Tender Value
₹16.9 L
EMD Value
₹33,860
Closing Date
3 Apr 2025, 2:00 pmClosed
Executive Engineer ED Baramulla
Executive Engineer ED Baramulla
Improvement of HT / LT network at village Shahdara under CSR Improvement of HT / LT network at village Shahdara under CSR
2025_PDD_274025_1
EDB/125
Open Tender
Electrical Works
Turn-key
45 days
Improvement of HT / LT network at village Shahdar
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,022
Yes
Executive Engineer ED Baramulla
₹33,860
Yes
4 Apr 2025
10 Mar 2025
4 Apr 2025
10 Mar 2025
3 Apr 2025
11 Mar 2025
10 Mar 2025 - 11 Mar 2025
Amount
Supply,Testing,Loading,Transportation,Unloading, and Erection of Steel Tubular Pole, 9 Mtr. Long Pole(ST-410 SP33) with planting depth of 1/6 th of the height of the pole, (9 mtr. Long ) as per approved drawings/standards
Supply,Testing,Loading,Transportation,Unloading, and Erection of Steel Tubular Pole, 8 Mtr. Long Pole(SP15) with planting depth of 1/6 the of the height of the pole, (8 mtr. Long ) as per approved drawings/standards
Supply,Testing,Loading,Transportation,Unloading, , Laying ,Stringing, Tensioning & Binding of ACSR Conductor, (30mm2 ACSR Conductor) as per approved drawings/standards
Supply,Testing,Loading,Transportation,Unloading, , Laying ,Stringing, Tensioning & Binding of ACSR Conductor, (50mm2 ACSR Conductor) as per approved drawings/standards
Supply,Testing,Loading,Transportation,Unloading and Fixing of G.I Channel 75X40X6mm, along with suitable clamps & collars As per REC Standard
Supply,Testing,Loading,Transportation,Unloading and Fixing of G.I Channel V-X arms 75x40x6mm with Top bracket including suitable clamps/collars As per REC Standard
Supply,Testing,Loading,Transportation,Unloading and Fixing of 11KV Polymeric composite pin insulators 12kV, 5kN, lightening impulse 75kV positive and 80kV negative , creepage distance 320mm
Supply,Testing,Loading,Transportation,Unloading and Fixing of 11KV Polymeric composite disc insulators 12kV, min falling load 45kN, lightening impulse 75kV positive and 80kV negative , creepage distance 320mm
Supply,Testing,Loading,Transportation,Unloading and Fixing of 11KV isolator double break 3pole 630Amps Horizontal mounting type with earth switch
Supply,Testing,Loading,Transportation,Unloading and Fixing of Galvanised Nuts & Bolts
Supply,Testing,Loading,Transportation,Unloading and Fixing of Galvanised stay set with 50X8mm stay clamp, guy insulator (02nos), anchor plate (200X200X6)mm nut bolts, 02nos turn buckle, 1.8m long, 16mm diameter solid GS stay rod & 7/3.15mm dia GI stranded wire complete
Supply,Testing,Loading,Transportation,Unloading and Fixing of G.I LT structure mukhi type with shackles
Supply,Testing,Loading,Transportation,Unloading and Fixing of Sundry items like Aluminium lugs, Jumpers, Binding tapes etc.
Supply,Testing,Loading,Transportation,Unloading and Fixing of Spike earthing rod 20mm 2.5mtr long with G.i strip (25X3)mm
Cement bottoming of S.T poles in 1:2:4 mix 1/6th of the height of pole below the ground and 1ft above the ground cylnerical shape with circular radius 9” from the pole centre) using 40mm crushed stone aggregate mix. As per Drawing 0.48 cum/polePit =( 600x600x1600)& Tappered at the Top. (as per REC standard) for 9 MTR ST Pole
Cement bottoming of S.T poles in 1:2:4 mix 1/6th of the height of pole below the ground and 1ft above the ground cylnerical shape with circular radius 9” from the pole centre) using 40mm crushed stone aggregate mix. As per Drawing 0.40 cum/pole (Pit 600x600x1433.3 mm) for 8 MTR ST Pole
Poviding and Painting of ST Poles with one coat of red oxide and two coats of aluminum paint to give an even shade using anti corrosive paint of standard brand (Nerolac/ Asian) paints) including cost of paint along with stamping on poles showing therein name of the firm date, year of instllaiton and the debitable head etc.
Supply,Testing,Loading,Transportation,Unloading and Fixing of Danger Plate with clamps
Supply,Testing,Loading,Transportation,Unloading and Fixing of Anti climbing device with clamps
Supply,Loading,Transportation,Unloading and fixing of Sign Board (2X2 feet) along with required accessories like clamps, nuts and bolts with all details viz. Name of the Village, Name of the Work,Head,Date of Start,Date of completion, Implementing Agency(KPDCL O&M Division Baramulla), Name of the contractor.
M/S H.B.C ENGINEERING (BID ID -2353961)
CHALKOO ENGINEERING WORKS (BID ID -2353871)
MS WASEEM ENTERPRISES (BID ID -2354075)
New Real Enterprises (BID ID -2353405)
ALIF INFRAPROJECTS PVT LTD (BID ID -2353947)
MIR ELECTRICAL ENGINEERING WORKS (BID ID -2354019)
M/S WANI ELECTRICAL CONTRACTOR (BID ID -2354001)
M/S FANCY ELECTRIC AND STEEL FABRICATORS (BID ID -2353891)
stage.html
html • 0.03 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .