Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.4 CrAccepted-AOC | ₹21.4 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹22.6 CrRejected-AOC | ₹22.6 Cr | L2 | Rejected-AOC L2 |
Tender Value
₹19.4 Cr
EMD Value
₹5 L
Closing Date
14 Aug 2023, 11:00 amClosed
Superintending Engineer
Office of the Superintending Engineer, Public Health Circle, Kottayam, Kerala Water Authority
Jal Jeevan Mission (JJM)_Phase IV _WSS to Kidangoor, Kadaplamattom and Marangattupally Panchayaths_Design and Construction of 10 MLD WTP, Source improvement and allied works _General Civil Work
2023_KWA_589619_1
WRD/KWA-CE(SR)/ TR/13162/2022_5_1_1/1
Open Tender
Civil Works - Water Works
600 days
kidangoor
Please refer Tender documents.
8 documents required · 8 mandatory
₹16,540
₹5 L
O/o the SE, PHC, KWA Kottayam
20 Feb 2024
22 Jul 2023
16 Aug 2023
22 Jul 2023
14 Aug 2023
22 Jul 2023
22 Jul 2023 - 27 Jul 2023
27 Jul 2023
Amount
CIVIL and Structural Design Drawing of 10 MLD WTP and Components
OD190197/2022-2023:Design of structural drawings for the 10 MLD WTP (lamella type chlarifier) & 4 LL OHSR , verification, submission of the design drawings, approval of the design drawings from WASCON,& structural design works as directed by the Engineer in charge for the satisfactory completion of the work.
Appendix D - Construction of 10 MLD WTP -Part I- Aerator
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
2.7.1:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
4.1.6:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
5.33.1:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level
5.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
OD172945/2022-2023:Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work,using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering,finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.All works above Plinth Beam uo to Floor Five level (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately)-
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
OD172946/2022-2023:Extra for shuttering in circular work for Suspended floor & roof (20% of respective centering and shuttering items as per 5.9.14
OD172947/2022-2023:Extra for shuttering in circular work for column (20% of respective centering and shuttering items as per 5.9.14
5.11.1:Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
18.30.10:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:450 mm diameter pipe
18.69.1:Providing and laying D.I Specials of Class K - 12 suitable for mechanical jointing as per IS : 9523 :Upto 600 mm dia
18.72.22:Providing and laying S & S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329:450 mm dia Ductile Iron Class K- 9 pipes
Appendix D - Construction of 10 MLD WTP -Part II -Raw water channel and clarified water channel
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.6:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
5.33.1:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level
5.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
OD173066/2022-2023:Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work,using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering,finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.All works above Plinth Beam uo to Floor Five level (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately)-
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
Appendix D - Construction of 10 MLD WTP -Part III -Lamellar Sedimentation tank
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
4.1.6:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
OD173067/2022-2023:Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work,using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering,finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.All works below plinth level (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately)-
OD173068/2022-2023:Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work,using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering,finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.All works above Plinth Beam uo to Floor Five level (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately)-
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
10.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes
13.48.3:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
5.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
OD97753/2023-2024:Providing and fixing 304 stainless steel lamella plates and support structures for water.-treatment, Inclined Chanel support ,top cover,side support,weir for water out flow,SS 304 nuts and bolts, welding etc<br>settlers and side supporting cover are fabricated using high graded stainless steel SS 304 suitable for use in the<br>water and waste treatment plants to improve the quantity and quality of water production.with all required<br>accessories-(effective size of plate length-2.1m,width-1.2 m,thickness-0.7 mm. or suitable ) as per the direction of departmental<br>officers.<br>304 stainless steel lamella plates and support structures for water treatment plant.
Appendix D - Construction of 10 MLD WTP -Part IV -Chemical house
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
4.1.6:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
5.33.1:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
5.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.16.1:6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.83.2:Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats
10.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover
21.10:Providing and fixing double glazed hermetically sealed glazing in aluminium window, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant ) etc. as per specifications, drawings and direction of Engineer-in-Charge complete.
9.48.2:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc
Appendix D - Construction of 10 MLD WTP -Part V -Alum and lime solution tank room
5.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
OD173071/2022-2023:Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work,using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering,finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.All works above Plinth Beam uo to Floor Five level (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately)-
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.16.1:6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.83.2:Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats
11.37:Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.
11.41.3:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 800x 800 mm
21.10:Providing and fixing double glazed hermetically sealed glazing in aluminium window, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant ) etc. as per specifications, drawings and direction of Engineer-in-Charge complete.
21.3.3:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 8 mm thickness
Appendix D - Construction of 10 MLD WTP -Part VI -FILTER HOUSE
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
OD173072/2022-2023:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed All kinds of soil of depth 1.5 m to 3.0 m
4.1.6:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
5.40.1:Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using fly ash and cement content as per approved design mix, and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer- in charge. Note:- (1) Cement content considered in this item is @330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately. (2) Fly ash conforming to grade I of IS:3812 (Part-1) only be used as part replacement of OPC as per IS: 456. Uniform blending with cement to be ensured in accordance with clause 5.2 and 5.2.1 of IS: 456-2000 in the items of BMC and RMC.All works up to Plinth level
5.40.2:Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using fly ash and cement content as per approved design mix, and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer- in charge. Note:- (1) Cement content considered in this item is @330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately. (2) Fly ash conforming to grade I of IS:3812 (Part-1) only be used as part replacement of OPC as per IS: 456. Uniform blending with cement to be ensured in accordance with clause 5.2 and 5.2.1 of IS: 456-2000 in the items of BMC and RMC.All works above plinth & up to floor V level
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.16.1:6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.83.2:Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats
21.10:Providing and fixing double glazed hermetically sealed glazing in aluminium window, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant ) etc. as per specifications, drawings and direction of Engineer-in-Charge complete.
10.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover
9.48.2:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc
Appendix D - Construction of 10 MLD WTP -Part VII -FILTER BOX
OD173073/2022-2023:Providing and laying in position machine batched and machine mixed design mix M-30 grade<br>cement concrete for reinforced cement concrete work,using cement content as per approved design mix, including<br>pumping of concrete to site of laying but excluding the cost of centering, shuttering,finishing and reinforcement,<br>including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve<br>workability without impairing strength and durability as per direction of Engineer-in-charge.All works above plinth level<br>(Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is<br>payable/recoverable separately)-
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
11.37:Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.
100.55.1:Supplying of 2 to 6 mm and 6 to 12 mm size fine pebble (pebbles shall be hard, clean, free from clay, dust and other impurities), stacking in standard heaps for measurement including cost, conveyance up to 5 km and labour charges for stacking, spreading, testing and as per the directions of the department officers etc. complete as per CPHEEO specifications.
100.55.2:Supplying of 12 to 20mm size pebble (pebbles shall be hard, clean, free from clay, dust and other impurities), stacking in standard heaps for measurement including cost, conveyance up to 5km and labour charges for stacking, spreading, testing and as per the directions of the department officers etc complete and as per CPHEEO specification.
100.55.3:Supplying of 20 to 40 mm pebble (pebbles shall be hard, clean, free from clay, dust and other impurities), stacking in standard heaps for measurement including cost, conveyance up to 5 km and labour charges for stacking, spreading, testing and as per directions of the department officers etc. complete and as per CPHEEO specification.
100.55.4:Supplying and stacking for measurement of filter sand having effective size 0.45 to 0.70 mm and uniformity coefficient 1.30 to 1.7, of specific gravity in the range of 2.55 - 2.65 and hard and clean, free from clay, dust and other impurities including cost of materials, labour charges and conveyance of materials up to 5 km and as per the directions of the department officers etc. complete and as per CPHEEO specification.
Appendix D - Construction of 10 MLD WTP -Part VIII - CLEAR WATER CHANNEL
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
OD172949/2022-2023:Providing and laying in position machine batched and machine mixed design mix M-30 grade<br>cement concrete for reinforced cement concrete work,using cement content as per approved design mix, including<br>pumping of concrete to site of laying but excluding the cost of centering, shuttering,finishing and reinforcement,<br>including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve<br>workability without impairing strength and durability as per direction of Engineer-in-charge.All works below plinth level<br>(Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is<br>payable/recoverable separately)-
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
Appendix D - Construction of 10 MLD WTP -Part IX-CLEAR WATER SUMP
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
OD173074/2022-2023:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed All kinds of soil of depth 1.5 m to 3.0 m
4.1.6:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
OD173075/2022-2023:Providing and laying in position machine batched and machine mixed design mix M-30 grade<br>cement concrete for reinforced cement concrete work,using cement content as per approved design mix, including<br>pumping of concrete to site of laying but excluding the cost of centering, shuttering,finishing and reinforcement,<br>including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve<br>workability without impairing strength and durability as per direction of Engineer-in-charge.All works below plinth level<br>(Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is<br>payable/recoverable separately)-
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
10.25.2:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
OD173076/2022-2023:Supplying,Conveying and Fixing Water level indicator with brass ball and all accessories.-<br>including labour charges
OD173077/2022-2023:550 x 550 mm CI MH cover with frame heavy(0.75 x 0.75)
OD173078/2022-2023:Placing cover slab on the valve chamber safely in position etc complete
Appendix D - Construction of 10 MLD WTP -Part X -CLEAR WATER PUMP HOUSE
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
2.9.1:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock
4.1.6:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
5.37.2:Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in -charge. Note:- Cement content considered in this item is @330 kg/cum. Excess /less cement used as per design mix is payable/recoverable separately.All work above plinth level upto floor V level
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.6.1:20 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand)
11.41.1:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 500x500 mm.
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.83.2:Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats
21.10:Providing and fixing double glazed hermetically sealed glazing in aluminium window, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant ) etc. as per specifications, drawings and direction of Engineer-in-Charge complete.
10.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover
9.48.2:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc
10.2:Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Appendix D - Construction of 10 MLD WTP -Part XI -CHLORINE ROOM
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
4.1.4:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 )1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size)
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
5.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.16.1:6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
11.5:62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufactures specification. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.83.1:Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.One coat
21.10:Providing and fixing double glazed hermetically sealed glazing in aluminium window, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant ) etc. as per specifications, drawings and direction of Engineer-in-Charge complete.
10.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover
Appendix D - Construction of 10 MLD WTP -Part XII -BLOW OPERATORS OFFICE ,LAB ROOM ETC
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
OD172938/2022-2023:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed All kinds of soil of depth 1.5 m to 3.0 m
4.1.4:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 )1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size)
5.40.1:Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using fly ash and cement content as per approved design mix, and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer- in charge. Note:- (1) Cement content considered in this item is @330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately. (2) Fly ash conforming to grade I of IS:3812 (Part-1) only be used as part replacement of OPC as per IS: 456. Uniform blending with cement to be ensured in accordance with clause 5.2 and 5.2.1 of IS: 456-2000 in the items of BMC and RMC.All works up to Plinth level
5.40.2:Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using fly ash and cement content as per approved design mix, and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer- in charge. Note:- (1) Cement content considered in this item is @330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately. (2) Fly ash conforming to grade I of IS:3812 (Part-1) only be used as part replacement of OPC as per IS: 456. Uniform blending with cement to be ensured in accordance with clause 5.2 and 5.2.1 of IS: 456-2000 in the items of BMC and RMC.All works above plinth & up to floor V level
5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.16.1:6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.83.2:Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats
11.39:Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS: 15622, of approved make in colours White, Ivory, Grey, fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 Coarse sand), including grouting the joints with white cement and matching pigments etc., complete.
11.41.3:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 800x 800 mm
17.3.1:Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid
21.10:Providing and fixing double glazed hermetically sealed glazing in aluminium window, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant ) etc. as per specifications, drawings and direction of Engineer-in-Charge complete.
21.3.3:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 8 mm thickness
10.16.1:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
12.50:Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
12.51.1:Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete:Ridges plain (500-600 mm)
12.51.2:Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete:Flashings / Aprons (Upto 600 mm)
12.51.3:Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete:North light curves
12.51.6:Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete:Gutter (600 mm over all girth)
Appendix D - Construction of 10 MLD WTP -Part XIII -BACK WASH WATER TANK
OD172989/2022-2023:Providing and laying in position machine batched and machine mixed design mix M-30 grade<br>cement concrete for reinforced cement concrete work,using cement content as per approved design mix, including<br>pumping of concrete to site of laying but excluding the cost of centering, shuttering,finishing and reinforcement,<br>including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve<br>workability without impairing strength and durability as per direction of Engineer-in-charge.All works above plinth level<br>(Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is<br>payable/recoverable separately)-
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.83.2:Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats
10.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes
OD172990/2022-2023:Supplying,Conveying and Fixing Water level indicator in the OHSR made of Aluminium with powder coated having marked properly including all accessories etc.
OD172991/2022-2023:Placing Cover slab on the valve chamber safely in position etc complete
OD172992/2022-2023:M H cover with frame (medium duty)
Appendix D - Construction of 10 MLD WTP -Part XIV -LOBBY AND STAIR
5.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.9.7:Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)
13.1.2:12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).
13.48.1:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm
13.83.2:Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats
10.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes
Appendix D - Construction of 10 MLD WTP -Part XV -COST OF CONNECTION WORKS OF VARIOUS COMPONENTS OF WTP
OD172939/2022-2023:Providing conveying and fixing the same in position etc required connection components required for the working for WTP as per design , required thickness size and quality such as pipe ,bend and other fittings and other implements as the direction of department officials
Appendix D - Construction of 10 MLD WTP -Part XVI -LAND SCAPPING AND SOLAR
OD172940/2022-2023:Weeding out of lawn by removal of all weeds and other wild growth with<br>roots by forking including disposal of garden rubbish with all loads and lifts<br>complete if top dressing required paid separately (cost of manure, sludge<br>or extra good earth to be paid for separately) as per direction and satisfaction<br>of officer in charge
30.2.15.1:Half brick circular tree guard in bricks, internal diameter 1.25 metre and height 1.2 metre above ground and 0.20 m below ground, bottom two courses laid dry and top three courses in cement mortar 1:6 (1 cement : 6 fine sand) and the intermediate courses being in dry honey comb masonry as per design complete:With common burnt clay F.P.S. (non modular) bricks of class designation 5
30.2.17.1:Making tree guard 53 cm dia and 1.3 m high as per design from empty coal tar drums, supplied free by the department, including providing and fixing 2 nos M.S. sheet rings 50 x 0.5 mm fixed with rivets complete in all respects including painting inside and outside of tree guard with:A coat of coal tar
30.2.20:Filling mixture of earth and sludge or manure in the desired proportion in trenches, flooding with water and leveling (cost of supplying earth and sludge or manure and mixing excluded).
30.2.57.1:Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unsaverieable material?s as per direction of officer in charge (excluding cast of plant & water )Cost of plantation per trees plants (for 100 nos.=427.45/100)
30.2.58:Providing and fixing of Tuflex Garden fencing Hexagonal net/or equivalent of green colour having contents Weight grams/sqm. 510 (+/- 8%) in width of 60 cm. with bamboo of 90 cm. length and 18-20 girth. The bamboo should be painted with green colour paint of approved brand and manufacture two or more coats and fixed 30 cm. below ground level and 60 cm. above ground level at a distance of 1.50 mtrs. The net and bamboo should be binded with 2 mm. G.I. Wire at equal distance of three places in each bamboo complete and as per direction of Engineer-in-charge.
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
OD97351/2023-2024:Supply installation testing, trial run and commissioning of 60kWp solar on grid plant with advanced Mono Perc Half Cut Solar panels, Structures to mount panels, DC cables and connectors DC junction Box, . AC junction Box , In and out meters,solar meter with Box, AC cables, Link/CB, TPN Box and all other electrical and mechanical accessories complete a sper the direction of departmental officers and in accordance with Inspectorate standards. All paperwork, statutory fees and allied works with the Electrical inspectorate and KSEB Limited for the approval and to be got approved by Electrical Inspectorate and KSEB Limited
Appendix D - Construction of 10 MLD WTP -Part XVII - OTHER MISCELLANEOUS ITEMS
Appendix D - Construction of 10 MLD WTP -Part XVIII -CHAMBER
2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
5.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.44.1:Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)
13.51.2:Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces:Two coats
Appendix D - Construction of 10 MLD WTP -Part XIX - Sludge valve chamber
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
Appendix D - Construction of 10 MLD WTP -Part XX - universal ultrasonic flow meter
OD172941/2022-2023:supply and fixing reputed brand universal ultrasonic flow meter to pumping main
Appendix D: Construction of 10 MLD WTP - Part XXII -RECYCLING PLANT
OD185750/2022-2023:Construction of recycling plant suitable for 10 MLD WTP including all pipes, piping arrangements, pump sets including stand-bye and accessories which includes (1)Roughing filtersystem;(2)Wash water collection tank;(3)Construction of valve chambers;(4)Effluent collectiontank;(5)Sludge collection tank;(5)Sludge lagoon;(6)Filtered water collection well cum soakpit;(7)Channel to collecting chambers(2nos);(8)pumping main from wash water collection tank to roughing filter system and to the aerator;(9)pumping main from sludge collection tank tosludge lagoon;(10)Valve chambers for the operation ;(11) other items for the satisfactorycompletion of the recycling plant etc .Labour
Appendix D: Construction of 10 MLD WTP - Part XXIII - Supply and Installation Lab Equipments
OD186277/2022-2023:Supply, Installation and setting up of Desktop computer system(Lenovo/Dell/HP) having Intel corei3-&lt;br&gt;10th Gen (6MB Cache, 4Cores, 3.60 GHz up to 4.20 GHz), 8GB DDR4, 1TB HDD/500GB SSD, DVDRW,Integrated graphics, Built-in WiFi, 22&quot; (or nearest) FHD Display,Serial port, Bluetooth, Windows10,&lt;br&gt;MS Office, USB Key board &amp; Mouse, 3 year On site warranty. Inclusive of600VA V-Guard UPS &amp; Canon&lt;br&gt;G3000 Multifunction Color Printer
OD186278/2022-2023:Supply, installation and commissioning of Digital pH Meter (Range 0-14 pH, Resolution0.01pH)with&lt;br&gt;standard glass and reference electrode withstand.
OD186772/2022-2023:Supply, Installing and testing best quality ISI Jar test apparatus with Turbidity meter with all required accessories
Appendix D: Construction of 10 MLD WTP - Part XXV -3 year maintenance of 10 MLD Plant
OD97522/2023-2024:Operator
OD97520/2023-2024:Shift Assistant
OD97521/2023-2024:sweeper-part time
OD185787/2022-2023:Supply of liquid chlorine filled in Tonner Cylinders (or as percondition)
OD185788/2022-2023:Labour and material (all costs towards labour, spares, consumables, chemicals, repairs andrenewalsshall be on to the account of the contractor)cost for maintaining inside area of WTP compoundsuch as roads , Landscaping area, gardens,water lines , electrical items,Cost of manure forgardening, hire charges for gardening tools , diesel operated lawn mover, including cost ofdiesel etc as per the direction of departmental officers
OD185789/2022-2023:Supply and delivery of Alum (or as per condition)
OD185790/2022-2023::cost for safety equipment such as helmets, safety shoes, jackets, safetybelts, self containingbreathing apparatus, refilling of fire extinguisher, safety masks, first aid kits,Tools and Plants required for the day today operation of the Plant and Equipment etc complete.as per thedirection of departmental officers..(all coststowards labour, spares, consumables, chemicals, repairs and renewalsshall be on to the account of the contractor)-One year
OD185791/2022-2023:Labour and material (all costs towards labour, spares, consumables,chemicals, repairs and renewalsshall be on to the account of the contractor)Charges for Periodical Maintenance, Repairs of aerator,raw water Chanel,clear water channels,flax mixer,clarifiers, filter bed building .chemical room building ,lamella Clarifiers, leading Channels and other all units in the 10 MLD WTP and connectedstructures,compound wall, including door, windows,ventilators, handrails ,lamella plate,( all components in the civil strutcher ) etc completeto the satisfaction of the KWA Engineer in-charge( If any found to bedefective either due to manufacture or due to unsatisfactorymaintenance, the same should be replaced by the contractor at hiscost.).Sump,Back wash tank-minimum once in 3 months or( asinstructed by KWA engineer).sludge lagoon ,recycling unit -minimum
OD185796/2022-2023:Supply and delivery of Hydrated lime as per specification at dosage(oras per condition)
Electrification work
OD91585/2023-2024:OD2911/2023-2024 supply, installation, testing, and commissioning of electrical all items inconnection with WTP and recycliing plant like wiring materials, (TOD Meter, CTPT Units, Protective equipments,Cable laying works and its connections, Yard structures, All electrical Panel Boards, 11KV sub station works, RMU works, vacuum circuit breaker works, indoor Transformer works(HT & LT),cubicle works, earthing ,Panel board works, UG cable works, APFC works, Capacitor panel works, HTpanel boards,LT panel board works, Lead acid cellbattery charger, automatic twin battery charger works, safety works & items approved by Kerala Electrical Inspectorate , , CCTV works for all the areas in the WTP & outside(8Nos 5Mp camera woth all connected items one moth back up ),cables from main panel board to WTP and connected components, and all other electrical works for the satisfactory completion of the electrical works. All the other cable works related to Electrical works, Supply and works of required Earthing, supplying and laying checcered plates Supply, installation, testing, and commissioning of electrical all items in connection with WTP and recycling plants like wiring materials, , ,wiring with suitable quality wires with sufficient number of Light(36 w led tube lights evenly fitted as minimum Two numbers per 100 sqfeet so that minimum two lights in a room), Fan(Minimum one number per 100 sq feet so that minimum one Fan in a room), Minimum three plug pints of light and one for Power per 100 sqfeet and other necessary switches and plug points of suitable ratings wherever necessary as per direction of departmental officers subject to the condition that minimum 1 fan , 2 led 36 w lights, 2 plug points, and one power plug in each room and as per design of WTP for the satisfactory completion of the work, Yard lighting works as directed by departmental officers, Providing and fixing all fixtures including Ceiling Fan, Exhaust Fan, Pedestal Fan, wall mounted Fan and LED Lights of good quality wherever necessary and all other electrical works ,Supply and installation of MCBs wherever required for lighting and power loads, CCTV works for all the areas in the WTP & outside(8Nos 5Mp camera with all connected items one month back up ),supply and laying cables from main panel board to WTP with adequate sizes and connected components and in accordance with safety standards , Required structures, supply and installation of all protective equipments and all safety works and items as per the standards of Electrical Inspectorate, supply an installation of lightning arrester as per IS specification, all safety equipment etc complete as per latest IE rules as per directions of departmental officers and items approved by Kerala Electrical Inspectorate, Drawings for the electrical inspectorate.(All the work must be in accordance with Electrical Inspectorate standards.) and all other electrical works for the satisfactory completion of the same .All the other cable works related to Electrical works, Supply and works of required Earthing and all related mechanical works . All paper and allied works with necessary statutory fees at Electrical inspectorate and KSEB Limited for approval and to be got approved by Electrical Inspectorate and connection from KSEBL. All the approved diagrams and reciepts from KSEBL and Inspectorate in original must be submitted to plant in charge after successful commissioning of the electrical items (All the work must be in accordance with Electrical Inspectorate standards.)
Appendix D: Construction of 10 MLD WTP - Part XXI - Mechanical components of Water Treatment Plant
OD97516/2023-2024:Supply, installation, Testing, Trial run and commissioning of All Mechanical components of the Water Treatment Plant and recycling plant and pumphouse(Sump and OH if necessary ) including pumps, motor, (for recycling tank and back wash also as per design if necessary) ,Water level indicator for Backwash tank,sump,OH tank,Lightning arrestors valves filter bed arrangements, gantry cranes, crane for chlorine tonner, rolling shutters, grills, ladders, DI K9 Pipes used for Interconnecting components in connection with WTP and recycling plant (except Raw water and clear water pump sets), handrails, protection works, pipeline works between all components such as blower unit, recycling plant, backwash tank etc all work in the WTP.blower units-(Use all DIK9 pipe), bridges and racking mechanics, under drains system, lateral pipes for air and water etc chlorine tonner with lifting arrangements; and filled chlorine tonner from TCL(4Nos)with all statutory approval. , supply, providing testing and commissioning of chlorinator unit with chlorine mixing pump and all connecting accessories(capacity of chlorinator for 100% over load-pennwalt type backwash units all connected works for the satisfactory completion of works as per the direction of departmental officers.
Appendix G - Electrical substation at TP
OD172879/2022-2023:od145687/2021_2022 Supply and Laying of 11kV, 3C x 185 sq.mm XLPE power cable in duct / trench etc. as complying to specifications and standards
OD172880/2022-2023:od145688/2021_2022 Supply and Fixing of end terminations for 11kV, 3C x 150 sq.mm.
OD172881/2022-2023:od145690/2021_2022 "Supply Installation, testing and commissioning of unitised substation with HT metering equipments, CTs, PT of class 0.2S, TOD meter class0.2S and with 500KVA, 11KV/433V, 3-phase, 50Hz, Cast resin dry type indoor Transformer with all standard accessories linked with a 12kV Load break SFU with HRC fuse shunt trip, remote tripping mechanism, seal off bushings etc. including all control wiring, testing of relays/CTs etc. installation shall be done asper standards and as per CEA regulations applicable.
OD172882/2022-2023:Supply, Design, Fabrication, Erection, Testing and Commissioning of following cubicle type, fully compartmentalised LT switchboards dust tight and vermin proof, fabricated out of 14/16 SWG CRCA sheet, chemically treated and powder coatd with 2 coats approved shade. The Panel boards shall have an IP rating of IP 54. The switchboards should have a set of suitably rated TPN Aluminium busbars with the specified current and fault level, insulated with heat shrinkable, color coded PVC sleeves and supported using DMC/SMC pillar or Finger type busbar supports.The design shall be as per the standards of the State Electrical Inspectorate. All indication lamps should be LED type, all MCCBs shall be with rotary operating handle.
OD172883/2022-2023:Supply and fitting 3Ph 6way DB consisting 40A 4Pole isolater 40A 4p30ma Elcb ,10A Sp mcb,6A sp McB
OD172884/2022-2023:-Supply, Design, Fabrication, Erection, Testing and Commissioning of following cubicle type, fully compartmentalised LT switchboards dust tight and vermin proof
OD172885/2022-2023:SSB - 2 -Supply, Design, Fabrication, Erection, Testing and Commissioning of following cubicle type, fully compartmentalised LT switchboards dust tight and vermin proof, fabricated out of 14/16 SWG CRCA sheet, chemically treated and powder coatd with 2 coats approved shade. The Panel boards shall have an IP rating of IP 54. The switchboards should have a set of suitably rated TPN Aluminium busbars with the specified current and fault level, insulated with heat shrinkable, color coded PVC sleeves and supported using DMC/SMC pillar or Finger type busbar supports.The design shall be as per the standards of the State Electrical Inspectorate. All indication lamps should be LED type, all MCCBs shall be with rotary operating handle.Fabricated out of 14 SWG CRCA sheet.<br>Top/bottom cable entry for incoming and outgoing feeders. 1)Busbar of electrolytic Al. 250A - 1set <br>2) Incomer:- 250A TPN Isolator - 1 no. <br>3) Meters and Indications: <br>VAF +PF meter with CTs and mcb/fuse protection - 1 set <br>Red, Yellow and Blue LED Indication lamps 1 Set.<br>4) Outgoings: <br>a) 100A, 25kA TPN MCCB Setting 63-80A- 6No.<br>b) 100A, 25kA TPN MCCB Setting 50-63- 1No. c) 100A, 25kA TPN MCCB Setting 25-32- 4No.
OD172886/2022-2023:DISTRIBUTION BOARDS - Supply installation testing and comissioning of reputed make 4way vertical distribution boards consisting of 100A Isolator as incommer and suitably rated TP MCBs of rating 16A to 32A, 4nos as per standards. - for VDB L1& L2,
OD172887/2022-2023:DISTRIBUTION BOARDS - Supply installation testing and comissioning of reputed make 8way vertical distribution boards consisting of 100A Isolator as incommer and suitably rated TP MCBs of rating 16A to 32A, 8nos as per standards. - for VDB P1& P2,
OD172888/2022-2023:DISTRIBUTION BOARDS - Supply installation testing and comissioning of reputed make TPN 6way distribution board consisting of 32A/30mA 4P ELMCB as incommer and18 nos of 6A SP MCBs of as per standars. - for LDB1 & 2
OD172889/2022-2023:DISTRIBUTION BOARDS - Supply installation testing and comissioning locable on/off push button of reputed make for emergency trip of USS
OD172890/2022-2023:DISTRIBUTION BOARDS - Supply installation testing and comissioning 125A TP Isolators of reputed make with suitable enclosure installed within 3mtre as local isolstion for equipments (30HP, 20HP motors)
OD172891/2022-2023:DISTRIBUTION BOARDS - Supply installation testing and comissioning 63A TP Isolators of reputed make with suitable enclosure installed within 3mtre as local isolstion for equipments (10 HP)
OD172892/2022-2023:DISTRIBUTION BOARDS - Supply installation testing and comissioning 10-32A TP MCB Isolators of reputed make with suitable enclosure installed within 3mtre as local isolstion for equipments (1HP,to 5HP motors)
OD172893/2022-2023:MV CABLE SUPPLY & LAYING - Supply and Laying reputed make 3.5x 400 sqmm 1.1kV grade armoured aluminum conductor XLPE cable as per standards (USS to MSB, MSB to SSB1,
OD172894/2022-2023:MV CABLE SUPPLY & LAYING - Supply and Laying reputed make 3.5x 240 sqmm 1.1kV grade armoured aluminum conductor XLPE cable as per standards ( MSB to SSB2,)
OD172895/2022-2023:MV CABLE SUPPLY & LAYING - Supply and Laying reputed make 3.5x185 sqmm 1kV grade armoured aluminum conductor XLPE cable as per standards (SSB 1 to 180Hp Motors 1&2 and APFC
OD172896/2022-2023:MV CABLE SUPPLY & LAYING - Supply and Laying reputed make 3.5x 95 sqmm 1.1kV grade armoured aluminum conductor XLPE cable as per standards SSB 1 to 75Hp Motors
OD172897/2022-2023:MV CABLE SUPPLY & LAYING - Supply and Laying reputed make 3.5x 35 sqmm 1.1kV grade armoured aluminum conductor XLPE cable as per standards SSB 1 to VDB L1,SSB2 to switchboard (existing ) ,SSb 2VDB P1,P2 and L2
OD172898/2022-2023:MV CABLE SUPPLY & LAYING - Supply and Laying reputed make 3x 16 sqmm 1kV grade armoured aluminum conductor XLPE cable as per standards(SSB2 to backwash 20Hp Motor )
OD172899/2022-2023:MV CABLE SUPPLY & LAYING - Supply and Laying reputed make 4x 10 sqmm 1.1kV grade armoured aluminum conductor XLPE cable as per standards (VDBs to LDBs)
OD172900/2022-2023:MV CABLE SUPPLY & LAYING - Supply and Laying reputed make 3x 6 sqmm 1.1kV grade armoured aluminum conductor XLPE cable as per standards( SSB2 to 10HP motor and 5Hp motor
OD172901/2022-2023:MV CABLE SUPPLY & LAYING - Supply and Laying reputed make 3x 4 sqmm 1.1kV grade armoured aluminum conductor XLPE cable as per standards( VDB Power to small ranges motors
OD172902/2022-2023:MV CABLE SUPPLY & LAYING - Supply and Laying reputed make 2x 2.5 sqmm 1.1kV grade armoured copper conductor XLPE cable as per standards (Apfc,remote control, neutrl CT to EFR)
OD172903/2022-2023:End Termination - Supply and providing of end termination for 3.5x 400 sqmm 1.1kV grade armoured aluminum conductor XLPE cable as per standards
OD172904/2022-2023:End Termination - Supply and providing of end termination for 3.5x240 sqmm 1.1kV grade armoured aluminum conductor XLPE cable as per standards
OD172905/2022-2023:End Termination - Supply and providing of end termination for 3.5x 185 sqmm 1.1kV grade armoured aluminum conductor XLPE cable as per standards
OD172906/2022-2023:End Termination - Supply and Laying reputed make 3.5x 95 sqmm 1.1kV grade armoured aluminum conductor XLPE cable as per standards
OD172907/2022-2023:End Termination - Supply and providing of end termination for 3.5x35 sqmm 1.1kV grade armoured aluminum conductor XLPE cable as per standards
OD172908/2022-2023:End Termination - Supply and providing of end termination for 3x 16 sqmm 1kV grade armoured aluminum conductor XLPE cable as per standards
OD172909/2022-2023:End Termination - Supply and providing of end termination for 3x 10 sqmm 1.1kV grade armoured aluminum conductor XLPE cable as per standards
OD172910/2022-2023:End Termination - Supply and providing of end termination for 4x 6 sqmm 1.1kV grade armoured aluminum conductor XLPE cable as per standards
OD172911/2022-2023:End Termination - Supply and providing of end termination for 4x 4 sqmm 1.1kV grade armoured aluminum conductor XLPE cable as per standards
OD172912/2022-2023:End Termination - Supply and providing of end termination for 2x 2.5 sqmm 1.1kV grade armoured copper conductor XLPE cable as per standards
OD172913/2022-2023:EARTHING -Supplyand providing of standard plate earthing using 1200x1200x12mm CI plate electrode with all other earthing materials and watering and inspection chamber etc as per standards of BS 3048 and CEA regulations
OD172914/2022-2023:EARTHING - supply and laying 50 x6mm hot dip GI strip for earthing the system
OD172915/2022-2023:EARTHING - supply and laying 25x6mm GI hot dip strips for Panel earthing
OD172916/2022-2023:Supply and fitting gland earthing clips 25x3 CU
OD172917/2022-2023:EARTHING - supply and laying of SWG no.6 copper wire for DG set and equipment earthing
OD172918/2022-2023:EARTHING - supply and laying of SWG no.10 copper wire for equipment earthing
OD172919/2022-2023:Fabricating supplying and erecting cable tray by using suitable size angle iron, flats, squares etc as required
OD172920/2022-2023:SAFETY EQUIPMENTS - Supply and fixing 6kg DCP fire extinguisher
OD172921/2022-2023:SAFETY EQUIPMENTS - Supply and fixing fire bucket with stand
OD172922/2022-2023:SAFETY EQUIPMENTS - Supply and fixing Electrical grade 11KV synthetic mat
OD172923/2022-2023:SAFETY EQUIPMENTS - Supply and fixing Electrical grade 1KV synthetic mat
OD172924/2022-2023:Prepration of drawings, submitting to electrical inspectorate getting initial approval submitting completion report laisoning, conducting inspection and getting final Sanction
OD172925/2022-2023:SAFETY EQUIPMENTS - Supply and fixing first aid box
OD172926/2022-2023:SAFETY EQUIPMENTS - Supply and fixing first aid chart
OD172927/2022-2023:Prepration of completion report and annexures, submitting to KSEB conducting inspection etc complete - Laisoning charges
Appendix E -RENOVATION OF INTAKE WELL AT KAVALIPUZHA IN KIDANGOOR INCLUDING LEADING PIPE AND SIDE PROTECTION
100.98.147:Supply of HDPE Pipe PE 100 (IS 4984/1995), 8kg, 450mm Outer Dia.
OD172872/2022-2023:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 450mm (with gear assembly)
OD172873/2022-2023:Engaging labour for clearing and leveing the bank of river
OD172874/2022-2023:Trenching the river bed in liquid mud and ordinary soil for laying H D P E pipes upto a maximum depth of 5.5M below water level using diving set and air compressor or using any other scientific method, stacking the excavated soil at convenient place and refilling the trenches after laying pipes includingall labour and hire for diving et, air compressor, country boat and all other appliances & equipments, maintaining the depth of trenches till laying pipes etc. is completed.
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
OD172875/2022-2023:Earthwork excavation in or under water do ..... do
100.10.14:Laying HDPE pipes (IS : 4984) on land portion including conveying within initial lead and aligning the pipes, electro-fusion welding using automatic or semi-automatic electrofusion machines, testing the pipeline thus fabricated to suit the hydraulic working pressure and after testing, aligning the pipeline, lowering the pipe in position into the trenches already made, testing the line to suitable pressure with potable water before back filling and levelling the trenches including all labour charge, hire for appliances etc., complete but excluding cost of pipe and fittings: 450mm Nominal Outside Diameter Pipes.
OD172876/2022-2023:Casting R.C.C.sleeves as per design with C C 1:1.5:3 using 20mm broken stone and supplying suitable
OD172877/2022-2023:Jointing 450mm HDPE pipes and specials already laid to lines and levels in the trenches to withstand the required test pressure by Electro-fusion welding using automatic or semi automatic electro fusion machines, including the conveyance of jointing materials within initial lead etc.complete to make a water tight joint capable to withstand the required pressure including cost of Electro fusion coupler.
OD172878/2022-2023:Jointing 450mm HDPE pipe ends to the pipes of equal dia. by Jointing with mechanical joint specially maded laid to lines and levels in the trenches etc.including the conveyance of jointing materials within initial lead etc.complete to make a water tight joint capable to withstand the required pressure. Including cost of pipe end, with standard bolt holes etc. complete.
Appendix A - Supply ,Installation and commissioning of Pump sets for KIDANGOOR PANCHAYATH
OD90245/2023-2024:Providing and fixing mechanical flow meter size 200 mm
Appendix F -Electrical sub station at raw water pump house with 100*2hp pumpset and 100 hp stand by pump and other components
OD172951/2022-2023:Supply and Laying of 11kV, 3C x 185 sq.mm XLPE power cable in duct / trench etc. as complying to specifications and standards
OD172952/2022-2023:Supply and Fixing of end terminations for 11kV, 3C x 150 sq.mm. XLPE cables including heat shrinkable type end-sealing kit of approved make and quality with all required accessories, etc. as required and complying to specifications and standards- Indoor
OD172953/2022-2023:Supply and Fixing of end terminations for 11kV, 3C x 150 sq.mm. XLPE cables including heat shrinkable type end-sealing kit of approved make and quality with all required accessories, etc. as required and complying to specifications and standards- Outdoor
OD172954/2022-2023:Supply Installation, testing and commissioning of unitised substation with HT metering equipments, CTs, PT of class 0.2S, TOD meter class0.2S and with 500KVA, 11KV/433V, 3-phase, 50Hz, Cast resin dry type indoor Transformer with all standard accessories linked with a 12kV Load break SFU with HRC fuse shunt trip, remote tripping mechanism, seal off bushings etc. including all control wiring, testing of relays/CTs etc. installation shall be done asper standards and as per CEA regulations applicable.
OD172955/2022-2023:Supply, Design, Fabrication, Erection, Testing and Commissioning of following cubicle type, fully compartmentalised LT switchboards dust tight and vermin proof, fabricated out of 14/16 SWG CRCA sheet, chemically treated and powder coatd with 2 coats approved shade. The Panel boards shall have an IP rating of IP 54. The switchboards should have a set of suitably rated TPN Aluminium busbars with the specified current and fault level, insulated with heat shrinkable, color coded PVC sleeves and supported using DMC/SMC pillar or Finger type busbar supports.The design shall be as per the standards of the State Electrical Inspectorate. All indication lamps should be LED type, all MCCBs shall be with rotary operating handle.
OD172956/2022-2023:SSB - 1 -Supply, Design, Fabrication, Erection, Testing and Commissioning of following cubicle type, fully compartmentalised LT switchboards dust tight and vermin proof, fabricated out of 14/16 SWG CRCA sheet, chemically treated and powder coatd with 2 coats approved shade. The Panel boards shall have an IP rating of IP 54. The switchboards should have a set of suitably rated TPN Aluminium busbars with the specified current and fault level, insulated with heat shrinkable, color coded PVC sleeves and supported using DMC/SMC pillar or Finger type busbar supports.The design shall be as per the standards of the State Electrical Inspectorate. All indication lamps should be LED type, all MCCBs shall be with rotary operating handle.Fabricated out of 14 SWG CRCA sheet.<br>Top/bottom cable entry for incoming and outgoing feeders. 1)Busbar of electrolytic Al. 1250A - 1set <br>2) Incomer:- Draout type mechanically operated 1000A 50kA 4P ACB with 3 OC, SC 1 no. <br>3) Meters and Indications: <br>VAF +PF meter with CTs and mcb/fuse protection - 1 set <br>Red, Yellow and Blue LED Indication lamps 1 Set.<br>4) Outgoings: <br>a) 400A, 50kA TPN MCCB MCCB Setting 320-400- 2No.<br>b) 250A, 36kA TPN MCCB MCCB Setting 125-160- 4No. c) 100A, 25kA TPN MCCB Setting 80-100 - 3No.
OD172957/2022-2023:SSB - 2 -Supply, Design, Fabrication, Erection, Testing and Commissioning of following cubicle type, fully compartmentalised LT switchboards dust tight and vermin proof, fabricated out of 14/16 SWG CRCA sheet, chemically treated and powder coatd with 2 coats approved shade. The Panel boards shall have an IP rating of IP 54. The switchboards should have a set of suitably rated TPN Aluminium busbars with the specified current and fault level, insulated with heat shrinkable, color coded PVC sleeves and supported using DMC/SMC pillar or Finger type busbar supports.The design shall be as per the standards of the State Electrical Inspectorate. All indication lamps should be LED type, all MCCBs shall be with rotary operating handle.Fabricated out of 14 SWG CRCA sheet.<br>Top/bottom cable entry for incoming and outgoing feeders. 1)Busbar of electrolytic Al. 250A - 1set <br>2) Incomer:- 250A TPN Isolator - 1 no. <br>3) Meters and Indications: <br>VAF +PF meter with CTs and mcb/fuse protection - 1 set <br>Red, Yellow and Blue LED Indication lamps 1 Set.<br>4) Outgoings: <br>a) 100A, 25kA TPN MCCB Setting 63-80A- 6No.<br>b) 100A, 25kA TPN MCCB Setting 50-63- 1No. c) 100A, 25kA TPN MCCB Setting 25-32- 4No.
OD172958/2022-2023:DISTRIBUTION BOARDS - Supply installation testing and comissioning 10-32A TP MCB Isolators of reputed make with suitable enclosure installed within 3mtre as local isolstion for equipments (1HP,to 5HP motors)
OD172959/2022-2023:DISTRIBUTION BOARDS - Supply installation testing and comissioning locable on/off push button of reputed make for emergency trip of USS
OD172960/2022-2023:DISTRIBUTION BOARDS - Supply installation testing and comissioning 125A TP Isolators of reputed make with suitable enclosure installed within 3mtre as local isolstion for equipments (30HP, 20HP motors)
OD172961/2022-2023:MV CABLE SUPPLY & LAYING - Supply and Laying reputed make 3.5x 400 sqmm 1.1kV grade armoured aluminum conductor XLPE cable as per standards (USS to MSB, MSB to SSB1,
OD172962/2022-2023:Supply and Laying reputed make 3.5x 240 sqmm 1.1kV grade armoured aluminum conductor XLPE cable as per standards (USS to MSB 4runs
OD172963/2022-2023:MV CABLE SUPPLY & LAYING - Supply and Laying reputed make 3.5x185 sqmm 1kV grade armoured aluminum conductor XLPE cable as per standards (SSB 1 to 180Hp Motors 1&2 and APFC
OD172964/2022-2023:MV CABLE SUPPLY & LAYING - Supply and Laying reputed make 3.5x 35 sqmm 1.1kV grade armoured aluminum conductor XLPE cable as per standards SSB 1 to VDB L1,SSB2 to switchboard (existing ) ,SSb 2VDB P1,P2 and L2
OD172965/2022-2023:MV CABLE SUPPLY & LAYING - Supply and Laying reputed make 3x 16 sqmm 1kV grade armoured aluminum conductor XLPE cable as per standards(SSB2 to backwash 20Hp Motor )
OD172966/2022-2023:MV CABLE SUPPLY & LAYING - Supply and Laying reputed make 4x 10 sqmm 1.1kV grade armoured aluminum conductor XLPE cable as per standards (VDBs to LDBs)
OD172967/2022-2023:End Termination - Supply and providing of end termination for 3.5x 400 sqmm 1.1kV grade armoured aluminum conductor XLPE cable as per standards
OD172968/2022-2023:End Termination - Supply and providing of end termination for 3.5x240 sqmm 1.1kV grade armoured aluminum conductor XLPE cable as per standards
OD172969/2022-2023:End Termination - Supply and providing of end termination for 3.5x 185 sqmm 1.1kV grade armoured aluminum conductor XLPE cable as per standards
OD172970/2022-2023:End Termination - Supply and Laying reputed make 3.5x 95 sqmm 1.1kV grade armoured aluminum conductor XLPE cable as per standards
OD172971/2022-2023:End Termination - Supply and providing of end termination for 3.5x35 sqmm 1.1kV grade armoured aluminum conductor XLPE cable as per standards
OD172972/2022-2023:End Termination - Supply and providing of end termination for 3x 16 sqmm 1kV grade armoured aluminum conductor XLPE cable as per standards
OD172973/2022-2023:End Termination - Supply and providing of end termination for 3x 10 sqmm 1.1kV grade armoured aluminum conductor XLPE cable as per standards
OD172974/2022-2023:End Termination - Supply and providing of end termination for 4x 6 sqmm 1.1kV grade armoured aluminum conductor XLPE cable as per standards
OD172975/2022-2023:End Termination - Supply and providing of end termination for 4x 4 sqmm 1.1kV grade armoured aluminum conductor XLPE cable as per standards
OD172976/2022-2023:End Termination - Supply and providing of end termination for 2x 2.5 sqmm 1.1kV grade armoured copper conductor XLPE cable as per standards
OD172977/2022-2023:EARTHING -Supplyand providing of standard plate earthing using 1200x1200x12mm CI plate electrode with all other earthing materials and watering and inspection chamber etc as per standards of BS 3048 and CEA regulations.
OD172978/2022-2023:EARTHING - supply and laying 50 x6mm hot dip GI strip for earthing the system
OD172979/2022-2023:EARTHING - supply and laying 25x6mm GI hot dip strips for Panel earthing
OD172980/2022-2023:Supply and fitting gland earthing clips 25x3 CU
OD172981/2022-2023:EARTHING - supply and laying of SWG no.6 copper wire for DG set and equipment earthing
OD172982/2022-2023:EARTHING - supply and laying of SWG no.10 copper wire for equipment earthing
OD172983/2022-2023:Fabricating supplying and erecting cable tray by using suitable size angle iron, flats, squares etc as required
OD172984/2022-2023:SAFETY EQUIPMENTS - Supply and fixing 6kg DCP fire extinguisher
OD172985/2022-2023:SAFETY EQUIPMENTS - Supply and fixing fire bucket with stand
OD172986/2022-2023:SAFETY EQUIPMENTS - Supply and fixing Electrical grade 11KV synthetic mat
OD172987/2022-2023:SAFETY EQUIPMENTS - Supply and fixing Electrical grade 1KV synthetic mat
OD172988/2022-2023:SAFETY EQUIPMENTS - Supply and fixing first aid chart
Appendix B - Supply ,Installation and commissioning of Pump sets for KADAPLAMATTOM AND MARANGATTUPALLY PANCHAYATHs
OD90246/2023-2024:Providing and fixing electromagnetic flow meter size 300 mm
OD90247/2023-2024:Providing and fixing mechanical flow meter size 200 mm
Appendix C - Supply ,Installation and commissioning of Pump sets for KIDANGOOR,KADAPLAMATTOM AND MARANGATTUPALLY PANCHAYATHs - AT RAW water PUMP house Kavalipuzha
OD90249/2023-2024:Providing and fixing electromagnetic flow meter size 450 mm
Appendix H -Construction of Building for Indoor type Transformer at TP
2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.2.2:Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
4.3.1:Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns
6.3.1:Brick work with common burnt clay machine moulded perforated bricks of classdesignation 12.5 conforming to IS: 2222 in superstructure above plinth level up tofloor five level in cement mortar 1:6 (1 cement : 6 coarse sand):With F.P.S. ( non modular ) bricks
4.3.3:Centering and shuttering including strutting, propping etc. and removal of form work for:Columns, piers, abutments, pillars, posts and struts
13.7.2:12 mm cement plaster finished with a floating coat of neat cement of mix:1:4 ( 1 cement : 4 fine sand)
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.48.1:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm
11.3.1:Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate)finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate
9.1.3:Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Kiln seasoned and chemically treated Hollock wood
9.7.3.1:Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick: Ply wood 5 ply, 9 mm thickDecorative plywood both side decorative veneer (Type - I) conforming to IS 1328 BWR type.
10.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover
13.48.3:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
13.50.1:Applying priming coat:With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
Appendix I -Construction of Ramp, Indoor Transformer Building and Plat form for Existing Transformer at Kavalippuzha pump house
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
4.1.6:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
5.37.2:Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in -charge. Note:- Cement content considered in this item is @330 kg/cum. Excess /less cement used as per design mix is payable/recoverable separately.All work above plinth level upto floor V level
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.7:Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
50.6.1.5:Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.83.2:Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats
21.10:Providing and fixing double glazed hermetically sealed glazing in aluminium window, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant ) etc. as per specifications, drawings and direction of Engineer-in-Charge complete.
10.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover
10.7:Providing and fixing ball bearing for rolling shutters.
9.48.2:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc
Appendix J - Construction of 4.00 LL Capacity OHSR AT WTP Kidangoor
2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2.9.1:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock
100.2.2:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10m2 on plan), including dressing of sides and ramming of bottoms, lift up to 1.5m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50m, in Medium Rock where Blasting is Prohibited.
2.9.3:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Hard rock (blasting prohibited)
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
4.1.6:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.33.1:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level
5.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
5.34.1:Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).
5.35:Add for using extra cement in the items of design mix over and above the specified cement content therein
22.4.1:Providing and Placing in position suitable PVC water stops conforming to IS : 12200 for construction / expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete:Serrated with central bulb ( 225 mm wide, 8-11 mm thick)
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
50.6.1.6:Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level thickness 20cm and above in : CM 1:6 ( 1 cement : 6 coarse sand sand) etc complete
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.9.1:Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster
50.13.1:9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
13.71:Lettering with black Japan pint of approved brand and manufacture
10.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover
10.7:Providing and fixing ball bearing for rolling shutters.
10.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes
50.9.1.1:Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood
50.9.5.1:Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked M.S pressed butt hinges bright finished of required size with necessary screws. Using Anjili wood/ jack wood 35 mm thick shutters.
50.9.15.5:Providing and fixing iron hooks and eyes: 100 mm
14.29:Providing and fixing M.S. round or squre bars with M.S. flats at required spacing in wooden frames of windows and clerestory windows.
18.26.1:Providing and laying flanged C.I. Standard specials such as tees, bends, collars, tapers, caps etc., suitable for flanged jointing as per IS : 1538 :Upto 300 mm dia
18.30.4:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:150 mm diameter pipe
18.30.7:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:300 mm diameter pipe
18.30.5:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:200 mm diameter pipe
18.30.6:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:250 mm diameter pipe
18.31.3.2:Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertion etc. (the tail pieces if required will be paid separately): 150 mm diameterClass II
18.31.4.2:Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertion etc. (the tail pieces if required will be paid separately): 200 mm diameterClass II
18.31.5.2:Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertion etc. (the tail pieces if required will be paid separately): 250 mm diameterClass II
18.31.6.2:Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertion etc. (the tail pieces if required will be paid separately): 300 mm diameterClass II
18.69.1:Providing and laying D.I Specials of Class K - 12 suitable for mechanical jointing as per IS : 9523 :Upto 600 mm dia
18.73.2:Providing and laying Double Flanged ( Screwed / Welded ) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS: 8329 :150 mm dia Ductile Iron Double Flanged
18.73.3:Providing and laying Double Flanged ( Screwed / Welded ) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS: 8329 :200 mm dia Ductile Iron Double Flanged
18.73.4:Providing and laying Double Flanged ( Screwed / Welded ) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS: 8329 :250 mm dia Ductile Iron Double Flanged
18.73.5:Providing and laying Double Flanged ( Screwed / Welded ) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS: 8329 :300 mm dia Ductile Iron Double Flanged
19.18.3:Supplying and fixing C.I with out frame for manholes:560 mm diameter ( heavy duty) the weight of the cover to be not less than 108 kg
OD189059/2022-2023:supplying an electro -magnetic flow meter conforming to protection level of IP 68 for flow sensor and IP - <br>67 for transmitter and having an accuracy level of 0.5% with LED/LCD display unit .The flow meter should<br>have the housing( flow sensor ) to be made of SS 304/carbon steel with anti corrosive protection and<br>inside liner to be made of Hard rubber /ne0 prone all conforming to drinking water standards .The flow<br>meter should be coupled with HART for data acquisition and transfer trough GSM. The manufacturers<br>should have the calibration standards as per ISO 17025 and the product shall have sufficient warranty<br>provisions- For 250mm dia pipe
OD189060/2022-2023:Supplying and fitting CI Vent cow with providing moisture proof arrangements
OD189061/2022-2023:Supplying and fixing water level indicator with all accessories including cost,conveyance and labour charges.
OD189062/2022-2023:Supplying and providing lightening conductor to the tank of appropriate places and providing suitable earthing as per IS code
OD189063/2022-2023:Providing solar panel with storage battery to light two members to watt CFL lamp,including cost of shade<br>fabricated stand post etc.
100.36.1:Filling water with 5000 litre tankers fited in lorry and conveying water from a distance of 5 km (average) to the reservoir site and pumping the water into the reservoir of height not less than 3 m using 5 HP diesel engine pump set , hire for tanker lorry, tools and other appliences and cost of water etc. complete.
Appendix L : Supply & Laying 200 mm DI pumping line From WTP to Kadaplamattom
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.1.5:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50 m, in Ordinary Rock.
100.2.2:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10m2 on plan), including dressing of sides and ramming of bottoms, lift up to 1.5m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50m, in Medium Rock where Blasting is Prohibited.
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.
100.14.3:Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials: 200mm diameter Ductile Iron Class K-9 Pipes.
100.35.3:Testing 200mm DI/CI pipeline with potable water to the required test pressure 200 mm dia Observed Data derived from item no.1020 of PHED DATA
100.98.117:Supply of DI K9 Pipe Conforming to IS 8329/2000, 200mm Dia.
18.30.5:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:200 mm diameter pipe
18.68.1:Providing and laying D.I specials of class K - 12 suitable for push - on jointing as per IS : 9523 :Upt 600 mm dia
18.69.1:Providing and laying D.I Specials of Class K - 12 suitable for mechanical jointing as per IS : 9523 :Upto 600 mm dia
18.70.3:Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:200 mm dia pipes
18.83.5:Labour for cutting C.I. pipe with steel saw.200 mm diameter C.I. pipe
Appendix M : Road restoration work For Pipe laying
3.6:Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000m
4.1.A.3:Granular Sub-Base with Close Graded Material (Table:- 400-1) :- Plant Mix Method - Grading - III Material Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401
4.12:Providing, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.
5.1.a:Providing and applying primer coat with bitumen emulsion ( SS) on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 - 1.0 kg/sqm using mechanical means.
5.2.a:Providing and applying tack coat with bitumen emulsion( RS) using emulsion pressure distributor at the rate of 0.20 - 0.30 kg per sqm on the prepared bituminous surface cleaned with mechanical broom.
5.3.2.a:Providing and laying bituminous macadam with 80-100 TPH hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading premixed with a bituminous binder (VG 30), transported to the site, laid over a previously prepared surface with paver finisher to the required grade, level, and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction For Grading II - (19 mm nominal size)
55.24:Providing and laying bituminous concrete with 80-100 TPH hot mix plant producing an average out put of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder (NRMB) @ 5.4 percent of mix and filler, transporting the hotmix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause NO. 507 complete in all respects (using 7% shredded plastic) Grading - II (13.2 mm nominal size)
Appendix N: Retaining wall & Compound wall work
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
2.7.1:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock
4.1.6:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
5.2.2:Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
50.2.25.1:Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge
50.6.1.5:Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
10.1:Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
10.16.1:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.50.4:Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat)
13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
13.65.1:Painting with black anti- corrosive bitumastic paint of approved brand and manufacture to give an even shade:Two or more coats on new work
13.71:Lettering with black Japan pint of approved brand and manufacture
16.78.1:Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With Material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30
16.79:Providing , laying spreading and compacting graded stone aggregate ( size range 53 mm to 0.075 mm) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub - base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer - in- Charge.
16.33.3:2.5 cm premix carpet surfacing with 2.25 cum and 1.12 cum of stone chippings of 13.2 mm and 11.2 mm size respectively per 100 sqm and 52 kg and 56 kg of hot bitumen per cum of stone chippings of 13.2 mm and 11.2 mm size respectively, including a tack coat with hot straight run bitumen, including consolidation with road roller of 6 to 9 tonne capacity etc. complete ( tack coat to be paid for separately):With Refinery Modified Bitumen CRMB 55 conforming to IRC:SP:53 - 1999
16.91.2:Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.
NAVIN CONSTRUCTION CORPORATION
Bidder Name
NAVIN CONSTRUCTION CORPORATION
N.T.KURIAKOSE
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid