Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC JAIN SADAN MAHAL ROAD SHIVPURI DISTT SHIVPURI MP | SHIVPURI | SHIVPURI | MADHYA PRADESH | ₹1.1 Cr Quoted ₹1.2 Cr | L1 | Accepted-AOC Being lowest and reasonable |
| 2 | L2₹1.3 Cr+₹9.8 L (8.51%)Rejected-Finance | ₹1.3 Cr+₹9.8 L (8.51%) | L2 | Rejected-Finance Being L2 |
| 3 | L3₹1.5 Cr+₹31.7 L (27.4%)Rejected-Finance 6313 14 PUNJABI MOHALLA AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | ₹1.5 Cr+₹31.7 L (27.4%) | L3 | Rejected-Finance Being L3 |
| 4 | L4₹1.5 Cr+₹34.7 L (30.1%)Rejected-Finance | ₹1.5 Cr+₹34.7 L (30.1%) | L4 | Rejected-Finance Being L4 |
| 5 | L5₹1.5 Cr+₹34.8 L (30.1%)Rejected-Finance B 3 3 DHANALAXMI PARK OPP PMT BUS DEPOT BHUSARI COLONY PAUD ROAD KOTHRUD PUNE 411 038 | PUNE | PUNE | MAHARASHTRA | 411038 | ₹1.5 Cr+₹34.8 L (30.1%) | L5 | Rejected-Finance Being L5 |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
3 Mar 2020, 6:00 pmClosed
CWE AF AMBALA
CWE AF AMBALA
CA NO CWE/AF AMB/AMB-42/2019-20 IMPROVEMENT TO BUILDINGS AT WSA-III AT AF STATION AMBALA UNDER GE AF AMBALA
2019_MES_301952_1
CA NO CWE/AF AMB/AMB-42/2019-20
Open Tender
Civil Works
Item Rate
183 days
GE AF AMBALA
All contractors enlisted with MES in Class B and above and Category ai and for unenlisted refer tender documents
8 documents required · 8 mandatory
₹1,000
Yes
GE AF AMBALA
₹2.2 L
Yes
18 May 2020
28 Nov 2019
5 Mar 2020
28 Nov 2019
3 Mar 2020
13 Feb 2020
28 Nov 2019 - 13 Dec 2019
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises to a distance not exceeding 500 mtr complete all as specified and directed.
Dismantling Asbestos cement plain or corrugated steel sheeting incl ridges any gauge/thickness nainital or similar pattern as in roof covering complete all as specified and as directed
Demolition of plain cement concrete,un-reinforced, in ground floor and paving not exceeding 15 cm thick below or above ground floor including rubbish off the premises to a distance not exceeding 500 mtr complete all as specified and directed.
Demolition of RCC, of any description and in any position inluding cutting of reinforcement to facilitate demolition and rubbish off the premises to a distance not exceeding 500 mtr complete all as specified and as directed.
Dismantling of RCC/PVC water tanks of any description exc 250 ltrs and not exceeding 500 ltrs and removing from site including rubbish off the premises to a distance not exceeding 500 mtr complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for and rubbish off the premises to a distance not exceeding 500 mtr complete all as specified and as directed.
Dismantling of brick work built in cement mortar including all quoins, pillars etc but excluding ashlar facings, dressed stone work and precast articles and rubbish off the premises to a distance not exceeding 500 mtr complete all as specified and as directed.
Dismantling of brick tiles or concrete tiles single layers on roof and rubbish off the premises to a distance not exceeding 500 mtr complete all as specified and as directed.
Demolition of mud phuska on roofs, any thickness including mud plastering,whether full thickness removed or only a part thereof and rubbish off the premises to a distance not exceeding 500 mtr complete all as specified and as directed.
Dismantling of wrought iron or mild steel work of any description not otherwise specifically provided for complete all as specified and as directed
Dismantling of mild steel work of any description not otherwise provide for wind ties, purling, rafter etc complete all as specified and as directed
Taking down/out existing unserviceable LT cable ,of any size & type, from any position such as from duct,wall,floor,pole including removal of cable joints,pipes,clamps,cable cover etc complete all as specified and as directed.
Taking down cement plaster on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water including removal of debries to distance n.exc 500 mtr complete all as specified and directed.
Taking down cement plaster from soffits of slab/chajjas/sunshades etc including racking out joints, hacking for key, scrubbing down with water including removal of debries to distance n.exc 500 mtr complete all as specified and directed.
Taking down chowkhats or frames exc 1.5 but n.exc 4 sqm each with shutters without taking off shutters from the frame and removing from site, including cutting holes for taking out hold fasts and making good disturbed portion in cement mortar 1:3, complete all as specified and as directed
Cutting holes brick walls built in cement mortar exceeding half brick thick wall but not exceeding one brick thick wall built in cement mortar for inserting hold fasts etc and making good the dismantled portion in plain cement concrete 1:2:4 type B1 & finished to match as per the existing finish complete all as specified and as directed.
Surface dressing n.exc. 15 centimetre deep and getting out in soft/ loose soil complete all as specified and directed.
Material and labour for Hard core of broken stone or boulders of gauge n.exc 63 mm deposited spread and leveled in layers n.exc 15 cm thick watered and rammed to a true surface complete all as specified and as directed.
Roughening surface of old concrete floor by picking sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry @ 3.0 Kg per Sqm complete all as specified and as directed
Material and labour for PCC 1:4:8, type D-2 using 40mm graded mechanically crushed stone aggregates as in foundation filling and mass concrete of floors complete all as specified and directed.
Material and labour for 75mm thick PCC 1:4:8, type D-2 using 40mm graded mechanically crushed stone aggregates as in sub base of floors complete all as specified and directed.
Material and labour for 25mm thick PCC 1:2:4 type B0 using 12.5 mm graded mechanically crushed stone aggregates as in floor finished even and smooth without using extra cement complete all as specified and directed.
Material and labour for 150mm thick PCC 1:2:4 type B1 using 20 mm graded mechanically crushed stone aggregates as in floor finished even and smooth without using extra cement complete all as specified and directed.
Material and labour for PCC 1:2:4 type B-0 using 12.5mm graded mechanically crushed stone aggregates as in padding on roof to maintain the required slope & finished the surfaces even and smooth without using extra cement complete all as specified and as directed.
Material and labour for PCC 1:2:4 type B-0 using 12.5 mm graded mechanically crushed stone aggregates as in roof kerbs ,benching etc rounded or moulded etc including weathering slightly rounded or chamfered angles of throating including necessary form work complete all as specified and as directed.
Material and labour for PCC 1:3:6, type C-1 using 20mm graded mechanically crushed stone aggregates as in hold fast including necessary form work complete all as specified and as directed.
Material and labour PCC 1:2:4 type B-1 using 20mm graded mechanically crushed stone aggregate as in blocks for embedding GI pipe including necessary form work complete all as specified and directed.
Material and labour PCC 1:2:4 type B-1 using 20mm graded mechanically crushed stone aggregate as in copings,channels,drain, bed blocks etc including necessary form work complete all as specified and directed.
Material and labour for RCC 1:2:4 type B-1,nominal mix using 20 mm graded mechanically crushed stone aggregates as in chajjas,fins, fascia louvers, parapet and railing complete all as specified and as directed.
Material and labour for forming 12mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade `B' including necessary form work complete all as specified and directed.
Material and labour for forming contraction (Dummy) joints 65 mm deep x 10mm wide, filled with sealing compound Grade ' B' including necessary form work complete all as specified and directed.
Material and labour for forming construction joint 30mm deep x 10mm wide filled with sealing compound Grade' B' including necessary form work complete all as specified and directed.
Material & Labour for repair to chajjas/ roof projection with plain cement concrete 1:2:4 type B-0 using 12.5 mm graded mechanically crushed stone aggregates and dubbing out with 20 mm avereage thickness including necessary form work after taking down/ demolition of loose portion/ part/ particles & rendering with 5 mm thick in cement mortar 1:3 and finishing the exposed surfaces even & smooth using extra cement complete all as specified and as directed.
Use and waste of form work to chajjas including edges, fins, facia and similar works for rough finished surfaces of concrete complete all as specified.
Material and labour for Brick work with sub class B bricks of old size, straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6 complete all as specified and as directed.
Material and labour for Brick work straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6 using old bricks retrieved from srl No 07 here-in-before after cleaning and washing complete all as specified and as directed.
Material and labour for Brick work with sub class B bricks of old size, straight or curved on plan to any radius in half brick thick wall, built in cement mortar 1:4 complete all as specified and as directed.
Material and labour for 40 mm thick brick tiles laid on roofs, jointed and grouted flush in CM 1:3 mixed with and including linseed/crude oil @ 5% by weight of cement over and included 15 mm thick screed bedding in cement mortar 1:6 complete all as specified and as directed.
Material and labour for Brick tiles laid on roofs using old tiles retrieved from srl No 08 here-in-before after cleaning and washing , jointed and grouted flush in CM 1:3 mixed with and including linseed/crude oil @ 5% by weight of cement over and included 15 mm thick screed bedding in cement mortar 1:6 complete all as specified and as directed.
Material and labour for jointfree coloured, non- skid jointfree,edgecut, ceramic tiles,1st quality premium, 7 to 8 mm thick ,square/ rectangular, area of each tile exceeding 0.06 but not exceeding 0.11 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over and including 15mm thick screed bed or bedding layers in Cement Mortar 1:4, complete all as specified and directed.
Material and labour for jointfree glazed designer ceramic coloured tiles of size 300x450x7-8 mm thick 1st quality on vertical surface as in skirting/dado, set and jointed in neat cement slurry & pointed in white or coloured cement to match over and including 10mm thick rendering in cement mortar 1:4 on brick / concrete walls complete all as specified and as directed. Notes for item No 40 & 41 :- (i) The rates includes for all straight cutting and waste including raking or circular cutting complete. (ii) All corners in wall tiling should be properly metred jointed to give monolithic uniform apprearance. (iii) The rates for tiling includes for laying to any pattern with one or more colour as directed. (iv) If tiles of different sizes are used then no price adusjtment shall be made.
Material and labour for extra over rendering or plastering for work in isolated widths or in widths not forming part of general plastering such as in bands, sunk panels,cornices, skirtings, drip moulds and similar work exc n exc 15 cm in width or girth; including cutting to edges, all mitres and stopped ends, complete all as specified and directed.
Material and labour for rendering 15 mm thick in CM 1:6 finished even and smooth without using extra cement on fair faces brick or concrete surfaces complete all as specified and directed.
Material and labour for rendering 15 mm thick in CM 1:4 mixed with WPC @ 2 % by weight of cement finished even and smooth without using extra cement on fair faces brick or concrete surfaces complete all as specified and directed. Note : WPC shall be measured and paid separately as supply only.
Material and labour for rendering 15 mm thick in CM 1:4 on brick or concrete surfaces of any description mixed with and including Dr Fixit URP (SBR latex) added at the rate of 7 kg per bag of cement finished even and smooth without using extra cement complete all as specified and directed.
Material and labour for applying three coats of heavy duty elastomeric waterproof wall coating of DR FIXIT RAINCOAT over & including 1 coat of Dr FIXIT PRIMSEAL to achieve total 110 microns DFT thickness of the desired shade complete all as specified and directed.
Material and labour for rendering 5 mm thick in CM 1:3 on the soffits of slab/chajjas/sunshade etc finished even and smooth without using extra cement complete all as specified and directed.
Supply only integral water proofing compound complete all as specified and as directed.
Supplying and fixing pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour as directed having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Supplying and fixing pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour as directed having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
BLANK
BLANK
Material and labour for Mild steel TMT bars ,Fe 500 D, 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Material and labour for Mild steel TMT bars ,Fe 500 D, 8mm dia and over as in stirrups, spacers and binders complete all as specified and directed, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Supply and fixing mild steel framed work as in door or gate of angle or other sections with gusset plates, rails, braces etc, using ornamental design as approved complete drilled for fixing of steel sheeting or other covering, doors etc to be prepared for hanging or sliding with and including either hooks and purpose made hinges or steel hanging door fittings exclusive of steel sheeting or other covering, running rails and guides, and hanging, fastening and fixing complete conforming to Fe-290 Gde E-165 ,machine butt hinges and flat iron hold fasts to be measured separately, complete all as specified and as directed.
Supply and fixing Mild steel 1.25 mm thick plain black sheet, but in hearths; covering to door shutters; covering to door chowkats (frames); chullah hoods cut to size, edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members,with plain 40mm lap joints or welded/riveted seams including bending, turning up, mitred angles, stopped ends, outlets,etc. as required complete all as specified & as directed.
Supply and fixing mild steel work as in hold fast, handrails, balastters, nosing to steps including embedding in concrete, wind tie for roof, post shape incl all necessary drilling, bolting & rivetting etc & similar work conforming to fe-290 Gde E-165 complete all as specified and as directed.
Supply and fixing mild steel section such as in roof truss, rails, purlin as in framed work for roof covering including all flange, cutting, welding, drilling holes for screws including distance pieces and cleats etc complete all as specified and conforming to Fe 410-0 W (Gde-E-250) quality-A complete all as specified.
Supply and fixing galvanised mild steel water tubes 15 mm bore, medium grade, galvanised with all fittings and fixed complete to wall and ceiling or laid in floor after taking down/out tubes as existing at site complete all as specified and as directed.
Supply and fixing galvanised mild steel water tubes 20 mm bore, medium grade, galvanised with all fittings and fixed complete to wall and ceiling or laid in floor after taking down/out tubes as existing at site complete all as specified and as directed.
Supply and fixing in repair vitreous china squatting pan (Orissa pattern) 580mmx440mm, white, with PVC ‘P’ or ‘S’ trap front or back inlet with integral foot rests excluding flushing cistern and flush pipe including providing lime concrete bedding complete all as specified and directed
Supply and fixing in repair PVC low level flushing cistern, white, valveless syphonic action type 10 lts capacity with inlet, ball valve, float and handle including PVC flush pipe 32 mm dia with bend and a pair of mild steel angle iron/PVC brackets of suitable size including making necessary connections to water supply pipe line and WC, complete all as specified and as directed.
Supply and fixing rotational moulded polythene (PVC) water storage tank,HDPE, of white colour, triple layered ,cylinderical type fixed and hoisted in position on roof, at any height, of capacity 500 ltrs and making connections with 20 mm GI pipe inlets & outlets complete including locking arrangements and 20 mm bore ball brass valve high pressure with polyethylene float complete all as specified and directed.
Supply and fixing in repair vitreous china wash hand basin ,oval type, white, of size 550X490mm including 32mm bore PVC waste pipe and CP waste fitting and a pair of mild steel angle iron brackets of suitable size fixed in counter slab complete all as specified and as directed.
Supply and fixing in repair 15 mm dia pillar tap , fancy type, brass chromium plated with capstan head chromium plated screwed down high pressure with or without lettered “hot' or 'cold” with long screwed shank and flynut screwed complete all as specified.
Supply and fixing in repair stop valve 15mm bore, fancy type brass chromium plated , screwed down high pressure with crutch or butterfly handle screwed both ends complete all as specified and as directed.
Supply and fixing in repair angle valve 15mm bore, fancy type brass chromium plated screwed down high pressure with crutch or butterfly handle screwed both ends complete all as specified and as directed.
Supply and fixing in repair bib taps 15 mm bore, brass, chromium plated, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed.
Supply and fixing in repair brass Chromium plated shower rose, fancy type,suitable for 15 mm boe pipe with or without swivel joints any size including fixed to steel pipe or union complete all as specified and as directed.
Supply and fixing brass chromium plated towel rail 20mm dia ,fancy type, 60cm long,superior quality , between flanges fixed to wall with brass CP screws after taking down/out as existing at site complete as specified and directed.
Supply and fixing soap dish ,brass, chromium plated,size 160 x 160 x90 mm fixed with and including plugs with brass CP screws after taking down/out as existing at site complete all as specified and as directed.
Supply and fixing stainless steel grating 150mmX150mm size square fixed complete all as specified.
Supply and fixing in repairs PVC connection 450mm long with 2 nos PTMT check nuts, suitable for 15mm bore complete all as specified and directed
Supply and fixing in repairs PVC connection 600mm long with 2 nos PTMT check nuts, suitable for 15mm bore complete all as specified and directed
Supply and fixing PVC (SWR) pipe 110mm bore single socketed in any length with rubber ring joints, laid in trenches or in floors, fixed to wall with suitable size FI clamps of size 25mmx3mm,after taking down/out pipe as existing at site complete all as specified and as directed.
Supply and fixing PVC (SWR) pipe 75mm bore single socketed in any length with rubber ring joints, laid in trenches or in floors, fixed to wall with suitable size FI clamps of size 25mmx3mm,after taking down/out pipe as existing at site complete all as specified and as directed.
Supply and fixing PVC (SWR) bends any radius, for 110mm bore of pipe complete all as specified and as directed.
Supply and fixing PVC (SWR) bends any radius, for 75mm bore of pipe complete all as specified and as directed.
Supply and fixing PVC (SWR) gully trap 125x110 mm ,made of type-B pipes ,setting and jointing with solvent cement complete all as specified and as directed.
Supply and fixing PVC (SWR) floor trap plain with grating including jointing with solvent cement, 75mm dia outlet including setting and jointing to waste pipe, fixed in PCC 1:2:4 type B0, complete all as specified and as directed.
Supply and fixing suspended ceiling lay- in perforated with fleece tegular edge global ,white tiles of size 595 x 595 mm, 0.5 mm thick with 8 mm drop and 10mm flange, made of GI sheet having glavanising of 100 gm per sqm both side inclusive electro statically polyster power coated of thickness 60 micron (minimum ) with and including factory painted after bending the tile having humidity resistance (RH) of 100 % with light reflection of 62% on interlocking metal grid of hot dipped galvanised steel section (Galvanised @ 120 gms per sqm) both side inclusive consisting of main "T" runners with suitably space joints to get required length of size 24x 34 x38 mm made from 0.30 mm thick (minimum) sheet , spaced at 1200 mm center to center,cross 'T' of size 24x 25 mm made of 0.30 mm thick (minimum) sheet 1200 mm long spaced between main 'T' at 600 mm center to center to form a grid of 1200 x 600 mm, secondary cross 'T' of length 600 mm with size 24x 25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200 x 600 mm panel to form grid of 600x 600 mm and wall angle of size 24 x 24 x 0.30 mm including laying of false ceiling tiles of approved structure in the grid including required cutting/ making, opening for services like diffusers , grills , light fitting, fixtures, smoke deductors etc main 'T' runner to be suspended from ceiling using GI slotted clearts of size 27x 37x 25x 1.6 mm fixed to ceilings with 12.5 mm dia and 50 mm long dash fastners, 4 mm GI adjustable rod with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm centre to centre along main 'T' , bottom exposed width of 24 mm of all 'T' sections shall be pre-painted with polyster paint including testing all as per manufacturer's instructions including taking down of false ceiling as exists at site complete all as specified and as directed.
Material and labour for APP polymeric water proofing treatement to roof, at any height, using membrane minimum 3 mm thick and weighting not less than 3.6 kg/sqm , black finish reinforced with non-woven polyster matt (Weight not less than 150 gms/Sqm) with thermo fusible finish laid by force application after applying compatible bitumen primer at the rate of 0.40 Ltr per Sqm, torching over laps with a propane or butane gas torch with a over lap of 100 mm at the side on transverse direction and 150 mm at the ends on longitudinal direction and sealing including a tack coat of hot blown bitumen 85/25 @ 1.2 Kg/Sqm below APP complete all as specified and as directed . Note:- (i) The water proofing treatment shall be got carried out by the manufacturer or their authorised applicators duly approved by GE in writing. (ii) 5% amount of the total amount of water proofing treatment shall be retained as a guarantee and shall be released after 10 years. However contractor may deposit the FDR of same amount in favour of GE. If contractor fail to rectify the defect pointed out during this period in writing, the defect shall be got rectified at contractor' risk and cost and the payment shall be made from the amount kept reserved or by encashing the FDR deposited by the contractor as guarantee. The contractor's quoted rates for this item shall deemed to be inclusive of this aspect.
Material and labour for one coat of cement base paint of approved shade/tint in camouflaging pattern, on old previously treated plastered surfaces of walls including preparation of surfaces including brooming, scraping down smoke soot, moss, moulds, efflorscence salts, trading oil, stopping/filling all holes and cracks with white cement based wall care putty to achieve smooth finish complete all as specified and as directed.
Material and labour for two coats of cement base paint of approved shade/tint in camouflaging pattern over a coat of alkali resistant primer over white cement based wall care putty to achieve smooth finish, on new plastered surfaces of walls including preparation of surfaces brooming, scraping down smoke soot, moss, moulds, efflorscence salts, trading oil, stopping/filling all holes and cracks complete all as specified and as directed.
Material and labour for two coats of Oil bound distemper of approved shade/tint,over a coat of primer, on newly plastered surfaces of walls including preparation of surfaces complete all as specified and as directed.
Material and labour for two coats of exterior acrylic emulsion paint of approved shade/tint,over a coat of primer, on newly plastered surfaces of walls including preparation of surfaces complete all as specified and as directed.
Material and labour for two coats of exterior acrylic emulsion paint of approved shade/tint, on old previously treated plastered surfaces of walls including preparation of surfaces complete all as specified and as directed.
Material and labour for three coats of white wash as in ceiling, on newly plastered surfaces of walls including preparation of surfaces complete all as specified and as directed.
Material and labour for two coats of synthetic enamel paint over one coat of red oxide primer on new steel and iron surfaces, of any description including preparation of surface over 10cm width or girth complete all as specified and as directed.
Material and labour for two coats of synthetic enamel paint on old treated steel and iron surfaces, of any description including preparation of surface over 10cm width or girth complete all as specified and as directed.
Material and labour for two coats of synthetic enamel paint on old treated wood and wooden based surfaces, of any description including preparation of surface over 10cm width or girth complete all as specified and as directed.
Material and labour for two coats of synthetic enamel paint on new steel and iron surfaces, of any description including preparation of surface over 10cm width or girth complete all as specified and as directed.
Excavation in trenches not exc 1.5m wide and not exc 1.5m in depth for foundation etc or for walls, shafts, manholes not exc 10 Sqm on plan or for laying pipes/cables etc and getting out, in soft/loose soil complete all as directed
Returning filling in including spreading leveling watering and well ramming in layers not exc 25 cm thick each complete all as specified and as directed.
Removal of surplus soil to a distance not exc 500 mtrs & depositing where directed at a level not exc 1.5 mtrs above the starting point complete all as specified and as directed.
Material and labour for Sand cushioning to cable with a layer of sand 8 cm deep before laying the cable and 15 cms deep after the cable (punned down to 18 cms depth after laying and stretching of cable ) complete all as specified and as directed.
Supply and laying sub class 'B' bricks old sizes over the underground HT/LT cable, laid dry & flat abutting each other with width equal to length of bricks for protection of cable after taking down old covers as exist at site complete all as specified and as directed.
Supply and fixing GI pipe 40 mm bore , light grade as in trenches, under road, fixed to wall, with fixing arrangement along the pole, under floor etc including taking down of old pipe complete all as specified and as directed .
Supply and fixing GI pipe 50 mm bore , light grade as in trenches, under road, fixed to wall, with fixing arrangement along the pole, under floor etc including taking down of old pipe complete all as specified and as directed .
Supply and fixing GI tubing 50mm dia, medium grade embedded in PCC block complete all as specified and as directed. Note :- PCC block shall be measured and paid seperetely.
Supply and fixing GI pipe 80 mm bore , light grade as in trenches, under road, fixed to wall, with fixing arrangement along the pole, under floor etc including taking down of old pipe complete all as specified and as directed . Note for srl No.99 to 102:- Excavation and earth work shall be measured and paid separately.
Supply and fixing aluminium strip 25x3 mm on FRP insulator fixed on wall/MS sheet or floors including connecting to lightening arrester/ earthing/ test point after taking down/out strip as existing at site complete all as specified and as directed. Note :- Strip should be brazed/welded at each joint
Supply and fixing air termination copper rod 12 mm dia, 300mm long after taking down/out rod as existing at site complete all as specified and as directed.
Supply and fixing gun metal test point terninal block,size 75x75x25 mm, drilled and screwed inlcuding 3 Nos 8 mm dia 25 mm long hexagonal head screw after taking down point as exist at site complete all as specified and as directed.
Supply and fixing in replacement MCB DB SPN 4 way, factory made, IP- 43 protection class metal, double door with 200 Amp rating bus bar 240/430V for fixing of MCBs/Isolators/RCCBs etc complete all as specified and as directed.
Supply and fixing in replacement MCB, SPN, 6 to 32 Amps, B curve, 10 kA capacity, 240 volts finger proof terminal , bi-connect terminal label holder 35 Sqmm terminal capacity including sliding shutter large two position dolly to be fixed DBs complete all as specified and as directed.
Supply and fixing in replacement MCB, SP, 6 to 32 Amps, B curve, 10 kA capacity, 240 volts finger proof terminal , bi-connect terminal label holder 35 Sqmm terminal capacity including sliding shutter large two position dolly to be fixed DBs complete all as specified and as directed.
Supply and fixing cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot,drilling holes for bolts, in any shape or size as indicated or directed with and including applying two coats of synthetic enamel paint over a coat of red oxide primer after taking down of cross arms as existing at site complete all as specified and as directed.
Supplying, installing & testing of sirens electronic type horizontal single stage continous normal operation for alteat 50 minutes with sound level 65 DB to 120 DB measured at 1.5 Mtr with sound output variation of + 5 DB , 1000 mtr range including single phase DOL starter of suitable capacity and necessary electric connection from DB to sirens with FRLS copper conductor cable complete all as specified and as directed.
Supplying, errectioning and commissioning 12.5 meter high mast tower (adjustable type) totally hot dip galvanised steel and suitable withstand 50 mtr per second wind velocity and comprising of head frame, stain less steel wire rope, 6mm dia in strand construction 3/2 rope system, suitable with galvanised linear lantern carriage arrangments with and including 150 watt LED flood light fittings ( 06 Nos) having not less than 100 lumen/watt output, input voltage range 120-170 volts, supported with LM 79/80 report from NABL accredited and govt approved independent lab for each lot of fitting die cast aluminum alloy housing with name/logo of manufacturer embossed on every fitting, IP-66 protection, auto cut off at voltage exceeding 300 volts and auto power on after cut off with time delay of not exceeding 60 Seconds, power factor not less than 0.95, surge protection 5 KV internal and 10 KV external, driver current not exceeding 700 mA with content current and constant voltage driver efficiency not less than 85% SEL V 60 Volts DC with secondary optic lense for each LED, LED CCT 5700 + 300 ANSI BIN with copy of letter of association from manufacturer including lightening final, in built motor, 3 core 4 Sqmm flexible EPR /PCR multi stranded copper conductor round trailing cable with heavy duty industrial plug & socket for easy disconnection etc complete all as specified and as directed.. Note : - (i) The height of tower will be considered form the finished level for apron. (ii) The rates quoted shall include constrction of RCC foundation and necessary earth work according to mast height including grouting of anchoring bolts in foundation (iii) The rate quoted shall include for provn of in-built electric motor tool including accessories for lowering & raising of lantern. (iv) Luminaries with control boxes , 3 core 4 sq mm copper cable , lightening arrester with spike, Aviation obstruction lights are deemed to be included in unit rate quoted. (v) The structure should be suitable for loading as per IS 875 (Part 3) 1987.
Supply and fixing copper conductor flexible cable with PVC insulator multi-stranded 2x2.5 sqmm 1100 Volt including making neceessary connections to make it functional after taking down cable as exist at site complete all as specified and as directed.
Supplying, laying, jointing, testing and commissioning under ground electric cable XLPE 1100 Volts grade, heavy duty, PVC insulated screened PVC beeded GI steel strip armoued electric power cable with stranded aluminium conductor, of cross section area 6 Sqmm 2 core as in trenches over brick and sand cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape complete all as specified and as directed.
Supplying, laying, jointing, testing and commissioning under ground electric cable XLPE 1100 Volts grade, heavy duty, PVC insulated screened PVC beeded GI steel strip armoued electric power cable with stranded aluminium conductor, of cross section area 35 Sqmm 3.5 core as in trenches over brick and sand cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape complete all as specified and as directed.
Supplying, laying, jointing, testing and commissioning under ground electric cable XLPE 1100 Volts grade, heavy duty, PVC insulated screened PVC beeded GI steel strip armoued electric power cable with stranded aluminium conductor, of cross section area 70 Sqmm 3.5 core as in trenches over brick and sand cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape complete all as specified and as directed.
Supplying, laying, jointing, testing and commissioning under ground electric cable XLPE 1100 Volts grade, heavy duty, PVC insulated screened PVC beeded GI steel strip armoued electric power cable with stranded aluminium conductor, of cross section area 120 Sqmm 3.5 core as in trenches over brick and sand cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape complete all as specified and as directed.
Supplying, laying, jointing, testing and commissioning under ground electric cable XLPE 1100 Volts grade, heavy duty, PVC insulated screened PVC beeded GI steel strip armoued electric power cable with stranded aluminium conductor, of cross section area 16 Sqmm 4 core as in trenches over brick and sand cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape including taking down of old cable complete all as specified and as directed.
Supplying, laying, jointing, testing and commissioning under ground electric cable XLPE 1100 Volts grade, heavy duty, PVC insulated screened PVC beeded GI steel strip armoued electric power cable with stranded aluminium conductor, of cross section area 150 Sqmm 3.5 core as in trenches over brick and sand cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape including taking down of old cable complete all as specified and as directed. Note for srl No 113 to 118 :- Excavation and earth work, GI pipe, brick and sand cushioning shall be measured and paid separately.
M&L for cable path/route indicator made out of MS sheet 3mm thick os size 300x250mm spot welded with angle iron of size 40x40x5mm thick, 750mm long embedded in PCC 1:3:6 type C1 using 20mm graded mechanically crushed stone aggregate including applying two coats of synthetic enamel black paintover a coad of red oxide primer with and including writing grade of cable and size with white paint complete all as specified and as directed.
Boring to existing road/path/hardstanding etc by trenchless technology using ultra sounding technique and necessary machine for passing pipe upto 80mm bore for passing cable including making good the disturbed surfaces and removal of debries to distance n.exc 500 mtr complete all as specified and as directed.
Supply and fixing in replacement energy efficient LED street light fitting ,Beamer, 90 watt,input voltage 230 VAC, 50 Hz with ingress protection -IP 65 with CRCA housing, min 50000 burning hrs with and including security light bracket made of GI Pipe, light grade,40 mm dia bend to shape, of length 1.5 mtr long including flat iron clamp made of FI 50x6 mm , nuts, bolts, washers etc duly painted with two coats of synthetic enamel paint over a coat of red oride primer including connecting with twin core twisted flexible copper conductor cable of suitable size and making necessary connections to make it functional complete all as specified and as directed. Note:- LED fitting should have PF 0.95,CRI>70,L70,THD> 20.
Supply and fixing 25 KW equally distributed over 3 phase (7 KW/Phase) automatic street light switch using nature switch for automatic switching of street light based on LUX level of natural light,infrared sensor based on nature switch along with contactor 63 amp per phase, MCB SP for input, out put 100 amp, wiring for main load 16 sqmm copper be enclosed in pole/wall mounted enclosure made out of rust proof, electric shock proof, termite proof and FR grade SMC junction box (sintex make) conforming to IP 54 including connecting with twin core twisted flexible copper conductor cable of suitable size and making necessary connection to make it functional complete all as specified and as directed.
Supply and fixing in replacement thermoplastic cable junction box with 02 Nos PVC gland, weather proof with IP 67 protection for outdoor installation with knock outs for cable entry of size 355 x 255 x122 mm hinged type with 4 Nos aluminium bus bar of size 25mmX6mm,8 Nos terminals with nuts and bolt mounted on bus bars,MCB 10 Amp rating 01 No including making connections with existing cable duly fixed with MS clamp made out of FI 40 x 3 mm thick with nuts & bolts to make it functional complete all as specified and as directed.
Supply and fixing in replacement energy efficient LED flood light fitting, 120 watts,input voltage 230 VAC, 50 Hz with ingress protection -IP 65 with CRCA housing including fixing arrengments like clamps, nuts, bolts,washers and making necessary connection to make it functional complete all as specified and as directed. Note:- LED fitting should have CRI > 70, PF>0.95, Min 50000 burning Hrs, THD> 20
Supply and fixing in replacement energy efficient LED flood light fitting,70 watts,input voltage 230 VAC, 50 Hz with ingress protection -IP 65 with CRCA housing including fixing arrengments like clamps, nuts, bolts ,washers and making necessary connection to make it functional complete all as specified and as directed. Note:- LED fitting should have CRI > 70, PF>0.95, Min 50000 burning Hrs, THD> 20
Supplying, installing, testing and commissioning diesel engine driven generating set 415 V, 3 phase, 4 wire as per BS 5514/IS-10002 complete with standard control panel, of capacity continuous rating 100 KVA/80 KW at NTP conditions with acoustic enclosure and canopy cover considering all derating factors and comprising of the following :- (a) ALTERNATOR : Self regulated with brushless self excitation 100 KVA 415 V, 3 phase, 4 wire,50 HZ,0.8P.F.,1500 RPM with voltage variation +/- 2.5% of rated voltage from no-load to full-load foot mounted, screen protected drip proof type with class 'F' insulation, closed coupled single bearing alternator, with necessary controls as recommended by the manufacturers, conforming to BS-5000/IS-4772, capable of supplying unbalanced load. (b) Engine : Multi/cylinder,compression ignition, heavy duty,compact diesel engine liquid cooled with standard accessories, all as per BS-5514/ISO-3046,1500 RPM,control gauges, RPM/Hours meters etc; shaft H.P. suitable for generating application and capable of giving an output of 100 KVA/80 KW for coupled alternator under NTP conditions, complete with following:- (i) Flywheel housing with flywheel to suit closed coupled single bearing alternator. (ii) Air-cleaner dry type with vacuum indicator. (iii) Fuel pump and fuel piping 15mm M.S. pipe with bends, flanges etc. (iv) Fuel filter with water separator and filter element. (v) Lub-oil filter with filter element (vi) D.C. starter 12 volts. (vii) Storage Batteries of suitable voltage and ampere-hours as recommended by the manufacturers. (viii) Residential silencer as per CPCB norms (x) Supporting/ fixing arrangement for muffler with celiling through antivibration pads. (xi) Engine overspeed stop/trip switch. (xii) Radiator with fan. (xiii) Dynamo for battery charging. (xiv) Corrosion inhibitor coolant.
(xv) Engine control panel electronic digital display type consisting of battery voltage indicator, lub oil temp and pressure gauges coolant water temp gauge, RPM indicator cum hour meter etc.(xvi) Safety controls for alarm due to high water temp and low lub oil pressure. (xvii) Any other devices/accessories recommended/ supplied by the manufacturers as standard eqpt. (c ) SKID : The engine and alternator will be coupled,aligned and mounted on a specially designed common base frame fabricated from M.S.channels of suitable cross sectional area,length with bottom drilled holes suitable for and including supplying and fixing anti vibration pads of required size and numbers as recommended by the manufacturer for mounting of 100 KVA/80 KW D.G. set.
(d) AMF Panel : AMF panel shall be factory made indoor cubical type front openable fabricated from CRCA steel sheet 1.6 mm thick as per manufacturer specification of Diesel Engine suitable for DG Set of capacity 100 KVA grouted in floor by providing PCC 1:2:4 type B-2 foundation as per manufacturers recommendations and consisting of the following :- (i) Contactor ML of suitable capacity. (ii) Aluminium bus bar of capacity 200 Amps (04 Nos) for phase and neutral.(iii) Sensitivity relay set unit with auxiliary relay CT's. (iv) Electronic latch circuit with tripping indication. (v) Instantneous tripping device suitable for complete panel over current 0.5 Amp. (vi) Reset facilities for complete protection of AMF Panel. (vii) Self squential starting relay unit 12 volts DC complete with alarm and power contactor. (viii) Electronic timer 220 Volts for main contactor with 1 No NC auxiliary contactor. (ix) Electronic timer 220 volts for fuel cut off operation for with 1 No NC auxiliary contactor. (x) Battery charging unit 12 volts 10 amp complete with digital volt metre & Amp metre.
(g) PCC/RCC foundation as per manufacturers own design/ Or as per directions of GE/Engineer-in- charge. (h) Documents : Three sets of following documents :- Maintenance and operation manuals for engine and alternator, spare parts catalogue, warranty/test certificates, schematic diagrams of control panels. (j) other items : List of tools and two years normal maintenance spares as per manufacturers recommended lists, duly priced, item wise. Notes : (i) Contractor will satisfactorily conduct load test of DG set for 12 hours including run on 10% overload for 1 hour. (ii) Testing equipment will be arranged by the contractor. (iii) Fuel/oil required for load test shall be arranged by the contractor and cost thereof is deemed to be included in the lump sum amount quoted by the contractor.(iv) AMF panel and DG set shall be procured from same OEM i.e make of both shall be same..
Material and labour for earthing complete with galvanized steel earth plate 60 cm X 60 cm X 6 mm thick buried vertically in ground to depth not less than 2.25 metres below ground level, with top edge of earth plate not less than 1.5 m below ground level, connected to GI earth lead strip 32x6 mm upto 7.5 mtrs long by means of bolts, nuts, check nuts and washers of galvanized iron and connection to earthing test point & earth dolly including watering pipe GI 20 mm bore, light grade including protection pipe GI medium grade 40mm bore , wire mesh, funnel,lugs, salt, charcoal dust, excavation and refilling pit chamber with PCC 1:2:4 type B1 using 20 mm graded mechnically crushed stone aggregates , RCC 1:2:4 type B-1 using 20 mm graded mechnically crushed stone aggregates pit cover slab 50 mm thick reinforced with 8 mm dia TMT bars @ 15 cm c/c both ways including necessary form work all as shown in electrical plate No 3 of SSR part-I (2009), including testing on completion including taking down of existing earthing as exists on site complete all as specified and as directed. Note :-- (i) Any variation in length of earth lead and protection pipe of earth lead shall be adjusted through DO. (ii) On testing if the earth resistance is not obtained, earthing will be generated at NO extra cost ,till the desired earth resistance is obtained.
Deduct total amount of Credit Rs 233480.00
Krishan Kumar Goel
Sham Sunder Bansal
sagar associates
Baljeet Singh Choudhari
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .