Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.0 LAccepted-AOC 72 546A ERATHARA H LIBERTY LANE KALOOR PO KOCHI 682 017 | KOCHI | ERNAKULAM | KERALA | 682017 | L1 | Accepted-AOC Admitted Found Reasonable for Acceptance | |
| 2 | L2₹6.6 L+₹40,795 (6.55%)Rejected-Finance KALIAPPA COMPLEX THRICHY ROAD RANGANATHAPURAM SULUR COIMBATORE 641 402 | COIMBATORE | COIMBATORE | TAMIL NADU | 641402 | L2 | Rejected-Finance Rejected L1 being accepted | |
| 3 | L3₹7.2 L+₹1.0 L (16.1%)Rejected-Finance HOUSE NO 105 PANTHEERMA VILLAI NEAR NELLIKKAVILLAI CSI CHURCH VELLAYAMBALAM VENCODE P O KANYAKUMARI DIST TAMIL NADU 629 171 | VENCODE | KANYAKUMARI | TAMIL NADU | 629171 | L3 | Rejected-Finance Rejected L1 being accepted | |
| 4 | L4₹8.3 L+₹2.1 L (33.2%)Rejected-Finance JJ BHAVAN TC 10 1378 2 GN 31 CHENCHERY ROAD NALACHIRA PO TRIVANDRUM 695 015 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695015 | L4 | Rejected-Finance Rejected L1 being accepted | |
| 5 | L5₹8.5 L+₹2.3 L (36.3%)Rejected-AOC A S NIVAS CHANKURTHY ADAIKKAKUZHI P O KANYAKUMARI DISTRICT TAMIL NADU 629153 | KANYAKUMARI | KANYAKUMARI | TAMIL NADU | 629153 | L5 | Rejected-AOC Rejected L1 being accepted |
Tender Value
₹11.2 L
EMD Value
₹22,460
Closing Date
17 Jun 2022, 6:00 pmClosed
GE Army Trivandrum
Office of Garrison Engineer Army, Thirumala Post, Trivandrum-06
As per tender documents
2022_MES_524692_1
GE (ARMY) TVM 9454/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Trivandrum
As per NIT
8 documents required · 8 mandatory
₹500
GE Army Trivandrum
₹22,460
Yes
23 Aug 2022
18 May 2022
24 Jun 2022
18 May 2022
17 Jun 2022
3 Jun 2022
Amount
Taking down carefully copper/aluminium point wiring for light, fan, bell, socket or power complete including fittings such as switches, ceiling roses pendents regulators, sockets and tube light fittings etc, removing materials from site or for reuse refixing and making good distrubed surface of wall, floors etc all as specified and directed.
Taking down main switches DBs with sheet metal enclosure 4/8 way SPN/TPN/DBs etc all as specified and directed.
Material and labour for point wiring complete with 1.5 sqmm PVC insulated unsheathed 1100 volts grade cable stranded copper conductor single core in casing caping of 20/25 mm complete with sunk iron pressed steel terminal box for fitting mounting switch/ sockets regulators etc with laminated sheet 3 mm thick cover and with 1.5 sqmm PVC insulated copper conductor earth wire and connected to earth dolly for one light point controlled by one switch all as specified and directed.
All as per item No 3 here-in-before but fan point controlled by one switch complete all as specified and directed.
All as per item No 3 here-in-before but Exhaust fan point controlled by one switch complete all as specified and directed.
All as per item No 3 here-in-before but for one 3 pin switch socket 5 Amp single pole one way on same board with other switches including continuous 1.5sqmm PVC insulated copper conductor earth wire to common wire earth and connecting to earth dolly complete all as specified and directed.
All as per item No 3 here-in-before but for 3 pin switch socket outlet 15 Amp independent with cable 4 sqmm unsheathed stranded 1100 Volts grade complete with 4 sqmm PVC insulated earth wire and connecting to earth dolly complete all as specified and directed.
All as per item No 3 here-in-before but for one 3 pin switch socket 5 Amp independent complete all as specified and directed.
All as per item No 3 here-in-before but for one bell point controlled by 5 Amps bell Push complete all as specified and directed.
Supply and fix switch piano type 6 Amp single pole one way complete all as specified and directed.
Supply and fix switch socket combination multi purpose 5 pin 5 Amp flush type complete all as specified and directed.
Supply and fix switch socket combination multipurpose 3 pin 16 Amp and 3 pin 6 amp flush type 2 in 1 complete all as specified and directed.
Supply and fix bell push 5 Amp flush type single pole 230 volts one way complete all as specified and directed.
Supply and fix in repairs switch piano flush type 5 amp single pole one way 230 V all as specified and directed.
Supply and fix in repairs switch piano type modular type 6 amp single pole one way 230 V all as specified and directed.
Supply and fix in repairs switch piano type modular type 16 amp single pole one way 230 V all as specified and directed.
Supply and fix in repairs bell push 5 Amp flush type single pole 230 volts one way complete all as specified and directed.
Supply and fix in repairs bell push 6 Amp modular type single pole 230 volts one way complete all as specified and directed.
Supply and fix in repairs switch socket combination multi purpose 5 pin 5 Amp flush type complete all as specified and directed.
Supply and fix in repairs socket outlet multi purpose 5 pin 6 Amp modular type complete all as specified and directed.
Supply and fix in repairs switch socket combination multipurpose 3 pin 16 Amp and 3 pin 6 amp flush type 2 in 1 complete all as specified and directed.
Supply and fix in repairs socket outlet multipurpose 3 pin 16 Amp and 3 pin 6 amp modular type 2 in 1 complete all as specified and directed.
Supply and fixing ceiling fan regulator rotary type 120 watts all as specified and directed.
Supply and fixing in repairs ceiling fan regulator rotary type 120 watts all as specified and directed.
Supply and fixing in repairs ceiling fan regulator modular type 120 watts all as specified and directed.
Supply and fix ceiling rose surface backelite three terminal complete all as specified and directed.
Supply and fix call bell AC, 230 Volts single pole all as specified and directed.
Supply and fix sheet metal enclosure powder painted for MCB DB SPN 8 way with din rail and bus bar including making good to the disturbed surface matching with the existing complete all as specified and directed.
All as per item No 28 here-in-before but 04 Way complete all as specified and directed.
Supply and fix MCB SP 240 Volts 6 to 32 Amps breaking capacity 10 KA rating complete all as specified and directed.
All as per ser item No. 30 here-in-before but for MCB single pole and neutral 32 Amps.
All as per ser item No. 30 here-in-before but for MCB single pole and neutral 40 to 63 Amps.
M&L for sub main wiring with 2 runs of 6 sqmm single core PVC insulated, FRLS, unsheathed cable with stranded copper conductor, 1100 Volts grade drawn through and including non metalic PVC conduit with all fitting such as Tee, Bends, Elbow, etc., fixed surface on wall/ceiling including 6 Sqmm multistranded PVC insulated, FRLS, copper conductor cable as earth continuity conductor and connecting to common earth dolly complete including dismantling of existing unserviceable submain wiring all as specified and directed.
All as per ser item No. 34 here-in-before but for sub main wiring with 2 run of 4 sqmm & 1 run of 4 sqmm as earth wire complete all as specified and directed.
Taking down carefully existing serviceable Ceiling fan/Wall mounted fan, ceiling cable end, etc., removing the fan for keeping in safe custody, hanging the ceiling fan with down rod, including clamps, hooks, holdfasteners etc and connecting up, including making electric connection from ceiling rose or connector to fan complete all as directed.
Taking down carefully existing serviceable exhaust fan, ceiling cable end, etc., removing the fan for keeping in safe custody, fixing the exhaust fan connecting up , including making electric connection from ceiling rose/connector to fan complete all as directed.
Supply anf Fix for LED lights fitting 1x 20W, 220V, AC decorative box type with driver, double sided connection, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Supply anf Fix LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Material and labour for eathing complete with galvanised steel earth plate electrode 600 x 600 x 6.3mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level coneected to galvanised earth lead wire of 4.0 mm by mean of bolts, nuts, check nuts and washer of galvanised iron steel all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including PCC pit and CI cover cover fullel with watering pipe, wire mess and copper lugs etc GI protection pipe of size 15mm dia including testing on completion complete all as specified and directed.
Supply and lay earth continuity conductor or main GI earthing lead fixed to wall ,on batten or recces or chasses or burried in ground or drawn in conduit /pipe or fixed to poles or any other indicated situation for loop earthing etc of 4mm dia galvanised iron or steel wire complete all as specified and directed.
Supply and fix in repairs single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and directed.
S&F in repair LED tube rod (double side connection) ultra bright glass LED tube of Cap 18W, 230V, with high efficacy for installation in existing fittings all as specified and directed.
Supply and fixing in repairs pin type (2 Pin) LED up to 10 W fittings all as specified and directed.
SUPER COOL
DJ GROUP
JEETH CONSTRUCTION
SUJAN
M/s VJ ENTERPRISES
S L ELECTRICAL WORKS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .