Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.9 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹47.8 L+₹5.9 L (14.0%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | Rejected-Technical | - | Rejected-Technical Technically not qualified |
| Sl No | Description | Qty | Unit | YOOSAF K A L1 | ASKIN ELECTRIC P. LTD L2 |
|---|---|---|---|---|---|
| 1.00CIVIL WORKS | |||||
| 1.01 | OD229996/2025-2026 Supply, installation, testing and commissioning of Wall Mounting Type KSEBL Meter Board suitable for 415 V, Three Phase, 4 Wire 50 Hz AC supply system having sufficient front surface area fabricated from CRCA sheet steel of 1.6mm to 2.0 mm thick for frame works and covers, Powder Coated in approved shade etc. complete as required. The Meter Board shall conform to KSEBL standards and it shall only be manufactured/supplied after getting approval from the Engineer-in-charge and the
Consultant. COMPONENTS
1 Nos - Provision for Fixing Three Phase Energy Meter
1 Nos - 63A Bakelite Fuse Units with HRC Fuse of Suitable Rating
1 Nos - 63A Neutral Link
1 Nos - 40A to 63A 10kA 4P C Curve MCB | 1 | no | 14,000 ₹14,000 Lowest | 17,500 ₹17,500 |
| 1.02 | 90.11.1.15 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) | 2 | each | 9,500 ₹19,000 | 7,500 ₹15,000 Lowest |
| 1.03 | 90.11.1.11 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43) | 4 | each | 1,500 ₹6,000 Lowest | 4,750 ₹19,000 |
| 1.04 | 2.3.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door | 4 | each | 1,200 ₹4,800 Lowest | 2,750 ₹11,000 |
| 1.05 | 2.3.2 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double door | 1 | each | 3,200 ₹3,200 | 3,000 ₹3,000 Lowest |
| 1.06 | 2.13.1 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps | 6 | each | 850 ₹5,100 Lowest | 1,250 ₹7,500 |
| 1.07 | OD230001/2025-2026 Supply and fixing of the following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current of 100 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. complete as required
40 amps | 2 | no | 4,500 ₹9,000 | 3,950 ₹7,900 Lowest |
| 1.08 | 2.15.2 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps | 4 | each | 350 ₹1,400 Lowest | 3,750 ₹15,000 |
| 1.09 | 2.10.4 Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole | 4 | each | 1,200 ₹4,800 Lowest | 1,350 ₹5,400 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
2 Jul 2026, 3:00 pmClosed
Manager (Electrical Projects)
KEL MAMALA KOCHI
TENDER FOR THE WORK OF ELECTRICAL RENOVATION WORKS OF VARIOUS SCHOOLS IN KASARGOD DISTRICT PANCHAYAT GOVERNMENT HIGHER SECONDARY SCHOOL PANDI,GOVERNMENT VOCATIONAL HIGHER SECONDARY SCHOOL KARADKA, GOVERNMENT VOCATIONAL HIGHER SECONDARY SCHOOL
2026_KEL_857662_1
KEL/KMEP/EPROC/081/2026-27
Open Tender
Electrical Works
Item Rate
KEL MAMALA KOCHI
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,500
₹50,000
Yes
17 Jul 2026
25 Jun 2026
3 Jul 2026
25 Jun 2026
2 Jul 2026
25 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1CIVIL WORKS | |||||
| 1.01 | OD229996/2025-2026 Supply, installation, testing and commissioning of Wall Mounting Type KSEBL Meter Board suitable for 415 V, Three Phase, 4 Wire 50 Hz AC supply system having sufficient front surface area fabricated from CRCA sheet steel of 1.6mm to 2.0 mm thick for frame works and covers, Powder Coated in approved shade etc. complete as required. The Meter Board shall conform to KSEBL standards and it shall only be manufactured/supplied after getting approval from the Engineer-in-charge and the
Consultant. COMPONENTS
1 Nos - Provision for Fixing Three Phase Energy Meter
1 Nos - 63A Bakelite Fuse Units with HRC Fuse of Suitable Rating
1 Nos - 63A Neutral Link
1 Nos - 40A to 63A 10kA 4P C Curve MCB | 1 | no | - | - |
| 1.02 | 90.11.1.15 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) | - | each | - | - |
| 1.03 | 90.11.1.11 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43) | 4 | each | - | - |
| 1.04 | 2.3.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door | 4 | each | - | - |
| 1.05 | 2.3.2 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double door | 1 | each | - | - |
| 1.06 | 2.13.1 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps | - | each | - | - |
| 1.07 | OD230001/2025-2026 Supply and fixing of the following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current of 100 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. complete as required
40 amps | - | no | - | - |
| 1.08 | 2.15.2 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps | 4 | each | - | - |
| 1.09 | 2.10.4 Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole | 4 | each | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.41 MB
BOQ_1449790.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .