Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.6 LAccepted-AOC | L1 | Accepted-AOC Accepted being lowest and reasonable one. | |
| 2 | L2₹41.0 L+₹2.3 L (5.82%)Rejected-Finance | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹41.6 L+₹2.9 L (7.39%)Rejected-Finance A 23 TRIBUNE COLONY AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L3 | Rejected-Finance Rejected being L3 |
| Sl No | Description | Qty | Unit | Swami Enterprises L2 | M/s AVINASH CHANDER GUPTA L3 | Parveen Kumar L1 |
|---|---|---|---|---|---|---|
| 1.00 | [B&R PORTION]
Demolition of brick work built in CM including all quions arches, pillar etc complete all as specified and directed by Engineer-in-Charge. | 10 | CUBIC METER | 125 ₹1,250 | 150 ₹1,500 | 106 ₹1,060 Lowest |
| 2.00 | Material and labour for brick work with old size sub class ‘B’ bricks,straight or curved on plan to any radius built in cement mortar 1:4 complete all as specified and directed. | 8 | CUBIC METER | 4,200 ₹33,600 | 5,000 ₹40,000 | 3,400 ₹27,200 Lowest |
| 3.00 | All as per Item No 02.00 here in before but except bricks complete all as specified and directed by Engineer-in-Charge. | 2 | CUBIC METER | 2,100 ₹4,200 | 1,500 ₹3,000 Lowest | 1,700 ₹3,400 |
| 4.00 | Taking down cement plaster on brick or stone walls including raking out joints hacking for key and scrubbing down with water etc complete all as specified and directed. | 600 | SQUARE METER | 11 ₹6,600 | 20 ₹12,000 | 9.8 ₹5,880 Lowest |
| 5.00 | Material and labour for rendering 15 mm thick on fair faces of brick work or concrete surfaces, finished even and smooth (without using extra cement) on walls in cement mortar 1:6, complete all as specified and directed. | 500 | SQUARE METER | 160 ₹80,000 | 200 ₹1,00,000 | 133 ₹66,500 Lowest |
| 6.00 | Material and labour for rendering 15mm thick on fair faces of brick work or concrete surfaces, finished even and fair on walls in cement mortar 1:4, using water proofing compound complete all as specified and directed.
NOTE: WPC will be measured and paid for separately. | 100 | SQUARE METER | 160 ₹16,000 | 220 ₹22,000 | 147 ₹14,700 Lowest |
| 7.00 | Supply only integral water proofing comound complete all as specified and directed by Engineer-in-Charge. | 5 | LITRE | 51 ₹255 | 50 ₹250 | 34 ₹170 Lowest |
| 8.00 | Material and labour for preparation of exposed brick wall surface by cleaning the surface with wire brush to remove all dirt/loose materials from the bricks and from the joints between the bricks. Prepared surface should be then washed with diluted HCL acid (dilution ratio of 1:50) for three times in a day for two days. After acid wash surface should be allowed to be air dried for one day.
Note : Further treatment over the surface so achieved will be carried out only after approval of the same by GE. Note:- This item shall be executed by authorised applicator only. for carrying out efflorescence treatment to exposed and prepared wall surface here–in–above in following sequence :–
(a) Prime the prepared surface with one of the following product mixed with cement in 1:1 ratio as bonding agent :–
(i) Pidicrete URP of M/S Pidilite (ii) Sika Latex of M/s Sika (iii) Nitobond SBR Latex of M/s FOSROC (b) Immediately after priming the surface PMM (Polymer Modified Mortar) to be applied "BY HAND" while the primer is tacky. PMM should be prepared by mixing one of the following compounds in Cement Mortar 1:3 as per manufacturer's instructions :–
(i) Pidicrete URP of M/S Pidilite (ii) Sika Latex of M/s Sika (iii) Nitobond SBR Latex of M/s FOSROC (c) PMM surface should be allowed to dry one day. After that it should be painted with two coats of one of the following compound mixed with cement only in ratio of one part of selected compound and one point fire part of cement :–
(i) Pidicrete URP of M/S Pidilite (ii) Sika Latex of M/s Sika (iii) Nitobond SBR Latex of M/s FOSROC (d) Now apply two coats of one of the following compound over the surface. These compounds are to be used as per manufacturer instructions :– (i) Pidifin 2K of M/S Pidilite (ii) Brush Coat of M/s Sika (iii) Brush Bond of M/s FOSROC Note : Both coats should be perpendicular to each other and gap between two coats shall be minimum 6 hours.
(e) Sprinkle loose coarse sand after second coat while surface is tacky. Note: (i) Item will be executed by authorised applicator of the selected /approved company only. (ii) Every stage of work will be approved by GE then only next layer will be executed by contractor. | 50 | SQUARE METER | 211 ₹10,550 Lowest | 300 ₹15,000 | 340 ₹17,000 |
| 9.00 | Material and labour for applying Two or more coats of 100 % Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS-15489:2004, Alkali and fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 ltre/10 Sqm over and icluding priming coat of exterior primer applied @ 0.90 litre/10 Sqm over new surfaces complete as all specified and directed by Engineer-in-Charge. | 100 | SQUARE METER | 70 ₹7,000 | 70 ₹7,000 | 52 ₹5,200 Lowest |
| 10.00 | Material and labour for applying Two or more coats of 100 % Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS-15489:2004, Alkali and fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 ltre/10 Sqm over and icluding priming coat of exterior primer applied @ 0.90 litre/10 Sqm over Old surfaces complete as all specified and directed by Engineer-in-Charge. | 300 | SQUARE METER | 70 ₹21,000 | 65 ₹19,500 | 52 ₹15,600 Lowest |
Tender Value
₹47.0 L
EMD Value
₹94,004
Closing Date
2 Feb 2026, 6:00 pmClosed
LT COL CHETAN KOTKAR, GE (SOUTH) AMBALA
GE (SOUTH) AMBALA CANTT
CA NO GE(SOUTH)/AMB-65/2025 2026 SPECIAL REPAIR TO CERTAIN BLDGS ALONGWITH PROVN OF 7 GEYSERS FOR BATHROOM OF SINGLE LIVING ACCN UNDER GE (SOUTH) AMBALA CANTT
2026_MES_748058_1
GE(SOUTH)/AMB-65/2025-2026
Open Tender
Civil Works
Item Rate
180 days
GE (SOUTH) AMBALA CANTT
AS PER NIT
9 documents required · 9 mandatory
₹500
GE (SOUTH) AMBALA CANTT
₹94,004
Yes
16 May 2026
10 Jan 2026
4 Feb 2026
10 Jan 2026
2 Feb 2026
26 Jan 2026
10 Jan 2026 - 24 Jan 2026
[B&R PORTION] Demolition of brick work built in CM including all quions arches, pillar etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for brick work with old size sub class ‘B’ bricks,straight or curved on plan to any radius built in cement mortar 1:4 complete all as specified and directed.
All as per Item No 02.00 here in before but except bricks complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster on brick or stone walls including raking out joints hacking for key and scrubbing down with water etc complete all as specified and directed.
Material and labour for rendering 15 mm thick on fair faces of brick work or concrete surfaces, finished even and smooth (without using extra cement) on walls in cement mortar 1:6, complete all as specified and directed.
Material and labour for rendering 15mm thick on fair faces of brick work or concrete surfaces, finished even and fair on walls in cement mortar 1:4, using water proofing compound complete all as specified and directed. NOTE: WPC will be measured and paid for separately.
Supply only integral water proofing comound complete all as specified and directed by Engineer-in-Charge.
Material and labour for applying Two or more coats of 100 % Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS-15489:2004, Alkali and fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 ltre/10 Sqm over and icluding priming coat of exterior primer applied @ 0.90 litre/10 Sqm over new surfaces complete as all specified and directed by Engineer-in-Charge.
Material and labour for applying Two or more coats of 100 % Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS-15489:2004, Alkali and fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 ltre/10 Sqm over and icluding priming coat of exterior primer applied @ 0.90 litre/10 Sqm over Old surfaces complete as all specified and directed by Engineer-in-Charge.
Material and labour for plaster wall care putty of 1.5mm thickness over plastered surface to prepare the surface even and smooth complete as all specified and directed by Engineer-in-Charge.
Material and labour for two coats of acrylic distemper over a coat of primer of Chalk whiteing on newly plastered surfaces or prepared surface complete as all specified and directed by Engineer-in-Charge.
Material and labour for complete removal of existing treatment and applying two coats of oil bound distemper on wall over a coat of 2mm thick birla wall care putty including preparation of surface complete as all specified and directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
Material and labour 40mm thick cement concrete Type 1:2:4 B0 (using 12.5mm graded stone aggregate) as in floor finished rough to recieve floor finishes etc complete as all specified and directed by Engineer-in-Charge.
Material and labour for First quality, Non skid ceramic, coloured, rectified i.e. straight edge (locally known as joint free) tiles of size 600 x 600mm each and of thickness not less than 7mm, in skirting etc. over and including 10 mm thick plaster in cement mortar (1:4), set and jointed with tile adhesive with notched trowel and pointed in grout of matching shade of tiles, complete as all specified and directed by Engineer-in-Charge.
Material and labour for non skid coloured ceramic tiles 400 x 400 x 7 to 8 mm set and jointed with neat cement slurry and pointed in white/coloured cement to match the tiles over and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
Material and labour for glazed ceramic coloured tiles 450x350x7 mm thick on vertical surface such as skirting , dado etc. over 10 mm thick backing coat plaster in CM 1:4 complete all as specified and directed.
Supply and fixing for heavy duty tiles (coloured), good grip series, size 300 mm x 300 mm x 10 mm thick, pattern as approved by Engineer-in-Charge, set, jointed and pointed in neat cement slurry @ 3.00 kg/square metre, laid over and including 20 mm thick (average thickness) cement mortor 1:4 screed complete as all specified and directed by Engineer-in-Charge. (Note: Design/pattern shall be as approved by GE before execution of work)
Taking down chowkaths or frames not.exc 1.5 sqm (without taking off shutter from the frame) each and removing from the site including dismantling brick work for hold fasts etc complete as all specified and directed by Engineer-in-Charge.
Taking down chowkaths or frames exc 1.5 sqm but not.exc 4 sqm (without taking off shutter from the frame) each and removing from the site including dismantling brick work for hold fasts etc complete as all specified and directed by Engineer-in-Charge.
Dismantling structural steel work including doors, gates but excluding framed truss etc complete as all specified and directed by Engineer-in-Charge.
Supply and fixing of Factory made single extruded WPC (Wood Polymer Composite) solid door Frames/Chowkhat of size 100 x 65 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) and 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant, complete all as specified and directed by Engineer-in-Charge. Note: For WPC solid door frames, minus 5mm tolerance in Dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
Supply and fixing of Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 35mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) and 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant complete as all specified and directed by Engineer-in-Charge.
Supply and fixing of stainless steel butt hinges 100 mm long medium weight complete all as specified and directed.
Supply and fixing aluminium anodised extruded fabricated type handle 100mm long complete all as specified and directed.
Supply and fixing 150 mm long Aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and directed.
Supply and fixing of mild steel pressed handle, 150mm long, oval type, stove enameled black, complete all as specified and directed.
Supply and fixing of 250 mm long mild steel sliding door bolts ,plate type, stove enamelled black,with bright bolt not less than 12mm with and including a minimum of 6 bolts and nuts , four on bolt plate and two on staple plate complete all as specified and directed.
Material and labour for mild steel work as in hold fasts etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for PCC 1:3:6 type C-1 (20 mm graded mechanically crushed stone aggregate) as in filling pressed steel frame /hold fast blocks etc complete all as specified and directed.
Supply and fixing of windows made of pre-painted steel (Base steel as per IS 513 of 0.58mm thick “D” Quality galvanized as per IS 277 with zinc of 120 GSM). Primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7 microns thick alkyd backer. Section for outer frame should be of 72x55mm, centre mullion should be of 72x50mm, section for fixed glass beading should be of 12x12mm and section for shutter should be of 52 x 25mm. Outer frame and mullion sections to have rebate for glazed shutters, fly mesh and 20 mm provision for guard bars/ grills fly mesh shutter section should be of 20x40mm. The sections are to be cut to length mitre joined with corner bracket. Centre mullions to be fixed with mullion cap. Elixir or equivalent stay, handles 2nos of heavy duty stain less steel pivot hinges shall be provided per shutter. The windows should be panelled with 4 mm thick plain float glass and S.S. Mesh for fly mesh shutter (304 grade). Rubber Gaskets are provided all around the glass. The above frames should be fixed to the concrete/masonry wall by means of self expanding screws. Including 10mm square guard bars with 6” (152.4mm) pitch, complete for finished with suitable provision for Window AC complete all as specified and directed by the Engr-in-Charge
Supply and fixing Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete as all specified and directed by Engineer-in-Charge.
Supply and fixing Plain Sheet glass 4 mm thick, ordinary quality and glazing with linseed oil pane putty and spring glazing clips, in squares not exceeding 0.5 Sq. m in each pane, complete all as specified.
Supply and fixing in repair stainless steel curtain rod 25mm dia having wall thickness 1.6mm fixed with and including stainless steel decorative brackets, two lotto for each rod length at both ends etc, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing 150 mm overall length of cover plate Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete as all specified and directed by Engineer-in-Charge.
Supply and fixinge GI tubing medium grade 20 mm dia including fittings, cutting threading and fixing to walls or fixing in concealed walls or in floors etc, and making good the surfaces matching to exsiting surafaces of walls/ floor to the entire satisfaction of Engineer-in-charge, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs, Vitreous china wash down water closet pan (Pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe, P or S trap,) complete as all specified and directed by Engineer-in-Charge.
Supply and fixing in repair 10 ltr capacity PVC valveless, syphonic action type flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, 32 mm dia flush pipe complete as all specified and directed by Engineer-in-Charge.
Supply and fixing in repair vitreous china wash hand basin white flat back of size 550x440mm including CI brackets , chromium plated waste coupling, waste pipe etc.,complete all as specified and directed.
Supply and fixing vitreious China urinals half stall type complete including plug waste pipe etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of pillars taps fancy type chromium plated cast copper alloy with capston head long screwed shanks of 15mm bore compete all as specified and directed by Engineer-in-Charge.
Supply and fixing Two way angle valve/cock chromium plated brass fancy type bore 15 mm complete all as specified and directed.
Supply and fixing in repair 15 mm fancy type chromium plated bib tap brass long body with flange screwed down high pressure CP cast copper alloy with crutch or butterfly handles scrwed down suitable for 15mm bore pipe or union complete all as specified and directed by Engineer-in-Charge.
Supply and fixinged in repairs stainless steel grating openable 100mm size with/without hole including fixing with white cement complete as all specified and directed by Engineer-in-Charge.
Supply and fixing in repair angle valve cock chromium plated fancy type 15 mm bore with flange make L and K code No 077A or equivalent complete all as specified and directed by Engineer in Charge.
Supply and fixing in repair 15mm bore Gun-Metal, globe or gate valves , with iron wheel head,screwed down both end for iron pipe and fixed complete all as specified and directed by Engineer in Charge.
Supply and fixing in repair Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions, all as specified, of 15mm bore, fancy type, chromium plated with long shank and cup (Concealed type), complete as all specified and directed by Engineer-in-Charge.
Supply and fixing in repair Soap dish any type, fixed to plugs with chromium plated brass screws complete as all specified and directed by Engineer-in-Charge.
Supply and fixing in repair chromium plated, towel rail, 20mm dia, D type, 60cm long between flanges complete as all specified and directed by Engineer-in-Charge.
Supply and fixing in repair for PVC connections 15mm size with PTMT nuts of length 450mm, complete as all specified and directed by Engineer-in-Charge.
Supply and fixing for 110mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls /trenches including dismantling of existing pipes of any description any length complete all as specified and as directed..
Supply and fixing PVC (SWR) 75 mm pipe type A single socketes in any length with rubber ring joints laid in floors or trenches including dismantling of existing pipes of any description any length complete all as specified and as directed.
Supply and fixing of 40 mm bore PVC (SWR) junction single T (equal or unequal), including jointing with solvent cement, complete all as specified and directed.
Supply and fixing PVC(SWR) bends, for 110mm bore pipes, with access doors, complete all as specified and directed by Engineer in Charge.
Supply and fixing of PVC (SWR) bends 75 mm bore complete all as specified and directed by Engineer in Charge.
Supply and fixing of 110 mm bore PVC (SWR) junction single T (equal or unequal), including jointing with solvent cement, complete all as specified and directed.
Supply and fixing of 75 mm bore PVC (SWR) junction single T (equal or unequal), including jointing with solvent cement, complete all as specified and directed.
Material and labour for 1000 Litres rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top and FDA approved, tripple layer body, 100% UA stablised, rust proof) hoisted and fixed in position complete all as specified in SSR Part-I, and as directed by the Engr-in-Charge. Note : Water storage tank shall be White colour, complete as all specified and directed by Engineer-in-Charge.
Dismantelling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings in any position complete all as specified and directed by Engineer in Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for purlin/rafters ,gates, staircase railings, framed truss etc complete all as specified and directed.
Supply and fixing,structural rolled mild steel Fe 410-00 (Gde E-250) as in post rafters perlins where connected to common rafters and running rail fixed with angle cleats or other connecting plates etc complet all as specified and directed.
Supply and fixing in repair Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc complete all as specified and as directed by Engr-in-charge.
Supply and fixing in repair Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc complete all as specified and as directed by Engr-in-charge.
Material and labour for preparing new steel surfaces of any description , over 10 cm width or girth and applying two coats of synthetic enamel paint(first quality) over a coat of red oxide primer complete all as specified and directed
Material and labour for preparing old steel surfaces of any description , over 10 cm width or girth and applying one coats of synthetic enamel paint(first quality) complete all as specified and directed
Supply and fixing false celling at all heights with 12mm Thick Micro Beveled Edged GRG (Glass Fibre Reinfroced Gypsum CaSo4-2H2O) false celling files of Size 595X595 mm of approved texture, design and patterns having mositure content less than 2%, humidity resistance of 99%, NRC 0.06 (Minimum Certified) as per Is 8225.1987, Non-combustible (Certified) as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick galvanized @ 120 gram per sqm including both side) comprising of main-T runner of size 15x32 mm (Silhoutte) of length 3000 mm, cross-T of size 15X32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm, suspended from celling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod or 4mm diaGI wire up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanized iron perimeter wall angle of size 24x24x0.40 mm of length of 3000 mm to be fixed on periphery wall/ partition with the help of plastic rawl plugs at 450 mm centre to centre and 40 mm long dry wall wood screws With Semi Perforated 12mm Thick Micro Bevelied Edge GRG False Celling Tiles. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge.
Demolition of cement concrete (unreinforced) in ground floor and paving not.exceeding 15cm thickness (below or above GL) and disposing off debris outside MD land complete all as specified and as directed
Material and labour for 75mm thick PCC type D-2, (1:4:8) using 40mm graded stone aggregate as in sub base complete as all specified and directed by Engineer-in-Charge.
Material and labour for 60mm thick machine pressed rubber moulded precast concrete M-35 interlocking coloured paver block any shape and size conforming to IS-15658-2006 with grey cement and pigment complete all as specified and as directed.
Material and labour for 50mm thick Sand filling under floors including watering and consolidation, complete as all specified and directed by Engineer-in-Charge.
[E&M PORTION] Taking down carefully aluminium/ copper point wiring (light, fan,socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators , sockets, light fittings etc., removing materials to stores for keeping in safe custody for taking credit and making good the disturbed surfaces of walls,ceilings etc complete as all specified and directed by Engineer-in-Charge.
Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor drawn through and including PVC conduit not less than 20mm dia with and including accessories, concealed on wall/ and surface on ceiling and its fittings including all tees, bell mouth pieces and fixing accessories such as couplers, saddlers, pipe hooks etc, PVC junction boxes ISI marked with GI metal flush boxes made out of 1.2mm thick of any module from 2 to 18 module confirming to IS-5139(pt-I) of 1969 and IS:14772-2000 including modular cover plates with frame i.e. inner and outer plate extended upto 25 mm over metal flush boxes for housing the modular switches, socket outlets, fan regulators etc with brass screws and brass washers and making good the disturbed surfaces as per existing for one light / fan / Bell point contorlled by one switch including 1.5 sqmm single core PVC insulated and unsheathed FRLSH (FIRE Retardant Low Smoke and low Halogen) copper cable, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor upto common earth and connecting to common earth dolly with suitable size of lugs for one light point/ fan point/bell point controlled by one switch complete all as specified and as directed. NOTES:- 1. Switch, socket and fan regulators to be measured and paid for separately. 2. All chases will be cut by chase cutter only.
Description all as per item No 74.00 here in before but for socket out let point 6 Amps on same board, complete as all specified and directed by Engineer-in-Charge.
Description all as per item No 74.00 here in before but for socket out let point 6 Amps on independent board, complete as all specified and directed by Engineer-in-Charge.
All as per srl item No 74.00 here in before but point wiring for one socket out let 16 & 6 Amps (independent) controlled by one switch with using 2.5 Sq mm (nominal area) stranded copper conductor
Supply and fixing ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified and directed by Engineer in Charge.
Supply and fixing modular switches, one way, 6 amps one module, 230V, 50 Hz supply, complete all as specified and directed.
Supply and fixing modular switches, one way, 16/20 Amps, one module, 230 volt , AC supply, complete all as specified and directed.
Supply and fix modular socket outlet 6 amps, 2/3 pin combined 2 module, 230 volt, complete all as specified and directed.
Supply and fix modular socket outlet 6/20 amps,3 pin, 2 module, complete all as specified and directed.
Supply and fix modular fan regulator step type one module / 2 module, 100w 230 Volts, 50 Hz, AC complete all as specified and directed.
Supply and fixing of LED luminaries of capacity 20 watt integrated aluminium batten with including Oppel diffuser complete including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and as directed.
Supply and fix surface mounted LED tube light fitting with high efficient diffuser mirror light, aluminium housing in CRCA body suitable and including 10 watt LED tube high efficient, AC 220-240 volts, 50 Hz and connecting with copper conductor flexible cable of size 0.50 Sqmm from ceiling rose to connector of the light complete all as specified and directed.
Supply and fix in repair recess/ surface mounted LED flat panel 2' x 2' with high efficient LEDs and glare free full decorative light fitting, 36 watt, energy efficient provided with including LED 36 watt with provision of 2/3 core PVC copper conductor cable 1.5 Sqmm size to light fitting complete all as specified and directed.
Supply and fixing Bulk Head Fitting 10 Watt and connected with copper conductor cable of size 1.50 Sqmm, for fixing the light fitting complete all as specified and directed.
Supply and fixing in repair of bracket for security light made up of 40/50mm dia suitable for security light, 0.6 metre long GI pipe, light grade, 120 degree bent to required length, fixed to wall with two clamps made of 20 x 3 mm mild steel flat minimum 15cm long, 4 nos 8mm dia bolts with nuts complete all as specified and directed.
Supply and fix LED security light luminaire 30/35 watt , pressure die cast aluminum housing, toughened heat resistant glass, IP65 protection, better optics for uniform distribution with multiplte LEDs not less than 2 W each and having optical grade polycarbonate lens with all accessories internally pre wired and including connecting up with Two core 1.5 sq mm copper conductor cable from connector to ceiling rose to connection of light complete all as specified and directed.
Supply and fix sheet metal enclosures vertical distribution board VTPN,(MCCB DB) 4 ways, double door , 415 volts with 200 amps rated bus bar IP 54 protection, with shrouded neutral bar and insulated bus bar and earth link, with and including MCCB 4 pole adjustable thermal release type ,100 AMPS ,16 KA as incomer and MCBs as out going complete with making suitable size of MS cabinet 1.2 mm thick dully grouted on the wall (flush) with opening arrangement including making connections with suitable size of lugs and making good the disturbed surface matching with existing surface complete all as specified and directed.
Supply and fixing in repair SPN distibution board 8 way, double door, IP 43, as per IS 8623 including 200 amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles complete all as specified and directed.
Supply and fixing 240 V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 Amp, in the MCB DB complete with connection testing and commissioning complete as all specified and directed by Engineer-in-Charge.
Supply and fixing 240 V, 10 KA 'B' curve miniature circuit breaker (MCB) of SPN and current carrying capacity 40 to 63 Amp, in the MCB DB complete with connection testing and commissioning complete as all specified and directed by Engineer-in-Charge.
Supply and fixing 240 V, 10 KA 'B' curve miniature circuit breaker (MCB) of SP and current carrying capacity 40 to 63 Amp, in the MCB DB complete with connection testing and commissioning complete as all specified and directed by Engineer-in-Charge.
Material and labour for sub main wiring with two single core FRLSH, PVC insulated unsheathed copper conductor cable 6.0 sqmm drawn in and including rigid non metallic PVC medium grade 25 mm dia concealed conduit with accessories on wall or ceiling with one additional PVC insulated , stranded copper conductor FRLSH of 6.0 sqmm,green colour for earth continuity conductor including taking down old unserviceable sub main wiring and making good the disturbed surface complete, all as specified and directed.
Taking down unserviceable ceiling fan any size or any type and deposited to concerned AGE E/M store yard complete all as specified and directed.
Hanging only ceiling fan (M.D supply) in any model/size etc and making all connection using three core copper conductor flexible cable in size 0.75 sqmm including drawn through PVC flexible conduit pipe from ceiling rose to fan connector complete all as specified and directed.
Taking out old unserviceable earthing and material & labour for earthing with Galvanised Steel earth plate electrode 60cm x 60cm x 6.0 mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised Iron wire of size 4.0 mm as earthing lead (upto terminal point) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 40 mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh , RCC pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 3 of SSR 1991(Part-I) complete all as specified and as directed by Engineer-in-charge. Note : The rates for earth work, GI protection pipe, funnel, wire wesh, CI cover, etc shall be deemed to be including in quoted rates.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, heavy duty electric cable 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core complete all as specified and directed by Engineer in Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, heavy duty electric cable 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core complete all as specified and directed by Engineer in Charge.
Supply and fixing for GI protection pipe of 40 mm dia light grade for cable protection including all fittings laid in trenches or fixed on pole, complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation, shafts, man holes, laying of cable etc not exceeding 10 Square metre on plan and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in soil of any description, complete all as specified and as directed.
Removing excavated soil to a distance not exceeding 50 metre and deposited where directed at a level not exceeding 1.5m above the starting point, complete all as specified and as directed.
Material and labour for unwashed dry sand cushioning for cable protection ,filling in trenches/ducts, complete all as specified and as directed.
Material and labour for old size bricks sub class 'B' for cable protection laid along length of cable complete all as specified and as directed.
Supply, installation and testing of storage type heater (Geyser) of 25 Litres Capacity, vertical type to sustain high pressure upto 8 bars with fixing bolts / fastener, necessary PCC/cement work and making good the disturbed surfaces to match with existing surface giving electric and water connection and testing after installation to entire satisfaction of the Engineer-in-Charge complete with following specifications : - (a) 5 Star rated (Vertical type) Necessary BEE cerificate from OEM shall be produced by the contractor at the time of sample approval. (b) Metal Body. (c) Glass line coated tank (Ferro-glass technology) / Polymer coated. (d) Incoloy glass coated heating element. (e) Adjustable thermostat. (f) Temperature indicator dial/digital type. (g) Multiple Heating Option. (h) Multiple Functional Safety Valve. (j) Thermal Cutout Capillary Type. NOTE : - Warranty certificate to be produced by the contractor from OEM for the following components before processing the bill. (a) For product - 02 Years (b) For metal tank 07 years.
Supply and fixing for 15mm dia galvanised iron tubing medium grade with and including all fittings such as bends, elbows, tees, short pieces, union etc passing through walls for water connection to geyser including, making good the disturbed surface complete all as specified and as directed.
Supply and fixing for 20mm dia galvanised iron tubing medium grade with and including all fittings such as bends, elbows, tees, short pieces, union etc passing through walls for water connection to geyser including, making good the disturbed surface complete all as specified and as directed.
Supply and fixing temperature resistent SS braided pipe not less than 60 Cm long suitable for incoming and out going connections of Geyser with washer etc. c complete all as specified and directed by Engineer in Charge.
Supply and fixing Bib Tap cast copper alloy of 15 mm bore with crutch or butter fly handle ,screwed down ,screwed for pipe connection complete all as specified and directed by Engineer in Charge.
Supply and fixing stop/Gate valve cast copper alloy of 15 mm bore screwed down ,high pressure with crutch or butter fly handle screwded both ends for pipe or for unions and fixed complete all as specified and directed by Engineer in Charge.
Material and labour for point wiring using approved colour coding as per IS with stranded copper conductor 4 Sqmm (nominal area ),single core ,FRLSH PVC insulated and unshaethed stranded cable 1100 volts grade ISI-694 marked in and including heavy duty ,PVC concealed conduit ISI marked for one industrial type metal clad earth plug and socket out let with earth dolly including FRLS PVC Insulated unsheathed copper conductor 4 Sqmm nominal cross section area as earth continuity conductor upto common earth and connecting to common earth dolly complete and including cutting/chasing of wall complete all as specified and directed by Engr in Charge.
Supply and fixing sheet metal enclosure with two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and directed.
Supply and fixing MCB single pole, 240 Volts 6 to 32 Amps capacity, 'B' series including fixing in existing DB complete all as directed and specified.
Material and labour for Cutting and Screwing existing steel tubing in position without taking down for alterations or additions or lengthening screw on pipe to connector for suitable Bore complete all as directed and specified.
NOTE:- Amount of credit of Rs. 1,13,262.00 for retrieved materials is mentioned in Schedule of Credit Page No 24.00 & 25.00 of tender documents in pdf form which will be deducted offline while acceptance of tender.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.16 MB
Tenderdocuments65.pdf
Tender Documents • 2.21 MB
BOQ_837725.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .