoroughly with Nitrogen gas, complete all as specified and directed by Engr-in-charge. Note:- (i) Gas shall be brought by the contractor at Site from authorized Dealer/Manufacturers in sealed cylinders of standard packings and re-filling shall be done in the presence of rep of Deptt. The empty cylinders after using the gas brought shall be returned to the contractor for payment purpose, only gas to the required extent used for charging shall be considered. (ii) The unit rate inserted is being to be inclusive of the cost of nitrogen gas used for leakage test and pressure test prior to filling/ charging of gas R-22 / R-410
Supply only compressor oil (Non-freezing) in AC plant, complete all as specified and directed by Engr-in-charge. Make:- SHEETAL/ CALTEX/ ZED PLUS NOTE:- Compressor oil shall be brought by the contractor in sealed barrels.
Descaling the condenser by recommended chemical cleaning agent by soaking method, disconnection condenser from the system by taking out nuts bolts, studs 2 Nos valves and MS/GI pipe line form both sides cover, cleaning each tube with nylon brush, flushing with alkaline solution connecting back both side cover including replacing leather gasket 4mm thick for following capacities of condensers suitable for AC plant capacities installed as indicated below, complete all as specified and directed.
Dismantling of worn out part of FRP cooling tower of capacity 60 TR, cleaning of water tanks and body of cooling tower to make the cooling tower functional and serviceable in all respect including rectification of minor leakages from the cooling tower with M Seal adhesive, complete all as specified and directed.
Supply only side cover jalli for cooling tower for capacity 60 TR in replacement as per existing size and pattern, complete all as specified and directed.
Supply only PVC fins honeycomb of size 24"x12"x6" for cooling tower of capacity 60 TR, complete all as specified and directed.
Supply only replacement gun metal thermal expansion valve of capacity 60 TR, complete all as specified and directed.
Taking out unserviceable wiring of panel/control system of AC Plant micro processor panel , rewiring the same with new suitable capacity of copper conductor PV insulated wire and making connection to make the control/ interlocking system functional, complete all as specified and directed.
Supply only top protector cover to the CT fan motor at the top of the cooling tower made of GI sheet 20 SWG, conical shape including flat iron of required size complete to protect the CT fan motor form rain water, complete all as specified and directed.
Supply only metallic viscose filter in replacement made out of GI wire mesh interspaced with two crimp layers and three flat layers and housed in 2" deep metal frame efficiency 65% as per existing size and pattern for AC Plant air handling unit at signal centre complex, complete all as specified and directed.
Supply only water pressure gauge 100 mm dia range 0-100 Lbs/Sq inch , complete all as specified and directed.
Supply only suction pressure gauge suitable for range (-) 30 to 150 Lbs/Sq inch, complete all as specified and directed.
Supply only discharge pressure gauge suitable for range 0-300 Lbs/Sq inch, complete all as specified and directed.
Supply only air grills made out of GI sheet as per existing size and pattern complete with necessary nuts, bolts, clamps and MS frame made out of angle iron of required size damper for opening and closing of grills, complete all as specified and directed.
Supply only Cast iron butterfly valve of size 150 mm dia (ISI Mark) complete all as specified and directed.
Supply only Cast iron butterfly valve of size 100 mm dia (ISI Mark), complete all as specified and directed.
Supply only cast iron butterfly valve of size 80 mm dia (ISI Mark), complete all as specified and directed.
Supply only cast iron balancing valve of size 80 mm dia (ISI Mark), complete all as specified and directed.
Supply only cast iron 'Y' Strainer of size 80 mm dia (ISI Mark) complete all as specified and directed.
Supply only bearing set (set of Bearings) (ISI Mark) for AC Plant of capacity 60 TR, complete all as specified and directed.
Supply only gasket set for AC Plant, complete all as specified and directed.
Supply only filter for AC Plant, complete all as specified and directed.
Supply only power contactor of rating 25 amp 4 pole complete all as specified and directed.
Material and labour in replacement of unserviceable hermitically sealed compressor of refrigerator 310/280 litres capacity with fresh new uncut sealed compressor including suitable relay and over load with new sealed unit as per the company scheme supplied by the manufacturer complete including flushing out system, checking and rectification of leakage, gas charging, complete and testing after completion of work at MES Store yard for satisfactory function. Note:- (i) The rate quoted by the contractor shall be inclusive of all charges like transportation, fitting etc complete with necessary guarantee period as per company terms and conditions. (ii) The new unit will be purchased from authorized dealer.
Material and labour in replacement of unserviceable hermitically sealed compressor of refrigerator 165/170/180 litres capacity with fresh new uncut sealed compressor including suitable relay and over load with new sealed unit as per the company scheme supplied by the manufacturer complete including flushing out system, checking and rectification of leakage, gas charging, complete and testing after completion of work at MES Store yard for satisfactory function. Note:- (i) The rate quoted by the contractor shall be inclusive of all charges like transportation, fitting etc complete with necessary guarantee period as per company terms and conditions. (ii) The new unit will be purchased from authorized dealer.
S&F in repairs relay suitable for 286/310 litres capacity refrigerator. Make:- Renutrol/Shriram/Anpurna/klixon
S&F in repairs relay suitable for 165 litres capacity.refrigerator. Make:- Renutrol/Shriram/Anpurna/klixon
S&F in repairs thermostat automatic `R' frost with knob suitable for 165/286/310 litres capacity refrigerator. Make :-Anpurna/Indofos
S&F in repairs freezer assembly (including gas charging ) complete with screw, jointing of tubes etc. and testing of capacity 286/310 litres refrigerator of any make.
S&F in repairs freezer assembly (including gas charging ) complete with screw, jointing of tubes etc. and testing of capacity 165/175 litres refrigerator of any make.
S&F in repairs condensor unit of refrigerator capacity 286/310 litres of any make including jointing of tubes and testing etc. complete. Note:-Gas charging will be measure and paid under relevant item separately.
S&F in repairs condensor unit of refrigerator capacity 165 litres of any make including jointing of tubes and testing etc. complete. Note:-Gas charging will be measure and paid under relevant item separately.
Material and labour, flushing out system , checking and rectification of leakages if any and make it serviceable incl. gas charging with refrigerant R-12/R-135 A , oil charging complete in refrigerator of capacity 286/310 litres complete all as directed & with entire satisfaction of Engineer-in-Charge.
Material and labour, flushing out system , checking and rectification of leakages if any and make it serviceable including gas charging with refrigerant R-12/R-135 A, oil charging complete in refrigerator of capacity 165/180 litres complete all as directed & with entire satisfaction of Engineer-in-Charge.
Material and labour in replacement of unserviceable cut sealed compressor of window type/split type ACs 1.5 TR capacity with new uncut sealed hermetically compressor unit supplied by the manufacturer complete unit including wiring as required to unit with flushing out system checking and rectification of leakage, gas charging complete and testing after completion of work at MES store yard for satisfactory functioning NOTE:- (i) The rate quoted by the contractor shall be inclusive of all charges like transportation, fitting etc complete with necessary guarantee period as per company terms & conditions. (ii) The new compressor unit will be purchased from authorized dealers only as per existing make and model
Material and labour in replacement of unserviceable cut sealed compressor of window type/split type ACs 2.00 TR capacity with new uncut sealed hermetically compressor unit supplied by the manufacturer complete unit including wiring as required to unit with flushing out system checking and rectification of leakage, gas charging complete and testing after completion of work at MES store yard for satisfactory functioning NOTE:- (i) The rate quoted by the contractor shall be inclusive of all charges like transportation, fitting etc complete with necessary guarantee period as per company terms & conditions. (ii) The new compressor unit will be purchased from authorized dealers only as per existing make and model
S&F in repairs condensor fan motor of Speed 900 RPM of window/Split Air conditioner of cap. 1/5HP
Material and labour, flushing out system , checking and rectification of leakages if any and make it serviceable incl. gas charging with refrigerant R-22/R-410 A, oil charging complete in compressor window type AC/ Split type AC cap.1.5 Ton all as directed & with entire satisfaction of Engineer-in-Charge.
Material and labour, flushing out system, checking and rectification of leakages if any and make it serviceable incl. gas charging with refrigerant R-22/R-410 A, oil charging complete in compressor window type AC/ Split type AC capacity 2.00 Ton all as directed & with entire satisfaction of Engineer-in-Charge.
Material and labour for taking out window type AC from site of any cap.and make for servicing including cleaning with air blower , cleaning and washing fins of cooling coil with caustic soda mixed water, taking out all dirt , sludge deposited, cleaning of air filter incl. oiling / greasing of condensing fan motor , spray painting of outer cover with 2 coats of synthetic enameled paint of approved colour as directed with writing of serial No SM/MES No. and reinstalled the AC in position with fixing of putty etc. complete all as directed by EIC. Note:- Change the defective parts of AC like condensar fan motor, fan balt, blower etc, if change during servicing then same shall be paid as supply only.
Material and labour for servicing /overhauling of split type AC unit capacity 1.5 Ton including painting to outer cover and components with two coats of synthetic enameled paintof colour as directed) complete including following:- (a) Cleaning and descaling of condensing unit and cooling coil with caustic soda mixed water and air blower and taking out all dirt /sludge etc. all as directed by EIC. (b) Greasing / oiling of blower fan motor. (c) Charging the gas as required to full fill the rated cooling effect. (d) Change the defective parts of AC like condensar fan motor, fan balt, blower etc, if change during servicing then same shall be paid as supply only.
Material and labour for servicing /overhauling of split type AC unit capacity 2.00 Ton including painting to outer cover and components with two coats of synthetic enameled paintof colour as directed) complete including following:- (a) Cleaning and descaling of condensing unit and cooling coil with caustic soda mixed water and air blower and taking out all dirt /sludge etc. all as directed by EIC. (b) Greasing / oiling of blower fan motor. (c) Charging the gas as required to full fill the rated cooling effect. (d) Change the defective parts of AC like condensar fan motor, fan balt, blower etc, if change during servicing then same shall be paid as supply only.
S&F in repairs blade of condensing fan motor (as per sample) for window type AC cap 1.5 Ton. (any make)
Supply only running capacitor clip type of cap. 36 MFD, 240 volts 50 cycles for window type/Split type air conditioner 1.5 Ton capacity. Make:- Escop/Kell/Tesla/Sharda
S&F in repairs running capacitor clip type of cap. 36 MFD, 240 volts 50 cycles for window type/Split type air conditioner 1.5 Ton capacity. Make:- Escop/Kell/Tesla/Sharda
Supply only starting capacitor clip type of cap. 80-100 MFD,440 volts 50 Hz for window type /Split type air conditioner. Make:- Kell/Tesla/Sharda/Epcos
S&F in repairs starting capacitor clip type of cap. 80-100 MFD,440 volts 50 Hz for window type /Split type air conditioner. Make:- Kell/Tesla/Sharda/Epcos
Supply only running capacitor clip type of cap. 45 MFD, 240 volts 50 cycles for window type air conditioner 2 Ton Capacity. Make:- Epcos/Kell/Tesla/Sharda
S&F in repairs running capacitor clip type of cap. 45 MFD, 240 volts 50 cycles for window type air conditioner 2 Ton Capacity. Make:- Epcos/Kell/Tesla/Sharda
Supply only starting capacitor clip type of cap. 100-120 MFD,440 volts 50 Hz for window type/split type air conditioner. Make:- Kell/Tesla/Sharda/Epcos
S&F in repairs starting capacitor clip type of cap. 100-120 MFD,440 volts 50 Hz for window type/split type air conditioner. Make:- Kell/Tesla/Sharda/Epcos
Supply only capacitor 4 Mfd in split type AC complete all as specified and directed.
S&F in repairs capacitor 4 Mfd in split type AC complete all as specified and directed.
Supply only connector unit in split type AC complete all as specified and directed.
S&F in repairs connector unit in split type AC complete all as specified and directed.
Supply only blade for condensing fan motor in split type AC complete all as specified and directed.
S&F in repairs blade for condensing fan motor in split type AC complete all as specified and directed.
Supply only capacitor 6 MFD in split type AC complete all as specified and directed. Make: Epcos/texla
S&F in repairs capacitor 6 MFD in split type AC complete all as specified and directed. Make: Epcos/texla
Supply only capacitor 2.5 MFD in split type AC complete all as specified and directed. Make:Epcos/texla
S&F in repairs capacitor 2.5 MFD in split type AC complete all as specified and directed. Make:Epcos/texla
Supply only foam type insulating flexible pipe fitted on suction /discharge copper tubes in split type AC complete all as specified and directed.
S&F in repairs foam type insulating flexible pipe fitted on suction /discharge copper tubes in split type AC complete all as specified and directed.
Supply only PCB Card for split type AC of capacity 1.5 TR in split type AC complete all as specified and directed.
S&F in repairs PCB Card for split type AC of capacity 1.5 TR in split type AC complete all as specified and directed.
Supply only PCB Card for split type AC of capacity 2 TR in split type AC complete all as specified and directed.
S&F in repairs PCB Card for split type AC of capacity 2 TR in split type AC complete all as specified and directed.
Supply only remote hand set for split type AC 1.5/2 TR capacity in split type AC complete all as specified and directed.
Supply only valve 1/2 ", 1/4 " and 5/8 " for split type of capacity 1.5 TR in split type AC complete all as specified and directed.
S&F in repairs valve 1/2 ", 1/4 " and 5/8 " for split type of capacity 1.5 TR in split type AC complete all as specified and directed.
Supply only condensor unit of split type of capacity 1.5/2 TR in split type AC complete all as specified and directed.
S&F in repairs condensor unit of split type of capacity 1.5/2 TR in split type AC complete all as specified and directed.
Supply only blower motor of indoor unit of split type of cap 1.5 /2 TR as per existing make/model
S&F in repairs blower motor of indoor unit of split type of cap 1.5 /2 TR as per existing make/model
Supply only copper pipe of size 1/4 " from outdoor unit to indoor unit including soldering and brazing complete
S&F in repairs copper pipe of size 1/4 " from outdoor unit to indoor unit including soldering and brazing complete
Supply only copper pipe of size 1/2 " from outdoor unit to indoor unit including soldering and brazing complete
S&F in repairs copper pipe of size 1/2 " from outdoor unit to indoor unit including soldering and brazing complete
Supply only copper pipe of size 5/8 " from outdoor unit to indoor unit including soldering and brazing complete
S&F in repairs copper pipe of size 5/8 " from outdoor unit to indoor unit including soldering and brazing complete
Supply only heating assy for Air Conditioner capacity 1.5/ 2T complete all as specified and directed.
S&F in repairs heating assy for Air Conditioner capacity 1.5/ 2T complete all as specified and directed.
Supply only Air Filter for Air Conditioner of capacity 1.5/ 2T complete all as specified and directed.
S&F in repairs Air Filter for Air Conditioner of capacity 1.5/ 2T complete all as specified and directed.
Supply and fixing in repairs sheet metal enclosures with socket, plug top and MCBs single pole and neutral enclosures with a two pin and earth plug and socket complete with one single pole MCB 32 Amps 240 Volts complete all as specified and directed.
Supply only thermostat switch suitable for 2 ton /1.5 ton capacity air Conditioner complete all as specified and directed.
S&F in repairs thermostat switch suitable for 2 ton /1.5 ton capacity air Conditioner complete all as specified and directed.
Supply only relay suitable for 2 ton/1.5 ton capacity Air Conditioner as per sample complete all as specified & directed.
S&F in repairs relay suitable for 2 ton/1.5 ton capacity Air Conditioner as per sample complete all as specified & directed.
Repair to unserviceable/burnt stablizer of 1 KVA to 2 KVA capacity complete including replacement of knobs, rewinding of burnt transformer etc complete all as specified and directed. Note : The other item like time delay relay, over load relay etc shall be measured and paid seprately as supply only.
Repair to unserviceable/burnt stablizer of 3 KVA to 5 KVA capacity complete including replacement of knobs, rewinding of burnt transformer etc complete all as specified and directed. Note : The other item like time delay relay, over load relay etc shall be measured and paid seprately as supply only.
Supply only time delay relay 500 volts complete all as specified and directed.
Supply only over load relay 25-40 Amp complete all as specified and directed.
Disconnecting electric connection of centrifugal pump set, 10 HP, electric dirven, three phase, 415 volts, and taking out from AC Plant transporting the same to work shop, dismentaling the pump set, re-winding the motor with suitable size of cooper enamalled wire, change the bearings , change of shaft if required, change the impalar if required etc, re-assembling the same transport from work shop to site, re-fixing in same position, making etecric connection and testing complete all as specified and directed. Note:- All defective parts deemed to be included in repair cost.
Disconnecting electric connection of monoblock pump set, 5 HP, electric dirven, three phase, 415 volts, and taking out from AC Plant transporting the same to work shop, dismentaling the pump set, re-winding the motor with suitable size of cooper enamalled wire, change the bearings , change of shaft if required, change the impalar if required etc, re-assembling the same transport from work shop to site, re-fixing in same position, making etecric connection and testing complete all as specified and directed. Note:- All defective parts deemed to be included in repair cost.
satpal and brothers
M/s Pankaj Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .