GE P KOCHI
GE P KOCHI NAVAL BASE KOCHI
PROVISION OF STANDBY POWER SUPPLY UPS FOR COMMUNICATION BAY AT AVIONICS WORKSHOP P16 AT NAY KOCHI
2026_MES_799795_1
8071
Open Tender
Civil Works
Item Rate
180 days
GE P Kochi
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE P Kochi
₹66,140
Yes
21 Nov 2026
21 Nov 2026
15 Dec 2026
21 Nov 2026
12 Dec 2026
5 Dec 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Supply, install, tasting and commissioning of 20 KVA online UPS for Domestic supply supply with 30 min battery backup,
(A) INPUT :-
Voltage : 440 VAC, 3 Phase 4 wire, Voltage Variation : +/-10%
Frequency : 50 Hz, Frequency Variation : +/-5%
(B) OUTPUT:-
Rating : 20 KVA / 16 KW at 0.8 p.f., Voltage : 415V AC, 3 Phase, 4 Wires ,Voltage Variation : ± 1%, Frequency : 50 Hz ± 0.1%
Waveform : Sine Wave, Total Harmonic Distortion : < 5% on linear load
Inverter Efficiency : At 100% load > 85%
Isolation Transformer : Provided
(C) PROTECTIONS:-
Rectifier : I/P AC Over voltage / under voltage
DC Over voltage, DC under Voltage, Over Current, Single Phase Failure, Reverse Phase Sequence.
Inverter : O/P Over voltage / under voltage, O/P Over load
DC Under voltage, Over Temp,Output over Frequency, Under Frequency (D) METERING :- Multiplexed LCD Display to read Following parameters with user friendly mimic drawing, Input - Voltage/Current/Frequency
DC/Battery Voltage, Output - Voltage/Current/Frequency | 2 | Each | - | - |
| 2 | Supply and fixing of 30 Nos,12 V/ 65 AH SMF VRLA Battery 30mins backup including rack and connecter for 20 KVA UPS System.
Make : Liveline/Aplab/Powerone | 2 | Each Set | - | - |
| 3 | Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded copper conductor of size 25 Sq.mm 4 core complete all as specified and directed by Engr-in-Charge. | 20 | RM | - | - |
| 4 | Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded copper conductor of size 16 Sq.mm 4 core complete all as specified and directed by Engr-in-Charge. | 50 | RM | - | - |
| 5 | Supply and fixing 440V, 16 KA Molded case circuit breaker (MCCB) of Three poles and Neutral (TPN) current carrying capacity 100AMP, in the MCCB DB Complete with connection testing and commisioning complete all as specified and directed by Engr-in-Charge. | 1 | Each | - | - |
| 6 | Supply and fixing VTPN DB 4 way suitable for MCCB 4 pole,100 Amps with connection testing and commissioning complete all as specified and directed by Engr-in-Charge. | 1 | Each | - | - |
| 7 | Supply and fixing 415V, 10KA 'D' curve miniature circuit breaker (MCB) of Three poles and current carrying capacity 40 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed by Engr-in-Charge. | 4 | Each Set | - | - |
| 8 | M &L for earthing complete with galvanised steel earth plate electrode of size 60 cm x 60 cm x 3.15 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by alternate layer of common salt and charcoal 15 cm thick, connected to and including copper earth lead 20x3 mm copper strip by means of bolts, nuts, check nuts and washers of galvenised iron or steel and earth strip protected by GI pipe 40 mm dia light grade and connected from earth plate electrode to main switch board/ earthing test point or upto 7.5 mtr whichever is less including watering arrangement using 20mm GI pipe light grade, MS funnel with wire mesh, PCC chamber pit in PCC 1:3:6 type C-1, 40 mm thick pre-cast RCC cover re-inforced with 8mm dia TMT bars @ 10cm C/C on both sides and handle, excavation and earth work in any type of soil and removal upto 50 mtr complete all as specified and shown in electrical plate No 03 of SSR Part-I, all as specified and directed including testing on completion. | 2 | Each Set | - | - |
| 9 | Earth continuity conductor or main earthing lead on wall of height up to 40 meter / Ceiling floor by soldering and fixing on porcelain saddles with 20x3 Copper Strip complete all as specified and directed as required | 30 | RM | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.43 MB
Tender.pdf
Tender Documents • 1.02 MB
BOQ_897368.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .