Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.7 LAccepted-AOC | ₹1.7 L | 1 | Accepted-AOC lowest bid |
| 2 | 2₹1.7 LRejected-Finance 25 P NO 310 | ₹1.7 L | 2 | Rejected-Finance HEIGHEST |
| Sl No | Description | Qty | Unit | SASINDRAN E L1 | SHAJI P L2 |
|---|---|---|---|---|---|
| 1.00SITC of Pump set | |||||
| 1.00 | OD127622/2023-2024:Supply, installation , testing and commissioning of open well 5 HP submersible pump set having a discharge of not less than 160 Ltr/minute at a head of 75 mtrs (Head range 50 to 90 mtrs) with suitable impeller, strainer on suction side etc suitable for operation on three phase, 415V 50 Hz AC supply in the existing open well including submersible cable joint, connection to the existing delivery line, including providing and fixing 15 mtr long 10 mm dia SS pump lifting rope with suitable clamps made out of 60 x 10 mm MS flat iron etc. complete as required. ( Make Kirlosker KU6 -508 or equivalent models of Texmo , Lubi, V gaurd, Crompton, KSB) | 1 | each | 56,617 ₹56,617 | 60,000 ₹60,000 |
| 1.00 | OD127619/2023-2024:Providing and fixing 50 mm dia. UPVC medium duty column pipe suitable to withstand hydrostatic pressure of 13 Kg/ cm2, from the Open well Submersible pump set to the existing common delivery line with all accessories like, elbows, tees, male threaded adapters, flanges, bottom and top stainless steel pump adaptors etc as required. | 10 | metre | 540 ₹5,400 | 540 ₹5,400 |
| 1.00 | 90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm | 10 | metre | 130 ₹1,300 | 130 ₹1,300 |
| 1.00 | 90.12.24.2:Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.4 sq mm | 9 | each | 25 ₹225 | 25 ₹225 |
| 1.00 | 1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm | 6 | metre | 110 ₹660 | 110 ₹660 |
| 1.01 | OD127618/2023-2024:Supplying and fixing 50 mm bronze globe valve in the existing UPVC column pipe line with accessories as reqd. | 2 | each | 4,180 ₹8,360 | 4,180 ₹8,360 |
| 1.01 | 90.17.14.2:Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :50mm dia | 1 | each | 5,185 ₹5,185 | 5,185 ₹5,185 |
| 1.01 | 1.10.1:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group A | 4 | point | 850 ₹3,400 | 850 ₹3,400 |
| 1.01 | 1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch | 1 | each | 100 ₹100 | 100 ₹100 |
Tender Value
Refer Docs
EMD Value
₹4,128
Closing Date
7 Nov 2023, 2:00 pmClosed
AEE
PANTHALAYANI BLOCK PANCHAYATH
PLEASE REFER BOQ
2023_LSGD_616738_1
AE/PBP/126/23-24
Open Tender
Electrical Works
180 days
PANTHALAYANI
Please refer Tender documents.
7 documents required · 7 mandatory
₹555
Yes
₹4,128
Yes
25 May 2026
27 Oct 2023
8 Nov 2023
27 Oct 2023
7 Nov 2023
27 Oct 2023
Amount
SITC of Pump set
OD127622/2023-2024:Supply, installation , testing and commissioning of open well 5 HP submersible pump set having a discharge of not less than 160 Ltr/minute at a head of 75 mtrs (Head range 50 to 90 mtrs) with suitable impeller, strainer on suction side etc suitable for operation on three phase, 415V 50 Hz AC supply in the existing open well including submersible cable joint, connection to the existing delivery line, including providing and fixing 15 mtr long 10 mm dia SS pump lifting rope with suitable clamps made out of 60 x 10 mm MS flat iron etc. complete as required. ( Make Kirlosker KU6 -508 or equivalent models of Texmo , Lubi, V gaurd, Crompton, KSB)
OD127619/2023-2024:Providing and fixing 50 mm dia. UPVC medium duty column pipe suitable to withstand hydrostatic pressure of 13 Kg/ cm2, from the Open well Submersible pump set to the existing common delivery line with all accessories like, elbows, tees, male threaded adapters, flanges, bottom and top stainless steel pump adaptors etc as required.
90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm
90.12.24.2:Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.4 sq mm
1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
OD127618/2023-2024:Supplying and fixing 50 mm bronze globe valve in the existing UPVC column pipe line with accessories as reqd.
90.17.14.2:Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :50mm dia
1.10.1:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
90.10.3.17:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )6A universal socket
90.3.20.3:Supply & installation of light fittings on TW round block <br> Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
OD127621/2023-2024:Supply, installation, testing and commissioning of 300 mm sweep, Wall fan i/c , connections using 1.5 sq.mm FR PVC insualted copper conductor 3 core cable etc. as required. Make Almonard/ Crompton Havells.
90.15.4.5:Supply Conveyance, installation, testing and commissioning of 40W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.3.18.2:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps
1.14.1:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
1.14.2:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.14.3:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
1.14.4:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 6 Sq.mm + 1 x 6 sq.mm earth wire
1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
1.32:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
2.3.1:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.<br> Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
90.14.10.4:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 25/35 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
1.17.30:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm
OD127620/2023-2024:Current sensing single phasing cum overloading cum dry running preventer Make : L& T MPR 300
90.14.24.2:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.2 KVAr, 3 phase, 440 V, delta connected standard duty Metalised Poly Propylene Capacitor, Cylinderical Type, suitable for direct connection to motors.
90.14.28.3:S & F Motor starters of the following ratingsThree phase DOL starters for 10HP motor
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5.11:Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
5.15:Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
5.13:Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
5.17:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
OD131282/2023-2024:Preparation of drawing and necessary documents Submitting to the KSEB , Getting three phase service connection, Including incidental charges, excluding statutory charges.( Below 5 KW)
90.3.18.4:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.50 mm dia with clamps made from 25 x 3 mm MS flat
SHAJI P
Bidder Name
SHAJI P
SASINDRAN E
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid