Loading…
Loading…
Tender ID
Tender Value
₹24.4 L
EMD Value
₹61,100
Closing Date
19 Jul 2025, 11:00 pmClosed
Karnataka Power Corporation Limited
Repair/Rectification of HT/LT overhead line and Rewinding/Repair of Ceiling, Wall mounting and Pedestal fans for a period of 12 months
KPCL/2025-26/PS/WORK_INDENT3208
KPCL/2025-26/PS/WORK_INDENT3208
Open
Power stations
Two Tender Document System(Two Cover)
KPCL Executive Engineer PPS Office RTPS Raichur
₹620
₹61,100
5 Jul 2025
5 Jul 2025
21 Jul 2025
12 Jul 2025
Repair/Rectification of HT/LT overhead line and Rewinding/Repair of Ceiling, Wall mounting and Pedestal fans for a period of 12 months
Re-winding /Repair/Replacement of bearings, Bushes and shafts etc., for Ceiling Fans /Wall mounting Fans/Exhaust Fan in RTPS Plant.
Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc., complete (In soil ordinary)
Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc., complete( In soil hard)
Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm all-round the cable.
Supply & laying of Burnt Bricks.
Supplying GI Pipe 65MM
Labour Charges for Laying GI Pipe
Supplying of RCC Pole - 9 M Long, 145 Kg WL (Dwg. No. BESCOM/GM/QS&S/02 Dt: 24.11.2018) as per IS - 785,
Erection of RCC/PSC poles 9 to 10 mtr long but in a pit of 1.8 mtr deapth. Labour Charge Complete (Including Erection, Excavation & Fixing).
Supplying of 11KV cross arm - GI with HT Top support (Glass rein forced hot pressed SMC compound)
Supply of LT 4 Pin Cross Arm - GI
Supplying Guy Wire & GI Wire as per IS-2141;7/10 SWG Guy Wire (7/3.251 mm Dia), Std Wt: 680 Kg/KM
Supply of Guy Clamp - GI
Supply of Turn Buckle (GI) (Dwg No. BESCOM/GM/QS&S/07 Dtd 24.11.2018)
Supply of Anchor Rod using 12 mm rounds/Guy Rod - GI
Supply of Insulator as per IS-1445 for Ceremic, IS-7935 for GI Pin, IEC-61109 for Polymeric;11 kV, 5 kN Composite/Polymeric Pin Insulator (24 mm dia FRP Rod)
Supply of Insulator as per IS-1445 for Ceremic, IS- 7935 for GI Pin, IEC-61109 for Polymeric;1.1 kV Polymeric Pin Insulator
Supplying of No. 15 strain insulaters.
Supplying of Insulator as per IS-1445 for Ceremic, IS-7935 for GI Pin, IEC-61109 for Polymeric: 11 kV, 45 kN Polymeric Insulator.
Supplying of No. 8 strain insulaters.
Digging of Pit 1.8 Mtr depth for errection of 9 to 10 Mtr Long Steel/RCC/PSCC supports as per approved Drawing.Ordinary soil.
Digging of Pit 1.8 Mtr depth for errection of 9 to 10 Mtr Long Steel/RCC/PSCC supports as per approved Drawing.Hard soil
Digging of pit for GUY SET . Ordinary soil
Digging of pit for GUY SET . Hard soil
Supply of 11 kV, DOLO Cutout REC Specification (Dwg No. BESCOM/GM/QS&S/20 Dtd 24.11.2018).each 3 nos.set
Fixing of DOLO, GOS, LA, Fuse Board, Service Mains, Spacer, Insulator Etc.,:Fixing DOLO Cutout/Horn Gap Fuse including fixing of cross arm and wiring.set of 3 nos
Supplying of 11KV, 200 Amps single break GOS (Dwg. No. BESCOM/GM/QS&S/23 Dt: 24.11.2018.
Fixing of DOLO, GOS, LA, Fuse Board, Service Mains, Spacer, Insulator Etc.,:Fixing of GOS including wiring (11 kV Single Break 200 Amps)
Supplying and making 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations- INDOOR & OUTDOOR JOIN...
Dismantling of 16M /30M high mast, lighting fitting using Hydro/Crane
Replacement of steel wire rope by new stainless steel wire rope 80 Mtr 6mm with accessories Make:Usha martin /TATA
Replacement of 5 core 6Sq mm flexible copper cable (40 Mtr for each Mast) Make:Polycab/Havel /KEI/V guard only
Release and reconditioning of high mast light fitting, Repair/rewinding /reconditioning and replacement of Motor and gear wheel, Re-erection of High mast light etc
Supplying of ACSR conductors as IS 398 (Part-2/1996) Rabbit ACSR (6/3.35mm Al + 1/3.35mm St.), Std. Wt. : 214 Kgs/Km.
Releasing & Restringing of loose spans, binding, straightening of inclined Pole etc.Straightening of Slant/Bent Pole.75% of the 8 Mtr. RCC Pole erection charges .(1113*75%=834.75)
Painting of existing street light pole after scrapping the old paint and painted with suitable colour enamel/Silver paint including coping/footing of the pole. 8 m and above street light pole.
Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matt...
Stringing of conductor Squirrel, Weasel, binding of conductor on each insulator and dead ending on strain or disc/strain insulator by means of clamps.for Rabbit ACSR.
Emergency power supply line faults/ break down works in RTPS Plant for 440V LT /6.6KV, 11KV HT line/Cable works. Separate Man Power to be deployed as when & require (2 Electricians + 3 Ma...
Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit sh...
Supplying and Fixing of........mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GI or rail or RCC pole / ...
Supplying of 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-...
Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required.In existing trench/duct.95 sqmm to150Sqmm ( Separate Labour Shall ...
Vehicle charges(including all aplicable taxes & GST 5%)
Labour charges for HT/LT line maintenance
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .