Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.0 LAccepted-AOC 705 SECTOR 23 127021 | BHIWANI | HARYANA | 127021 | L1 | Accepted-AOC LOA | |
| 2 | L2₹4.4 L+₹43,290 (11.0%)Rejected-Finance NH 148 B NEAR BABA GHISARAM FILLING STATION VILLAGE PALI MAHENDERGARH 123029 | MAHENDERGARH | MAHENDERGARH | HARYANA | 123029 | L2 | Rejected-Finance Highest | |
| 3 | L3₹4.5 L+₹57,900 (14.7%)Rejected-Finance | L3 | Rejected-Finance Highest | |
| 4 | L4₹4.6 L+₹62,000 (15.7%)Rejected-Finance | L4 | Rejected-Finance Highest | |
| 5 | L5₹4.6 L+₹68,000 (17.2%)Rejected-Finance SCO 68 FIRST FLOOR NEW GRAIN MARKET 134003 | AMBALA | AMBALA | HARYANA | 134003 | L5 | Rejected-Finance Highest |
| Sl No | Description | Qty | Unit | Su Solartech Systems Pvt Ltd L6 | vats solar private limited L1 | SUNGLOW ELECTRIC POWER PVT. LTD. L2 | envision Enterprises L4 | DEV POWER SYSTEMS L3 | dzire resources L5 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | [32.70.1]Supply Installation testing commissioning of Solar Photovoltaic grid connected roof top Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:-
(a) Solar Photovoltaic Module manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years.
(b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz plus /- 2.5 Hz, output voltage suitable to generate AC
(c) Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degrees C. The PCU shall adjust the voltage and frequency level to suit grid frequency
(d) Data Monitoring System complete with accessories.
(e) Fixing of Array junction box and Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required.
(f) Lightning and surge voltage protection.
(g) Connections and Interconnections by supplying and fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying and fixing of necessary channel/conduit lugs and other accessories etc. as required. 1. Above 1 kWp and up to 10 Kwp [Through Rate] | 10 | KWp | 48,210 ₹4,82,100 | 39,500 ₹3,95,000 Lowest | 43,829 ₹4,38,290 | 45,700 ₹4,57,000 | 45,290 ₹4,52,900 | 46,300 ₹4,63,000 |
Tender Value
₹4.9 L
EMD Value
₹9,740
Closing Date
2 Sept 2025, 5:00 pmClosed
NAVEEN RATHEE
ED - Ambala
Providing 10 Kwp Solar Power Plant of Sub Divisional Engineer Provincial Sub Division No-1, PWD BandR Br, Naraingarh District Ambala.
2025_HRY_467774_1
2025E42BBEDB 2202 438C A07E 36199DDAC2C3663BAR
Open Tender
Civil Works
Works
495 days
Ambala
Providing 10 Kwp Solar Power Plant of Sub Divisional Engineer Provincial Sub Division No-1, PWD BandR Br, Naraingarh District Ambala.
2 documents required · 2 mandatory
₹500
₹9,740
Yes
13 Oct 2025
26 Aug 2025
3 Sept 2025
27 Aug 2025
2 Sept 2025
27 Aug 2025
Amount
[32.70.1]Supply Installation testing commissioning of Solar Photovoltaic grid connected roof top Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- (a) Solar Photovoltaic Module manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. (b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz plus /- 2.5 Hz, output voltage suitable to generate AC (c) Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degrees C. The PCU shall adjust the voltage and frequency level to suit grid frequency (d) Data Monitoring System complete with accessories. (e) Fixing of Array junction box and Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. (f) Lightning and surge voltage protection. (g) Connections and Interconnections by supplying and fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying and fixing of necessary channel/conduit lugs and other accessories etc. as required. 1. Above 1 kWp and up to 10 Kwp [Through Rate]
SUNGLOW ELECTRIC POWER PVT. LTD. (BID ID -1326124)
DEV POWER SYSTEMS (BID ID -1328180)
envision Enterprises (BID ID -1325453)
dzire resources (BID ID -1326276)
Su Solartech Systems Pvt Ltd (BID ID -1327922)
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .