Lt Col Suraj Sadasivan
Military Engineer Service Garrison Engineer (AF) No.1 Air Force Station No 1 Jamnagar 361003
REPAIR MAINT OF FIRE ALARM SYSTEM WITH ALLIED WORK OF TECHNICAL AREA UNDER GE (AF) JAMNAGAR NO. 1
2026_MES_788905_1
8449/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
JAMNAGAR
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (AF) Jamnagar No 1
₹30,000
Yes
11 Sept 2026
11 Sept 2026
28 Sept 2026
11 Sept 2026
26 Sept 2026
21 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Material & Labour in repair for sub main wiring with 2 run single core multistranded copper conductor cable of size 2.5 Sqmm, PVC insulated, unsheathed, FR-LSH (Flame Retardant Low Smoke & Halogen), drawn through and including mild steel ERW conduit not less than 20mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 2.5 Sqmm, PVC insulated, unsheathed, FR-LSH as earth wire, fixed on wall / ceiling, complete all as specified and directed by Engineer-in-Charge.
Note: 2 Runs of main cable and one run earth wire with conduit will be measured as one Unit for payment. | 200 | RM | - | - |
| 2 | Material & Labour for Checking, inspecting and finding of faults in looping, siren, wiring, panel working of existing fire alarm system from OEM engineers and rectification of defects. Control electrical wiring connected to fire alarm sytem including programming of panel/module smoke detector etc., complete all as specified and directed by Engineer-in-Charge.
Notes (a)-Any spare part required for reparing / replacement shall be measured separatly under respective items.however minor spare part of repair work are deemed to be included in quated rate.
(b) Checking of fire alarm system at site on each control panel shall be measured one job for payment. | 4 | Each Job | - | - |
| 3 | Material & Labour for checking/testing of fire alarms system complete including checking of all connection, between each module upto panel, complete all as specified and directed by Engineer-in-Charge.
Note:- (i) Cost of replacement of any module i.e smoke detector, MCB, Siren to be paid under relevant items.
(ii) Testing should be done in 03 Places/points of each location or as directed by Engr-in-charge)
(iii) Checking of fire alarm system at site on each control panel shall be measured one job for payment. | 42 | Each Job | - | - |
| 4 | Material & Labour for servicing, cleaning of smoke detector of any type (Addressable/ conventional), and refixing the same, complete all as specified and directed by Engineer-in-Charge.
Note:- Cost of necessary T&P like ladder required at site are deemed to be included in the quoted rate | 500 | Each | - | - |
| 5 | Supply, installation, commissioning and testing in repair of Analogue Addressable Fire Alarm Control Panel including detector wise configuration facility 2000 Event storage with Real Time Clock, upto 192 grouping facility, Pre Alarm Action, Programmable Detector sensivity. Device type verification, Earth fault annunciation facility at 0 ohms, Double Address Sensing, Loop wise device test, 40 x 4 characters LCD display 4 numbers of loop card and 254 devices in any combination per loop. Day / Night mode facility. USB 2.0 interface for PC connectivity. Rs. 485 Communication facility for Network / Repeater / MODBUS / BACnet. Programmable Auto Silence Facility. Programmable AC Loos Delay. Programmable Silence Inhibit. Two No’s of programmable inputs. Battery low audio, visual warning. Three programmable Form C relay for Fire, Fault and Supervisory. Primary Power 120 / 220 VAC+10% - 15%, 60/50 Hz. Standby Power 24V DC (2Nos. of 12V 40Ah Max, built in for 12Ah) Sealed Lead acid battery operation condition operation temperature 0 - 49º C / 32 - 120º F Relative Humidity 93 ± 2% RH (Non-condensing) at 32 ± 2º C /90 ± 3º F and including taking down old unserviceable panel nd fixing at existing location complete as below:-
Make:- Raval, Model:- Avani | 2 | Each | - | - |
| 6 | Supply, installation, commissioning and testing in repair of Analogue Addressable Fire Alarm Control Panel including detector wise configuration facility, Total no of device capacity 198, Sensor capacity 99, MCP, Modules capacity 99, loop capacity 500mA per loop, 6x40 character blue liquid display with back light illumination, 2 independent programmable function keys and LED indication, network upto 16 loop capacity, disable all relay, easy 5 key- press set up, alpha numeric style keypad, upto 72 hour standby, 160 fire zones, 7 day timer, coincidence and verification detection for false alarm management, 2 independent sounder circuits, 500mA MIAS protocol loop driver. Operation voltage- 110 / 230 VAC+/-15%. PSU rating 24VDC 2A stand by batteries -2x7AH, stand by batteries duration 24 hours, Auxiliary output-24VDC 250mA fused including taking down old unserviceable panel fixing at existing location complete. Make: - Honeywell, Model: - Morley IAS | 1 | Each | - | - |
| 7 | Supply, installation, commissioning and testing in repair of Analogue Addressable Fire Alarm Control Panel including detector wise configuration facility, up to 159 detector and 159 modules per SLC, 318 device maximum, standard 80 character display, high speed network up to 200 nodes, 6A power supply with four class A/B built –in notification appliance circuit(NAC), selectable system sensor, Wheelock or gentex strobe synchronization, built in alarm, trouble, security and supervision relays, auto programming and walk test reports, multiple central station communication option, history file with 800- event capacity in nonvolatile memory, plus separate 200 event alarm only file, alarm verification selection per point with automatic counter, battery charger support 18-200Ah batteries including taking down old unserviceable panel fixing at existing location complete.
Make: - Honeywell, Model: - Notifier | 1 | Each | - | - |
| 8 | Supply, installation, commissioning and testing in repair of 2 Zone Conventional Gas Realease Panel complying with BS EN 54 Single loop panel of capacity from 99 detectors & 99 modules upto 200 detector including taking out old unserviceble panel and fixing at existing location complete all as specified as directed by Engineer in Charge.
Make: Ravel Electronics Pvt Ltd. / Honey Well / Ceasefire Industries Pvt. Ltd | 1 | Each | - | - |
| 9 | Supply, installation, testing and commissioning Conventional Fire alarm control panel complying with BS EN 54 Single loop panel of capacity from 20 detectors & 20 modules, complete all as specified and directed by Engineer-in-Charge.
Make: Ravel/HONEYWELL/CEASEFIRE INDUSTRIES PVT LTD | 4 | Each | - | - |
| 10 | Supply, installation and commissioning and testing of loop Card in repair having 254 devices of both detectors and modules in a single line circuit, SLC supports both class A and class B wiring or equivelent and including taking down old unserviceable, complete all as specified and directed by Engineer-in-Charge.
Make: Ravel/HONEYWELL/CEASEFIRE INDUSTRIES PVT LTD | 8 | Nos | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.40 MB
PS.pdf
Tender Documents • 0.91 MB
BOQ_884301.xls
BOQ • 0.83 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .