Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹30.8 LAdmitted-Finance 130 2 RAM BAGH UPPER HARIPUR SUNDER NAGAR DISTRICT MANDI H P 175018 | MANDI | HIMACHAL PRADESH | 175018 | L1 | Admitted-Finance | ||
| 2 | L2₹31.3 L+₹52,394.22 (1.70%)Admitted-Finance MANDI DISTT MANDI HP | MANDI | HIMACHAL PRADESH | 175001 | L2 | Admitted-Finance |
Tender Value
₹29.1 L
EMD Value
₹58,250
Closing Date
22 Mar 2026, 10:00 amClosed
EE Electrical Division HPPWD Mandi
EE Electrical Division HPPWD Mandi
SH- Providing extension of existing Bus DUCT
2026_PWD_131415_1
No.PW-MED-TA-Tender/2025- 7544-58 Dated- 26.02.2026
Open Tender
Electrical Works
Percentage
120 days
Nerchowk, Distt- Mandi
As per SBD
14 documents required · 14 mandatory
₹2,000
₹58,250
16 Apr 2026
16 Mar 2026
23 Mar 2026
17 Mar 2026
22 Mar 2026
17 Mar 2026
SITC of folowing capacity IK 10 Sandwitch Type Bus Duct confirming to IEC 61439 part 1 and part 6 standard and manufactured in india for use on 3 phase 4 wire , 415 volts, 50 Hz Ac Supply , class F Multilayer Polyethylene Terephthalate (UL Listed) insulation ( without MICA) , rated insulation voltage 1000 V , seismic zone 5 as paer IS 1893 (Part 1 ) with IP 54 enclosure made of 1.6 mm thick sheet duly powdered coated in convenient section complete with 4 Nos aluminium ( with IS 19501 or superior) bus bars , necessary joints and expansion joints , continuous earthing aluminium strip of suitable size including and prefabricated OEM provision for bolting arrangement of the earthing strip . All adopter box sheet shall be of 2 mm thickness . Type tests reports like 1) short circuit test 2) degree of protection 3) Temperature rise test of Rising main in CPRI /UL/ ASTA accredited lab will be submitted by OEM . complete with Fange Ends, Bends, Adaptor Box and all neccessry arrangem,ents : 415 V Sandwitch construction Busbar Trunking system wiyj Multilayer class F insulation Make : Schneider (C&S) , L &K , Siemens
2000A straight -IP54, 65KA
2000A Flange end(fabrication Cost Only)
2000A Vertical/Horizontal Bend (fabrication Cost Only)
2000A Flange end+ Adopter box
2000A Tinned Copper Braided flexibles
Adopter Box at Panel end
Aluminum erthing Strip-50x6 (with hardware-Nots and Bolts)
Conditions:-
The work shall be carried out according to CPWD/HPPWD General Specifications.
The work shall be completed to the entire satisfaction of the Engineer-in-charge.
The firm will have to follow fair wage clause.
Sub-standard work will not be accepted.
No claim on account of fluctuation in prices due to any reason shall be considered.
The quantity can be increased or decreased as per actual requirement at site.
The conditional tenders shall not be accepted.
No premium will be allowed on M.R. Items, abatement, if any shall be applicable on all items
The contractor has to employ qualified Engineer for the supervision of work at site.
Any error or omission in nomenclature or unit can be corrected at any stage.
The quality of material shall be strictly in accordance with the specification given in DNIT.
All the material shall be inspected by the Engineer-in-charge of work before installation at site.
All the cable/ wire connections should be done through lugs / thimbles duly crimped with proper crimping tools & no extra payment shall be made on this account.
The department has reserve the right to issue any amendment to the work order as emergency demands or allow of altogether cancel the contract without assigning any reason. The department reserves the right to delete / add any item.
Discount offered by the firm should also be considered in deviation of items.
The extra/substitute items will not be allowed against this work.
Security shall be deducted on each running/ Final bill of the firm without prior approval of competent authority as per CPWD/HPPWD works manual.
The firm shall be quote the rates inclusive all the taxes/ GST whatever required and no extra payment shall be made in this respect.
The fittings/ material shall be inspected by the concerned Engineer in charge with the representative of the firm and necessary certificate shall be signed by the representative of the firm for its genuineness.
Any deviations to the clauses in the tender specifications must be clearly and separately indicated otherwise it shall be presumed that the offer is in line with requirements of tender.
The proposed system should be fully integrable with existing system i.e E Square Panel system.
stage.html
html • 0.03 MB
technical_194276.pdf
techsummary_194276.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.28 MB
BOQ_194276.xls
BOQ • 0.31 MB
SBD_Nerchowk.pdf
Tender Documents • 4.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .