Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.2 LAccepted-AOC 0 BEECHPARA DANGAURA MAHENDRAGARH MANENDRAGARH CHIRMIRI BHARATPUR CHHATTISGARH 497442 | KOREA | CHHATTISGARH | 497442 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹10.8 L+₹1.5 L (16.6%)Rejected-Finance | L2 | Rejected-Finance Rejected being L1 |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
1 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (ARMY) CENTRAL JODHPUR
GE (ARMY) CENTRAL MULTAN LINE ARMY AREA JODHPUR
ATTENDING DAY TO DAY MAINT COMPLAINTS PERTAINING TO EM WORKS OF AGE BR I AREA UNDER GE ARMY CENTRAL ARMY AREA JODHPUR (9103/E8)
2022_MES_541975_2
GE/J/A OF 2022-23 (9103/E8)
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (ARMY) CENTRAL MULTAN LINE ARMY AREA JODHPUR
Please refer tender documents
6 documents required · 6 mandatory
₹500
GE (ARMY) CENTRAL JODHPUR
₹30,000
15 Sept 2022
11 Aug 2022
3 Sept 2022
11 Aug 2022
1 Sept 2022
18 Aug 2022
Amount
Note :- (i) All items in BOQ are for "Materials and labour / Supply and fix" and to be executed in "Repairs/ Replacement unless otherwise specifically mentioned as "Supply only" or Fixing only" in BOQ . (ii) Makes of material will be approved by GE in writing before commencement of work.
M&L for Attending daily complaints of Jodhpur Mil area by deputing adequate minimum number (Electrician: 01 , Helpers: 01) of teams of qualified Electrician and helper (round the clock in three shifts of 08 Hrs) for repair, maintenance and making the continuity of supply after rectifying the defects of the electrical system such as switches / sockets / distribution boards / MCB / light / power / lamp holders-bracket / pendent / batten / bell / buzzer / push button / ceiling rose / capacitors and other similar light & power plug, including provisioning of small pieces of electrical cables PVC insulated copper multistranded conductor of sizes 1.5 Sqmm to 6 Sqmm single core and length not increasing 0.50 mtrs complete all as specified and directed by Engr-in-Charge. (Complaint slip shall be part of the bill)., ISI Marked, complete all as specified and as directed. Note:- (i) Contractor shall be fully responsible for Complaint slip/ to prepare Job card prepared and submit to JE/ Engr-in-Charge. on daily basis (ii) This item pertains to attending complaints of light / fan / power point / MCB / DB including other minor items such as insulating tape, screws etc as required to attend the complaint to the entire satisfaction of user/Engr-in-Charge. (iii) Other Items shall be measured and paid if reqd to be replaced under respective item of BOQ
M&L to attend major/ minor fault/ No Light due to any reason like neutreal fail or short circuit complete including petroling for rectfication of complaints etc., ISI Marked, complete all as specified and as directed.
S&F in replacement electronic adapoter for LED light up to 30 watt including taking down old unserviceable electronic adaptor of LED as per sample, ISI Marked, ISI Marked, complete all as specified and as directed. Make : CG or equivalent in Havells/ Bajaj/ Philips.
S&F in replacement Switch piano, flush type, 6 amp, single pole, one way, 230V, ISI Marked including taking down old unserviceable switch, ISI Marked, complete all as specified and as directed. Make : Havell's/ Anchor /Leader/Cona
S&F in replacement Switch piano, flush type, 6 amp, single pole, two way, , ISI Marked, 230V including taking down of old unserviceable switch, ISI Marked, ISI Marked, complete all as specified and as directed. Make : Havell's/ Anchor/ Leader/ Cona
S&F in replacement Switch piano, flush type, 16 amp, single pole, one way, 230V, ISI Marked including taking down of old unserviceable switch, , ISI Marked, ISI Marked, complete all as specified and as directed. Make : Havell's/ Anchor/ Leader/ Cona
S&F in replacement Bell push, AC, 230 Volts, 5 Amps, ISI Marked including taking down of old unserviceable bell push, ISI Marked, complete all as specified and as directed. Make : Havell's/ Anchor/ Leader/ Cona
S&F in replacement Socket out let, flush type, 6 amp 3/5 pin, ISI Marked suitable for 6 Amp plug top 230 V including taking down of old unserviceable socket , ISI Marked, ISI Marked, complete all as specified and as directed. Make : Havell's/ Anchor /Leader/ Cona
S&F in replacement Socket out let, flush type, 3/6 pin, suitable for 16 Amp, ISI Marked, plug top multipurpose 230 V including taking down of old unserviceable socket, ISI Marked, complete all as specified and as directed. Make : Havell's/ Anchor/ Leader/ Cona
S&F in replacement Bell, AC ding dong type/multi music, type 230 volts, including taking down old unserviceable bell, , ISI Marked, complete all as specified and as directed. Make : Havell's/ Anchor/ Leader/ Cona
S&F in replacement Fan regulator electronic switch/ socket type including taking down of old unserviceable regulator, ISI Marked, complete all as specified and as directed. Make : Havell's/ Anchor/ Leader
S&F in replacement Lamp holder insulated body with back plate batten/angle type for batten fittings including taking down old unserviceable holder, ISI Marked, complete all as specified and as directed. Make : Havell's/ Anchor/ Leader/ Cona
S&F in replacement Fan capacitor 2.5 m.f.d for ceiling Fan, including taking down old unserveable capacitor, ISI Marked, complete all as specified and as directed. Make : Havell's/ Anchor/ Bajaj
S&F in replacement Fan capacitor 4 manufactured for Exhaust Fan, including taking down old unserveable, ISI Marked, complete all as specified and as directed. Make : Havell's/ Anchor/ Bajaj
S&F in replacement Ceiling rose 3 terminals complete including taking down, ISI Marked, complete all as specified and as directed. Make : Havell's/ Anchor/ Leader/ Cona
S&F in replacement Modular switch any type and make 6 amp one way 230 V including taking down of old unserviceable switch, ISI Marked, complete all as specified and as directed. Make : Legrand/ ABB/ Schneider
S&F in replacement Modular switch any type and make 16 amp one way 230 V including taking down of old unserviceable switch, ISI Marked, complete all as specified and as directed. Make : Legrand/ ABB/ Schneider
S&F in replacement Modular socket Any Type and make, 6 amp 5 Pin one way 230 V, ISI Marked, complete all as specified and as directed. Make : Legrand/ ABB/ Schneider
S&F in replacement Modular socket Any Type and make, 16 amp 5 Pin one way 230 V including taking down of old unserviceable switch, ISI Marked, complete all as specified and as directed. Make : Legrand/ ABB/ Schneider
S&F in replacement Modular switch any type and make 6 amp two way 230 V including taking down of old unserviceable switch, , ISI Marked, ISI Marked, complete all as specified and as directed. Make : Legrand/ ABB/ Schneider
S&F in replacement Modular fan Regulator step type and make, 100 watt , 230 Volts including taking down of old unserviceable regulator, , ISI Marked, ISI Marked, complete all as specified and as directed. Make : Legrand/ ABB/ Schneider
S&F in replacement Modular cover plate with frame 4 module type for fixing of modular switch socket, regulators, blank plates etc including taking down old unserviceable cover plate, ISI Marked, complete all as specified and as directed.
S&F in replacement Modular cover plate with frame 8 module type for fixing of modular switch socket, regulators, blank plates etc including taking down old unserviceable cover plate, ISI Marked, complete all as specified and as directed.
S&F in replacement Modular cover plate with frame 12 module type for fixing of modular switch socket, regulators, blank plates etc including taking down old unserviceable cover plate, ISI Marked, complete all as specified and as directed.
S&F in replacement Poly carbonate transparent energy meter protection cover temper proof suitable for single phase energy meter etc including of old unserviceable protection cover, ISI Marked, complete all as specified and as directed.
S&F in replacement PVC conduit including fitting such as tee, elbow, bend etc., 20mm dia (ISI Marked) (MMS) grade, including taking down old unserviceable conduit, , ISI Marked, ISI Marked, complete all as specified and as directed. Make : Polycab/ Plaza/ Kalinga
S&F in replacement PVC cassing capping Tee, Elbow, Bend etc., 20/25 mm dia (ISI Marked) (MMS) including taking down old unservecable cassing capping, , ISI Marked, ISI Marked, complete all as specified and as directed. Make : Polycab/Plaza/Kalinga
Taking down fan, sealing cable end,dismantling blades and removing fan and blades to store or repair and refixing in same position including connector from ceiling rose to fan connector, complete all as directed.
Taking down exhaust fan and refixing and connecting up including provision of cable from ceiling rose to connector to fan, complete all as directed.
S&F in replacement Prewired distribution board SPN 4 way, double door, in sheet metal enclosure with 200 Amps rated copper bus bar Confirming to relevant IS., 240 V for fixing MCB's, IP 43 protection, including taking down old UNSV DB, complete all as specified & directed by Engg.-in-charge. Note -Rate are deemed to be included for flashing in wall concealed complete, making good and matching existing surface. Make : Legrand/ ABB/ Schneider
S&F in replacement Prewired distribution board SPN 8 way, double door, in sheet metal enclosure with 200 Amps rated copper bus bar Confirming to relevant IS., 240 V for fixing MCB's, IP 43 protection, including taking down old UNSV DB, complete all as specified & directed by Engg.-in-charge. Note -Rate are deemed to be included for flashing in wall concealed complete, making good and matching existing surface, complete all as specified and as directed by Engr-in-charge. Make : Legrand/ ABB/ Schneider
S&F in replacement Prewired distribution board TPN 8 way, double door, in sheet metal enclosure with 200 Amps rated copper bus bar Confirming to relevant IS., 415 V for fixing MCB's, IP 43 protection, including taking down old UNSV DB, complete all as specified & directed by Engg.-in-charge. Note -Rate are deemed to be included for flashing in wall concealed complete, making good and matching existing surface, complete all as specified and as directed by Engr-in-charge. Make : Legrand/ ABB/ Schneider
S&F in replacement MCB Single pole"C" series 5-32 Amps (ISI Marked) including taking down old unserviceable MCB SP, , ISI Marked, ISI Marked, complete all as specified and as directed. Make : Legrand/ Schneider / ABB
S&F in replacement MCB Single pole & neutral "C" series 40 Amps (ISI Marked) including taking down old unserviceable MCB SPN, ISI Marked, complete all as specified and as directed. Make : Legrand/ Schneider / ABB
S&F in replacement MCB Single pole & neutral "C" series 63. Amps (ISI Marked) including taking down old unserviceable MCB SPN, ISI Marked, complete all as specified and as directed. Make : Legrand/ Schneider / ABB
S&F in replacement MCB TPN C Curve 63 Amps Make including taking down of old unserviceable TPN MCB, ISI Marked, complete all as specified and as directed. Make : Legrand/ Havells/ ABB/ Indo Asian
S&F in replacement MCCB 100 Amp TPN, 415 volts 16 KA rupturing capacity including proper thimbles, fixing on DB'S including taking down of old unserviceable TPN MCCB, ISI Marked, complete all as specified and as directed. Make : Legrand/ Havells/ ABB/ Indo Asian
S&F in replacement MCCB 125 Amp TPN, 415 volts 16 KA rupturing capacity including proper thimbles, fixing on DB'S including taking down of old unserviceable TPN MCCB, , ISI Marked, ISI Marked, complete all as specified and as directed. Make : Legrand / Havells/ ABB/ Indo Asian
S&F in replacement electronic driver as per sample for LED fitting up to 15 watt including taking down old unserviceable driver, , ISI Marked, ISI Marked, complete all as specified and as directed. Make : Havells/ CG/ Philips/ Osram.
S&F in replacement electronic driver as per sample for LED fitting up to 45 watt including taking down old unserviceable driver, , ISI Marked, ISI Marked, complete all as specified and as directed. Make : Havells/ CG/ Philips/ Osram.
Taking down bldg security light upto 45 watt and refixing the same after repiar, Electronic driver are paid sepearately under sch A, complete all as directed.
M&L in replacement remote bell ding dong type including taking down old UNSV bell, complete all as specified and as directed by Engr-in-charge.
S&F in replacement 2-Watt LED Wall Light (bed light) for reading including taking down old UNSV light, complete all as specified and as directed by Engr-in-charge. Make : Philips 30975 or equivalent in Havells/ crompton.
S&F in replacement round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete including taking down old UNSV light, , ISI Marked, ISI Marked, complete all as specified and as directed. Make : Philips/ Bajaj/ CG
S&F in replacement Spot light 6 Watts Black/ white Body LED Spot Light, Focus Light (Warm White) including taking down old UNSV light, complete all as specified and as directed by Engr-in- charge. Make : Philips/ CG/ Bajaj
S&F in replacement PVC insulated and unsheathed FRLSH single core multistranded copper conductor for repair, in existing conduit of size 1.5 sqmm as in replacement of any defective/ burnt circuit including taking down old UNSV cable, ISI Marked, complete all as specified and as directed.
S&F in replacement, PVC insulated and unsheathed FRLSH single core multistranded copper conductor, in existing conduit of size 2.5 sqmm as in replacement of any defective/burnt circuit including taking down old UNSV cable, , ISI Marked, ISI Marked, complete all as specified and as directed.
S&F in replacement, PVC insulated and unsheathed FRLSH single core multistranded copper conductor, in existing conduit of size 4.0 sqmm as in replacement of any defective/ burnt circuit including taking down old UNSV cable, , ISI Marked, ISI Marked, complete all as specified and as directed.
S&F in replacement repair PVC insulated and unsheathed FRLSH single core multistranded copper conductor, in existing conduit of size 6.0 sqmm as in replacement of any defective/burnt circuit including taking down old UNSV cable, ISI Marked, complete all as specified and as directed.
S&F in replacement Street light bracket made out of medium grade GI Pipe 32mm dia 1.00 Mtr long, bent to shape including GI Clamps nut,bolts washers,reducer of required size for suitable any type fittings etc complete including necessary painting and taking down old UNSV GI Bracket, complete all as specified and as directed by Engr-in Charge.
S&F in replacement Modular Bell push any type and make 6 amp one way 230 V taking down old UNSV bell push, , ISI Marked, ISI Marked, complete all as specified and as directed. Make : Legrand/ ABB/ Schneider
Taking down carefully copper/aluminium point wiring for light, fan, bell socket power slocket etc complete with boards, outlet boxes fittings and fixtures such as switchs, sockets, lamp holders bracket, ceiling rose etc., complete all as directed.
M&L for point wiring using approved colour coding as per IS code for single phase with 1.5 Sq mm single core PVC insulated but unsheathed multistranded copper conductor FRLSH cable 1100 volts grade confirming to IS 694 marked with valid CML No., drawn through and includingPVC casing & caping in wall / roof / floor etc, including boxes, etc ISI marked with valid CML No. (IS 9537 - 1983) fixed recessed in wall or ceiling etc including 1.5 Sq mm, single core, PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 Volts grade as earth continuity wire connected to earth dolly and including surface mounted PVC gang box with modular sheet of same make of switch/ socket/ regulator with sleek and curvy cover plates, for mounting of modular switches, sockets, fan regulators complete for the following, complete all as specified and as directed :- (a) One light/fan/bell point controlled by one, one way switch.
(b) All as per item No. 54.00 above but One fan point controlled by one way switch.
(c) All as per item No. 54.00 above but One socket outlet 3 pin 5/6 Amps on same board
(d) All as per item No. 54.00 above but One socket outlet 3 pin 5/6 Amp on independent board
(e) All as per item No. 54.00 above but One bell point controlled by one bell push.
(f) All as per item No. 54.00 above but One light point controlled by two, two-way switches
All as per item No. 54.00 above but using 2.5 Sq mm single core multistanded copper conductor cable including 2.5 sq mm PVC insulated unsheathed stranded copper conductor for common earth wire for 6 pin 16 Amp socket outlet on independent board, ISI Marked, complete all as specified and as directed.
M&L Point wiring using approved colour coding as per IS code with multi stranded copper conductor, nominal cross-sectional area is 1.5 sq mm , single core, PVC insulated and unsheathed FRLSH cable 1100 Volts grade, ISI-694 marked with valid CML No.in and including heavy duty drawn through and including in PVC rigid conduit with all accessories complete concealed in wall/roof/floor or surface on roof / hard surface etc, ISI marked with1.6mm thick mild steel/prestressed steel sunken/concealed box (with earth dolly), with 3 mm thick plastic laminated sheet cover for fixing of switches, sockets and fan regulators etc, inciuding PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly for,one way switch One light/ fan/bell point controlled by one, one way switch complete all as specified and directed . (a) One light point controlled by one, one way switch
(b) All as per item No. 61.00 above but One fan/ Exhaust Fan point controlled by one way switch.
(c) All as per item No. 61.00 above but One socket outlet 3 pin, 5 Amps on independent board, controlled by one no 5 Amp switch.
(d) All as per item No. 61.00 above but One socket outlet 3 pin 5 amps on the same board controlled by one no 5 Amp switch.
(e) All as per item No. 61.00 above but One bell point controlled by one bell push.
(f) All as per item No. 61.00 above but One light point controlled by two, two-way switches
All as per item No. 61.00 above but with using 2.5 Sq mm single core multistanded copper conductor cable including 2.5 sq mm PVC insulated unsheathed stranded copper conductor for common earth wire for 6 pin 16 Amp socket outlet on independent board, ISI Marked, complete all as specified and as directed.
S&F in replacement one bakelite sheet not less then 3mm thick after removing all connection including cutting/chassing to accommedate existing fitment and making connection including cadmium plated screws with cup washer of following sizes, complete all as specified and as directed:- (a) 275 x 225 mm
All as per item No. 68.00 here-in-above, but size of 225 x 200mm
All as per item No. 68.00 here-in-above, but size of 175 x 125 mm
All as per item No. 68.00 here-in-above, but size of 100 x 100 mm
M&L in replacement GLS Coloured Lamp Red,Green,Milky,0-60 Watt, ISI Marked, complete all as specified and as directed. Make : Philps/ Havells/ WIPRO
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, including taking down old UNSV light fitting, complete all as per specified and directed by Engg.-in-charge. Make : Bajaj Cat No. BCLSB 20 WH or Equivalent in Philips/ Havells as approved by GE.
S&F in replacement in replacement LED light fitting 1 X 9 watt (2feet), decorative ultra slim type, with inegral driver, complete with all accessories and making necessary electric connection from ceiling rose to fitting terminal, complete and including taking down old UNSV fitting, , ISI Marked, ISI Marked, complete all as specified and as directed. Make : Havells/ Wipro/ Philips
S&F in replacement in replacement LED Bulb threaded types in holders 0 to 15 Watts as per existing sample given by department, , ISI Marked, ISI Marked, complete all as specified and as directed. Make : Havells/ Wipro/ Legarnd
S&F in replacement in replacement LED Bulb brown in brightness (Warm tpye) 0 to 15 Watts as per existing sample given by department, , ISI Marked, ISI Marked, complete all as specified and as directed. Make : Havells/ Wipro/ Legrand
S&F in replacement LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size incl taking down old UNSV Bulkhead fitting, , ISI Marked, ISI Marked, complete all as specified and as directed. Make : Philips/ Havells/ CG
S&F in replacement in replacement LED Bulb 9 Watts as per existing sample given by department, , ISI Marked, ISI Marked, complete all as specified and as directed. Make : Philips/ Havells/ Wipro/ Legrand
Note :- (i) Contract Sum shall be arrived at after deduction of amount of Schudule of Credit.
Narendra General Suppliers
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .