| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.8 CrAdmitted-Finance | ₹11.8 Cr | L1 | Admitted-Finance |
| 2 | L2₹13.3 CrAdmitted-Finance | ₹13.3 Cr | L2 | Admitted-Finance |
| 3 | L3₹15.0 CrAdmitted-Finance | ₹15.0 Cr | L3 | Admitted-Finance |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Others-As per summary sheet enclosed |
| 5 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Others-As per summary sheet enclosed |
| Sl No | Description | Qty | Unit | KAPAHI CONSTRUCTION COMPANY L1 | KAPAHI CONTRACTS PRIVATE LIMITED L3 | Sanjiv Kumar Sharma L2 |
|---|---|---|---|---|---|---|
| 1.00 | Earth work in excavation by mechanical means(Hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 mtr in width as well as 10 sqm on plan) in all kinds of soil including rock and disposal of surplus, excavated earth at dumping sites to be purchased by the contractor and approved by the engineer-in-charge at site for safe disposal of same without damaging private /public property and all required leads/lifts and carriage.(Complete job) | 6,200 | cum | 252 ₹15.6 L | 399 ₹24.7 L | 300 ₹18.6 L |
| 2.00 | Providing and laying in position Cement concrete of specified grade excluding the cost of centering and shuttering–all work upto plinth level 1:5:10 (1 cement : 5 coarse sand : 10 graded crushed stone aggregate 40 mm nominal size) | 190 | CUM | 1,000 ₹1.9 L | 3,500 ₹6.7 L | 4,500 ₹8.6 L |
| 3.00 | Providing and laying in position batch mixed and machine mix M 25 grade Cement concrete for reinforced concrete using cement content as per approved design mix including pumping of concrete to site but excluding the cost of centering and shuttering reinforcement including admixtures as per IS 9103 to retard concrete setting and improve workability–all work upto plinth level | 820 | CUM | 800 ₹6.6 L | 8,500 ₹69.7 L | 9,000 ₹73.8 L |
| 4.00 | Providing and laying in position batch mixed and machine mix M 25 grade Cement concrete for reinforced concrete using cement content as per approved design mix including pumping of concrete to site but excluding the cost of centering and shuttering reinforcement including admixtures as per IS 9103 to retard concrete setting and improve workability–all work above plinth level upto floor v. | 1,015 | cum | 8,000 ₹81.2 L | 9,000 ₹91.3 L | 9,000 ₹91.3 L |
| 5.00 | Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete TMT Bars as per design (Complete Job) | 2,30,000 | Kg | 78 ₹1.8 Cr | 80 ₹1.8 Cr | 90 ₹2.1 Cr |
| 6.00Centering and shuttering including strutting proping etc and removal of form work for | ||||||
| 6.10 | Foundations, footings bases of columns etc for mass concrete | 820 | sqm | 200 ₹1.6 L | 399 ₹3.3 L | 300 ₹2.5 L |
| 6.20 | Retaining walls, return walls, wall (any thickness) including attached pilasters, buttresses, plinth and string courses fillets etc. | 1,475 | Sqm | 650 ₹9.6 L | 500 ₹7.4 L | 300 ₹4.4 L |
| 6.30 | Suspended, floors, and roofs landings, balconies and acess platform | 950 | Sqm | 60 ₹57,000 | 500 ₹4.8 L | 300 ₹2.9 L |
| 6.40 | Columns, pillars,pier, abutment ,posts and struts | 1,300 | Sqm | 60 ₹78,000 | 600 ₹7.8 L | 300 ₹3.9 L |
Tender Value
₹14.9 Cr
Closing Date
30 Dec 2021, 4:00 pmClosed
Executive Engineer
PWD(RnB) Division Rajouri
Balance work of construction of Medical college Hostels for Students Senior Junior Faculty Resident Doctors Interns teaching hospital and other Allied works in Government Medical College n Associated Hospital Rajouri
2021_PWDJK_152582_1
NIT No 107 of 2021-22 Dated 09-12-2021
Open Tender
Civil Works
365 days
Rajouri
Plz referNIT
3 documents required · 3 mandatory
₹6,000
Executive Engineer
Exempted
Jammu
19 Jan 2022
10 Dec 2021
31 Dec 2021
11 Dec 2021
30 Dec 2021
11 Dec 2021
17 Dec 2021
Amount
Earth work in excavation by mechanical means(Hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 mtr in width as well as 10 sqm on plan) in all kinds of soil including rock and disposal of surplus, excavated earth at dumping sites to be purchased by the contractor and approved by the engineer-in-charge at site for safe disposal of same without damaging private /public property and all required leads/lifts and carriage.(Complete job)
Providing and laying in position Cement concrete of specified grade excluding the cost of centering and shuttering–all work upto plinth level 1:5:10 (1 cement : 5 coarse sand : 10 graded crushed stone aggregate 40 mm nominal size)
Providing and laying in position batch mixed and machine mix M 25 grade Cement concrete for reinforced concrete using cement content as per approved design mix including pumping of concrete to site but excluding the cost of centering and shuttering reinforcement including admixtures as per IS 9103 to retard concrete setting and improve workability–all work upto plinth level
Providing and laying in position batch mixed and machine mix M 25 grade Cement concrete for reinforced concrete using cement content as per approved design mix including pumping of concrete to site but excluding the cost of centering and shuttering reinforcement including admixtures as per IS 9103 to retard concrete setting and improve workability–all work above plinth level upto floor v.
Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete TMT Bars as per design (Complete Job)
Centering and shuttering including strutting proping etc and removal of form work for
Foundations, footings bases of columns etc for mass concrete
Retaining walls, return walls, wall (any thickness) including attached pilasters, buttresses, plinth and string courses fillets etc.
Suspended, floors, and roofs landings, balconies and acess platform
Columns, pillars,pier, abutment ,posts and struts
Lintels, beams, plinth beams, girders, ressumers & cantilevers.
Edges of slabs breaks in floor and wall and wall under 20cm wide
Filling excavated earth (excluding rock) in trenches, plinth, sides of foundations and embankment etc in layers not exceeding 20cm in depth consolidating Nos deposited layer by ramming and watering, lead upto 50Mt & lift upto 1.50M
Brick Work with common burnt clay FPS (non modular) bricks of class designation 75 in super structure in cement mortor 1:6 (1 cement : 6 fine sand).
Half brick masonry with bricks of class designation 75 in foundation, plinth and superstructure upto floor V-level in cement mortar 1:4 (1 cement : 4 coarse sand).
15mm thick cement sand plaster of mix 1:6 (1 cement : 6 fine sand)
6mm thick cement sand plaster of mix 1:3 (1 cement : 3 fine sand)
Providing and laying in position cement concrete of specified grade excluding cost of cenetring and shuttering-all works upto plinth level 1:5:10 ( 1 cement : 5coarse sand :10 brick aggregate 40mm nominal size)
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately) sal wood.
Providing 40x5mm flat iron hold fast 40cm long including fixing to frame with 10mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Extra for providing edge moulding to 18mm thick Granite stone counters, Vanities etc. over item No. 8.2 including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge
Providing and fixing Ist quality ceramic glazed tiles conforming to IS : 13753 of minimum thickness 5mm of approved make like NITCO, ORIENT, SOMANY, RAK or equivalent make in all colour, shades except burgundy, bottle green, black of any size as approved by Engineer in charge in skirting, risers of steps and dodos over 12mm thick bed of cement mortar 1:3 (1cement : 3coarse sand) and jointing with grey cement slurry @ 3.3Kg per sqm including pointing in white cement mixed with pigment of matching shade complete 300 x 450mm Carona Beige and Carona Brown / Fabricon Brown and Fabricon Creema/Tivoli Brown and Toivoli Creema / Fab Cafe and Fab Creema.Size of tile 30x 60cm.
Providing and fixing 7.3mm thick ceramic glazed floor tiles (non-skidding) 300x300mm (thickness to be specified by the manufactures) of Ist quality conforming to IS : 13755 of NITCO, ORIENT, SOMANY, KAJARIA or equivalent make in colour such as white, Ivory, Grey, Fume Red, Brown laid on 20mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc. complete (12 x 12) matching floor / Sandra Mint/Barcoda Creema / Neo Creema/Textilo Bwown.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 of approved make like NITCO, ORIENT, SOMANY, RAK or equivalent in colours and shade approved S&P Brown and Grey laid on 20mm thick cement mortar 1:4 ( 1cement 4 coarse sand) including grouting the joints with cement grout and matching pigments etc complete.
Providing and laying integral cement based water proofing treatment including preparation of surfaces as required for treatment of roofs, balconies, terraces etc. (consisting of (a) applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks / brick bats 25mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining was upto 300mm height including rounding of junction of walls and slaps. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg / sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge. (iv) Finishing the surface with 20mm thick joint less cement mortar of mix 1: 4 admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge including laying glass fiber cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300mm / sq 3mm deep. (e) The whole terrace so finished shall be flooded with water far a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by Engineer-in-charge. With average thickness of 120mm and minimum thickness at khurras as 65mm.
Providing & fixing glazed shutters 35mm thick for doors, windows and clear story windows using 10Kg/Sqm (4mm thick) glass panes including stainless steel but hinges of size 75mm x 62mm x 2mm of make Kitch, Arch, Blum with necessary stainless screws in second class kail wood.
Providing and fixing 35mm thick wire gauze shutters using galvanized M.S. wire gauge of average width for aperture 1.4mm in both direction with wire of dia 0.63mm for doors, windows and clerestory windows with stainless steel but hinges of size 75mm x 62mm x 2mm of make Kitch, Arch, Blum with necessary stainless screws in second class kail wood.
Providing and fixing of glass panes weighing 13.75 kg/sqm (5.5mm thick) withkail wood fillets.
Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. With ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws 30 mm
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchors blocks, plain window sills, fillets etc upto floor V level, including curing but excluding the cost of centring, shuttering and finishing with 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Random Rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 (1 Cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) upto plinth level andcuring complete with: Cement mortar 1:6 (1 Cement : 6 coarse sand)
Providing and laying 0.90 mtr. Dia RCC Hume Pipes in position including cost of pipes ,lead,lift carriages complete job.(NSI)
Providing and laying 0.60 mtr. Dia RCC Hume Pipes in position including cost of pipes ,lead,lift carriages complete job.(NSI)
Providing and fixing M.S grills of required pattern in frames of windows etc. with M.S flats, square or round bars etc. all complete (fixed to openings/wooden frames with rawl plugs, screws etc.).
Steel work welded in built-up sections/framed work including cutting hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required in gratings, frames, guard bar, ladders, railings, brackets, gates and similar work.
Providing and fixing stainless steel tower bolts ISI marked of make Kitch, Arch, Blum with necessary stainless screws as per directions of Engineer-in-charge.
Providing and fixing stainless steel Aldrops door bolts ISI marked of make Kitch, Arch, Blum with necessary stainless screws as per directions of Engineer-in-charge 250x14mm.(N.S.I)
Providing and fixing stainless steel handles ISI marked of make Kitch, Arch, Blum with necessary stainless screws as per directions of Engineer-in-charge.
Providing and fixingat site Polyvinyl chloride sheet 400 mircon thick complete job design and pattern as per the direction of Engineer-in-Charge (NSI)
Providing and laying 18mm thick Granite of any colour and shape gang saw cut mirror polished (pre moulded and pre polished), machine cut for kitchen platform, vanity counters window sills facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding and polishing to edge to give high gloss finish etc. complete at all levels.
Providing and fixing 10mm thick acid and / or alkali resistant tiles of approved make and colour using acid and / or alkali resisting mortar bedding and joints filled with acid and / or alkali resisting cement as per IS : 4457 complete as per direction of Engineer-in-charge. In flooring on a bed of 10mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand). Acid and alkali resistant tile
Providing and laying water proofing treatment to vertical and horizontal surface of depressed portions of W.C., kitchen and the consisting of (i) Ist course of applying cement slurry @ 4.4 kg /sqm mixed with water proofing compound conforming to IS : 2645 in recommended proportions including rounding of junctions of vertical and horizontal surface. (ii) IInd course of 20mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportions including rounding of junctions of vertical and horizontal surface. (iii) III course of applying blown or / residual bitumen applied hot at 1.7 kg per sqm of area. (iv) Ivth course of 400 micron thick PVC sheet (Overlaps at joints of PVC sheet should be 100mm wide and pasted to Nos other with bitumen @ 1.7 kg/sqm
Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion. Single socketed pipes of 150 mm diameter.
Providing and fixing on wall face unplasticised-PVC moulded fitting / accessories for unplasticised- rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion :-
Coupler 150 mm.
Single tee with door 150 x 150 x 150 mm.
Bend 150 mm.
Steel work in built up tubular round, square or rectangular including cutting, hoisting , fixing in position and applying a primary coat of approved steel primer including welding and bolting with special shaped washers etc. completed. Hot finished welded type tubes
Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rail of T-iron 40x40x6mm with 40mm dia, steel pulley complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a primary coat of approved steel primer,
Providing and fixing 1 mm thick M.S steel sliding-shutters with frame and diagonals braces of 40x40x6mm angle iron, 3mm M.S gusset plates at the junction and corners 25mm dia pulley, 40x40x6mm angle and T-iron guide at the top and bottom respectively including applying a priming coat of approved steel primer,
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building, for all heights and all levels etc. including: a) Structural analysis & design and preparation of shop drawings for pressure equalization or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design.b) Providing, fabricating and supplying and fixing panels of aluminum composite panel cladding in pan shape in metallic colour of approved shades made out of 4mm thick aluminum composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminum sheets (each 0.5mm thick). The aluminum composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanized with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bimetallic contacts all complete required to perform as per specification and drawing The item includes cost of all material &labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium items The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc.including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete,i/c fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required sizeon the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.
Providing and fixing stainless steel hanging double door buffer ISI marked of make Kitch, Arch, Blum with necessary stainless screws as per directions of Engineer-in-charge. (N.S.I)
Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacture, over the plastered wall surface to prepare the surface even and smooth complete.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade new work (two or more coats) over and including priming coat with cement primer.
Finishing walls with water proofing cement paint of required shade new work (two or more coats applied
Finishing walls with rustic regular textured exterior paint of required shade on New work (two or more coats ) over and including base coat of exterior primer applied @ 3.00kg/10sqm(NSI)
Applying priming coat with ready mixed pink or grey of primer of approved brand and manufacture on wood work (hard and soft wood).
Painting with synthetic enamel paint of approved brand and manufacture to give and even shade two or more coats on new work.
Painting with ready mixed synthetic enamel paint of approved brand and manufacture in all shades to give an even shade (two or more coats) on new steel work.
Carriage of material from source to site of work by mechanical transport including loading /unloading and stacking complete
Sand for an average distance of 120 km by M.T
Stone aggregate below 40mm nominal size for an average distance 20 km by M.T
Bricks for an average distance of 140 Km by M.T.
Stones for an average distance of 20 Km by M.T.
Providing and fixing water closet squatting pan (Indian Type W.C Pan) with 100mm sand cost iron P or S trap, 10 ltrs low lewel PVC flushing cistern including flush pipe (Hindware make Cat No. 20070/ Kerovit make Cat No. 606) Manually controlled device (Handle lever) conforming to IS : 7231, with all fitting and fixture complete including cutting and making good the wall and floows wherever required. Orissa Pan white viterous china pan of size 580x440mm with integral type footrests.(N.S.I)
Providing & fixing of white vitreous China pedestial type water closet (European Type) with cistern (A/PHAS-100 Cat No. 201100+Cat No. 21054 / Kerovit model No. 112 and flush tank model no. 1001) with CP bolts, nuts, CI chair hanging arrangements, bakelite seat & cover with CP hinges & rubber buffers, CP brass screw, washer with all accessories with WC connector with Rubber Lip / Buffer and side gap filled with silicon sealant wherever required. Including brass / SS screws and washer complete including cutting, making good the walls, floors, slab wherever required as per direction of Engineer-in-charge.(N.S.I)
Providing & fixing of white vitreous china under counter oval wash basin/circular basin (Hindware 10080 / Kerovit model No. 206 & 207) with CP brass waste assembly, CP cast brass bottle trap with extension piece (Jaquar Cat No. 769B + Parko1535 or approved equivalent), 450mm long CP copper connections pipes (Jaquar Cat No. 803B or Parko 1535 or approved equivalent), wall flanges and rubber adapters for waste connection complete including CI/MS brackets duly painted, nuts, washers, cutting and making good the walls floors wherever required as per direction of Engineer-Incharge.(N.S.I)
Providing & fixing of white vitreous china wash basin with pedestal (Hindware Cat No. 1008 + Ped Cat No. 11003 / Kerovit model No. 234 Ped Model no. 305) with CP brass waste assembly, CP cast brass bottle trap with extension piece (Jaquar Cat No. 769B + Parko1535 or approved equivalent), 450mm long CP copper connections pipes (Jaquar Cat No. 803B or Parko 1535 or approved equivalent), wall flanges and rubber adapters for waste connection complete including CI/MS brackets duly painted, nuts, washers, cutting and making good the walls floors wherever required as per direction of Engineer-Incharge.(N.S.I)
Providing and fixing CP single liver extended basin mixer (height 85mm) without Popup waste system with 450mm long Braided Hoses and brass nuts with all fittings and accessories as per direction of Engineer-in-charge (Jaquar FUS 290238).(N.S.I)
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required. Kitchen sink without drain board 610 x 460 mm bowl depth 200 mm (Pantry)(N.S.I)
Kitchen sink with drain board 510 x 1040mm bowl depth 225mm (Dry Canteen/Kitchen). (N.S.I)
Providing and fixing, testing and commissioning of C.P. brass single hole sink mixer with CP wall flange, swinging spout complete as required and making good as per direction of Engineer-in-Charge (Jaquar Cat No. CQT-23167D) (N.S.I)
Providing & fixing C.P. hand spray with lever control (health faucet) (Jaquar Cat. No. ALDCHR-565 / Kerovit make KA580001) and flexible hose 1 m long connection with C.P. holder for hand spray complete in all respects as per direction of Engineer-Incharge.(N.S.I)
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore (Make Jaquar CQT 23059 / Kerovit make Cat No. KB 1511003). (N.S.I)
Providing & fixing C.P. brass robe hook (Jaquar Cat No. ACN 1191N) or approved equivalent) fixed to wall/door with plastic rawl plugs and C.P brass screws including cutting and making good the walls wherever required as per direction of Engineer-Incharge. (N.S.I)
Providing & fixing recessed liquid soap dispenser (Jaquar Cat No. ACN 1135N) as per direction of Engineer-Incharge. (N.S.I)
P/F of Soap Dish Holder with all fittings as per direction of Engineer-in-charge (Jaquar Cat No. ACN 113 N). (N.S.I)
Providing and fixing of Tumbler Holder with all fittings as per direction of Engineer-in-charge (Jaquar Cat ACN 114 N). (N.S.I)
Providing and fixing Bottle Trap (Jaquar Cat No. ALD. 769L) and other ancillary fittings. Cutting and making good the walls wherever required compete as per directions of Engineer-Incharge.(N.S.I)
Providing and fixing complete set of sanitary fixtures for handicapped toilets, Hindware Cat. no. 70002) comprising of EWC - P , Cistern, Seat Cover, Twin Flush Fittings, Wash Basin 450x300, Half pedestal, 1 faucet with spatula lever, 1 hinged rail and 2 grab bars, including cutting and making good the walls and floors wherever required complete as per directions of Engineer in charge.(N.S.I)
Providing and fixing 6mm copper backed float glass mirror MODI / SAINT-GOBAIN including 6mm thick BWR type ply board, 40mm stainless steel channel plugged to wall, hard wood treated with two coats of wood preservative, etc. all complete as specified and shown in drawing complete to the satisfaction of Engineer in charge. (N.S.I)
Providing and fixing CP brass towel rail of approved make complete with CP brackets fixed to wooden cleats with CP brass screws.(Jaquar Cat No. ACN1111DNM / Kerovit make Cat No. KA 930001). (N.S.I)
P/F brass towel ring round with round flenge of approved make complete with all fittings (Jaquar Cat No. CAN 11021 BN / Kerovit make Cat No. KA 930004). (N.S.I)
Providing and fixing of glass shelf 600m long with all C.P fittings of approved quality complete item (Jaquar Cat No. ACN 11071 N).(N.S.I)
Providing and fixing toilet paper holder with all fittings Jaquar Contienal ACN 1153 N. (N.S.I)
Providing and fixing 15 mm dia. C.P. brass bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. (Short Body) (Make Jaquar Cat No. CQT-23047) (N.S.I)
P/F of regular body concealed stop cock suitable for 15mm pipe line with protection cap (Jaquar Cat No. ALD 083 / Kerovit make Cat No. KB 111030 CP and exposed part Cat No. KB 1511032) with exposed part angular stop cock with flange FUS 29.53.(N.S.I)
Providing and fixing of wall mixer with provision for overhead shower with 115mm long bend pipe on upper side connecting legs and wall flanges of approved quality with all fittings (Jaquar cat no SHA-479L).(N.S.I)
Providing and fixing of wall mounted over head shower 200m dia (Jaquar DHS-CHR-1613) with shower arm 450mm long round shape with 90 degree bend with flanges (Jaquar SHA-479L450) with all fittings. (N.S.I)
Providing and fixing of Polyethylene/Aluminium/Polyethylene (PE-AL-PE) Composite Pipes as per IAPMO IGC- INDIA 308, UMC-1TM certification marked on the pipe at the interval not greater than 1 meter with nominal pipe size with manufacturer’s name or trade mark including all relevant DZR brass fittings as Female Elbows/Tees, MTC /FTC and Engineering plastic fittings with internal sealing system like Eq. elbows, Eq. tees, reducers, Straight couplers Connectors, clamps at one meter spacing, with PAP valves etc. Make Kitec , Maithilee and Vista. Concealed installation including cutting chases and making good in the wall etc, Complete in all respect.
1216 (16mm OD) pipe.
1620 (20mm OD) pipe.
Providing and fixing Polyethelene-Aluminium–Polyethelene (PE-ALPE) Composite Pressure Pipes conforming to IAPMO-IGC-INDIA 308. U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature upto 80 0C, including all special fittings of composite material (engineering plastic blend and and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connector etc. with trenching, refilling and testing of joints complete as per direction of the Engineer-in-charge. External work.
1216 (16mm OD) pipe.
1620 (20mm OD) pipe.
2025 (25mm OP) pipe.
2532 (32mm OP) pipe.
3240 (40mm OP) pipe.
4050 (50mm OP) pipe.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Internal work.
15 mm nominal outer dia Pipes.
20 mm nominal outer dia Pipes.
25 mm nominal outer dia Pipes.
32 mm nominal outer dia Pipes.
Internal work:- Exposed on wall Providing and fixing G.I. Pipes complete with G.I. Fittings and clamps, including cutting and making good the walls etc.
25mm dia. Nominal bore (Hot water supply)
32mm dia. Nominal bore
40mm dia. Nominal bore
Conceal Inside the walls:- Providing and fixing Conceled pipe including painting with anti corrosive bitumastic paint, cutting chases and making good the wall.
20mm dia. Nominal bore
20mm dia. Nominal bore (Hot water supply)
External work Providing and fixing G.I. Pipes complete with G.I. Fittings and clamps, including cutting and making good the walls etc.
20mm dia. Nominal bore
25mm dia. Nominal bore
32mm dia. Nominal bore
40mm dia. Nominal bore
Supplying thermal insulation over hot pipes with 6mm thick "Kaiflex" or Careflex or approved equivalent thermal insulation tubing, a elastomeric flexible material having hermetic blister closed cell structure of expanded synthetic rubber having density of 60-90 kg/m3 over pipes of following sizes including all required accessories complete as per manufacture's specifications and finishing it as per site requirement with cement plaster of 1:3 (1 cement: 3 coarse sand).
20mm dia 9mm thickness
25mm dia 9mm thickness
Providing & fixing full way lever operated forged brass ball valve of brass body with forged brass hard chromeplated steel ball tested to a pressure not less than 15 Kg / sqcm with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc. as per direction of Engineer-Incharge.
15 mm dia. Nominal bore.
20 mm dia. Nominal bore.
25 mm dia. Nominal bore.
32 mm dia. Nominal bore.
40 mm dia. Nominal bore.
50 mm dia. Nominal bore.
65 mm dia. Nominal bore.
Providing & fixing butterfly valve (Body : Grey Cast Iron, Shaft : SS, Disc : SG Iron (Rilson coated), Liner : HT - EPDM) (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 15 Kg/Sq.cm. Including rubber gasket, flanges, nuts, bolts, washers & painting complete as required.
65 mm dia. Nominal bore.
80 mm dia. Nominal bore.
100 mm dia. Nominal bore.
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete.
25 to 40 mm dia. Nominal bore.
50 to 80 mm dia. Nominal bore.
Providing and filling sand of grading zone V or coarser grade, all- round the G.I. pipes in external work.
65 mm nominal bore.
80 mm nominal bore.
Providing and fixing G. I. Union in G. I. pipe including cutting and threading the pipe and making long screws etc. complete (new work).
32 mm nominal bore.
40 mm nominal bore.
50 mm nominal bore.
65 mm nominal bore.
80 mm nominal bore.
Providing & fixing Auto Air vent for cold water supply risers, suitable for pressure not less than 15 Kg/Sq.cm.
15mm dia.
20mm dia.
Earthwork in all kinds of soil excavation by manual means in trenches for foundations, drains, pipes, cable etc. (not exceeding 1.5 in width) and for shafts, wells, cesspits and the like not exceeding 10 Sqm on plan, depth upto 1.5 Mtr including disposal of excavated earth upto 1 Mtr from cutting edge, disposed earth is to be levelled and neatly dressed.
Providing and fixing un-plasticised PVC pipe clips of approved design to un-plasticised un-plasticised rain water pipes by mean of 50X50X50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
75MM pipe
110MM pipe
160MM pipe
Construction brick measonery man hole in cement motor 1:4 (1 cement: 4 Coarse Sand) R.C.C top slab with 1:2:4 mix (1 cement: 2 Coarse Sand: 4 graded stone aggrigate 20 mm nominal size) foundation concrete aggrigate 40 mm Nominal Size, in side palstering 12mm thick with cement mortor 1:3 (1 cement:3 Coarse sand) finshed with floating coat near cement and making channels in cement concrete 1:2:4 (1 cement:2 Coarse snad:4 graded stone aggirgate 20mm nominal size) finished with floating coat of neat cement complete as per standard design. inside size 90cmx80cm and 45cm deep including cast iron cover with frame (light duty) 455x610mm internal dimensionals. total wt. of cover and frame to be not less than 38kg (wt. of cover 33kg and wt.of frame 15kg) with F.P.S bricks of class designation 75 (crush stone aggrigate)
Constructing masonry Chamber 60 x 60 x 75 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 fine sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chain lid and RCC top slab 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design. (With F.P.S. bricks)
Providing and fixing Heavy class SS grating with Cockroach proof SS strainer of approved design including setting in floor with cement motor to match with floor finish as per direction of Engineer-Incharge. (Size 100 mm dia) (ISI Marked)
Providing and fixing heavy class SS grating plane including setting in floor with cement motor to match with floor finish as per direction of Engineer-Incharge (Size 100 mm dia) (ISI Marked)
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank (Sintex, Electroplast, star, Lotous or equivalent having valid ISI license) (1000 ltr. Capacity 15 No.).
Making soak pit 2.5m diameter 3.0 M deep with 45x45cm dry brick honey comb shaft with bricks of class designation 75mm and S.W. drain pipe 100mm diameter 1.8 m long complete as per standard design with FPS bricks.
Supply, assembly, erection, testing and commissioning of pumping system comprising the following:
Vertical/Horizontal centrifugal pumps (1 Working + 1 Stand-by) with mechanical seal, SS Volute casing and SS impeller connected to suitable capacity TEFC induction motor suitable for 415 ± 10 % volts, 3 phase, 50 cycles A.C. supply with 100 mm dia. pressure gauges including MS skid and mounting of the pumps on the skid. (Motor to be of the same make as the pump) (wilo,ebara and matherplatt etc.)
Pump Capacity 180 lpm, at 30 m head (1 working + 1 standby) (Domestic water relift pump).
Wiring for light point/ fan point/ exhaust fan point/ call bell point excluding junction boxes in slab with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in existing surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
Group A
Group B
Group C
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group A
Group B
Group C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
2 x 2.5 + 1 x 2.5sq. mm
2 x 4.0 +1x4.0 sq. mm
2 x 6.0 +1x6.0 sq. mm
4 x 6.0 +2x6.0 sq. mm
4x10.0 + 2x6.0sq.mm
4x16.0 + 2x6.0sq.mm
TV Cable in existing conduit : Supplying and drawing co-axial TV cable RG-6 grade, 0.7mm solid copper conductor PE Insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/recessed steel/PVC conduit as required.
S/F PVC Conduit Supplying and fixing of following sizes of Medium Class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of Recessed conduit as required
S/F modular boxes, base and cover plate : Supplying and fixing following size/modules , GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
1 or 2 module ( 75mm x 75mm)
3 Module (100mmX75mm)
4 Module ( 125mm x 75mm)
6 Module( 200mm x 75mm)
S/F power plug point modular type accessories: Supplying and fixing on exisitng GI Box modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 & 5/6 amps modular socket outlet and 15/16 amps modular switch, connection, painting etc as required.
S/F Modular type switch/socket : Supplying and fixing following modular switch / socket on th existing modular plate & switch box including connections but excluding modular plate etc. as required
5/6Amp Switch
3 pin 5/6 Amp socket outlet
Telephone socket outlet
TV antenna socket outlet
Bell Push
32A DP Switch equiv to 572154 of Legrand
S/F modular type electronic fan regulator: Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. Fan Regulator shall conform to IS11037
S/F modular type blanking plate: Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
ITC fluorescent fitting directly on surface : Installation, testing and commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/ LED lamps per fitting, complete with all accessories including connections etc. as required.
ITC Ceiling Fan : Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
ITC exhaust fan upto 450mm sweep: Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep
Fixing louvers/shutters for exhaust fan: Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
Telephone wiring in existing conduit: Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required.
S/F 'C' series , SP MCB: Supplying and fixing 5 amps to 32 amps 10kA rating, 240 Volts, 'C" series, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
S/F 'B' Series, SP MCB blanking plate Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
P/F M.V. danger notice plate : Providing and fixing M.V. danger notice plate of 200mm x 150mm , made of mild steel, at least 2 mm thick , and viterous enamelled white on both sides, and with inscription in single red colour on front side as required.
Supplying and fixing following items in the existing MCB DB complete with connections, testing and commissioning etc. as required.
63A four pole rating, 415 Volts, MCB C Series, 10kA ISI Marked
40A four pole rating 415V, MCB C Series, 10kA ISI Marked
25A four pole rating, 415 Volts, MCB C Series, 10kA ISI Marked
25A two pole rating, 415 Volts, RCCB, 100mA Sensitivity ISI Marked 12640-2
40 amps two pole rating, 415 Volts, RCCB, 100mA Sensitivity ISI Marked 12640-2
63amps two pole rating, 415 Volts, RCCB, 100mA Sensitivity ISI Marked 12640-2
Supply, Installation, Testing and commissioning of following Distribution boards made of sheet steel in Distribution Boards with sheet metal door of Legrand(Ekinoxe3) or equivalent in Siemens/Schneider makes
4Row x 14 Module
3 Row x 14 Module
2 Row x 14 Module
Supply of following LED lighting fixtures of following specification Supply of 20/22 Watt LED 4 feet tube light fitting CRCA housing with 2000 lumens and min. lumens efficiency 100 lumens/watt PF 70.95 THD<16% and voltage input range 140-270V with short circuit and overloading protection circuit off.
Supply of 12w max surface rimless downliter, Pressure die cast alluminium body, 100 Lumens/watt, 1200 lumens CCT 5700/6500K, CRI >80, voltage range 140-270v AC, THD <10%, Surge protection 2.5 kv, IP20 rating
LED Bulkhead fixture IP65 equivqlent to PBHM01107 of Panasonic made of polycarbonate, 1000 lumsn output with efficacy of 100 lumens/watt.
Supply of Wall / Ceiling Fans 230V 50Hz celing fan with double ball bearing with low power consumption of following sweeps
1050mm Ceiling Fan
1200mm Ceiling Fan
1400mm Ceiling Fan
400mm Wall Fan
Supply of following sizes of heavy duty exhaust fan as per approved makes : Bajaj/Usha/Khaitan/Havells/Polycab
450mm Sweep
300mm Sweep
250mm Sweep
Supply, Installation, Testing and commissioning of Indoor Floor Mounted Low Voltage floor panel suitable for operation on 433V 3 Phase, 50Hz supply, enclosure made of 2.0mm thick CRCA sheet steel material Alumium bus bar with following switchgears and metering. Necessary arrangement be made for termination of incoming cable and outgoing cables. Contractor to get the G.A. drawings approved before execution.. Job includes making foundation for external lighting panel of Suitable size with provision for incoming and outgoing cables. ( Manufacturer shall be having CPRI type test certificate for 50kA Short Circuit issued not more than 5 years earlier from the date of supply) Incomer : 125A 4pole MCCB intergrated with multifunction meter with LCD/LED display Ics=Icu=25kA - 1 Nos. 100A 4pole MCCB intergrated multifunction meter with LCD/LED display Ics=Icu=25kA - 1 Nos. , Busbar : 300A Aluminium TPN Bus bar Electrolytic grade having 57% IACS supported on DMC insulators on Mains and DG. Outgoings :100A 4pole MCCB Ics=Icu=25kA - 9 Nos 63A 4ole MCCB Ics=Icu=25kA - 9 Nos All Incomer and outgoing MCCBs shall be have adjustable overload release and spreader link on both sides of MCCBs and Rotary Handle. Phase Indication LED Lamps for all incomers.
Supply, Installation, Testing and commissioning of MS Angle frame (600mm height ) Mounted Low Voltage panel IP54 suitable for operation on 433V 3 Phase, 50Hz supply, enclosure made of 2.0mm thick CRCA sheet steel material Aluminium bus bar with following switchgears and metering. Necessary arrangement be made for termination of incoming cable and outgoing cables. Contractor to get the G.A. drawings approved before execution. Make of LV Panel Manufacturer ( Manufacturer shall be having CPRI type test certificate for 50kA Short Circuit issued not more than 5 years earlier from the date of supply) Incomer : 400A 4pole MCCB intergrated multifunction meter with LCD/LED display Ics=Icu=36kA - 1 Nos. 125A 4pole MCCB intergrated multifunction meter with LCD/LED display Ics=Icu=25kA - 1 Nos. Busbar :500A Aluminium TPN Bus bar supported on DMC insulators Outgoings : 160A 4pole MCCB Ics=Icu=25kA - 8 Nos 100A 4ole MCCB Ics=Icu=16kA - 8 Nos All Incomer and outgoing MCCBs shall be have adjustable overload release and spreader link on both sides of MCCBs. Phase Indication LED Lamps for all incomers.
Supply, Installation of 10 pair Telephone krone box suitable for Termination of 10 Pair Telephone cable including Krone connectors for 10 Pair cables. Hensel make
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
63 mm dia (OD-63 mm & ID-51 mm nominal)
120 mm dia (OD-120 mm & ID-103 mm nominal)
160 mm dia (OD-160 mm & ID-135 mm nominal)
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc as required
Supply of 1.1kV Grade Power cables with Aluminum Stranded Conductor, XLPE Insulated,Cores Laid Up, PVC innersheathed, Armoured , Extruded PVC Type ST2 Sheathed, 650/1100V Grade As Per IS 7098(Part 1) 1988.
3.5Cx400sqmm
3.5cx240sqmm
3.5cx95sqmm
3.5cx50sqmm
3.5cx35sqmm
3.5cx25sqmm
4cx16.0sqmm
2cx10.0 sqmm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Supply of following Octagonal Galvanised Steel Poles Makes including luminaire mounting Bracket / Headframe, foundation bolts as per approved design/drawing. GA drawing of Mast and foundation drawing to be submitted .The poles shall be designed based on loading details of luminaires and as per IS 875 and other relevant standards.
7m with Single Arm
9m with Single Arm
Supply of 4.5m Pole made of ISI Galvanised Medium Pipe of 80mm dia duly painted with approved color including luminaire mounting Bracket as per approved design/drawing. Foundation above Ground level shall have provision for fixing of Cable junction box.
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required, size as per Engineer-in-charge.
Above 4.5 metre and upto 6.5 metre
Above 6.5 metre and upto 8.0 metre
Above 8.0 metre and upto 10.0 metre
Providing and making steel pole collar with cement concrete (1 cement : 3 coarse sand : 6 stone aggregate 20mm) of specified size and shape including form work, plastering if required, curing etc as required, size as per Engineer-in-charge. (volume of pole/ pipe not to be deducted)
Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required.
40 mm dia
Supplying and drawing following 2.5sqmm of PVC insulated copper conductor, 3 core cable in the existing surface/ recessed steel/ PVC conduit as required.
Supply , Installation , Testing and commissioning of LED Post Top with a system lumen output of 2000 lumens and a minimum system efficacy of 80 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 3000K/4000K and CRI > 70. The luminaire shall meet IP65 with THD < 20% and PF > 0.9. The luminaire shall have closed diffused optics with polycarbonate diffuser board. The total power consumption should not exceed 30W (including driver). Job includes wiring with 3x2.5 sqmm wire, making terminations etc.
Supply and Installation of 12.5m High Mast including foundation bolts with Motorised Carriage suitable to carry LED Flood lights along with accessories. Mast shall be made of Galvanised Steel Sheet of 4mm Thickness with Top Dia of 166mm and Bottom Dia of 410mm. The accessories such as rope system, suspension system, drum wich and power tool shall be as per relevant IS. Thickness of Galvanisation shall be min. 65 microns for top and 86mm for bottom. Weight of mast shall be between 450 to 475kgs. GA drawings for the mast Foundation design shall be provided by mast manufacturer after placement of purchase order for verification and approval.
Supply and Installation of Loop in Loop out thermoplastic cable junction box suitable for 25sqmm 4C loop in loop out of aluminium cable Outdoor weather proof made black color IP67 along with terminals of along with loop in loop out Terminals and one no. 6A SP MCB on Din Rail, internal wiring, mounting clamp complete job
Supply, Installation , Testing and commissioning of LED basedStreet light, housing made up of Pressure Die Cast Housing LM 6 Alloy/ Anti Dust Exposed Lens,sturdiness and embossed brand name/logo name of manufacturer. The fixture should have a minimum system efficacy of 100 lumen/Watt and a minimum system lumen output of 7200 lumens and maximum system wattage of 70+5/-5 Watts.The fixture shall have a CRI of minimum 70. The fixture shall be designed for a system life of 50,000 hours @70% lumen maintenance. Ingress Protection of IP66 (lamp and gear Compartment) and Mechanical Impact Resistance Rating of IK >=05.The fixture driver should have an operating voltage range of 140-270 V, surge protection of >=3KV, PF >0.9 , THD<20% and SDCM<5. The driver should be BIS approved, fully potted and encapsulated .The fixture should comply with the parameters as per IS10322. The LED driver should comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, IEC62384 ed.1.1, 2011 for performance and IEC61547 ed.2.0, 2009, CISPR-15 for EMI. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters.
Supply, Installation , Testing and commissioning of LED based Street light, housing made up of Pressure Die Cast Housing LM 6 Alloy/ Anti Dust Exposed Lens,sturdiness and embossed brand name/logo name of manufacturer. The fixture should have a minimum system efficacy of 100 lumen/Watt and a minimum system lumen output of 9400 lumens and maximum system wattage of 90+5/-5Watts.The fixture shall have a CRI of minimum 70. The fixture shall be designed for a system life of 50,000 hours @70% lumen maintenance. Ingress Protection of IP66 (lamp and gear Compartment) and Mechanical Impact Resistance Rating of IK >=05.The fixture driver should have an operating voltage range of 140-270 V, surge protection of >=3KV, PF >0.9 , THD<20% and SDCM<5. The driver should be BIS approved, fully potted and encapsulated .The fixture should comply with the parameters as per IS10322. The LED driver should comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, IEC62384 ed.1.1, 2011 for performance and IEC61547 ed.2.0, 2009, CISPR-15 for EMI. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters.
Supply , Installation Testing and commissioing of LED based Flood light, housing made up of pressure die cast aluminum Alloy with effective thermal management,sturdiness and embossed brand name/logo name of manufacturer. The fixture should have a minimum system efficacy of 110 lumen/Watt and a minimum system lumen output of 15000 lumens and maximum system wattage of 140+5/-5 Watts.The fixture shall have a CRI of minimum 70. The fixture shall be designed for a system life of 50,000 hours @70% lumen maintenance. Ingress Protection of IP66 (lamp and gear Compartment) and Mechanical Impact Resistance Rating of IK >=05.The fixture driver should have an operating voltage range of 140-270 V, surge protection of >=3KV, PF >0.9 and THD<20%. The fixture should comply with the parameters as per IS10322. The LED driver shall comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, IEC62384 ed.1.1, 2011 for performance and IEC61547 ed.2.0, 2009, CISPR-15 for EMI. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters.
Supply Installation Testing and commissioning of LED based Flood light, housing made up of pressure die cast aluminum Alloy with effective thermal management, sturdiness and embossed brand name/logo name of manufacturer. The fixture should have a minimum system efficacy of 100 lumen/Watt and a minimum system lumen output of 26000lumens and maximum system wattage of 250+5/-5Watts.The fixture shall have a CRI of minimum 70. The fixture should have assymetric/ symmetric narrow beam and Narrowm beam angle options available. The fixture shall be designed for a system life of 50,000 hours @70% lumen maintenance. Ingress Protection of IP66 (lamp and gear Compartment) and Mechanical Impact Resistance Rating of IK >=05.The fixture driver should have an operating voltage range of 140-270 V, surge protection of >=3KV, PF >0.9 and THD<20%. The fixture should comply with the parameters as per IS10322. The LED driver should comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, IEC62384 ed.1.1, 2011 for performance and IEC61547 ed.2.0, 2009, CISPR-15 for EMI. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India.LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters.
Supply, Installation , Testing and commissioning of LED Bollard light Long life time high power LED light source >25,000 hours, 70% lumen maintenance having Neutral white(NW) Light output with min Lumen o/p of 300lumens power consmption shuld not be more than 8+1/-1W. Aluminum housing with glare free polycarbonate Diffuser tube & silicone rubber, heat-resistant gasket for maintaining IP 65 / IK10 / Class I. Ht should not be more than 0.5m. Provision for cable junction box shall be made in fondation. PCC (1:2:4) Foundation shall be 450mmx450mmx1000mm
Supply, installation, testing & Commissioning of long life maintenance free Ring Earthing System consisting of UL Listed 1No copper coated 14.2 mm dia Solid steel Rods shall be made of high tensile low carbon steel rod, with molecular bonded with 99.9% electrolytic copper coating of 250 mircon min, minimum length of the earth rod shall be 3 meters . The rod shall be surrounded by Earth Enhancement compound Procem , that has to produce low resistance of an earth termination system and it should not danger to persons and the surroundings 12.5 kg or sufficient quantities required as per the conditions. Heavy duty Fibre Glass Reinforced Under floor earth inspection should have dimension of 250 mmX 150 mm X 130 mm . Flush Mounted, removable and of the earth pit should be able to withstand 5000 Kg. The systems has to be conforming to IEC 60364, IEC 62561, IEC 62305, IS 2309 & IS 3043.
Supply , Installation of indoor equipotential bonding rail equivalent to 1801VDE including connections to earth conductors
Supply , Installation of outdoor equipotential bonding rail including connections to earth conductors
Supply and laying 5052 DIN 30x3 flat conductor of size 30mmx3mm , galvanised steel having weight of 70.65kg/100m in ground/at surface.
Supply and laying of 8mm round conductor aluminium
Supply, Installation, Testing and commissioning of Outdoor IP54 (MS Angle frame of height 600mm above foundation) Mounted Low Voltage panel (Street Lighting/Flood Lighting)suitable for operation on 433V 3 Phase, 50Hz supply, enclosure made of 2.0mm thick CRCA sheet steel material Alumium bus bar with following switchgears and metering. Necessary arrangement be made for termination of incoming cable and outgoing cables. Contractor to get the G.A. drawings approved before execution.. Job includes making foundation for external lighting panel of Suitable size with provision for incoming and outgoing cables.Make of LV Panel Manufacturer ( Manufacturer shall be having CPRI type test certificate for 50kA Short Circuit issued not more than 5 years earlier from the date of supply) Incomers 63A 4P MCCB 25KA - 1 Nos All Incomers shall be provided with digital multi function metering set of suitable rating CTs etc. 40A 4 Pole Contactor - 2Nos., Astronomical time Switch 2 Channel Busbar : 300A Aluminium TPN Bus bar supported on DMC insulators Outgoings : 63A 4P MCB - 6 Nos All MCCBs shall have overload adjustable setting 80-100% for overload and adjustable short circuit setting. Phase Indication LED Lamps for all incomers and outgoings to be provided. ON Off Trip Indication LED Lamps to be provided for all incomer and outgoings.
Supply, Erection, Testing and Commissioning of ONAN 1600 kVA 11kV/433V step down Transformer , 3 phase, 50 Hz, 11kV/433Vs,solidly earthed system, vector group Dyn-11, with On Load Tap changer having a voltage correction range of +5% to -15% on 11kV side of Transformer along with Remote tap Changer Panel, Automatic Voltage Regulator. The Transformer shall be aluminium wound , natural air cooled, having termination arrangement of cables of 11kV and 433V side . The losses of transformer shall be as per latest/ existing Energy Conservation Building Code(ECBC) rule and BEE Guidelines .Make of Transformer : PDD/PGCIL APPROVED Make of OLTC : CTR/OLG.The Transformer shall be base mounted on a RCC ( 1:2:4) foundation. Civil works mentioned above for Transformer mounting and chain link fence not is scope of this item and shall be done under civil works scope. OLTC make : PDD/PGCIL APPROVED.
Supply, Erection, Testing and Commissioning of ONAN 1000 kVA 11kV/433V step down Transformer , 3 phase, 50 Hz, 11kV/433Vs,solidly earthed system, vector group Dyn-11, with On Load Tap changer having a voltage correction range of +5% to -15% on 11kV side of Transformer along with Remote tap Changer Panel, Automatic Voltage Regulator. The Transformer shall be copperwound , natural air cooled, having termination arrangement of cables of 11kV and 433V side . The losses of transformer shall be as per latest/ existing Energy Conservation Building Code(ECBC) rule and BEE Guidelines .Make of Transformer : Schneider/Areva/ABB/GE/Legrand/Voltamp Make of OLTC : CTR/OLG.The Transformer shall be base mounted on a RCC ( 1:2:4) foundation. Civil works mentioned above for Transformer mounting and chain link fence not is scope of this item and shall be done under civil works scope. OLTC make : OLG/CTR.
Supply, Installation Testing and commissioning of 900/910 KVA DG Set consisting of A. Diesel engine - 16 cylinders, liquid cooled, turbocharged with after cooler, developing 1086 hp @ 1500 RPM, V type, 4 valve per cylinder, electric start, compression ignition, 4 stroke engine designed to run continuously at 1500 RPM confirming to rime rating ISO-3046 standard with an overload capacity of 10 % for one hour in every 12 hrs of operation. Diesel Engine shall conform to latest applicable CPCB norms. The diesel engine shall comprise of Air filter, Lube oil cooler assembly with accessories, Exhaust air manifold, Exhaust Silencer, Expansion bellow, Fuel filter, Lube oil filter, Exhaust gas Turbocharger with after cooler, Radiator with pusher type fan, with fan guard, coolant pump, 24 V (2 x 12 V) electrical starting system with starter motor and battery charging alternator, Common Rail Direct Ignition design for fuel with Electronic Governing & Isochoronus capability, Engine mounting supports, Engine control panel – Microprocessor based Controller, Engine Safeties , Alarms and Trips, K Cool super plus corrosion inhibitor coolant for cooling, Engine Operator/Maintenance & Spare parts CD, Engine Warranty Certificate, Engine test certificateAlternator - 900 / 910 KVA, 415 Volts, 3 Phase, 4 wire, 0.8 p.f. (lag), 50Hz, 1500RPM, in accordance with IS 4722 as per following specifications- Salient poles type, Single bearing, Brushless type, suitable for direct coupling to engine, shall be guaranteed to deliver required output at the ambient temperature condition, suitable for an over‐load of 10% for 1 hour in every 12 hour of operation, Voltage Regulation to be provided with fast response thyristor type electronic automatic voltage regulator, which can holds output voltage within desired limits. (+/‐ 1%)., Excitation: Self excited‐self regulated, Alternator shall be suitable for taking rated load immediately after machine reaches rated voltage and speed , shall be equipped with AREP (Auxiliary regulation Exciting Principle) winding to give performance equivalent to PMG as standard scope of supply, suiitable for direct coupling with Engine and mounted on common fabricated sheet metal base frame, enclosure shall be SPDP IP – 23 degree of protection, Air Cooled type with radial fan mounted on Rotor and Insulation class H as defined in IS – 4722. MS Base Frame suitable for mounting of the offered engine and alternator, fuel tank of capacity 990 litres complete fuel gauge, inlet/outlet connections, drains plug, etc., 2 No. 12 Volts DC Battery of suitable capacity with leads, 1 Set of AVM Pads fitted in Base Frame, All above accessories shall be housed in acoustic enclosure. Makes : Engine : Cummins/Caterpillar/Kirloskar/Ashok Leyland Alternator : Leroy Somer/Kirloskar/Crompton/AVK
Providing Exhaust Stack for 900 kVA DG Set for extended exhaust upto top of building (of appx 25-30m height or as per CPCB Norms ) including steel work, Exhaust Pipe of suitable size, concrete foundation work etc complete job. Contractor shall get the general drawing approved before starting the work.
Supply, Installation, Testing and commissioning of Floor Mounted Low Voltage indoor panel IP 42 suitable for operation on 433V 3 Phase, 50Hz supply, made of 2.0mm CRCA sheet enclosure with Copper bus bar Four wire with following switchgears and metering. Necessary arrangement be made for termination of incoming cable and outgoing cables . LT Panel shall be manufactured as per IS8623 .All accessories such as shunt coils, UV release, contact blocks, locks and keys as required by the scheme shall be included in the panel price while quoting. Contractor to get the G.A. drawings approved before execution. Make of LV Panel Manufacturer ( Manufacturer shall be having CPRI type test certificate for 50kA Short Circuit issued not more than 5 years earlier from the date of supply) Incomer : 2500A 4pole EDO Air Circuit Breaker with microprocessor based communicable release Ics=Icu=50kA - 2 Nos integrated with digital multifunction meter 2500A 4pole EDO Air Circuit Breaker without release1 Nos Phase Indication LED Lamps shall be provided on each incomer All incomers shall be provided with Surge protection device of Type 1and 2 All mains incomers to be provided with protections against overvoltage, reverse power , undervoltage, over/under frquency, single phasing using relays as required.Interlocking between main incomers, bus couplers as per the required scheme Busbar : 3000A 50kA ,4 Wire Copper Bus Bar electrolytic grade supported on DMC Insulators Outgoings :1600A 4pole EDO Air Circuit Breaker with microprocessor based communicable release, Ics=Icu=50kA - 2 Nos ,integrated with digital multifunction meter 630A 4P MCCB 36kA - 5Nos. 250A 4P MCCB 36kA - 2Nos. 100A 4P MCCB 36kA - 3Nos. All MCCBs shall be have overload adjustable setting 80-100% and shall be installed with Rotary Operating machanism spreader link sets both sides. All Air Circuit Breakers shall be have overload adjustable setting 40-100%, with microprocessor release with communication port , . There shall be protections inbuilt in ACB against rise of temperature in ACB above 75DegC.
Supply of 11m Long 410 SP 56 Swaged tubular pole as per IS 2713
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 10m upto 12m
Supply and laying of Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound , XLPE Insulated, Insulation screening With Extruded Semi Conducting Compound In Combination With Copper Tape, Al Round Wire Armoured And Overall PVC Sheathed Cable Conforming to IS 7098 / (Part-II) 1985 With The Latest Amendments.11kV cable 3Cx120 sqmm Aluminium armoured XLPE insulated cable as per IS 7098 as required at site
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :
supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :
Supply, Insta`llation Testing and commissioning of IP CCTV system suitable for integration with Networks consisting of the following components, contractor to quote considering all components that may be required to complete the jsystem as per owner satisfaction, no extra cost shall be paid for any item requred to complete this job.
4 MP Resolution with IR Range 50 mtrs approx., POE, 1/3'' Progressive Scan CMOS IP66 Bullet IR Network Camera with Motorized Varifocal
4 MP Resolution with IR Range 50 mtrs approx., POE, 1/3'' Progressive Scan CMOS IP66 Dome IR Network Camera with Motorized Varifocal
Outdoor Network PTZ Camera wirh 1920x1080 resolution, support H.265 video compression Dome Type , WDR, upto 100m IR Distance, 25X optical zoom, 16X digital zoom, Pan and Tilt , IP66 with inbuilt surge, lightening and transient voltage protections
Network Video Recorder 16 channel of IP , delivering 4K/4MP/2MP video resolution, H.265. Real time video recording at 4MP/2MP resolution.
6TB Hard disk
24 Ports Layer 2 Non-PoE Switch at Control Room : 26-Port 10/100/1000 Base-T Gigabit Layer 2+ Managed Switch with 4 Gigabit Shared SFP Ports and External RPS support
24- Ports Layer 2 PoE Switch : 24-Port 10/100/1000 Base-T Gigabit PoE (8-Port PoE+) Smart Managed Switch with 4 Gigabit Dedicated SFP Slots and Static Routing Support
8 ports Layer 2 PoE Switch: 8-Port 10/100/1000 Base-T Gigabit PoE Smart Managed Switch with 2 Gigabit Fiber SFP Slots
Surge Protector for IP Camera
32" high resolution LED Display with HDMI interface application with all accessories of wall mount
Sanjiv Kumar Sharma
KAPAHI CONTRACTS PRIVATE LIMITED
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 1.66 MB
BOQ_337073.xls
BOQ • 0.59 MB
Download all tender documents and submit your bid