| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 CrAccepted-AOC N A | ₹2.7 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹2.7 Cr+₹4.7 L (1.75%)Rejected-Finance 9 8 B THENGUMTHARAVIL MLA ROAD PANANGAD PO KOCHI 682506 | KOCHI | ERNAKULAM | KERALA | 682506 | ₹2.7 Cr+₹4.7 L (1.75%) | L2 | Rejected-Finance Rejected being L2 |
| 3 | L3₹2.9 Cr+₹16.4 L (6.09%)Rejected-Finance 368 MAHESHPUR SECTOR 21 PANCHKULA HR 134112 | PANCHKULA | PANCHKULA | HARYANA | 134112 | ₹2.9 Cr+₹16.4 L (6.09%) | L3 | Rejected-Finance Rejected being L3 |
| 4 | L4₹3.0 Cr+₹31.3 L (11.6%)Rejected-Finance KORAMANGALATH HOUSE TOMY LANE SOUTH PANAMBILLY NAGAR KADAVANTHRA P O KOCHI 682 020 | KOCHI | ERNAKULAM | KERALA | 682020 | ₹3.0 Cr+₹31.3 L (11.6%) | L4 | Rejected-Finance Rejected being L4 |
| 5 | Rejected-Technical 17 1624A MUMDAMVELI KOCHI 682 507 | ERNAKULAM | KERALA | 682507 | - | - | Rejected-Technical Does not meets the criteria |
Tender Value
Refer Docs
EMD Value
₹3.8 L
Closing Date
18 Dec 2020, 6:00 pmClosed
CE NW Kochi
Kattaribagh, Naval Base, Kochi-682004
PROVN OF FIRE DETECTION ALARM AND FIRE HYDRANT SYSTEM AT MO(K) KOCHI
2020_MES_366559_3
890961
Open Tender
Civil Works
Lump-sum
365 days
Kochi
As per NIT
7 documents required · 7 mandatory
₹2,000
GE NS Kochi
₹3.8 L
Yes
12 Feb 2021
26 Nov 2020
22 Dec 2020
26 Nov 2020
18 Dec 2020
3 Dec 2020
26 Nov 2020 - 30 Nov 2020
Amount
LIST OF WORKS
Schedule A Part I to Part VIII
Total amount of Sch 'A' part-I (Buildings & Structures)
Total amount of Sch 'A' part-II (Excavation and Earth work)
Total amount of Sch 'A' part-III (Internal Electrification)
Total amount of Sch 'A' part-IV (Internal Water Supply)
Total amount of Sch 'A' part-V (External Electric Supply)
Total amount of Sch 'A' part-VI (External Water Supply)
Total amount of Sch 'A' part-VII (Fire Fighting System)
Total amount of Sch 'A' part-VIII (Road/Path)
Sch 'A' Part- IX (MISCELLANEOUS) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Boring for cast-in-situ bored piles of 500mm dia to any depth through any type of soil/strata by DMC method using bentonite slurry including removal of bored materials to place outside MD land all as specified and as directed Note:-The rate shall include mobilisation,erection,dismantling and demobilisation of equipment for pile boring including all labours and material. Nothing extra shall be payable for mobilisation of equipment seperately.
Boring for cast-in-situ bored under reamed piles of 500mm dia 12mm depth for pump house to any depth through any type of soil/strata by DMC method using bentonite slurry including removal of bored materials to place outside MD land all as specified and as directed Note:-The rate shall include mobilisation,erection,dismantling and demobilisation of equipment for pile boring including all labours and material. Nothing extra shall be payable for mobilisation of equipment seperately.
RCC with ready mix concrete(RMC) M30 grade in cast in situ bored pile with minimum cement content 400kg/cum of any length/any sections complete all as specified and as shown on drg including non destructive integrity test on all pile as per IS 2911 part IV. Note:-(i) Reinforcement will be measured and paid separately under relevant items
RCC with ready mix concrete(RMC) M30 grade in pile cap , grade beam & tie beam complete all as specified and shown on drg. Note:-(i) Reinforcement will be measured and paid separately under relevant items
Providing TMT bars (CRS/HCRM/CRM) in reinforcement 10mm dia and over for bored piles of any length and any dia all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/required shape complete all as specified and shown on drgs.
Providing TMT bars (CRS/HCRM/CRM) in reinforcement 10mm dia and over for grade beam/tie beams and pile caps of any length and any dia all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/required shape complete all as specified and shown on drgs.
Providing TMT bars (CRS/HCRM/CRM) in reinforcement 5mm dia and over up to and including 16mm dia confirming to IS-1786 as in Helical/stirups for pile cut to length, bend to required shape, cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/required shape complete all as specified and shown on drgs.
Providing TMT bars (CRS/HCRM/CRM) in reinforcement 5mm dia and over up to and including 12mm dia as in stirups for pile caps and grade beams including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/required shape complete all as specified and shown on drgs.
PCC (1:4:8) type D2 using 40mm graded stone aggregate for concrete layer below pile caps/grade beams and foundation complete all as specified and shown on drgs.
Providing testing equipment & load and testing of 500mm dia bored pile for DMC pile (Initial Load test) all as per IS including removing the testing equipments from site after testing is completed all as specified and directed.
Providing testing equipment & load and testing of 500mm dia pile for DMC pile (Routine Load test) all as per IS including removing the testing equipments from site after testing is completed all as specified and directed.
Providing testing equipment & load and testing of 500mm dia bored pile for under reamed pile (Initial Load test) all as per IS including removing the testing equipments from site after testing is completed all as specified and directed.
Providing testing equipment & load and testing of 500mm dia pile for under reamed pile (Routine Load test) all as per IS including removing the testing equipments from site after testing is completed all as specified and directed.
Conducting standard penetration test all as per IS-2131 at levels and locations as directed for 500mm dia cast in situ bored piles all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep or area not exceeding 10 sqm on plan in soft/loose soil including bailing out/pumping out water on account of spring/rain or any other causes using any method as required and as directed by Engr-in-Charge for pile caps/plinth beams,raft foundation etc all as specified and shown on drawings.
Returning filling in around pile cap, plinth beams, raft foundation etc using excavated soil including spreading levelling and well ramming in layers not exc 25 cm thick all as specified and directed.
Removal of surplus soil to a distance not exceeding 50m deposited whereever directed at a level not exc 1.5 m above starting point .
Formwork to sides of pile caps , grade beams rough finished surface of concrete flat all as specified .
Internal Electrification:-Ceiling fan 1400mm sweep copper wound having minimum service valu of 4.1m^3/min/W and min air delivery 245m^3/min , including fixing of down rod and connecting up complete with and including three core flexible PVC insulated multi stranded copper conductor cable of size 0.5 Sq mm from ceiling rose/ connector to fan complete all as specified and directed. Make :- Bajaj/Crompton/Usha
Exhaust fan heavy duty 300 mm sweep 230 Volts AC 50 Hz, 1400 rpm, with high efficient heavy duty motor and die cast aluminium rotor mounted on two ball bearings, aero dynamically countered blades, rigid frames with rubber mountings etc for silent operation, including factory fabricated powder coated aluminium louvers, including connecting up from ceiling rose with 3 core flexible copper cable, PVC sheathed of size 1.5 sqmm, complete all as specified and directed at site.Make :- Bajaj/Crompton/Almonard
LED Batten light fitting with extruded aluminium housing 4 feet long, with all accessories and integrated electronic driver,20W Make:- Philips model smart bright Cat part No BN021C LED20S PSU CW GR S2 or eqvt in Wipro/Osram/GE.
LED street light fitting with pressure die cast aluminium housing and acrylic cover as diffuser, having IP 66 protection of 30 Watt complete including fixing with GI Bracket made of 43mm outer dia GI Pipe including fixing clamps etc and wiring from junction box/ceiling rose with 3 core flexible copper wire, 1.5 sqmm complete all as specified and directed. Make:- Philips model Vistaglow Cat part No BRP046 LED30 CW MR S1 PSU GR or eqvt in Wipro/Osram/GE.
MCB SP 06 to 32 Amps "C" Series
MCB SPN 32 Amps "C" Series
Internal Water Supply:- Angular stop cock, chromium plated, cast copper alloy, screwed down, screwed for CPVC pipe 15 mm dia bore complete all as specified and directed. Make :- Jaquar/Cera/Hindware
Health faucet/ Hand shower with 8 mm dia, wall hook and easy flexible tube in crome finish1.5m long with nuts complete all as specified and directed.all as specified and directed. Make :- Jaquar/Cera/Hindware
FIRE FIGHTING SYSTEM:- Supplying, Installation, Testing and Commissioning of Electric driven main fire pump suitable for automatic operation and consisting of following: complete in all respect as required as per the technical specification. (a) Horizontal type, centrifugal, End Suction pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg/sq.cm. at highest and farthest outlet at specified flow of 2850 LPM at 105m. head conforming to IS 1520. (b) Suitable capacity for driving the pump as approved by GE. Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads. Includes as per standard size of PVC insulated Copper conductor cable through the medium grade PVC Pipe Standard Size. Make:- Kirloskar / Crompton Greaves / ABB Note :- Contractor shall submit the performance curve alongwith design details of pumps to GE for approval.
Supplying, Installation, Testing and Commissioning of Diesel engine driven Standby Pump suitable for automatic operation and consisting of following: complete in all respect as required as per the technical specification. (a) Horizontal type, centrifugal,End Suction pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg/sq.cm. at highest and farthest outlet at specified flow of 2850 LPM at 105 m. head conforming to IS 1520. (b) Diesel engine of suitable, capacity (as approved by GE) to draive the pumps, 1500 RPM, water cooled with radiator, conforming to relevant BS & IS standard complete with auto starting mechanism, 12 volts/24 Volts electric starting equipment,2x12v 180AH Batteries and leads, Diesel Tank Fabricated from MS sheet of 4mm Thick (Minimum Capacity 300 Litres) with level indicator, Bypass line,MS Piping to diesel tank from engine, exhaust pipe extended upto 1 m. outside pump house duly insulated with 50 mm. thick glass wool with 1.0 mm. thick aluminium sheet cladding, residential silencer, instruments and protection as per specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.
Continued from item No 39:- (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration. Make for Diesel Engine :- Kirloskar / Cummins /Crompton Greaves Make for Pump:- Kirloskar/Crompton Greaves/ ABB. Note :- Contractor shall submit the performance curve alongwith design details of pumps to GE for approval.
Supplying, Installation, Testing and Commissioning of Jockey Pump suitable for automatic operation and consisting of following: complete in all respect as required as per the technical specification. (a)Horizontal type, centrifugal, pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal and flow of 180 LPM at 110 m. head conforming to IS 1520. (b)12.5 HP Squrrel cage induction motor, TEFC, synchronous speed 2900 RPM, suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads . Including as per standard size of PVC insulated Copper conductor cable through the medium grade PVC Pipe standard size complete all as specified and directed. Make:- Kirloskar / Crompton Greaves /ABB. Note:- Contractor shall submit the performance curve along with design details of pump to GE for approval.
Supply and fix Pressure Gauge 100mm dia with ball valve of pressure of 25Kg/Sqcm , 3/8" BSP bottom entry,weather proof with stainless steel internals,siphon tube and ball valve including fittings complete all as specified and directed. Make:- Hguru/Atom/Febib/Miepl/Marsh
Providing, laying, testing & Commissioning of GI Pipes, heavy duty conforming to IS 3589( 200mm and above) and 1239( upto 150mm) including all types of joints and heavy duty drop forged/fabricated fittings like elbows, tees flanges, tapers, nuts bolts, gaskets etc. laid in trenches. Pipes laid trenches shall be provided with.anti corroosive wrapping coating as per IS10221 and the rate shall be deemed to include the same. Note:- Excavation and earth work only shall be measured and paid separately. Make:- Tata / Jindal /Zenith
200mm dia
150mm dia
100mm dia
80mm dia
Providing, laying, testing & Commissioning of GI Pipes, heavy duty conforming to IS 3589( 200mm and above) and 1239( upto 150mm) including all types of joints and heavy duty drop forged/fabricated fittings like elbows, tees flanges, tapers, nuts bolts, gaskets etc. fixed on the wall / ceiling with suitable clamps etc. Rates includes painting all exposed pipes with red oxide primer and two or more coats of synthetic enamel paint of required shade complete as required. Note:Excavation and earth work only shall be measured and paid separately. Make:- Tata / Jindal /Zenith
200mm dia
150mm dia
100mm dia
80mm dia
Supply, installation, testing and commissioning of cast iron flanged sluice valve rating PN1.6 with non rising spindle, bronze/gun metal seat ISI marked complete with nuts ,bolts washer gaskets complete all as specified and directed. Make:- Kirloskar/Leader/Upadhyay
200mm dia
150mm dia
100mm dia
Supplying, installing and commissioning C.I.flanged "Y" type Strainer 200 mm dia with SS mesh,suitable flanges, nuts, bolts, gaskets etc. complete all as specified and directed. Make:Kejriwal/Kirloskar/Zoloto
Fire Hydrant landing valve type A (single head ) of 63mm dia confirming to IS 5290 complete all as specified and directed. Make: Newage/Essel/CRC
63mm dia 15 mtr long Hose Pipe (Hose Pipe shall be of synthetic fibre) confirming to IS 636 complete with male and female coupling confirming to IS 903 complete all as specified and directed. Make: Newage/Essel/CRC
Supply Installation Testing and Commissioning of Weather proof Hose cabinet for keeping One hose pipe of length 15mtrs each, branch pipe, nozzle, coupling etc of MS sheet of Thickness of 2mm complete all as specified and directed. Make:- Friends/Capital Gains
Supply, installation, testing and commissioning of Air Release Valve 25mm dia with stainless steel internal and 25 mm dia Ball valve including fittings complete all as specified and directed. Make:- Newage/ITAP/RB
Construction of brick Valve Chamber of internal dimensions 900 x900 x900mm ( bottom RCC floor of the pit should be minimum 30 cms below the bottom surface of sluice valve flange to provide sufficient working space) , bottom floor of the pit be constructed in RCC (1:2:4) 20 cms thick with 20 mm stone aggregate, inner and exposed surfaces and bottom floor of the pit should be plastered in CM (1:4) 15 MM thick. The sluice valve and other fittings should be housed in center of the pit. the vertices of the pit should in right angle and champhered .The top cover of the pit will be made out of Chequered Plate Fe 410 W grade with angle iron frame made out of MS angle 50mm x50 mmx 6 mm with galvanised steel hindges two nos ,and locking arrangements, duly painted with two coats of water resistant synthetic enamelled paint over one coat of red oxide all as specified and as directed.
FIRE ALARM SYSTEM:- Supply, installation, testing and commissioning Addressable Main Fire alarm control panel complying with BS EN 54 5 Loop panel with 99 detectors & 99 modules 7 upto 200 detectors and modules per loop complete all as specified and directed. Make:- Notifier/ Morley/ Cooper/Honeywell
Addressable type Multi-Sensor Detector with heat and smoke combination complete all as specified and directed. Make:- Notifier/Morley/Cooper/Honeywel
Addressable type Manual Call Point break glass type with Alarm LED complete all as specified and directed. Make:- Notifier/ Morley/ Cooper/Honeywel
2 core x 1.5 sqmm FRLS, PVC sheathed cable galvanised steel strip or wire armoured Multi standered copper conducter cable (Red Colour) suitable for Fire Alarm System complete all as specified and directed. Make:- Finolex/Polycab
Supply, Installation, Testing and commissioning of Network card RS 485 complete all as specified and directed. Make:- Notifier/ Morley/ Cooper/Honeywel
WMM 15 cm athick in two layers (7.5cm thick in each layer) (compacted thickeness) with coarse stone aggregate or granite spread & arolled with 8 to 10 tonne power roller, rolled & consolidated to required gradient & camber all as specified and as directed.
External Water Supply:- 75 mm bore CPVC Ball valves Suitable for CPVC pipe with necessary fittings, complete all as specified and directed. Make:- Supreme/Astral/Zoloto
EXTERNAL ELECTRIC SUPPLY:- XLPE insulated galvanised steel strip or wire armoured eletric power cable with stranded aluminium conductor 1100 V grade of size 120 sqmm 3.5 core complete all as specified and directed. Make:-Finolex/Gloster/Polycab
Supply, spreading and levelling riddled soil as earth cushioning to UG cable by using IS seive to seperate the composite/roots etc and refilling spreading in trenches as cushioning and rammed down to form a solid bed all as specified and directed at site. Note:- Punned thickness shall be measured and paid. Earth obtained from outsied MD Land.
MCCB 200 A 35 KA 4 pole with enclosure complete all as specified and directed. Make:- L&T/ABB/Schneider
T.I.John and Sons
FIRE ENVO SAFETY ENGINEERS
K.V.GEORGE AND COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .