Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.9 CrAccepted-AOC | ₹11.9 Cr Quoted ₹12.4 Cr | L1 | Accepted-AOC LOWEST |
Tender Value
₹10.8 Cr
EMD Value
₹5 L
Closing Date
30 Oct 2023, 11:00 amClosed
SUPERINTENDING ENGINEER
OFFICE OF THE SUPERINTENDING ENGINEER,KWA,PH CIRCLE, THANA, KANNUR
JAL JEEVAN MISSION -KASARAGOD DISTRICT -KINANOOR KARINTHALAM PANCHAYATH - CONSTRUCTION OF INTAKE WELL CUM PUMP HOUSE, SUBSTATION BUILDING, RETAINING WALL AND RAW WATER PUMPING MAIN
2023_KWA_597814_1
116/2023-24/PHC/KNR(RE-TENDER)
Open Tender
Civil Works - Water Works
300 days
KINANOOR KARINTHALAM
Please refer Tender documents.
11 documents required · 11 mandatory
₹19,518
₹5 L
KWA,PH CIRCLE, THANA, KANNUR
8 Feb 2024
22 Aug 2023
31 Oct 2023
22 Aug 2023
30 Oct 2023
23 Aug 2023
23 Aug 2023
Amount
Appendix A:part I-Construction of Intake Well and pumphouse at Andol
2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
OD99280/2023-2024:Providing Z steel sheet pile of size 400x185x7.5/8.5 driving down vertically in lines and levels interlocking with adjacent piles with suitable piledriving unit and all accessories including all labour hire charges etc. complete and as per the directions of departmental officers at site.
2.7.1:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock
2.26.1:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil
100.4.9:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 6.0m (4.5m to 6.0m) but excluding bailing out water and including providing protection by earth filled cement bags (300 Nos. of earth filled cement bags / 10 m3 blasting) to avoid damages to the nearby structures)
100.4.S.6:15% extra for additional lift excluding cost of materials.
OD99287/2023-2024:Providing 20mm tor steel dowel rods at bottom of the well at 30cm in two rows for fixing the curb with bottom hard rock layer including cost of materils, labour charges etc. complete
100.7.1:Bailing out water with 5HP engine and pump set including conveyance to the site, erecting, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc., complete.
100.7.2:Bailing out water with engine and pump set above 5HP up to 10HP including conveyance to the site, erecting, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc., complete.
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
50.5.7:Reinforced cement concrete work in well-staining excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1. 5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
50.5.33.2:Providing and laying in position machine batched and machine mixed design mix M-20 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. Note:- Cement content considered in this item is @ 330 kg/cum. Excess or less cement used as per design mix is payable or recoverable separately. All work above plinth level upto floor V level
5.9.12:Centering and shuttering including strutting, etc. and removal of form for:Well steining
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.16.1:Centering and shuttering including strutting, etc. and removal of form for: Edges of slabs and breaks in floors and wallsUnder 20 cm wide
5.9.8:Centering and shuttering including strutting, etc. and removal of form for:Sprial staircases (including landing)
OD99420/2023-2024:Construction of granular sub-base by providing graded material, spreading in uniform layers with a motor grader on a prepared surface, mixing by mix in-place method with rotavator at OMC, and compacting with a vibratory roller to achieve the desired density, complete as per clause 401. Grading-V - For sub-base cum drainage layer - Mix in Place Method
4.1.2:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:1/2:3 (cement : 11/2 coarse sand : 3 graded stone aggregate 20 mm nominal size)
5.11.1:Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
50.6.7.2:Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc.
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
OD99430/2023-2024:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) using department stone ( excluding cost and conveyance of stone)
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
50.13.1:9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete
13.7.2:12 mm cement plaster finished with a floating coat of neat cement of mix:1:4 ( 1 cement : 4 fine sand)
10.25.2:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
21.1.1.2:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
21.3.1:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness
10.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover
13.85.1:Applying priming coats with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content.With ready mixed pink or grey primer on wood work (hard and soft wood ) having VOC content less than 50 grams/ litre
11.37:Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.
11.41.2:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
10.26.1:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.M.S. tube
OD99528/2023-2024:Supply, fabrication and erection of long travel (LT) girder fixing to the base plate at the existing bracket at site including cutting hoisting and fixing in position and painting the exposed surface with a coats of steel primer and 2 coats of aluminum paint including cost of labour charges and conveyance of all materials, etc. complete and as directed by the departmental officers for 10cm internal diameter intake well cum pump house
OD99530/2023-2024:Design manufacture supply of 5T capacity electrically operated over head crane arrangements suitably positioned on appropriate ISMB steel sections used as main girders, carbon steel for circulating railing and grooved wheels. The entire assembly shall be capable for three dimensional lifting operations covering the entire pump house area. The whole mechanism must be easily operated from the pump house floor and all the rotating parts shall be fitted with suitable bearings of international quality. The collinear transmission shall incorporated if any shall be jointed with steering cross and rivets. The gear box and transmission arrangements of the crane must be designed for smooth and easier operations. The motors and other electrical fitting connected with the crane shall be comply to relevant Indian Standards. All necessary safety arrangements shall be incorporated in the crane arrangements such as stoppers, overhead protection, earthling etc. The entire installations shall be painted using aluminum paint after two priming coat. An operation manual of the same also be supplied. The trolley frame shall be steel box sections and axial bearing shall be superior roller type. Wheel assembly should be fitted in L type housing and trolley wheel shall be medium carbon alloy steel solid forged with BHN 341. All gear boxes shall be completely enclosed having splash lubricated type scaled with neoprene O ring
OD99543/2023-2024:Erection and commissioning of the above specified 5T capacity electrically operated over head crane arrangements suitably positioned on the appropriate ISMB steel sections including providing and fixing suitable side 45 x 45 MS base plate 18mm thick over the existing RCC pillars brackets by drilling, fixing belt of suitable size and grouting with CM and welding LT girder ISMB 550 with cover plate 20mm thick and circular girder ISMB 250 with required MS base plate if any and also fixing the ends of the LT girder to the size suitably and also providing LT rail with suitable end stoppage. This also includes provision for box type fabricated from rolled steel section and carriages of suitable construction with all good quality accessories like gears, wheels axis rubber buffers, bearing etc, the work also consists of all tools and equipment's , labour, supervision, load testing all safety devices required for the satisfactorily operation etc.. The rate inclusive of MS base plate, stoppers and carriage, all required accessories, painting with aluminum paints including trial run etc. complete
17.7.7:Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 450x300 mm with single 15 mm C.P. brass pillar tap
50.9.1.1:Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood
50.9.4.1:Providing and fixing paneling or paneling and glazing in paneled or paneled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured) paneling for paneled or paneled and glazed shutters 25 mm to 40 mm thick using good quality Anjili/ Jack wood
13.48.2:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.75 ltr/10 sqm of approved brand and manufacture
OD126750/2023-2024:Structural design & Detailing of Intake well including soil investigation
Appendix -B- part II - 350 mm RWPM, - cost of materials
100.98.120:Supply of DI K9 Pipe Conforming to IS 8329/2000, 350mm Dia.
OD108790/2023-2024: Supply of CI Non Return Valve, Conforming to IS 5312 Part I - 1984, PN 1.0, Size 350mm.
100.98.464:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 350mm.
100.98.463:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 300mm.
100.98.461:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 200mm.
100.98.457:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 80mm.
100.98.454:Supply of CI Air Valve with Flanges, Conforming to IS 14845 - 2000, Kinetic Air Valve Type DS2, Size 80mm.
Appendix - C- Part 1- 350mm RWPM -working charges
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.1.5:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50 m, in Ordinary Rock.
100.2.3:Excavating trenches of required width for pipes, cables, etc.. including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in Medium Rock Requiring Blasting.
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.
100.8.2:Fencing 1.50m high with two rows of casuarina poles (girth 15cm to 24cm) tied with coir yarn on vertical casuarina pole (girth 15cm to 24cm) fixed at 1.5m intervals.
100.41.40:Supply, stacking, spreading and consolidating of Red earth in the trench of pipe line for cushion including carriage, loading, unloading & stacking up to any lead.
OD108814/2023-2024:Labour for cutting D.I. pipe with steel saw.<br>350 mm diameter D.I pipe
18.30.8:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:350 mm diameter pipe
18.70.6:Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:350 mm dia pipes
100.14.6:Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials: 350mm diameter Ductile Iron Class K-9 Pipes.
100.35.6:Testing 350mm DI/CI pipeline with potable water to the required test pressure. 350 mm dia Observed Data derived from item no.1024 of PHED DATA
100.32.4:Conveying and fixing C. I. Double Acting Air Valve of approved quality with bolts, nuts, rubber insertions etc., complete, but excluding the cost of air valve (tail pieces, if required, will be paid separately): 80mm Double Acting Air Valve.
100.31.1.1:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 80mm diameter, Class I.
100.31.1.5:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 200mm diameter, Class I.
100.31.1.7:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 300mm diameter, Class I.
100.31.1.8:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 350mm diameter, Class I.
100.37.10.2:Fabricating M.S. flanges of diameter 350mm using 12mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.10.3:Cutting 350mm (I.D.) M.S. pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.10.4:Welding 350mm (I.D.) M.S. pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.10.5:Grinding cut and weld edges of 350mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.9.1:In situ fabrication of M.S. pipes of size 300mm (I.D.) using 8mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete.
100.37.9.2:Fabricating M.S. flanges of diameter 300mm using 12mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.9.3:Cutting 300mm (I.D.) M.S. pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.9.4:Welding 300mm (I.D.) M.S. pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.9.5:Grinding cut and weld edges of 300mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
OD267008/2022-2023:Conveying and laying MS Pipes excluding cost of pipes and specials: 300mm diameter MS Pipes.
100.37.14.1:In situ fabrication of M.S. pipes of size 600mm (I.D.) using 8mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete.
100.37.14.4:Welding 600mm (I.D.) M.S. pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.14.5:Grinding cut and weld edges of 600mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
OD274733/2022-2023:Conveying and laying MS pipe<br>600 mm dia <br>Data derived from 100.14.10
18.69.1:Providing and laying D.I Specials of Class K - 12 suitable for mechanical jointing as per IS : 9523 :Upto 600 mm dia
18.68.1:Providing and laying D.I specials of class K - 12 suitable for push - on jointing as per IS : 9523 :Upt 600 mm dia
100.37.7.1:In situ fabrication of M.S. pipes of size 200mm (I.D.) using 8mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete.
100.37.7.2:Fabricating M.S. flanges of diameter 200mm using 12mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.7.3:Cutting 200mm (I.D.) M.S. pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.7.4:Welding 200mm (I.D.) M.S. pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.7.5:Grinding cut and weld edges of 200mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
OD267007/2022-2023:Conveying and laying MS Pipes conforming to excluding cost of pipes and specials: 200mm diameter MS Pipes.
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
100.41.33:Supplying and fixing 500mm dia C.I. manhole cover with frame (medium duty) charges including all cost, labour charges etc., complete.
OD274740/2022-2023:providing push through arrangement for BM and BC road for 600 mm casing Pipe
OD274744/2022-2023:Supplying and fixing Electromagnetic flow meter conforming to protection level IP-68 for flow sensor and IP-67 for transmitter and having an accuracy level of 0.5% with LED/LCD display unit suitable to measure the discharge of CW . The flow meter should have the housing ( flow sensor) to be made of SS 304/Carbon steel with anti-corrosive protection and inside liner to be made up of Hard Rubber/ Neoprene all confirming to drinking water standards. The flow meter should be coupled with HART for data acquisition and transfer with provision for wireless transfer through GSM. The manufacturers should have the calibration standards as per ISO 17025 and the product shall have sufficient warrantee position. Flow meter should be tested and calibrated at FCRI, Palakkad and test certificate should be produced. Flow meter should be calibrated with physical measurement at site after installation. A battery back of min 24 hrs should be provided. For 300 mm Flow meter<br><br>
100.37.10.1:In situ fabrication of M.S. pipes of size 350mm (I.D.) using 8mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete.
Appendix - D - Supply, erection, commissioning and maintaining of vertical turbine pump sets
OD266958/2022-2023:Supply, erection, testing and commissioning of KWA pre-qualified reputed make vertical turbine type pump set with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling guard foundation bolts & nuts, non reversible ratchet mechanism etc. complete suitable for coupling the pump and motor above the base plate etc. complete including providing suitable concrete foundation including cost of cement, saand and metal etc. complete including supply, rection,, testing and commissioning of KWA approved suitable fype soft starters, panel board(suitable for operating three pump sets but two pump set at a time), cabling work, earthing, capacitors, valves and suction and delivery pip0e connections etc. complete including two year maintenance cost of all the components related to pump sets<br><br>Duty conditions:<br>Discharge - 81 lps<br>Total head - 137.4m<br>Minimum efficiency - 70 % when working as single pump set and when working parallel with another pump set <br>with 5% extended warranty (Total three year warranty)
OD266959/2022-2023:Soft starters, supplying a complete integrated soft starter panel capable of operating the motor having protection level of IP 40 or more with integrated by pass contractor in the panel and motor protection relay having parameters as per IE rules with a power control MCCB and line power contractor and the starting current shall be 2.5-305 times the normal full load current of motor with ammeter, volt meter, and phase indicators, space heaters, floor mounting type and having an insulation level of 1100 V( for 440V supply) and 706 KV fpr (303 Kv supply) and 14.2 KV(for 606 KV supply) (Total three year warranty)
OD99076/2023-2024:Supply and erection of TEFC Squirrel cage induction motor with capacity to run above pumpset with maximum efficiency (Total three year warranty)
OD122704/2023-2024:Design, supply, erection and commissioning of APFC capacitor panel having suitable capacity and voltage for power factor compensation for motors to achieve a power factor 0.98 or higher at any combination of running of pump sets and shall be fitted with digital APFC controller of reputed make with 3phase current and voltage measurement, pf display(3 digit after decimal), individual harmonics measurement, front panel setting keys for power factor and other settings . The capacitor should confirm to IS 2834-1986. 3300 volts / 433 volts as the case may be. The switching of capacitor shall be with capacitor duty VCB for 3.3 KV and capacitor duty power contactor for 433 Volts. The panel shall have indication for capacitors in service and instantaneous power factor value. (For 100 HP CF pump set at WTP pump house ( 2 nos running at a time)
Appendix-E- Construction Of Retaining Wall
2.1.1:Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m and lift up to 1.5 m, disposed soil to be levelled and neatly dressed:All Kinds of soil
2.7.1:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock
2.7.2:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Hard rock (requiring blasting)
2.7.3:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Hard rock (blasting prohibited)
100.7.1:Bailing out water with 5HP engine and pump set including conveyance to the site, erecting, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc., complete.
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
5.37.1:Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in -charge. Note:- Cement content considered in this item is @330 kg/cum. Excess /less cement used as per design mix is payable/recoverable separately.All wiork upto plinth level
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
50.13.1:9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete
Appendix-F-Transformer
OD108939/2023-2024:Supply of all materials and providing 11KV sub station yard using 4nos. 175x85mm. ISMB joist of 9.5M height, 100x50mm. MS chanel cross arms, 2sets of 200A, 11KV gang operated AB switches with opertating handles of required length,2 sets of 9.6KV,6KA , Lightning Arrestors, 2sets of 11KV, D.O fuses, Pin insulators, Disc insulators and inter connections of the above items using 8mm dia copper wire with proper copper sockets , including all associated civil works and painting of all structurers with two coats of zinchromate primer and aluminium paint etc. complete as per standard construction practices approved by Kerala Electrical Inspectorate and relevant standards
OD108943/2023-2024:Supply of all materials and providing substation yard fencing using 50 x 50 x 6mm angle iron frame work of size 1500x2500mm fitted with weld mesh of 10 gauge and bolted the same to 100 x 50 x 6 mm vertical chanel erected at 1500mm c/c and 2500mm above ground level of substation yard and 500 mm below with 300 x300mm plain cement concrete (1:3:6) base using 40 mm granite aggregate and top surface finished neat and including all associated civil works andpainting of all structures with two coats Zinchromate primer and aluminum paint etc. complete as per standard construction practices approved by Kerala Electrical Inspectorate and relevant standards and.including spreading of 40mm broben stone over a lyer of river sand/Msand as per IS specifications
OD108956/2023-2024:Supply of all materials and providing 2000mm wide 2500mm height weld mesh gate made out of 50 x 50 x 6mm Angles with necessary foundation locking arrangements etc. complete, including painting with two coats of zinchromate primer and aluminium paint as per standards
OD108969/2023-2024:11KV Metering Unit-Supply,erection, testing and commissioning of out door type metering unit consisting of the following accessories:Current Transformer ,CT Ratio 70/5A,Burden 15VA,Accuracy Class 0.5,Potential Transformer,PT ratio 11KV/110V,Burden - 100VA.,Accuracy Class 0.5,The rate shall include the cost of testing the equipment at KSEB and all other incidental expences. The CT ratio should be fixed only after obtaining the power allocation from KSEB..
OD108974/2023-2024:TOD Meter-Supply,erection, testing and commissioning of TOD meter with maximum demand in KVA suitable for the above out dKooer rmaeltearinWg saettehorusAeduinthaowreiattyher proof out door Kiosk.The rate shall include the cost of testing the equipment at KSEB and all other incidental expenses
OD108983/2023-2024:Design, Supply, erection, testing and commissioning of 11KV, 400A, 350MVA, totally enclosed, single bus bar, floor mounting in metal clad, indoor extensible type flush mounted horizontal isolation and drawout type vacuum circuit breaker single panel system (1 no. VCB ) suitable for installation in 3 phase , 3wire, 50Hz. AC,11kv, effectively earthed supply system,comprising of motorised and spring assisted, independent, trip free closing mechanism and 11kV PT, CT, all metering equipments( A, V, KW, PF), Microprocessor based digital transformer protection relays of reputed make etc. complete as approved by Kerala Electrical Inspectorate and relevant standards. Armoured multi core 2.5 Sqmm copper control cables shall be used for all external &amp; internal interconnections. The cost of control cables both internal and external shall be included in the cost of HT panel
OD108987/2023-2024:11KV/433 V,315 KVA Transformers (oudoor type).-Design, Supply, erection, testing and commissioning of 315 KVA, 11KV/433V 3phase, 50Hz. ONAN cooled , outdoor type copper wound distribution transformers with HV and LV side cable entry box , on load tap changer with 17tap positions having 5% to -15% variations in1.25 % steps with RTCC panel including first filling of oil etc. complete with all fittings as per IS 2026 and Kerala Electrical Inspectorate standards. Armored 2.5 Sq mm copper control cable shall be used for all external interconnections. The cost of control cables both internal and external shall be included in the cost of Transformer. Including supply , erection, testing and commissioning of suitable capacity neutral CT with weather proof enclosure.
OD109005/2023-2024:Lighting Distribution board (LDB)-Supply,erection, testing and commissioning of MCB distribution board comprising to the following. 40A TPN 4 pole MCB 1 No. as incomer with 40A 30mA ELCB, 18 nos 6 AMPS SP MCB as outgoings, &lt;br&gt; With tinned copper busbars/cables, interconnection, housed in a suitable metal enclosure as per KEI standards fixed in open system
OD109014/2023-2024:Cabling-Supply, laying, testing and commissioning of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable (1100 volts&amp;3.3/11kv grade) clamped on wall/ceiling with clamps and saddle clips partly laid in cable tray/partly laid in trench. 3core 300sqmm 11kv XLPE Al cable
OD109021/2023-2024:Supply,Laying,Testing and Commissioning of following sizes of MV(1100V) cables XLPE Aluminum cables as per IS.standards 3.5x300 Sq. mm ( transformer to MSB, MSB to Pump control panel)
OD109026/2023-2024:Supply,Laying,Testing and Commissioning of following sizes of MV(1100V) cables XLPE Aluminum cables as per IS.standards 3.5x50Sq. mm ( MSB to LSB)
OD109037/2023-2024:Supply of all materials and providing cable end terminations of the following size of PVC/XLPE insulated, sheathed 3core 300sqmm 11KV XLPE armored AL UG cable( indoor and out door)
OD109041/2023-2024:supply of all materials and providing end terminations 3.5 core 300Sq.mm. 1100V AYFY Cable using double compression brass cable gland
OD109046/2023-2024:supply of all materials and providing end terminations 3.5 core 50Sq.mm. 1100V AYFY Cable using double compression brass cable gland
OD109050/2023-2024:Supply of all material providing earthing using 600mm x 600mm x6mm size copper earth plate buried in ground at a depth of 3.0m from ground level with alternate layers of charcoal and common salt including supply and fixing of 38mm dia c class GI pipe, funnel for watering purpose, copper strips interconnection including construction of masonry chamber with MS cover as per IS 3043-1987. conductivity enhancing compounds shall be used as needed to obtain the required earth resistance value
OD109055/2023-2024:Design, Supply, laying and termination of the various sizes of copper strip/wires for earthing of substation, transformers, HTpanel boards,LT panel boards, equipments and inter connection of earth pits etc complete as per standards and as approved by the Electrical Inspector
OD109064/2023-2024:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable size GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
OD109073/2023-2024:Wiring to the 5 Amps plug points with 3/22 PVC insulated copper conductor along with single run 3/22 PVC insulated copper conductor ( Green colour ) drawn inside suitable size PVC conduit pipe with necessary bends, elbows, junction boxes etc. in open conduit system clamped on struss/wall with suitable clamps and saddle clips including supplying and fixing of 5 Amps flush type 3 pin plug control
OD109081/2023-2024:Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required. 1200mm 2x20w box type LED tube fittings
OD109083/2023-2024:Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required. 1200mm 1x20w box type LED tube fittings
OD109095/2023-2024:Supply, fixing of bulkhead light fitting with 60W lamp
OD109104/2023-2024:Supplying and fixing of 1200mm sweep AC ceiling fan with standard down rod and electronic type regulator
OD109107/2023-2024:Supplying and fixing of 12&amp;rdquo; dia single phase 1500 RPM exhaust fan with necessary MS frame work.
OD109116/2023-2024:External Lighting.-Supplying, erection and testing steel tabular swaged poles as per IS 2713(Part II)- 1980 of height 7.5M above ground level and 1.5M below ground level bottom 139.7mm dia and 114.3mm dia for middle and 88.9mm dia for top including providing base plate providing concreting in foundation. construction of pillar accommodating fuse and switch housed in weather proof box including wiring to the light fitting with 2 runs of 3/20 PVC insulated copper conductor. Supplying and fixing a 4 way 30A rated terminal block include the weather proof box. The pole shall be painted with one coat of primer and two coats of enamel paint as required by the Engineer in charge. The street pole shall be as per the drawing enclosed.Single bracket type,Double bracket type.
OD109117/2023-2024:70W LED steet light output &gt; 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor &gt;0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD &lt;10%, power factor &gt;0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&amp;80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer
OD109129/2023-2024:Supplying, fixing of gate light fitting similar to Philips Cat No. HPC 11/Crompton Greaves/Bajaj with all accessories with 40 watts LED lamp with suitable G.I. bracket
OD109132/2023-2024:Supplying, fixing of the 16A SP MCBs in a suitable size MS enclosure and angle iron frame for controlling street lights.
OD109135/2023-2024:MS Items.-Supply and fixing of 6mm thick checkered plate with required M.S. angle/plate supports over the masonry cable trench at substation and electrical control room. Angle and plate should be painted one coat of primer and two coats of enamel paint as required
OD109137/2023-2024:Supply and fixing of MS angle/supports for cable trays for clamping of cables in trenches/ through walls and trusses etc. Angles and plates should be painted one coat of primer and two coat of enamel paint as required as per KEI standards.
OD109165/2023-2024:Safety Items-Supply and providing the following safety items approved by Kerala Electrical Inspectorate and relevant standards.
OD109166/2023-2024:Provisions for transformer plinth
OD109169/2023-2024:Obtaining statutory approval from Eletrical Inspectorate including preparation of drawings, obtaining approval for the drawings arranging inspection of the installations and obtaining safety certificate etc.after completion of the work.The necessary statutory fees if any payable to the Electrical Inspectorate/ KSEB will be paid by KWA.
Bidder Name
Kannan K
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid