Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.9 LAccepted-AOC | L1 | Accepted-AOC lowest | |
| 2 | L2₹15.8 L+₹1.5 L (10.7%)Rejected-Finance AIR FORCE STATION HALWARA SUDHAR LUDHIANA LUDHIANA PUNJAB 141106 | LUDHIANA | PUNJAB | 141106 | L2 | Rejected-Finance other than lowest |
| Sl No | Description | Qty | Unit | JAI DURGA CONSTRUCTION COMPANY L1 | M/S Shyam kumar mehta and co L2 |
|---|---|---|---|---|---|
| 1.00Sch 'A' | |||||
| 1.01 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed. | 10 | Cum | 150 ₹1,500 Lowest | 200 ₹2,000 |
| 2.00 | Demolition of cement concrete (unreinforced) in groung floors and pavings n.exc. 15 cm thickness (beow or above ground level) complete all as specified and directed. | 1 | Cum | 350 ₹350 | 200 ₹200 Lowest |
| 3.00 | Demolition of brickwork built in cement or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. | 12 | Cum | 225 ₹2,700 | 200 ₹2,400 Lowest |
| 4.00 | Dismantling Asbestos cement corrugated sheet in roof covering complete all as specified and directed. | 8 | Sqm | 25 ₹200 | 20 ₹160 Lowest |
| 5.00 | Excavating in post holes (or similar holes) in soft loose soil each n.exc 0.5 cum, getting out, returning, filling in and rammomg earth or broken rubble mixed with earth around, in layers not exc 25 cm, watering and removing surplus soil to adistance n. exc 50m and making good surface complete all as specified and directed. | 18 | Each | 150 ₹2,700 Lowest | 200 ₹3,600 |
| 6.00 | M&L cement concrete 1:3:6 type C2 (using 40mm graded crushed stone aggregate) as in foundation filling of posts holes complete all as specified and directed. | 2.19 | Cum | 4,950 ₹10,825.65 Lowest | 5,000 ₹10,935 |
| 7.00 | Excavating over areas n .exc. 1.5m wide and n. exc 1.5 m depth for column footing complete all as specified and directed. | 10.12 | Cum | 225 ₹2,278.12 | 200 ₹2,025 Lowest |
| 8.00 | Excavating in trenches, n. exc. 1.5m wide and n.exc. 1.5m in depth for foundation, etc or for shafts well, cesspits, manhols, pier holes etc, n exc 10 sqm on plan and n.exc. 1.5m in depth and getting out complete all as specified and directed. | 23.4 | Cum | 150 ₹3,510 Lowest | 250 ₹5,850 |
| 9.00 | M&L for hardcore of broken stone boulders of gauge n.exc. 63mm, deposited, spread and levelled in layers n.exc. 15cm thick, watered and rammed to a true surface complete all as specified and directed. | 1.01 | Cum | 1,650 ₹1,670.62 | 1,500 ₹1,518.75 Lowest |
Tender Value
₹14.5 L
EMD Value
₹29,000
Closing Date
26 Nov 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Ludhiana
Garrison Engineer Military Engineer Services Near Jagraon Bridge Ludhiana-141001 (Punjab)
Widening of Entrance Gate in Technical area at Baddowal under GE Ludhiana.
2025_MES_734892_2
GE/LDH-64/2025-26
Open Tender
Civil Works
Item Rate
100 days
BADDOWAL
As per NIT and Tender documents
9 documents required · 9 mandatory
₹500
GE Ludhiana
₹29,000
Yes
19 Dec 2025
13 Nov 2025
28 Nov 2025
13 Nov 2025
26 Nov 2025
20 Nov 2025
13 Nov 2025 - 19 Nov 2025
Amount
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Demolition of cement concrete (unreinforced) in groung floors and pavings n.exc. 15 cm thickness (beow or above ground level) complete all as specified and directed.
Demolition of brickwork built in cement or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
Dismantling Asbestos cement corrugated sheet in roof covering complete all as specified and directed.
Excavating in post holes (or similar holes) in soft loose soil each n.exc 0.5 cum, getting out, returning, filling in and rammomg earth or broken rubble mixed with earth around, in layers not exc 25 cm, watering and removing surplus soil to adistance n. exc 50m and making good surface complete all as specified and directed.
M&L cement concrete 1:3:6 type C2 (using 40mm graded crushed stone aggregate) as in foundation filling of posts holes complete all as specified and directed.
Excavating over areas n .exc. 1.5m wide and n. exc 1.5 m depth for column footing complete all as specified and directed.
Excavating in trenches, n. exc. 1.5m wide and n.exc. 1.5m in depth for foundation, etc or for shafts well, cesspits, manhols, pier holes etc, n exc 10 sqm on plan and n.exc. 1.5m in depth and getting out complete all as specified and directed.
M&L for hardcore of broken stone boulders of gauge n.exc. 63mm, deposited, spread and levelled in layers n.exc. 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M & L for PCC subbase of 1:4:8 type D2 (40 mm graded crushed stone aggregates) complete all as specified and directed.
M&L for RCC1:2:4 type B1 (using 20 mm graded crushed stone aggregate) as in foundation, including rafts, footing, foundation beams; plinth beams bases for column etc footing complete all as specified and directed.
M&L for RCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) as in Column complete all as specified and directed.
M&L formwork to fair finished surfaces of concrete to sides of column footing complete all as specified and directed.
M&L formwork to fair finished surfaces of concrete to sides of column complete all as specified and directed.
S&F TMT bars 10 mm dia & over, cut to length bent to shape required including cranking, bending, spirally for hooking for column bending with not less than 0.9 mm dia complete all as specified and directed.
M&L TMT bars 5 mm dia, over & upto including 10 mm dia in stirrups, spacers & binders complete all as specified and directed.
M&L for 18 mm thick granite (of any type)tiles machine cut in skirting/dado laid over and including 10mm thick screed in CM 1:4 and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and granite polishing complete all as specified and directed.
M&L for PCC 1:2:4, type B1 (using 20 mm graded crushed stone aggregate) as in coping complete all as specified and directed.
Returning, filling, including, spreading, levelling, watering and well ramming in layers n. exc 25 cm thick, in soft/loose soil complete all as specified and directed.
Removing excavated material to a distance exc. 50m and n.exc. 250m and depositing where directed complete all as specified and directed.
S&F Mild steel framed work as in gate of angle & other sections with gusset plates, wheel track etc complete hooks for steel hanging door fittings also fastening and fixing complete in GDE i.e. 410 s complete all as specified and directed.
M&L for two coats of synthetic enamel paint over one coat of red oxide primer on newly steel surface over 10 cm in width or girth, complete all as specified and directed.
M&L for PCC 1:2:4 type B0 (using 12.5 mm graded crushed stone aggregate) as in hold fast of wheel track complete all as specified and as directed
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet as in ridge 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L Roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc conforming to Fe 290 (Gde E-165) quality A complete all as specified and directed.
M&L brick work with sub class 'B' bricks straight or curved on plan exc 6 mtr mean radius built in CM 1:6 complete all as specified and directed.
M&L rendering 10mm thick on brick work or concrete surface in cement mortar (1:6) and finished even and smooth without using extra cement complete all as specified & directed.
M&L rendering 15mm thick on brick work or concrete surface in cement mortar (1:4) and finished even and smooth without using extra cement complete all as specified & directed.
M&L PCC 1:2:4, 75mm thick type B-0 (using 12.5mm graded crushed stone aggregate) as in floors complete all as specified and directed.
M&L three coats of white wash on wall surfaces including prepration of newly plastered surfaces complete all as specified and directed.
M&L two coats of cement base paint in camouflage pattern on wall surfaces including preparation of newly plastered surfaces complete all as specified and directed.
Material and labour for sand cushioning with a layer of fine sand 8cm thick before laying of cable and 15cm thick after laying of cable in trenches complete all as specified and directed. Notes-:(i) Excavation and earth work to be measured and paid for separately. (ii)Thickness of 18cms after punning shall be considered for payment.
M&L Old size sub class ‘B’ bricks laid flat in trenches over the cable with the length of brick perpendicular to the direction of cable length, adjacent/abutting each other complete all as specified and directed.
Supply and laying XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 volts grade with stranded alumimium conductor of size 10 Sqmm 2 core including taking down the old unserviceable existing cable of same size complete all as specified and directed.
Supply and laying XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 volts grade with stranded alumimium conductor of size 16 Sqmm 4 core including taking down the old unserviceable existing cable of same size complete all as specified and directed.
Boring of holes under road, pavement, hard standing by trenchless technique and necessary T&P for passing of LT/HT cables complete all as specified and directed.
S&F in replacement GI tubing 50 mm bore 'light grade', galvanized, with all fittings jointed and laid in trenches/fix on wall floor for cable protection Including taking down of existing pipe complete all as specified and directed.
Supply and fixing for Submain wiring with PVC insulated cable copper conductor FRLSH two single core 4 Sqmm drawn through steel conduit including earth continuity FRLSH copper conductor 4 Sqmm PVC insulated with green insulation including taking down of old unserviceable existing submain wiring of same size with all accessories complete all as specified and directed.
M & L for DB's 4 way TPN double door with bus bar of 200 Amps rated pre fitted with MCB,and MCBs SP 6-32 Amps 10KA (as per site requirement) in outgoing circuits complete pre fitted and prewired with PVC insulated FRLS copper conductor wire of suitable size, with neutral bar and earth bar complete all as specified and directed.
M&L for sheet metal DB for MCBs, SPN, 4 ways, double door,singal phase, IP-43 company painted with 200 Amps rated bus bar, neutral bar/ connectors, each bar/ connectors, prewired complete with suitable copper conductor wire, PVC insulated, FRLS type with suitable copper thimbles, lugs etc complete all as specified and directed.
M&L for sheet metal DB for MCBs, SPN, 8 ways, double door,singal phase, IP-43 company painted with 200 Amps rated bus bar, neutral bar/ connectors, each bar/ connectors, prewired complete with suitable copper conductor wire, PVC insulated, FRLS type with suitable copper thimbles, lugs etc complete all as specified and directed.
M & L in replacement for TPN MCB, 415 Volts, 50 Hz, having rupturing capacity 10 KA,C Curve of rating 16 to 32 Amps complete all as specified and directed.
M & L for replacement TPN MCB, 415 Volts, 50 Hz, having rupturing capacity 10 KA, C Curve of rating 40 to 100Amps complete all as specified and directed.
M&L for replacement MCB SP 6 to 32 Amps, 10 KA, C-curve complete all as specified and directed.
M&L for replacement MCB SPN 32 Amps, 10 KA, C-curve complete all as specified and directed.
S&F in replacement LED flood light fitting of 150 watt in epoxy powder coated pressure die-cast aluminium housing with, BIS marked electronic driver duly enclosed of approved brand only in housing having protection against over voltage, short circuit and open circuit and surge protection against lightening of 5 KV minimum with IP-66, protection for LED and control gear compartments with high power LED chips suitable for voltage band 120 volts to 270 volt, power factor 0.95 (minimum) having Efficiency ≥ 120 LPW, 10KV SPD including taking down the old unserviceable light of same cap all as specified and directed.
Taking down and Shifting of existing LT panels of any size including all accessories complete all as specified and directed.
M& L for earthing complete with & including galvanized MS earth plate of size 600 x 600 x 6 mm thick, buried vertically in ground to a depth not less than 2.25 metre below ground level, with top edge of earth plate not less than 1.5 below ground level connected to galvanized earth wire soldered and riveted or connected to earth plate by means of nuts, bolts , check nuts & washers, of galvanized iron or steel all as Shown in electrical plate No. 3 of MES SSR Part- I (2009) and connected to panel board, all as specified and testing on completion including provn of earth wire 32x6 mm dia duly protected with and including 15 mm dia bore medium grade GI pipe upto 7.5 (maximum) meter from electrode to earth point including provn of the earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate and GI light grade watering pipe of 20mm dia bore with funnel with wire mesh including all necessary excavation & earth work in any type of soil, returning filling in, removal of surplus soil to a distance 50 metre, PCC 1:3:6 type C-1 as in earth chamber, 50 mm thick RCC cover using cementconcrete 1:2:4 type B-0 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work and MS frame using MS angle of size 40mm x 40mm x 6mm complete all as specified & directed. NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone by the contractor without any extra cost to the department.
M& L for earthing complete with & including galvanized MS earth plate of size 600 x 600 x 6 mm thick, buried vertically in ground to a depth not less than 2.25 metre below ground level, with top edge of earth plate not less than 1.5 below ground level connected to galvanized earth wire soldered and riveted or connected to earth plate by means of nuts, bolts , check nuts & washers, of galvanized iron or steel all as Shown in electrical plate No. 3 of MES SSR Part- I (2009) and connected to panel board, all as specified and testing on completion including provn of earth wire 4 mm dia duly protected with and including 15 mm dia bore medium grade GI pipe upto 7.5 (maximum) meter from electrode to earth point including provn of the earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate and GI light grade watering pipe of 20mm dia bore with funnel with wire mesh including all necessary excavation & earth work in any type of soil, returning filling in, removal of surplus soil to a distance 50 metre, PCC 1:3:6 type C-1 as in earth chamber, 50 mm thick RCC cover using cementconcrete 1:2:4 type B-0 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work and MS frame using MS angle of size 40mm x 40mm x 6mm complete all as specified & directed. NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone by the contractor without any extra cost to the department.
M/S Shyam kumar mehta and co (BID ID -3488716)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.16 MB
BOQ_828283.xls
BOQ • 4.62 MB
Tender64202526.pdf
Tender Documents • 0.95 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .