| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹7.5 LAccepted-AOC | ₹7.5 L | 1 | Accepted-AOC Lowest |
| 2 | 2₹7.6 L+₹7,047 (0.94%)Rejected-AOC | ₹7.6 L+₹7,047 (0.94%) | 2 | Rejected-AOC Highest |
Tender Value
Refer Docs
EMD Value
₹19,362
Closing Date
26 Mar 2025, 11:00 amClosed
ASSISTANT EXECUTIVE ENGINEER
PWD MECHANICAL SUB DIVISION PMG THIRUVANANTHAPURAM
DEPOSIT-Mechanical Works-Design, Supply, Installation, Testing and Commissioning of 5 KLD Packaged Laundry Effluent Treatment Plant at Taluk Head Quarters Hospital, Parassala.-General Mechanical Work
2025_Irrig_743905_1
IRR/MH/TR/4193/2024_16_1_1/1
Open Tender
Civil Works - Water Works
Item Rate
Parassala
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,710
₹19,362
4 Jun 2025
28 Feb 2025
29 Mar 2025
28 Feb 2025
26 Mar 2025
28 Feb 2025
Amount
Earth excavation
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
2.36:Extra for levelling & neatly dressing of disposed soil completely as directed by Engineer-in-charge.
2.1.1:Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m and lift up to 1.5 m, disposed soil to be levelled and neatly dressed:All Kinds of soil
Foundation Works
2.27:Supplying and filling in plinth with Jamuna sand under floors, including watering, ramming consolidating and dressing complete.
4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
RCC Works
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
Mechanical, Plumbing, Electrical and Civil Works
OD12009/2024-2025:Providing suitable SS Screen Bar (Grade SS 304) for prevent the contaminant particles like cloths, etc.; MS Frame Cover (platform over the Chamber) for easily removing the contaminant particles; 110 mm dia. UPVC Pipes with accessories for transferring the Effluent Water from Power Laundry unit; etc.; to the RCC Screen Chamber (Inner Size: length-1.5 m x width 0.5 m x depth 1 m) and complete the works neatly as per the directions of Departmental Officers at site.
OD12165/2024-2025:Provide Raw Effluent Transfer Pump and its accessories; UPVC Pipes with connections suitable for inlet and outlet of the Pump Set and in of the EWCT; Filtering Equipment’s; Leak Proof Coating Materials; etc.; to the RCC Effluent Water Collection Tank (Inner Size: length - 2.5 m x width - 2 m x depth – 1.5 m) and complete the works neatly as per the directions of Departmental Officers at site. The Raw Effluent Transfer Pump must be in minimum 1 HP with self-priming and flow rate minimum 1m3/hr. @ 10 m head. And also supply the suitable electrical accessories and install it neatly as per the directions of Departmental Officers at site.
OD12262/2024-2025:Provide the good quality FRP Tank for used as Settling Tank with accessories like Water Filtration System, Alum, etc; Poly Dosing System with Tanks (material: HDPE); Dosing Pumps with accessories; Agitator (SS Materials) with Gear Box and Motor; UPVC Pipes suitable for inlet and outlet connections of the Settling Tank and Pumps: Electrical accessories; etc. and making the Settling Tank neatly as per the directions of Departmental Officers at site.
OD12274/2024-2025:Supply the accessories suitable for Clarifier Tank like Pump Set and electrical connections; UPVC Pipes suitable for inlet and outlet connections of the Clarifier Tank & Pump Set; Dosing Tanks, Pumps & Dosing materials; etc. and making the Clarifier Tank neatly as per the directions of Departmental Officers at site.
OD12380/2024-2025:Supply the accessories suitable for making Pressure Sand Filter Tank (Material: FRP) including filter media like Graded Sand, Gravel, Pebbles, etc.; UPVC Pipes suitable for inlet and outlet connections of the PSF Tank; Pressure Pump Set with Electrical accessories and Gauges, Valves. etc. and making the required PSF Tank suitable for 5KLD ETP neatly as per the directions of Departmental Officers at site.
OD12381/2024-2025:Supply the accessories suitable for making Activated Carbon Filter Tank (Material: FRP) including filter media Activated Carbon, Supporting Media, etc.; UPVC Pipes suitable for inlet and outlet connections of the ACF Tank; Pressure Pump Set with Electrical accessories and Gauges, Valves. etc. and making the required ACF Tank suitable for 5KLD ETP neatly as per the directions of Departmental Officers at site.
OD12389/2024-2025:Supply the materials like Water Pump and its accessories, UPVC Pipes suitable for inlet and outlet connections of pump set and in of the Treated Water Collection Tank, Electrical accessories, etc. for finishing the TWCT. It is making with suitable accessories neatly as per the directions of Departmental Officers at site. The Treated Water Pump must be in minimum 1 HP with self-priming and flow rate minimum 1m3/hr. @ 10 m head. And also supply the suitable electrical accessories, Flow meter for measuring discharge of water and install the items neatly as per the directions of Departmental Officers at site.
OD12456/2024-2025:Supply the materials like Sludge Transfer Pump and its accessories; UPVC Pipes suitable for inlet and outlet connections of pump set and Sludge Drying Bed; Electrical accessories, etc. for finishing the SDB. Sludge Drying Bed is making with suitable accessories including filtering media neatly as per the directions of Departmental Officers at site. The Sludge Transfer Pump must be in minimum 1 HP with self-priming, Non-clog, Centrifugal Pump and flow rate minimum 1m3/hr @ 10 m head. And also supply the suitable electrical accessories and install it neatly as per the directions of Departmental Officers at site.
OD12469/2024-2025:Supply the materials other specified items like Air Blower, Electrical Panel Board, Cables, Ducts, Earthling Cables, ELCB’s, etc. as per the directions of Departmental Officers at site and neatly install it.
OD12476/2024-2025:Supply the 1000 Liter FRP Water Tank for collecting treated water with materials like Floating Valve; UPVC Pipes suitable for inlet and outlet connections of pump set and Water Tank; Electrical accessories, etc. as per the directions of Departmental Officers at site and neatly install it. The Water Pump must be in minimum 0.5 HP with self-priming, Pump and flow rate minimum 1m3/hr @ 10 m head.
OD12492/2024-2025:Supply the materials for Plastering and Leak Proof Works of Slabs used in under ground RCC Tanks (Overall size: - 4.45m x 3.95 m x 0.15 m)
OD12500/2024-2025:Supply the MS materials and making the suitable man hole to the underground RCC tanks for cleaning purpose as per the directions of Departmental Officers at site (length 90cm x breadth 90cm)
OD12487/2024-2025:Provide Design of 5 KLD Effluent Treatment Plant uses for Parassala Government Taluk Head Quarters Hospital and Finish the jobs like Site Cleaning, Testing, Trial Run and Commissioning the system neatly as per the directions of Departmental Officers at site and get necessary approvals or certificates, etc. for the entire system.
Dinesh Kumar R (BID ID -2169360)
Bidder Name
Dinesh Kumar R
BINIL S O
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .