Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1Accepted-Finance | ₹1 | 1 | Accepted-Finance Accepted as issued LOA |
| 2 | 1₹1Accepted-Finance 3RD FLOOR BESTECH BUSINESS TOWER SOHNA ROAD SECTOR 48 GURGAON HARYANA 122018 | GURUGRAM | HARYANA | 122018 | ₹1 | 1 | Accepted-Finance Accepted as issued LOA |
| 3 | 1₹1Accepted-Finance 1261 6TH FLOOR SOLITAIRE CORPORATE PARK BUILDING NUMBER 12 ANDHERI GHATKOPAR LINK ROAD ANDHERI EAST MUMBAI MAHARASHTRA 400093 | MUMBAI SUBURBAN | MAHARASHTRA | 400093 | ₹1 | 1 | Accepted-Finance Accepted as issued LOA |
| 4 | 1₹1Accepted-Finance 501 ARENA SPACE BEHIND MAJAS BUS DEPOT OFF J V LINK ROAD JOGESHWARI EAST MUMBAI MAHARASHTRA MAHARASHTRA 400060 | MUMBAI SUBURBAN | MAHARASHTRA | 400060 | ₹1 | 1 | Accepted-Finance Accepted as issued LOA |
| 5 | 1₹1Accepted-Finance NO 135 139 BILAKHIA HOUSE MUKTANAND MARG CHALA VAPI GUJARAT 396191 UDYAM GJ 25 0000710 | VALSAD | GUJARAT | 396191 | ₹1 | 1 | Accepted-Finance Accepted as issued LOA |
Tender Value
₹16.6 Cr
EMD Value
₹8 L
Closing Date
21 Sept 2023, 3:00 pmClosed
Faculty Incharge Procurement
Faculty Incharge Procurement, AIIMS Bilaspur, Himachal Pradesh 174001
RATE CONTRACT FOR SUPPLY OF CONSUMABLES FOR CTVS AND CARDIOLOGY DEPARTMENT
2023_AMSBL_762062_1
AIIMS/BLS/(G)/22-23/E-Tender/8
Open Tender
Consumables (Hospital / Lab)
30 days
AIIMS BILASPUR H.P
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Executive Director AIIMS Bilaspur
₹8 L
Yes
AIIMS BILASPUR H.P
6 Jul 2024
15 Jul 2023
22 Sept 2023
16 Jul 2023
21 Sept 2023
26 Jul 2023
16 Jul 2023 - 20 Jul 2023
21 Jul 2023
CONSUMABLES FOR CTVS & CARDIOLOGY DEPARTMENT
Adult femoral introducer sheath 5F Adult femoral introducer sheath with hemostatic valve in a kit containing puncture needle and 0.038” guide wire. 5F, Preferred make Terumo, Medtronics, Cordis
Adult femoral introducer sheath 10 F Adult femoral introducer sheath with hemostatic valve in a kit containing puncture needle and 0.038” guide wire. 10F, Preferred make Terumo, Medtronics, Cordis
Adult femoral introducer sheath 4F Adult femoral introducer sheath with hemostatic valve in a kit containing puncture needle and 0.038” guide wire. 4F, Preferred make Terumo, Medtronics, Cordis
Adult femoral introducer sheath 6F Adult femoral introducer sheath with hemostatic valve in a kit containing puncture needle and 0.038” guide wire. 6F, Preferred make Terumo, Medtronics, Cordis
Adult femoral introducer sheath 7F Adult femoral introducer sheath with hemostatic valve in a kit containing puncture needle and 0.038” guide wire. 7F, Preferred make Terumo, Medtronics, Cordis
Adult femoral introducer sheath 8F Adult femoral introducer sheath with hemostatic valve in a kit containing puncture needle and 0.038” guide wire. 8F, Preferred make Terumo, Medtronics, Cordis
Adult femoral introducer sheath 9F Adult femoral introducer sheath with hemostatic valve in a kit containing puncture needle and 0.038” guide wire. 9F, Preferred make Terumo, Medtronics, Cordis
AICD (Advanced) with DF4 lead AICD (Advanced) with DF4 lead *US FDA approved/certified AICD single chamber with all leads & accessories *Defibrillator with wireless telemetry without requirement of additional equipment *Should be able to deliver at least 35J energy *Should be DF4 lead compatibility *Ability to withhold shock in cases of RV noise *Should Have programmable polarity of leads *Should have capture management in RV *Should audibly alert the patient in case of RV Noise & Lead failure *Should monitor the fluid build-up status in a heart failure patient and audible alert the patient in case its critical *Should have ATP during charge in VF mode, with an option to make it ATP before charge. *Company must provide at least one programmer exclusively to the department of cardiology AIIMS Bilaspur. *Company must provide its trained technical person for each implantation and for follow up programming whenever required. *Company must quote only the latest model of devices commercially available. *Should have standard international warranty
AICD (MRI Conditional) with DF1 lead. AICD (MRI Conditional) with DF1 lead. *US FDA approved/certified single chamber AICD with all leads & accessories *Defibrillator with wireless telemetry without requirement of additional equipment *Should be 1.5T &/or 3T full body MRI conditional preferably without any restriction zone (Complete AICD unit including lead should be MRI conditional) *Programmable RV pace and sense vectors. *Algorithm for reduction of shock in cases of RV noise. *Algorithm for reduction of shock in cases over sensing of T-Wave*Programmable energy for each shock independently *Shock vector independently programmable for each shock * ATP during charging and ATP before charging. * Should allow morphology discrimination programmable. * Complete capture Management * Wireless Remote monitoring capable with full data transmission * Should monitor the fluid build-up status in a heart failure patient, and audible alert the patient in case it’s critical. *Company must provide at least one programmer exclusively to the department of cardiology AIIMS Bilaspur. *Company must provide its trained technical person for each implantation and for follow up programming whenever required. * Company must quote only the latest model of devices commercially available. * Should have standard international warranty
AICD (MRI Conditional) with DF4 lead. AICD (MRI Conditional) with DF4 lead. *US FDA approved/certified single chamber AICD with all leads & accessories *Defibrillator with wireless telemetry without requirement of additional equipment * Should be 1.5T &/or 3T full body MRI conditional preferably without any restriction zone (Complete AICD unit including lead should be MRI conditional) * Programmable RV pace and sense vectors. * Algorithm for reduction of shock in cases of RV noise. * Algorithm for reduction of shock in cases over sensing of T-Wave * Programmable energy for each shock independently * Shock vector independently programmable for each shock * ATP during charging and ATP before charging. * Should allow morphology discrimination programmable. *Complete capture Management * Wireless Remote monitoring capable with full data transmission * Should monitor the fluid build-up status in a heart failure patient, and audible alert the patient in case it’s critical. *Company must provide at least one programmer exclusively to the department of cardiology AIIMS Bilaspur. *Company must provide its trained technical person for each implantation and for follow up programming whenever required. *Company must quote only the latest model of devices commercially available. * Should have standard international warranty
AICD Dual Chamber with DF1 lead (MRI Conditional) AICD Dual Chamber with DF1 lead (MRI Conditional) *US FDA approved/certified dual chamber AICD with all leads & accessories * Defibrillator with wireless telemetry without requirement of additional equipment * Model should be DF1 lead compatible * Should be at least 1.5T & or 3T full Body MRI Conditional without any restriction zone (Complete AICD unit including lead should be MRI conditional) * Should be able to minimize RV pacing * Should be able to deliver at least 35J energy * Should have capture management in RA and RV * Ability to withhold shock in cases of RV noise * Ability to withhold shock in cases of T-Wave oversensing * Should have algorithms to manage and treat Atrial arrhythmias * Should have Rate Drop Response to counter Neurocardiogenic Syncope * Should audibly alert the patient in case of RV Noise & Lead failure. * Should monitor the fluid build-up status in a heart failure patient, and audible alert the patient in case its critical * Should have ATP during charge in VF mode, with an option to make it ATP before charge * Should have standard international warranty
AICD Dual Chamber with DF1 lead AICD Dual Chamber with DF1 lead *US FDA approved/certified dual chamber AICD with all leads & accessories * Must have shock reduction technology * All basic programmable parameters with preferably autosensing and auto capture/output management facilities. *Must monitor the lead integrity and notify in case of a suspected failure * RV lead must be 9F or less * Model must be DF1 lead compatible. * Must have all SVT discrimination in VF zone. * Must have morphological based SVT discrimination. * Must have remote patient management capability * Lead should be steroid eluting *Should have both active and passive fixation leads * Company must provide at least one programmer exclusively to the department of cardiology AIIMS Bilaspur. *Company must provide its trained technical person for each implantation and for follow up programming whenever required. *Company must quote only the latest model of devices commercially available. * Should have standard international warranty.
AICD Dual Chamber with DF4 lead (MRI Conditional) AICD Dual Chamber with DF4 lead (MRI Conditional) * US FDA approved/certified dual chamber AICD with all leads & accessories * Defibrillator with wireless telemetry without requirement of additional equipment * Model must be DF4 lead compatible * Should be at least 1.5T & or 3T full Body MRI Conditional without any restriction zone (Complete AICD unit including leads should be MRI conditional) * Should be able to minimize RV pacing * Should be able to deliver at least 35J energy * Should have capture management in RA and RV * Ability to withhold shock in cases of RV noise * Ability to withhold shock in cases of T-Wave oversensing * Should have algorithms to manage and treat Atrial arrhythmias * Should have Rate Drop Response to counter Neurocardiogenic Syncope * Should audibly alert the patient in case of RV Noise & Lead failure. * Should monitor the fluid build-up status in a heart failure patient, and audible alert the patient in case its critical * Should have ATP during charge in VF mode, with an option to make it ATP before charge * Should have standard international warranty
AICD Dual Chamber with DF4 lead AICD Dual Chamber with DF4 lead *US FDA approved/certified dual chamber AICD with all leads & accessories * Must have shock reduction technology * All basic programmable parameters with preferably autosensing and auto capture/output management facilities. *Must monitor the lead integrity and notify in case of a suspected failure * RV lead must be 9F or less * Model must be DF4 lead compatible. * Must have all SVT discrimination in VF zone. * Must have morphological based SVT discrimination. * Must have remote patient management capability * Lead should be steroid eluting * Should have both active and passive fixation leads * Company must provide at least one programmer exclusively to the department of cardiology AIIMS Bilaspur. * Company must provide its trained technical person for each implantation and for follow up programming whenever required. * Company must quote only the latest model of devices commercially available. * Should have standard international warranty.
AICD with DF1 lead AICD with DF1 lead *US FDA approved/certified AICD single chamber with all leads & accessories. *DF1 RV lead must be 9F or less *Model should be DF1 lead compatible. *All basic programmable parameters with preferably autosensing and auto capture/output management facilities. *Must have morphological based SVT discrimination. *Must monitor the lead integrity and notify in case of a suspected failure *Lead should be steroid eluting. *Should have both active and passive fixation leads. *Should have standard international warranty *Company must provide at least one programmer exclusively to the department of cardiology AIIMS Bilaspur. *Company must provide its trained technical person for each implantation and for follow up programming whenever required. *Company must quote only the latest model of devices commercially available.
AMPLATZ LEFT DIAGNOSTIC CATHETER AMPLATZ LEFT DIAGNOSTIC CATHETER 4F, 5F,6F all Curves. Should be FDA'/CE'/DCGI approved
AMPLATZ RIGHT DIAGNOSTIC CATHETER AMPLATZ RIGHT DIAGNOSTIC CATHETER 4F,5F,6F all Curves. Should be FDA'/CE'/DCGI approve
Amplatzer super stiff guide wire,long length Amplatzer super stiff guide wire,long length of 260 cm to 300 cm of 0.035" Size, Preferred make Boston, medtronics, Cordis, Terumo
Amplatzer super stiff guide wire,long length Amplatzer super stiff guide wire,long length of 260 cm to 300 cm of 0.038" Size, Preferred make Boston, medtronics, Cordis, Terumo
Angiographic Guide wire PTFE coated, 'J' tip, diameter 0.025'',.Extra- Length Angiographic Guide wire PTFE coated, 'J' tip, diameter 0.025'',.Extra- Length (250-260 cm), Preferred make Terumo, Medtronics, Cordis
Angiographic Guide wire PTFE coated, 'J' tip, diameter 0.032'',.Extra- Length Angiographic Guide wire PTFE coated, 'J' tip, diameter 0.032'',.Extra- Length (250-260 cm), Preferred make Terumo, Medtronics, Cordis
Angiographic Guide wire PTFE coated, 'J' tip, diameter 0.035'',.Extra- Length Angiographic Guide wire PTFE coated, 'J' tip, diameter 0.035'',.Extra- Length (250-260 cm), Preferred make Terumo, Medtronics, Cordis
Angiographic Guide wire PTFE coated, 'J' tip, diameter 0.038'',.Extra- Length Angiographic Guide wire PTFE coated, 'J' tip, diameter 0.038'',.Extra- Length (250-260 cm), Preferred make Terumo, Medtronics, Cordis
Angiographic Guide wire, PTFE coated, 'J' tip, diameter 0.021'',.Extra- Length Angiographic Guide wire, PTFE coated, 'J' tip, diameter 0.021'',.Extra- Length (250-260 cm), Preferred make Terumo, Medtronics, Cordis
Angiographic Guide Wire; PTFE coated; Straight tip; diameter 0.038" ; Regular length Angiographic Guide Wire; PTFE coated; Straight tip; diameter 0.038" ; Length 120-150 (Regular length), Preferred make Terumo, Medtronics, Cordis
Angiographic Guide Wire; PTFE coated; ‘J’ tip ; diameter 0.038" ; Regular length Angiographic Guide Wire; PTFE coated; ‘J’ tip ; diameter 0.038" ; Length 120-150 (Regular length), Preferred make Terumo, Medtronics, Cordis
Angiographic Guide Wire; PTFE coated; ‘J’ tip ; diameter 0.032" ; Regular length Angiographic Guide Wire; PTFE coated; ‘J’ tip ; diameter 0.032" ; Length 120-150 (Regular length), Preferred make Terumo, Medtronics, Cordis
Angiographic Guide Wire; PTFE coated; ‘J’ tip; diameter 0.035" ; Regular length Angiographic Guide Wire; PTFE coated; ‘J’ tip; diameter 0.035" ; Length 120-150 (Regular length), Preferred make Terumo, Medtronics, Cordis
Angiographic Guide Wire; PTFE coated; ‘J’ tip; diameter 0.021” ; Regular length Angiographic Guide Wire; PTFE coated; ‘J’ tip; diameter 0.021” ; Length 120-150 (Regular length), Preferred make Terumo, Medtronics, Cordis
Angiographic Guide Wire; PTFE coated; ‘J’ tip; diameter 0.025" ; Regular length Angiographic Guide Wire; PTFE coated; ‘J’ tip; diameter 0.025" ; Length 120-150 (Regular length), Preferred make Terumo, Medtronics, Cordis
Angiographic Guide Wire; PTFE coated; Straight tip; diameter 0.021” ; Regular length Angiographic Guide Wire; PTFE coated; Straight tip; diameter 0.021” ; Length 120-150 (Regular length), Preferred make Terumo, Medtronics, Cordis
Angiographic Guide Wire; PTFE coated; Straight tip; diameter 0.025" ; Regular length Angiographic Guide Wire; PTFE coated; Straight tip; diameter 0.025" ; Length 120-150 (Regular length), Preferred make Terumo, Medtronics, Cordis
Angiographic Guide Wire; PTFE coated; Straight tip; diameter 0.032" ; Regular length Angiographic Guide Wire; PTFE coated; Straight tip; diameter 0.032" ; Length 120-150 (Regular length), Preferred make Terumo, Medtronics, Cordis
Angiographic Guide Wire; PTFE coated; Straight tip; diameter 0.035" ; Regular length Angiographic Guide Wire; PTFE coated; Straight tip; diameter 0.035" ; Length 120-150 (Regular length), Preferred make Terumo, Medtronics, Cordis
Balloon tipped thermodilution triple lumen catheter (Swan Ganz type) Balloon tipped thermodilution triple lumen catheter (Swan Ganz type), 6F, 7F, US FDA/CE Approved/certified
Balloon-Flow Assisted Bipolar Temporary Pacing Electrode Catheter Balloon-Flow Assisted Bipolar Temporary Pacing Electrode Catheter: Must have marking on catheter, Must be NBIHTM standard, Non-Heparin Coated, Sizes-5 French, With depth marker
Cannula fixator, dynaplast type Cannula fixator, dynaplast type
Carotid Sheaths (90cm) All sizes Carotid Sheaths (90cm) All sizes
Carotid stents –Non tapered cylinder 0.014” wire rapid exchange (Self-expanding) Carotid stents –Non tapered cylinder 0.014” wire rapid exchange (Self-expanding), all sizes
Carotid stents- Tapered cylinder 0.014” wire rapid exchange (self expanding) Carotid stents- Tapered cylinder 0.014” wire rapid exchange (self expanding), all sizes
CE approved/certified or DCGI approved/certified IVC Filter a) Temporary/Retrieval b) Permanent (MRI & Non MRI compatible) CE approved/certified & DCGI approved IVC Filter a) Temporary/Retrieval b) Permanent (MRI & Non MRI compatible)
CE approved/certified PTCA pre-dilatation semi-compliant over the wire balloon CE approved/certified PTCA pre-dilatation semi-compliant over the wire balloon with short balloon taper, low entry profile (≤0.016”). Diameter –1.2/1.25, 1.5, 2.0, 2.5, 3.0 mm or more Length – minimum 6-8 mm to 20mm.
Closure Device for vascular access site (Angioseal type) Vascular Closure Device for vascular access site (non suture mediated)
Closure Device for vascular access site (Proglide type) Vascular Closure Device for vascular access site (suture mediated)
Cobalt chromium base Everolimus coated drug eluting coronary stent European CE approved/certified Cobalt chromium base Everolimus coated drug eluting coronary stent (All sizes & Diameters)
Cobalt chromium base Everolimus coated drug eluting coronary stent US FDA approved/Certified Cobalt chromium base Everolimus coated drug eluting coronary stent (All sizes & Diameters)
Cobalt chromium base Sirolimus coated drug eluting coronary stent US FDA approved/certified Cobalt chromium base Sirolimus coated drug eluting coronary stent (All sizes & Diameters)
Cobalt chromium base Sirolimus coated drug eluting coronary stent European CE approved/certified Cobalt chromium base Sirolimus coated drug eluting coronary stent (All sizes & Diameters)
Cobalt chromium base Zotarolimus coated drug eluting coronary stent European CE approved/certified Cobalt chromium base Zotarolimus coated drug eluting coronary stent (All sizes & Diameters)
Cobalt chromium base Zotarolimus coated drug eluting coronary stent US FDA approved/certified Cobalt chromium base Zotarolimus coated drug eluting coronary stent (All sizes & Diameters)
Contralateral Sheath (All Sizes) Contralateral Sheath (All Sizes)
Contrast injecting luer lock controlled syringe 5 cc without finger grip. Sterile Plastic Contrast injecting luer lock controlled syringe 5 cc without finger grip.
Coronary microcatheter US FDA Approved/certified Coronary microcatheter with distal diameter of 1.8 Fr or less, proximal diameter 2.6F, PTFE coated inner layer, and distal hydrophilic coating at the outer layer, flexible tip with outer and inner taper with marker at distal tip for enhanced distal visibility to cross difficult lesions. a) 130-135 cm long b) 150-160 cm long
Coronary microcatheter, CE approved/Certified or DCGI approved/certified CE approved/Certified & DCGI approved Coronary microcatheter with distal diameter of 1.8 Fr or less, proximal diameter 2.6F, PTFE coated inner layer, and distal hydrophilic coating at the outer layer, flexible tip with outer and inner taper with marker at distal tip for enhanced distal visibility to cross difficult lesions. a) 130-135 cm long b) 150-160 cm long
COURNAND CATHETER 5F woven dacron. Should be FDA'/CE'/DCGI approved COURNAND CATHETER 5F woven dacron. Should be FDA'/CE'/DCGI approved
COURNAND CATHETER 6F woven dacron. Should be FDA'/CE'/DCGI approved COURNAND CATHETER 6F woven dacron. Should be FDA'/CE'/DCGI approved
Covered stent for coronary use (balloon expandable) All sizes Covered stent for coronary use (balloon expandable) All sizes
Covered Stent for peripheral (Self expanding)All sizes Covered Stent for peripheral (Self expanding)All sizes
Covered Stent for peripheral use (balloon expandable) All sizes Covered Stent for peripheral use (balloon expandable) All sizes
CP stent for coarctation of aorta (covered) with delivery system CP stent for coarctation of aorta (covered) with delivery system
CP stent for coarctation of aorta (Non- covered) with delivery system CP stent for coarctation of aorta (Non- covered) with delivery system
CRT-D CRT-D *US FDA approved/certified biventricular pacemaker with atrial, DF1 RV and Bipolar LV leads and all accessories *Wireless Telemetry *Should be able to deliver 35J energy * Should have capture management in LV * Ability to withhold shock in cases of RV noise * Ability to withhold shock in cases of T-Wave oversensing * Should have algorithms to manage and treat Atrial arrhythmias * Should have Rate Drop Response to counter Neurocardiogenic Syncope* Should audibly alert the patient in case of RV Noise & Lead failure. * Should have ATP during charge in VF mode, with an option to make it ATP before charge * Should have standard international warranty
CRT-P (Advanced) CRT-P (Advanced) * US FDA approved/certified biventricular pacemaker with atrial, RV and Quadripolar LV leads and all accessories. * Must have multipoint pacing options. *Should have Ventricular Sense Response * Should have algorithm in order to ensure 100% CRT Therapy * Should have capture management in RA, RV and LV * Should monitor the fluid build-up status in a heart failure patient, and audible alert the patient in case it’s critical. * Must have separate programmable RV, LV lead amplitude, pulse width and VV delay. * The size of RA, RV & LV leads should be 7F or less * The leads should be steroid eluting and should be bipolar and unipolar configuration * Should have both active and passive fixation RA & RV endocardial leads. * Should have facility for active fixation of LV lead in CS with both screwing and/or deployable lobes with anchor mechanism. * Should have facility for epicardial LV lead implantation. * Monitor the integrity of lead and switch polarity in case of issue * Must have remote patient management capability. * Should have Standard International Warranty
CRT-P (Advanced, MRI Conditional) CRT-P (Advanced), MRI conditional * US FDA approved/certified biventricular pacemaker with atrial, RV and Quadripolar LV leads and all accessories. * Should be 1.5T and/or 3T Full Body MRI Conditional (Complete unit including leads should be MRI conditional). * Must have multipoint pacing options. *Should have Ventricular Sense Response * Should have algorithm in order to ensure 100% CRT Therapy * Should have capture management in RA, RV and LV * Should monitor the fluid build-up status in a heart failure patient, and audible alert the patient in case it’s critical. * Must have separate programmable RV, LV lead amplitude, pulse width and VV delay. * The size of RA, RV & LV leads should be 7F or less * The leads should be steroid eluting and should be bipolar and unipolar configuration * Should have both active and passive fixation RA & RV endocardial leads. * Should have facility for active fixation of LV lead in CS with both screwing and/or deployable lobes with anchor mechanism. * Should have facility for epicardial LV lead implantation. * Monitor the integrity of lead and switch polarity in case of issue * Must have remote patient management capability. * Should have Standard International Warranty
CRT-P (MRI Conditional) CRT-P (MRI Conditional) * US FDA approved/certified biventricular pacemaker with atrial, RV and LV leads and all accessories. * Should be 1.5T and/or 3T Full Body MRI Conditional (Complete unit including leads should be MRI conditional). * Must have separate programmable RV, LV lead amplitude, pulse width and VV delay. * The size of RA, RV & LV leads should be 7F or less * The leads should be steroid eluting and should be bipolar and unipolar configuration * Should have both active and passive fixation RA & RV endocardial leads. * Should have facility for active fixation of LV lead in CS with both screwing and/or deployable lobes with anchor mechanism. * Should have facility for epicardial LV lead implantation. * Monitor the integrity of lead and switch polarity in case of issue * Must have RA, RV and LV Capture Management. * Should have Standard International Warranty
CRT-P CRT-P * US FDA approved/certified biventricular pacemaker with atrial, RV and LV leads and all accessories * Must have separate programmable RV, LV lead amplitude, pulse width and VV delay. * The size of RA, RV & LV leads should be 7F or less * The leads should be steroid eluting and should be bipolar and unipolar configuration * Should have both active and passive fixation RA & RV endocardial leads. * Should have facility for active fixation of LV lead in CS with both screwing and/or deployable lobes with anchor mechanism. * Should have facility for epicardial LV lead implantation. * Monitor the integrity of lead and switch polarity in case of issue * Must have RA, RV and LV Capture Management. * Should have Standard International Warranty
DCGI approved Cobalt chromium base Everolimus coated drug eluting coronary stent DCGI approved Cobalt chromium base Everolimus coated drug eluting coronary stent (All sizes & Diameters)
DCGI approved Cobalt chromium base Sirolimus coated drug eluting coronary stent DCGI approved Cobalt chromium base Sirolimus coated drug eluting coronary stent (All sizes & Diameters)
DCGI approved Cobalt chromium base Zotarolimus coated drug eluting coronary stent DCGI approved Cobalt chromium base Zotarolimus coated drug eluting coronary stent (All sizes & Diameters)
DCGI approved Platinum chromium base Everolimus coated drug eluting coronary stent DCGI approved Platinum chromium base Everolimus coated drug eluting coronary stent (All sizes & Diameters)
DCGI approved Platinum chromium base Sirolimus coated drug eluting coronary stent DCGI approved Platinum chromium base Sirolimus coated drug eluting coronary stent (All sizes & Diameters)
DCGI approved Platinum chromium base Zotarolimus coated drug eluting coronary stent DCGI approved Platinum chromium base Zotarolimus coated drug eluting coronary stent (All sizes & Diameters)
DCGI approved PTCA pre-dilatation semi-compliant over the wire balloon DCGI approved PTCA pre-dilatation semi-compliant over the wire balloon with short balloon taper, low entry profile (≤0.016”). Diameter –1.2/1.25, 1.5, 2.0, 2.5, 3.0 mm or more Length – minimum 6-8 mm to 20mm.
DCGI approved Stainless steel base Everolimus coated drug eluting coronary stent DCGI approved Stainless steel base Everolimus coated drug eluting coronary stent (All sizes & Diameters)
DCGI approved Stainless steel base Sirolimus coated drug eluting coronary stent DCGI approved Stainless steel base Sirolimus coated drug eluting coronary stent (All sizes & Diameters)
DCGI approved Stainless steel base Zotarolimus coated drug eluting coronary stent DCGI approved Stainless steel base Zotarolimus coated drug eluting coronary stent (All sizes & Diameters)
DDD pacemaker with International standard warranty DDD pacemaker with International standard warranty *US FDA approved/certified pacemaker with lead & accessories *All pacing modes and basic pacing programmable parameters including hysteresis with preferably autosensing and autocapture/output management facilities. * Must have Ventricular and Atrial Capture Management. *Must minimize ventricular pacing by optimizing AV delay automatically. * Monitor the integrity of lead and switch polarity in case of issue. *The Size of lead should be 7F or less. *The Lead must be steroid eluting and should be both bipolar and unipolar configuration. *Must have both active and passive fixation endocardial leads available. *Company must provide at least one programmer exclusively to the department of cardiology AIIMS Bilaspur. *Company must provide its trained technical person for each implantation and for follow up programming whenever required. *Company must quote only the latest model of devices commercially available. *Model with International standard warranty (at least 7 years or more).
DDDR (AT/AF management,1.5T MRI Conditional) with International standard warranty DDDR (AT/AF management,1.5T MRI Conditional) with International standard warranty *US FDA approved/certified MRI conditional pacemaker with lead & accessories (Complete pacemaker unit including generator & lead must be MRI conditional) *Evaluate threshold of atrial & ventricular lead to adjust atrial & ventricular output on daily basis. *Automatically adjust sensitivity to maintain adequate sensing margins. *Dual zone rate response, one for normal response and other for response during exercise. *Mode based Physiological Pacing Algorithm to promote intrinsic conduction. *Atrial intervention for AF Prevention by constantly overdriving Atrium. *Rate drop response for syncope management with ability to detect both drop rate and drop size. *ATP therapies to terminate high rate atrial tachyarrhythmia episodes. *The Size of lead should be 7F or less. *The Lead must be steroid eluting and should be both bipolar and unipolar configuration. *Must have both active and passive fixation endocardial leads available. *Must have rate response which allows rate profile optimization. *Company must provide at least one programmer exclusively to the department of cardiology AIIMS Bilaspur. *Company must provide its trained technical person for each implantation and for follow up programming whenever required. *Should allow full body at 1.5T MRI scan without any restriction zone with International standard warranty (at least 7 years or more)
DDDR (AT/AF management,3T MRI Conditional) with International lifetime warranty DDDR (AT/AF management,3T MRI Conditional) with International lifetime warranty *US FDA approved/certified MRI conditional pacemaker with lead & accessories (Complete pacemaker unit including generator & lead must be MRI conditional) *Evaluate threshold of atrial & ventricular lead to adjust atrial & ventricular output on daily basis. *Automatically adjust sensitivity to maintain adequate sensing margins. *Dual zone rate response, one for normal response and other for response during exercise. *Mode based Physiological Pacing Algorithm to promote intrinsic conduction. *Atrial intervention for AF Prevention by constantly overdriving Atrium. *Rate drop response for syncope management with ability to detect both drop rate and drop size. *ATP therapies to terminate high rate atrial tachyarrhythmia episodes. *The Size of lead should be 7F or less. *The Lead must be steroid eluting and should be both bipolar and unipolar configuration. *Must have both active and passive fixation endocardial leads available. *Must have rate response which allows rate profile optimization. *Company must provide at least one programmer exclusively to the department of cardiology AIIMS Bilaspur. *Company must provide its trained technical person for each implantation and for follow up programming whenever required. *Should allow full body at 3T MRI scan without any restriction zone with International lifetime warranty
DDDR (AT/AF management,3T MRI Conditional) with International standard warranty DDDR (AT/AF management,3T MRI Conditional) with International standard warranty *US FDA approved/certified MRI conditional pacemaker with lead & accessories (Complete pacemaker unit including generator & lead must be MRI conditional) *Evaluate threshold of atrial & ventricular lead to adjust atrial & ventricular output on daily basis. *Automatically adjust sensitivity to maintain adequate sensing margins. *Dual zone rate response, one for normal response and other for response during exercise. *Mode based Physiological Pacing Algorithm to promote intrinsic conduction. *Atrial intervention for AF Prevention by constantly overdriving Atrium. *Rate drop response for syncope management with ability to detect both drop rate and drop size. *ATP therapies to terminate high rate atrial tachyarrhythmia episodes. *The Size of lead should be 7F or less. *The Lead must be steroid eluting and should be both bipolar and unipolar configuration. *Must have both active and passive fixation endocardial leads available. *Must have rate response which allows rate profile optimization. *Company must provide at least one programmer exclusively to the department of cardiology AIIMS Bilaspur. *Company must provide its trained technical person for each implantation and for follow up programming whenever required. *Should allow full body at 3T MRI scan without any restriction zone with International standard warranty (at least 7 years or more)"
DDDR pacemaker with International lifetime warranty DDDR pacemaker with International lifetime warranty *US FDA approved/certified pacemaker with lead & accessories *All pacing modes and basic pacing programmable parameters including hysteresis with preferably autosensing and autocapture/output management facilities. * Must have Ventricular and Atrial Capture Management. *Must minimize ventricular pacing by optimizing AV delay automatically. * Monitor the integrity of lead and switch polarity in case of issue. *The Size of lead should be 7F or less. *The Lead must be steroid eluting and should be both bipolar and unipolar configuration. *Must have both active and passive fixation endocardial leads available. *Company must provide at least one programmer exclusively to the department of cardiology AIIMS Bilaspur. *Company must provide its trained technical person for each implantation and for follow up programming whenever required. *Company must quote only the latest model of devices commercially available. *Model with International lifetime warranty
DDDR pacemaker with International lifetime warranty, 1.5 T Conditional DDDR pacemaker with International lifetime warranty, 1.5 T Conditional *US FDA approved/certified pacemaker with lead & accessories *All pacing modes and basic pacing programmable parameters including hysteresis with preferably autosensing and autocapture/output management facilities. * Must have Ventricular and Atrial Capture Management. *Must minimize ventricular pacing by optimizing AV delay automatically. * Monitor the integrity of lead and switch polarity in case of issue. *The Size of lead should be 7F or less. *The Lead must be steroid eluting and should be both bipolar and unipolar configuration. *Must have both active and passive fixation endocardial leads available. *Company must provide at least one programmer exclusively to the department of cardiology AIIMS Bilaspur. *Company must provide its trained technical person for each implantation and for follow up programming whenever required. *Company must quote only the latest model of devices commercially available. *Should allow 1.5T full body MRI scan without any restriction zone, with International lifetime warranty
DDDR pacemaker with International lifetime warranty, 3 T MRI Conditional DDDR pacemaker with International lifetime warranty, 3 T MRI Conditional *US FDA approved/certified pacemaker with lead & accessories *All pacing modes and basic pacing programmable parameters including hysteresis with preferably autosensing and autocapture/output management facilities. * Must have Ventricular and Atrial Capture Management. *Must minimize ventricular pacing by optimizing AV delay automatically. * Monitor the integrity of lead and switch polarity in case of issue. *The Size of lead should be 7F or less. *The Lead must be steroid eluting and should be both bipolar and unipolar configuration. *Must have both active and passive fixation endocardial leads available. *Company must provide at least one programmer exclusively to the department of cardiology AIIMS Bilaspur. *Company must provide its trained technical person for each implantation and for follow up programming whenever required. *Company must quote only the latest model of devices commercially available. *Should allow 3T full body MRI scan without any restriction zone, with International lifetime warranty
DDDR pacemaker with International standard warranty DDDR pacemaker with International standard warranty *US FDA approved/certified pacemaker with lead & accessories *All pacing modes and basic pacing programmable parameters including hysteresis with preferably autosensing and autocapture/output management facilities. * Must have Ventricular and Atrial Capture Management. *Must minimize ventricular pacing by optimizing AV delay automatically. * Monitor the integrity of lead and switch polarity in case of issue. *The Size of lead should be 7F or less. *The Lead must be steroid eluting and should be both bipolar and unipolar configuration. *Must have both active and passive fixation endocardial leads available. *Company must provide at least one programmer exclusively to the department of cardiology AIIMS Bilaspur. *Company must provide its trained technical person for each implantation and for follow up programming whenever required. *Company must quote only the latest model of devices commercially available. *Model with International standard warranty (at least 7 years or more)."
DDDR pacemaker with International standard warranty, 1.5 T MRI Conditional DDDR pacemaker with International standard warranty, 1.5 T MRI Conditional *US FDA approved/certified pacemaker with lead & accessories *All pacing modes and basic pacing programmable parameters including hysteresis with preferably autosensing and autocapture/output management facilities. * Must have Ventricular and Atrial Capture Management. *Must minimize ventricular pacing by optimizing AV delay automatically. * Monitor the integrity of lead and switch polarity in case of issue. *The Size of lead should be 7F or less. *The Lead must be steroid eluting and should be both bipolar and unipolar configuration. *Must have both active and passive fixation endocardial leads available. *Company must provide at least one programmer exclusively to the department of cardiology AIIMS Bilaspur. *Company must provide its trained technical person for each implantation and for follow up programming whenever required. *Company must quote only the latest model of devices commercially available. *Should allow 1.5T full body MRI scan without any restriction zone, with International standard warranty (at least 7 years or more).
DDDR pacemaker with International standard warranty, 3 T MRI Conditional DDDR pacemaker with International standard warranty, 3 T MRI Conditional *US FDA approved/certified pacemaker with lead & accessories *All pacing modes and basic pacing programmable parameters including hysteresis with preferably autosensing and autocapture/output management facilities. * Must have Ventricular and Atrial Capture Management. *Must minimize ventricular pacing by optimizing AV delay automatically. * Monitor the integrity of lead and switch polarity in case of issue. *The Size of lead should be 7F or less. *The Lead must be steroid eluting and should be both bipolar and unipolar configuration. *Must have both active and passive fixation endocardial leads available. *Company must provide at least one programmer exclusively to the department of cardiology AIIMS Bilaspur. *Company must provide its trained technical person for each implantation and for follow up programming whenever required. *Company must quote only the latest model of devices commercially available. *Should allow 3T full body MRI scan without any restriction zone, with International standard warranty (at least 7 years or more)."
DOC Extension wire DOC Extension wire compatible with 0.014 inch ptca guidewire
Embolic Protection device (Peripheral) A.Proximal protection B.Filter type C.Balloon occlusion type Embolic Protection device (Peripheral) A.Proximal protection B.Filter type C.Balloon occlusion type
Exchange length (260cm and above) 0.018'' peripheral intervention guide wire Exchange length (260cm and above) 0.018'' peripheral intervention guide wire. Should be FDA'/CE'/DCGI approved
EXTRALONG ( more than 150 cm) pigtail catheters for illiac angiography from radial EXTRALONG ( more than 150 cm) pigtail catheters for illiac angiography from radial . Should be FDA'/CE'/DCGI approved
EXTRALONG ( more than 150 cm) pigtail catheters for illiac angiography from radial EXTRALONG ( more than 150 cm) pigtail catheters for illiac angiography from radial . Should be FDA'/CE'/DCGI approved
Flexible delivery sheaths with steerable and defelctable introducer systems ( 60 cm and above long) Flexible delivery sheaths with steerable and defelctable introducer systems ( 60 cm and above long). Should be CE'/ DCGI approved
Foreign body retrieval snares (Coronary) Foreign body retrieval snares (Coronay), All sizes A.Amplantz type,gooseneck. B.Basket Type C.Cook-angled type D.Wire loop type
Foreign body retrieval snares (Non-Coronary) Foreign body retrieval snares (Non-Coronay), All sizes A.Amplantztype,gooseneck B.Basket Type C.Cook-angled type D.Wire loop type
Guide catheter extension system 6F,7F compatible, rapid exchange with 145-150 cm working length, tip radiopaque marker.
High pressure Injector line to withstand pressure up to 1200 psi High pressure Injector line to withstand pressure up to 1200 psi, 120-150 cm length with luer lock male port and rotator
High pressure Injector line to withstand pressure up to 1200 psi High pressure Injector line to withstand pressure up to 1200 psi, 60-75 cm length with luer lock male port and rotator
Hydrophilic Guidewire 150 cm- Angled tip, 0.018" Hydrophilic Guidewire 150 cm- Angled tip, 0.018", (Terumo Type)
Hydrophilic Guidewire 150 cm- Angled tip, 0.025" Hydrophilic Guidewire 150 cm- Angled tip, 0.025", (Terumo Type)
Hydrophilic Guidewire 150 cm- Angled tip, 0.032" Hydrophilic Guidewire 150 cm- Angled tip, 0.032", (Terumo Type)
Hydrophilic Guidewire 150 cm- Angled tip, 0.035" Hydrophilic Guidewire 150 cm- Angled tip, 0.035", (Terumo Type)
Hydrophilic Guidewire 150 cm- Angled tip, 0.038" Hydrophilic Guidewire 150 cm- Angled tip, 0.038", (Terumo Type)
Hydrophilic Guidewire 150 cm- Straight tip, 0.018" Hydrophilic Guidewire 150 cm- Straight tip, 0.018", (Terumo Type)
Hydrophilic Guidewire 150 cm- Straight tip, 0.025" Hydrophilic Guidewire 150 cm- Straight tip, 0.025", (Terumo Type)
Hydrophilic Guidewire 150 cm- Straight tip, 0.032" Hydrophilic Guidewire 150 cm- Straight tip, 0.032", (Terumo Type)
Hydrophilic Guidewire 150 cm- Straight tip, 0.035" Hydrophilic Guidewire 150 cm- Straight tip, 0.035", (Terumo Type)
Hydrophilic Guidewire 150 cm- Straight tip, 0.038" Hydrophilic Guidewire 150 cm- Straight tip, 0.038", (Terumo Type)
Hydrophilic Guidewire 260 cm- Angled tip, 0.018" Hydrophilic Guidewire 260 cm- Angled tip, 0.018", (Terumo Type)
Hydrophilic Guidewire 260 cm- Angled tip, 0.025" Hydrophilic Guidewire 260 cm- Angled tip, 0.025", (Terumo Type)
Hydrophilic Guidewire 260 cm- Angled tip, 0.032" Hydrophilic Guidewire 260 cm- Angled tip, 0.032", (Terumo Type)
Hydrophilic Guidewire 260 cm- Angled tip, 0.035" Hydrophilic Guidewire 260 cm- Angled tip, 0.035", (Terumo Type)
Hydrophilic Guidewire 260 cm- Angled tip, 0.038" Hydrophilic Guidewire 260 cm- Angled tip, 0.038", (Terumo Type)
Hydrophilic Guidewire 260 cm cm- Straight tip, 0.025" Hydrophilic Guidewire 260 cm cm- Straight tip, 0.025", (Terumo Type)
Hydrophilic Guidewire 260 cm- Straight tip, 0.018" Hydrophilic Guidewire 260 cm- Straight tip, 0.018", (Terumo Type)
Hydrophilic Guidewire 260 cm- Straight tip, 0.032" Hydrophilic Guidewire 260 cm- Straight tip, 0.032", (Terumo Type)
Hydrophilic Guidewire 260 cm- Straight tip, 0.035" Hydrophilic Guidewire 260 cm- Straight tip, 0.035", (Terumo Type)
Hydrophilic Guidewire 260 cm- Straight tip, 0.038" Hydrophilic Guidewire 260 cm- Straight tip, 0.038", (Terumo Type)
Hydrophilic Stiff Guidewire 150 cm- Angled tip, 0.035" Hydrophilic Stiff Guidewire 150 cm- Angled tip, 0.035", (Terumo Type)
Hydrophilic Stiff Guidewire 150 cm- Angled tip, 0.038" Hydrophilic Stiff Guidewire 150 cm- Angled tip, 0.038", (Terumo Type)
Hydrophilic Stiff Guidewire 260 cm- Angled tip, 0.035" Hydrophilic Stiff Guidewire 260 cm- Angled tip, 0.035", (Terumo Type)
Hydrophilic Stiff Guidewire 260 cm- Angled tip, 0.038" Hydrophilic Stiff Guidewire 260 cm- Angled tip, 0.038", (Terumo Type)
Inflation device with manometer upto 15 atmosphere, 60 cc Inflation device with manometer upto 15 atmosphere, 60 cc (easy to operate with luminescent dial)
Inflation device with manometer upto 30 atmosphere, 20 cc Inflation device with manometer upto 30 atmosphere, 20 cc (easy to operate with luminescent dial)
Inflation device with manometer upto 45 atmosphere, 25 or 30 cc Inflation device with manometer upto 45 atmosphere, 25 or 30 cc (easy to operate with luminescent dial)
Inflation device with manometer upto 55 atmosphere Inflation device with manometer upto 55 atmosphere (easy to operate with luminescent dial)
INTERNAL MAMMARY ARTERY DIAGNOSTIC CATHETER INTERNAL MAMMARY ARTERY CATHETER 4F, 5F,6F all Curves. Should be FDA'/CE'/DCGI approve
Iso-osmolar non-ionic 320,IODIXANOL (20ml, 50ml & 100ml) Iso-osmolar non-ionic 320,IODIXANOL (20ml, 50ml & 100ml)
Iso-osmolar non-ionic 350,IOHEXOL INJECTION (20, 50ml & 100ml) Iso-osmolar non-ionic 350,IOHEXOL INJECTION (20, 50ml & 100ml)
IVC Filter a) Temporary/Retrieval b) Permanent (MRI & Non MRI compatible) US FDA OR CE approved/certified IVC Filter a) Temporary/Retrieval b) Permanent (MRI & Non MRI compatible)
JUDKINS LEFT DIAGNOSTIC CATHETER JUDKINS LEFT DIAGNOSTIC CATHETER 4F,5F,6F all Curves. Should be FDA'/CE'/DCGI approved
JUDKINS RIGHT DIAGNOSTIC CATHETER JUDKINS RIGHT DIAGNOSTIC CATHETER 4F,5F,6F all Curves. Should be FDA'/CE'/DCGI approved
LEFT CORONARY BY PASS DIAGNOSTIC CATHETER LEFT CORONARY BY PASS DIAGNOSTIC CATHETER 4F,5F,6F all Curves. Should be FDA'/CE'/DCGI approved
Lignocaine spray 10% Lignocaine spray 10%, 50 ml with spraying nozzle
Lunderquist type high support exchange length 0.035'' (260cm and above) short and long tip guide wire Lunderquist type high support exchange length 0.035'' (260cm and above) short and long tip guide wire . Should be FDA'/CE'/DCGI approved
Manifold - Three ports Manifold - Three ports with knobs to turn “Right” when open.
Manifold - Two ports Manifold - Two ports with knobs to turn “Right” when open.
MARKER PIGTAIL CATHETER 5F. MARKER PIGTAIL CATHETER 5F. Should be FDA'/ CE'/ DCGI approved
MARKER PIGTAIL CATHETER 6F. MARKER PIGTAIL CATHETER 6F. Should be FDA'/ CE'/ DCGI approved
Mitral Valvuloplasty Balloon (Non-Inoue) Mitral Valvuloplasty Balloon (Non-Inoue), All Sizes with accessories, should be FDA/CE/DCGI approved
Mullins sheath (all sizes) Mullins sheath (all sizes)
MULTIPURPOSE CATHETER A1,A2,B1,B2. MULTIPURPOSE CATHETER A1,A2,B1,B2. Should be FDA'/ CE'/ DCGI approved
Pacemaker DDDR (AT/AF management,1.5T MRI Conditional) with International lifetime warranty DDDR (AT/AF management,1.5T MRI Conditional) with International lifetime warranty *US FDA approved/certified MRI conditional pacemaker with lead & accessories (Complete pacemaker unit including generator & lead must be MRI conditional) *Evaluate threshold of atrial & ventricular lead to adjust atrial & ventricular output on daily basis. *Automatically adjust sensitivity to maintain adequate sensing margins. *Dual zone rate response, one for normal response and other for response during exercise. *Mode based Physiological Pacing Algorithm to promote intrinsic conduction. *Atrial intervention for AF Prevention by constantly overdriving Atrium. *Rate drop response for syncope management with ability to detect both drop rate and drop size. *ATP therapies to terminate high rate atrial tachyarrhythmia episodes. *The Size of lead should be 7F or less. *The Lead must be steroid eluting and should be both bipolar and unipolar configuration. *Must have both active and passive fixation endocardial leads available. *Must have rate response which allows rate profile optimization. *Company must provide at least one programmer exclusively to the department of cardiology AIIMS Bilaspur. *Company must provide its trained technical person for each implantation and for follow up programming whenever required. *Should allow full body at 1.5T MRI scan without any restriction zone with International lifetime warranty
Pacemaker Lead Extraction Device. a. Lead Locking Device. b. Mechanical rotating Dilator c. Manual Dilator. d. Bridge Balloon. Pacemaker Lead Extraction Device. Should be FDA/CE/DCGI approved a. Lead Locking Device. b. Mechanical rotating Dilator c. Manual Dilator. d. Bridge Balloon.
Paclitaxel coated coronary drug eluting balloon European CE certified/DCGI approved Paclitaxel coated coronary drug eluting balloon (all sizes)
Paclitaxel coated coronary drug eluting balloon US FDA/CE approved/certified Paclitaxel coated coronary drug eluting balloon (all sizes)
Peripheral Angioplasy Balloons Peripheral Angioplasy Balloons, hydrophobic coating A.0.014” wire compatible , Monorail & OTW 5-12 mm B.0.035” wire compatible, Monorail & OTW 5-12 mm C.0.035” wire compatible ,Monorail & OTW 14-25 mm
Peripheral balloon expandable Cobalt Chromium Stents European CE approved/certified OR DCGI approved Peripheral Cobalt Chromium Stent all sizes both OTW and monorail
Peripheral balloon expandable Nitinol Stents European CE approved/certified OR DCGI approved Peripheral Nitinol Stent all sizes both OTW and monorail
Peripheral balloon expandable Stainless Steel Stents European CE approved/certified OR DCGI approved Peripheral Stainless Steel Stent all sizes both OTW and monorail
Peripheral Cobalt Chromium Stent US FDA/CE approved/certified Peripheral Cobalt Chromium Stent all sizes both OTW and monorail
Peripheral Drug eluting balloon European CE approved/ certified OR DCGI approved Peripheral Drug eluting balloon; All sizes, quote separately
Peripheral Nitinol Stent US FDA/CE approved/certified Peripheral Nitinol Stent all sizes both OTW and monorail
Peripheral self-expanding stents European CE approved/certified OR DCGI approved Monorail based nitinol peripheral self-expanding stent all sizes
PIG TAIL CATHETERS 5F. PIG TAIL CATHETERS 5F. Should be FDA'/CE'/DCGI approved
PIG TAIL CATHETERS, 6F. PIG TAIL CATHETERS, 6F. Should be FDA'/CE'/DCGI approved
PIG-TAIL CATHETER PEDIATRIC 4 F. PIG-TAIL CATHETER PEDIATRIC 4 F. Should be FDA'/CE'/DCGI approved
Plastic luer lock syringe, 10 cc with finger grip. Sterile Plastic Contrast injecting luer lock controlled syringe 10 cc with finger grip.
Plastic luer lock syringe, 10 cc without finger grip. Sterile Plastic Contrast injecting luer lock controlled syringe 10 cc without finger grip.
Plastic luer lock syringe, 12 cc with finger grip. Sterile Plastic Contrast injecting luer lock controlled syringe 12 cc with finger grip.
Plastic luer lock syringe, 12 cc without finger grip. Sterile Plastic Contrast injecting luer lock controlled syringe 12 cc without finger grip.
Plastic luer lock syringe, 2 cc without finger grip. Sterile Plastic Contrast injecting luer lock controlled syringe 2 cc without finger grip.
Plastic luer lock syringe, 20 cc with finger grip. Sterile Plastic Contrast injecting luer lock controlled syringe 20 cc with finger grip.
Plastic luer lock syringe, 20 cc without finger grip. Sterile Plastic Contrast injecting luer lock controlled syringe 20 without finger grip.
Platinum chromium base Everolimus coated drug eluting coronary stent , USFDA approved/certified US FDA approved/Certified Platinum chromium base Everolimus coated drug eluting coronary stent (All sizes & Diameters)
Platinum chromium base Sirolimus coated drug eluting coronary stents European CE approved/certified Platinum chromium base Sirolimus coated drug eluting coronary stent (All sizes & Diameters)
Platinum chromium base Zotarolimus coated drug eluting coronary stents European CE approved/certified Platinum chromium base Zotarolimus coated drug eluting coronary stent (All sizes & Diameters)
Platinum chromium based Everolimus coated drug eluting coronary stent European CE approved/certified Platinum chromium based Everolimus coated drug eluting coronary stent (All sizes & Diameters)
PTA guide wire US FDA approved/certified OR CE approved/certified ,steerable PTA guide wire with floppy tip, scitanium stainless steel alloy core, extra-support of 0.018” diameter, ≥300 cm long. a) Tip Non-hydrophilic b) Tip Hydrophilic
PTA high support guide wire US FDA approved/certified OR CE approved/certified, steerable PTA high support guide wire of 0.018”, body PTFE/hydrophobic coated, distal hydrophilic coating, distal radiopacity of 2 cm a) 180-190 cm long b) ≥300 cm long
PTCA accessories kit containing with spring type push and release mechanism Y Connector US FDA approved/certified OR CE approved/certified OR DCGI approved/certified, PTCA accessories kit containing a) Y-connector hemostatic valve with spring type push and release mechanism (Touhy borst system),b) Torque device & c) Introduce needle.
PTCA accessories kit with rotating type Y connector US FDA approved/certified or CE approved/certified, PTCA accessories kit containing a) Y-connector hemostatic valve with rotating mechanism (Touhy borst system),b) Torque device & c) Introducer needle.
PTCA balloon high pressure non-compliant US FDA approved/certified high pressure non-compliant balloon smooth, rounded distal tip and no edge over-dilatation at higher pressure; with least balloon overhang at the edges. Diameter (mm): 2.5, 2.75, 3.0, 3.25, 3.5, 3.75, 4, 4.5, 5.0 Length (mm): minimum 6-8mm to ≥20 mm.
PTCA extra support guide wire with durasteel core material US FDA approved/certified OR CE approved/certified, steerable PTCA extra support guide wire with durasteel core material, core to tip design, floppy tip, standard size a) With hydrophobic coating. b) With hydrophilic coating.
PTCA extra-support guide wire. US FDA approved/certified OR CE approved/certified, PTCA extra-support guide wire with PTFE coating over shaft, tip load of 0.7 gm, tip size of 0.014”, and tip radiopacity of 4 cm. a) 180-190 cm long. b) 280-300 cm long.
PTCA guide wire for CTO with extra-support US FDA approved/certified OR CE approved/certified, PTCA guide wire for CTO with extra-support, tip load of 9 gm, tip size of 0.009”, length 180-190 cm, with a) Spring coil and tip radiopacity of 11 cm. b) Spring coil and tip radiopacity of 20 cm.
PTCA guide wire for CTO with PTFE coating over shaft US FDA approved/certified OR CE approved/certified, PTCA guide wire for CTO with PTFE coating over shaft, tip size of 0.014”, tip radiopacity of 11 cm and length of 180-190 cm Tip load of a) 2-3 gm. b) 4-5 gm. c) 6-7 gm. d) 12-13 gm
PTCA guide wire with floppy tip, hydrophilic coating US FDA approved/certified OR CE approved/certified,steerable PTCA guide wire with floppy tip, elastinite core, soft shaping ribbon tip and hydrophilic coating. a) 180-190 cm. b) 280-300 cm.
PTCA guide wire with floppy tip, hydrophobic coating US FDA approved/certified OR CE approved/certified, steerable PTCA guide wire with floppy tip, elastinite core, soft shaping ribbon tip and hydrophobic coating. a) 180-190 cm. b) 280-300 cm.
PTCA guide wire with PTFE coating over shaft US FDA approved/certified OR CE approved/certified, PTCA guide wire with PTFE coating over shaft, tip load of 0.8 gm, tip size of 0.014”, tip radiopacity of 3 cm. a) 180-190 cm long. b) 280-300 cm long.
PTCA guide wire with PTFE coating over shaft, tip radiopacity of 16 cm. US FDA approved/certified OR CE approved/certified, PTCA guide wire with PTFE coating over shaft,tip load of 0.8 gm, tip size of 0.009”, tip radiopacity of 16 cm. a) 180-190 cm long. b) 280-300 cm long.
PTCA guide wires, 0.014”, 180-190 cm long US FDA approved/certified OR CE approved/certified ,PTCA guide wires, 0.014”, 180-190 cm long, Nitinol distal super elastic core for kink resistance and shape retention, Silicon coating for distal 2 cm and hydrophilic coating of rest of the wire length, a) Tip load of 0.9-1.0 gm b) Tip load of 0.6-0.8 gm c) Tip load of 3.5-4.0 gm
PTCA guidewire joint less spring coil 0.014” US FDA approved/certified OR CE approved/certified,joint less spring coil 0.014” one piece core PTCA guide wire with tip radiopacity 3 cm, length 180 cm. a) Tip load 0.7-0.8 gm. b) Tip load 0.5-0.6 gm.
PTCA guiding catheters US FDA approved/certified OR CE approved/certified, PTCA Guiding catheter, ≥100 cm long. It should be large lumen braided, inner layer coated with PTFE. It should have atraumatic soft tip with radio opaque marker band at the tip. a) Judkins left without side holes (Curves 3, 3.5, 4, 5 cm), Size 5F/6F/7F/8F. b) Judkins left with side holes (Curves 3, 3.5, 4, 5 cm), Size 5F/6F/7F/8F. c) Judkins left with short tip (Curves 3, 3.5, 4, 5 cm), Size5F/6F/7F/8F. d) Judkins Right without side holes (Curves 3, 3.5, 4, 5 cm), Size 5F/6F/7F/8F. e) Judkins Right with side holes (Curves 3, 3.5, 4, 5 cm), Size 5F/6F/7F/8F. f) Judkins Right with short tip (Curves 3, 3.5, 4, 5 cm), Size 5F/6F/7F/8F. g) IMA guiding catheter, 5F/6F/7F. h) Multipurpose (AI, AII), 5F/6F/7F/8F. i) Multipurpose (BI, BII), 5F/6F/7F/8F. j) Amplatz Left without side holes (Curves AL0.75, AL1, AL1.5, AL2,AL3),5F/6F/7F/8F. k) Aplatz Left with side holes (Curves AL0.75, AL1, AL1.5, AL2, AL3), 5F/F/7F/8F. l) Amplatz Right without side holes (Curves AR1, AR2), 5F/6F/7F/8F. m) Amplatz Right with side holes (Curves AR1, AR2), 5F/6F/7F/8F. n) Voda Left, 5F/6F/7F/8F. o) Voda Right, 5F/6F/7F/8F. p) Left coronary bypass guide catheter, 6F/7F. q) Right coronary bypass guide catheter, 6F/7F. r) Contra Lateral Support (CLS) left without side holes, 5F/6F/7F/8F. s) Contra Lateral Support (CLS) left with side hole, 5F/6F/7F/8F. t) Contra Lateral Support (CLS) right without side hole, 5F/6F/7F/8F. u) Contra Lateral Support (CLS) right with side hole, 5F/6F/7F/8F. v) 3D right guiding catheter without side hole, 6F/7F. w) 3D right guiding catheter with side hole, 6F/7F. x) Hockey Stick guiding catheter, 6F/7F. y) Shepherd Crook right type guiding (Curves 3.5, 4, 5), 6F/7F. z) Head Hunter guiding catheter, 6F/7F. aa) Extraback up (EBU 3, 3.5, 4) catheters, 5F/6F/7F/8F ab) Extraback up right (EBU right 3, 3.5, 4) catheters, 5F/6F/7F/8F
PTRA guide wire for Renal Angioplasty, diameter 0.018”, 100- 110 cm long. PTRA guide wire for Renal Angioplasty, diameter 0.018”, 100- 110 cm long.
Radial Artery compression band Radial Artery compression band consists of two balloons specially designed for spot compression of the radial puncture site, Preferred make Terumo, Meritt, Medtronics
Radial Diagnostics Catheter with the unique tiger type Curve Radial Diagnostics Catheter with the unique tiger type Curve which enables angiography of right and left Coronary arteries using either radial or Brachial approach, Preferred make Terumo, Cordis, Medtronics
Radial introducer Sheath, 5F Radial introducer Sheath with haemostatic valve, 5F, 20Gx2" puncture needle with Plastic IV catheter and 0.025" Radifocus mini plastic guidewire, Preferrred make Terumo, Cordis, Medtronics
Radial introducer Sheath, 6F Radial introducer Sheath with haemostatic valve, 6F, 20Gx2" puncture needle with Plastic IV catheter and 0.025" Radifocus mini plastic guidewire, Preferrred make Terumo, Cordis, Medtronics
Radial introducer Sheath, 7F Radial introducer Sheath with haemostatic valve, 7F, 20Gx2" puncture needle with Plastic IV catheter and 0.025" Radifocus mini plastic guidewire, Preferrred make Terumo, Cordis, Medtronics
Renal Stents, cobalt chromium, CE or DCGI approved/cerified European approved/ Certified OR DCGI approved Balloon Mounted Monorail 0.014" Compatible Cobalt chromium renal Stent diameter 4-7 mm Length 10-24 mm
RIGHT CORONARY BY PASS DIAGNOSTIC CATHETER RIGHT CORONARY BY PASS CATHETER 4F,5F,6F all Curves. Should be FDA'/CE'/DCGI approved
Short tube of 12 to 15 inches to connect to touhy borst Short tube of 12 to 15 inches to connect to touhy borst
Sirolimus coated coronary drug eluting balloon European CE certified/DCGI approved Sirolimus coated coronary drug eluting balloon (all sizes)
Stainless steel base Everolimus coated drug eluting coronary stents European CE approved/certified Stainless steel base Everolimus coated drug eluting coronary stent (All sizes & Diameters)
Stainless steel base Sirolimus coated drug eluting coronary stent European CE approved/certified Stainless steel base Sirolimus coated drug eluting coronary stent (All sizes & Diameters)
Stainless steel base Zotarolimus coated drug eluting coronary stent European CE approved/certified Stainless steel base Zotarolimus coated drug eluting coronary stent (All sizes & Diameters)
Stainless Steel renal Stent, CE or DCGI approved European CE approved/certified OR DCGI approved Balloon Mounted Monorail 0.014" Compatible Stainless Steel renal Stent diameter 4-7 mm Length 10-24 mm
Sterile Lead free Radiation Protection Drape for use in cath lab Sterile Lead free Radiation Protection Drape for use in cath lab, Lead equivalency should be at least 0.125mm Pb and must be USFDA/CE approved and anti-toxicity certificate.
Temporary Pacing Electrode catheter Temporary Pacing Electrode catheter: Must be NBIH(TM) standard, Must have Soft-Tip Bipolar Electrode, Sizes-6 French 125 cm
Terumo guidewire 0.021'' straight tip ,150 cm
Thin struts Everolimus eluting coronary stent European CE approved/certified OR DCGI approved Everolimus eluting coronary stent with thin struts (50μm), all sizes
Thrombus Aspiration Catheter Thrombus Aspiration Catheter, Preloaded stylet with soft, Short forward-facing tip design; 6F Compatible (Preferred make Medtronic, Cordis, Terumo)
Transseptal puncture needle (Brockenbrough type), adult Brockenbrough type transseptal needle, adult, stainless steel, 18 gauze shaft, 21 gauze tip, 71 cm length
Ultrasound contrast agent for contrast echo Ultrasound contrast agent for contrast echo, 2ml, should be USFDA/CE/DCGI approved
US FDA approved Sirolimus coated coronary drug eluting balloon (all sizes) US FDA approved Sirolimus coated coronary drug eluting balloon (all sizes)
US FDA approved/certified Balloon Mounted Monorail 0.014" Compatible Cobalt chromium renal Stent US FDA approved/certified Balloon Mounted Monorail 0.014" Compatible Cobalt chromium renal Stent diameter 4-7 mm Length 10-24 mm
US FDA approved/certified Balloon Mounted Monorail 0.014" Compatible Stainless Steel renal Stent US FDA approved/certified Balloon Mounted Monorail 0.014" Compatible Stainless Steel renal Stent diameter 4-7 mm Length 10-24 mm
US FDA approved/certified Peripheral Stainless Steel Stent all sizes both OTW and monorail US FDA approved/certifiedPeripheral Stainless Steel Stent all sizes both OTW and monorail
US FDA approved/Certified Platinum chromium base Sirolimus coated drug eluting coronary stent US FDA approved/Certified Platinum chromium base Sirolimus coated drug eluting coronary stent (All sizes & Diameters)
US FDA approved/certified Platinum chromium base Zotarolimus coated drug eluting coronary stent US FDA approved/certified Platinum chromium base Zotarolimus coated drug eluting coronary stent (All sizes & Diameters)
US FDA approved/certified PTCA pre-dilatation semi-compliant balloon for CTO US FDA approved/certified PTCA pre-dilatation semi-compliant balloon with lowest tip entry profile of ≤0.017”, lowest crossing profile for crossing CTO or difficult to cross lesions and smallest balloon size of 1.0/1.1 mm diameter and length of 6-8 mm with single marker at the center of the balloon. Other diameters of 1.2/1.25mm, 1.5mm, 2mm, 2.5mm, 3mm. Other lengths of 10-12mm, 15-18mm, 20-22mm, 25mm or more.
US FDA approved/certified PTCA Pre-dilatation, monorail balloon (semi compliant) US FDA approved/certified PTCA Pre-dilatation, monorail balloon (semi compliant).Low entry profile (≤0.017”) and 5F guide catheter compatibility. Diameters (mm): 0.75,1.0 ,1.2/1.25, 1.5, 2.0, 2.5, 3, 3.5, 4.0. Length: minimum 6-8 mm to 20 mm or more.
US FDA approved/Certified Stainless steel base Everolimus coated drug eluting coronary stent US FDA approved/Certified Stainless steel base Everolimus coated drug eluting coronary stent (All sizes & Diameters)
US FDA approved/Certified Stainless steel base Sirolimus coated drug eluting coronary stent US FDA approved/Certified Stainless steel base Sirolimus coated drug eluting coronary stent (All sizes & Diameters)
US FDA approved/certified Stainless steel base Zotarolimus coated drug eluting coronary stent US FDA approved/certified Stainless steel base Zotarolimus coated drug eluting coronary stent(All sizes & Diameters)
US FDA approved/certified ultra-low entry profile Semi Compliant Balloon US FDA approved/certified ultra-low entry profile Semi Compliant Balloon with 0.40mm or 0.016” and entry profile from 1.25*10 to 2.25*10 remains same for exceptional crossability even with higher diameter balloon.
US FDA approved/certified, PTCA pre-dilatation semi-compliant over the wire balloon US FDA approved/certified, PTCA pre-dilatation semi-compliant over the wire balloon with short balloon taper, low entry profile (≤0.016”). Diameter –1.2/1.25, 1.5, 2.0, 2.5, 3.0 mm or more Length – minimum 6-8 mm to 20mm.
US FDA approved/certifiedEverolimus eluting stent with thin struts (50μm) US FDA approved/certifiedEverolimus eluting stent with thin struts (50μm)
US FDA approved/certifiedMonorail based nitinol peripheral self-expanding stent US FDA approved/certifiedMonorail based nitinol peripheral self-expanding stent all sizes
US FDA approved/certifiedPeripheral Drug eluting balloon US FDA approved/certifiedPeripheral Drug eluting balloon; All sizes, quote separately
US FDA/CE/DCGI approved/certified bare metal coronary stent US FDA/CE/DCGI approved/certified bare metal coronary stent (All sizes & Diameters)
Valvuloplasty Balloon (Dumbell Shaped) Numed type Valvuloplasty Balloon (Dumbell Shaped) Numed type ,all sizes with accessories
Valvuloplasty Balloon Tyshak Type 0.25 & 0.35 system Valvuloplasty Balloon Tyshak Type 0.25 & 0.35 system
VVIR pacemaker with International standard warranty VVIR pacemaker with International standard warranty *US FDA approved/certified pacemaker with lead & accessories *All single Chamber modes and basic multi-programmable parameters with preferably autosensing and auto-capture/output management facilities. *Must have Ventricular Capture Management. *Monitor the integrity of lead and switch polarity in case of issue *The Size of lead should be 7F or less. *The Lead must be steroid eluting and should be both bipolar and unipolar configuration. *Must have both active and passive fixation endocardial leads available. *Company must provide at least one programmer exclusively to the department of cardiology AIIMS Bilaspur. *Company must provide its trained technical person for each implantation and for follow up programming whenever required. *Company must quote only the latest model of devices commercially available *Model with International standard warranty (at least 7 years or more)
VVIR pacemaker with International standard warranty, 1.5 T MRI Conditional VVIR pacemaker with International standard warranty, 1.5 T MRI Conditional *US FDA approved/certified pacemaker with lead & accessories *All single Chamber modes and basic multi-programmable parameters with preferably autosensing and auto-capture/output management facilities. *Must have Ventricular Capture Management. *Monitor the integrity of lead and switch polarity in case of issue *The Size of lead should be 7F or less. *The Lead must be steroid eluting and should be both bipolar and unipolar configuration. *Must have both active and passive fixation endocardial leads available. *Company must provide at least one programmer exclusively to the department of cardiology AIIMS Bilaspur. *Company must provide its trained technical person for each implantation and for follow up programming whenever required. *Company must quote only the latest model of devices commercially available *Should allow full body 1.5T MRI scan without any restriction zone with with International standard warranty (at least 7 years or more)
VVIR pacemaker with International standard warranty, 3 T MRI Conditional VVIR pacemaker with International standard warranty, 3 T MRI Conditional *US FDA approved/certified pacemaker with lead & accessories *All single Chamber modes and basic multi-programmable parameters with preferably autosensing and auto-capture/output management facilities. *Must have Ventricular Capture Management. *Monitor the integrity of lead and switch polarity in case of issue *The Size of lead should be 7F or less. *The Lead must be steroid eluting and should be both bipolar and unipolar configuration. *Must have both active and passive fixation endocardial leads available. *Company must provide at least one programmer exclusively to the department of cardiology AIIMS Bilaspur. *Company must provide its trained technical person for each implantation and for follow up programming whenever required. *Company must quote only the latest model of devices commercially available *Should allow full body 3T MRI scan without any restriction zone with International standard warranty (at least 7 years or more)
VVIR pacemaker with lifetime warranty VVIR pacemaker with lifetime warranty *US FDA approved/certified pacemaker with lead & accessories *All single Chamber modes and basic multi-programmable parameters with preferably autosensing and auto-capture/output management facilities. *Must have Ventricular Capture Management. *Monitor the integrity of lead and switch polarity in case of issue *The Size of lead should be 7F or less. *The Lead must be steroid eluting and should be both bipolar and unipolar configuration. *Must have both active and passive fixation endocardial leads available. *Company must provide at least one programmer exclusively to the department of cardiology AIIMS Bilaspur. *Company must provide its trained technical person for each implantation and for follow up programming whenever required. * Company must quote only the latest model of devices commercially available *Model with International life time warranty.
VVIR pacemaker with lifetime warranty, 1.5 T MRI Conditional VVIR pacemaker with lifetime warranty, 1.5 T MRI Conditional *US FDA approved/certified pacemaker with lead & accessories *All single Chamber modes and basic multi-programmable parameters with preferably autosensing and auto-capture/output management facilities. *Must have Ventricular Capture Management. *Monitor the integrity of lead and switch polarity in case of issue *The Size of lead should be 7F or less. *The Lead must be steroid eluting and should be both bipolar and unipolar configuration. *Must have both active and passive fixation endocardial leads available. *Company must provide at least one programmer exclusively to the department of cardiology AIIMS Bilaspur. *Company must provide its trained technical person for each implantation and for follow up programming whenever required. * Company must quote only the latest model of devices commercially available *Should allow full body 1.5T MRI scan without any restriction zone with Life time international warranty.
VVIR pacemaker with lifetime warranty, 3 T MRI Conditional VVIR pacemaker with lifetime warranty, 3 T MRI Conditional *US FDA approved/certified pacemaker with lead & accessories *All single Chamber modes and basic multi-programmable parameters with preferably autosensing and auto-capture/output management facilities. *Must have Ventricular Capture Management. *Monitor the integrity of lead and switch polarity in case of issue *The Size of lead should be 7F or less. *The Lead must be steroid eluting and should be both bipolar and unipolar configuration. *Must have both active and passive fixation endocardial leads available. *Company must provide at least one programmer exclusively to the department of cardiology AIIMS Bilaspur. *Company must provide its trained technical person for each implantation and for follow up programming whenever required. * Company must quote only the latest model of devices commercially available *Should allow full body 3T MRI scan without any restriction zone with Life time international warranty.
Y-connector hemostatic valve with push-release mechanism Y-connector hemostatic valve with push-release mechanism
Y-connector hemostatic valve with rotating mechanism Y-connector hemostatic valve with rotating mechanism
Adult Closed blood sampling system (VAMP) Needle-less cannula, 20" sampling kit
Airway exchange Catheter with ventilation port 14Fr diameter, 80cm length with 15mm adapter and luer-lock
Airway exchange Catheter with ventilation port 11Fr diameter, 80cm length with 15mm adapter and luer-lock
Airway exchange Catheter with ventilation port, 19Fr diameter, 80cm length with 15mm adapter and luer-lock
Angle piece for EtCO2 port Anlgled connector for EtCO2 sensing
Antegrade Aortic Root Cardioplegia Cannula with Vent line, 5Fr with flanged tip and standard introducer needle, preferably with side holes-SPR
Aortic /arterial Perfusion Cannula Angled (45 deg) wirewound - Size 22Fr with flanges - Overall at least 12 inches with transparent & wirewound body, angled (45 deg) bevelled tip with side holes, tip orientation line and tip guard preferably with vented type connector - SPR
Aortic /arterial Perfusion Cannula Angled (45 deg) wirewound - Size 20Fr/21Fr with flanges - Overall at least 12 inches with transparent & wirewound body, angled (45 deg) bevelled tip with side holes, tip orientation line and tip guard preferably with vented type connector - SPR
Aortic /arterial Perfusion Cannula Angled (45 deg) wirewound - Size 18Fr with flanges - Overall at least 12 inches with transparent & wirewound body, angled (45 deg) bevelled tip with side holes, tip orientation line and tip guard preferably with vented type connector - SPR
Aortic /arterial Perfusion Cannula Angled (45 deg) wirewound - Size 16Fr with flanges - Overall at least 12 inches with transparent & wirewound body, angled (45 deg) bevelled tip with side holes, tip orientation line and tip guard preferably with vented type connector - SPR
Arterial Cannula with floswitch Sterile. Disposable 22G diameter Should be provided with fixation wings and introducer needle
Arterial embolectomy Fogarty's catheter 5Fr x 80 cm - enclosed in a rigid case - SPR
Arterial embolectomy Fogarty's catheter 6Fr x 80 cm - enclosed in a rigid case - SPR
Arterial embolectomy Fogarty's catheter 7Fr x 80 cm - enclosed in a rigid case - SPR
Arterial embolectomy Fogarty's catheter 3Fr x 80 cm - enclosed in a rigid case - SPR
Arterial embolectomy Fogarty's catheter 4Fr x 80 cm - enclosed in a rigid case - SPR
Arterial Filter 40ml prime volume @ max. 3-4L/min flow rate, 30µm screen size, 1/4" inlet and outlet connectors. Primary Pack should be labelled. SPR
Arterial Filter 28ml prime volume @ max 2-3L/min flow rate, 40µm screen size, 1/4" inlet and outlet connectors. Primary Pack should be labelled. SPR
Arterial Filter 100ml priming volume @ max. 6-8L/min flow rate, 25-30µm screen size, 3/8" inlet and outlet connectors. Primary Pack should be labelled. SPR
Arterial Leadercath set 18G Made of PTFE, 18G diameter
Arterial Leadercath set 20 G Made of PTFE, 20G diameter
Arteriotomy Cannulae Bulb-shaped tip- 6cm length, 3mm tip, winged female leur at one end. SPR
Arteriotomy Cannulae Bulb-shaped tip- 6cm length, 4mm tip, winged female leur at one end. SPR
Arteriotomy Cannulae Bulb-shaped tip- 6cm length, 2mm tip, winged female leur at one end.SPR
Asepto syringes Transparent bulb irrigation syringe 60ml capacity
Bileaflet Mechanical Aortic Valve All sizes (16/17mm-23/24mm)- The valve should be rotatable after seating. To be supplied with the suitable holder, sizer and leaflet tester have to be suppied along with the valve. Purchase will be made individually whenever necessary on SOS basis (Consignment mode, i.e., different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)).
Bileaflet Mechanical Mitral Valve All sizes (24/25mm-33/34mm)- The valve should be rotatable after seating. To be supplied with the suitable holder, sizer and leaflet tester have to be suppied along with the valve. Purchase will be made individually whenever necessary on SOS basis (Consignment mode, i.e., different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)).
BIS Sensor-Adult 8.75 in. x 7.75 in. (approx.), Polycarbonate plastic connector (patient contact surface), Tab stiffener made of Polycarbonate sheet with one side coated with adhesive, Module made of Copper/brass/Kapton, Flexible circuit made of Polyester screen printed with cured Ag/AgCl and dielectric inks (for incidental patient contact), Electrode tines retaining disk of size 1/32 inch with white polyethylene foam with both sides coated with medical-grade adhesive, Basepad having 1/16 inch white polyethylene foam with both sides coated with medical-grade adhesive
BOC mask, Size 1 Reusable Should be Connel type mask made of conductive neoprene with latex rubber Should have a five-pronged ring which will accommodate any two-, three-, or four-tailed harness on all sizes Should have 22mm female inlet
BOC mask, Size 2 Reusable Should be Connel type mask made of conductive neoprene with latex rubber Should have a five-pronged ring which will accommodate any two-, three-, or four-tailed harness on all sizes Should have 22mm female inlet
BOC mask, Size 3 Reusable Should be Connel type mask made of conductive neoprene with latex rubber Should have a five-pronged ring which will accommodate any two-, three-, or four-tailed harness on all sizes Should have 22mm female inlet
BOC mask, Size 4 Reusable Should be Connel type mask made of conductive neoprene with latex rubber Should have a five-pronged ring which will accommodate any two-, three-, or four-tailed harness on all sizes Should have 22mm female inlet
BOC mask, Size 5 Reusable Should be Connel type mask made of conductive neoprene with latex rubber Should have a five-pronged ring which will accommodate any two-, three-, or four-tailed harness on all sizes Should have 22mm female inlet
Bovine pericardial patch 10x15cm, Tissue thickness 0.5 mm. Packaged sterile in container with glutaraldehyde.
Bovine pericardial/Porcine stented bioprosthetic Aortic Valve All sizes (21/22mm-24/25mm)- To be supplied with holder & sizer set. Purchase will be made individually whenever necessary - S.O.S. on consignment mode
Bovine pericardial/Porcine stented bioprosthetic Mitral valve All sizes (25/26mm-33/34mm)- To be supplied with holder & sizer set. Purchase will be made individually whenever necessary - S.O.S. on consignment mode
Cardioplegia delivery system (CPDS) 4:1 type - PV ≤ 30ml, Max BFR ≥ 2.5 L/min with 3-way with purge line. Preferably with grooved stainless steel HE & 150 μm polyester screen filter. Primary Pack should be labelled. Holder to be supplied. SPR
Carotid Artery Bypass Shunt Straight, One side hole each end, 10Fr in diameter, length 13cm. SPR
Carotid Artery Bypass Shunt Straight, One side hole each end, 12Fr in diameter, length 13cm. SPR
Carotid Artery Bypass Shunt Straight, One side hole each end, 14Fr in diameter, length 13cm. SPR
Central Intravenous Catheter (CVP line) Triple lumen, 5Fr
Central Intravenous Catheter (CVP line) Triple lumen, 6Fr
Chest binders Large Size Large High cushioning chest pad Should have broad hook-loop panel Should be made of heat resistant rubber
Chest binders Medium Size Medium High cushioning chest pad Should have broad hook-loop panel Should be made of heat resistant rubber
Chest binders Small Size Small High cushioning chest pad Should have broad hook-loop panel Should be made of heat resistant rubber
Chest binders XL Size XL High cushioning chest pad Should have broad hook-loop panel Should be made of heat resistant rubber
Chlorhexidine gluconate impregnated IV dressing (Tegaderm) 10x12cm dressing size. 2x2cm CHG Gel pad size. SPR
Chlorhexidine gluconate impregnated IV dressing (Tegaderm) 8x7cm dressing size. 2x2cm CHG Gel pad size. SPR
Clave connectors (Needle free connectors) 0.1ml residual volume, compatible with blood, 100ml/minute flow rate at gravity, high pressure compatibility at 10ml/second, clear housing, should be able to prevent blood reflux into the catheter
Clave IV Bag Access Device 13 cm length. Without hand pump and not filtered. Should be Non-DEHP.
Close Wound Suction Unit (Romo Vac Set) Sterile. 14Fr. Needle length 175cm. Bellow capacity 400ml. Drain catheters should be provided with size colour coded, radio opaque line and satin smooth eyes. Connecting tube should be kink resistant. Unit should consist of a Bellow unit, a Connecting tube with clamp and "Y" connector, a Curved needle attached to matching size catheter and a Spare catheter.
Close Wound Suction Unit (Romo Vac Set). Sterile. 12Fr. Needle length 175cm. Bellow capacity 500ml. Drain catheters should be provided with size colour coded, radio opaque line and satin smooth eyes. Connecting tube should be kink resistant. Unit should consist of a Bellow unit, a Connecting tube with clamp and "Y" connector, a Curved needle attached to matching size catheter and a Spare catheter.
Custom Tubing Pack Adult- Sterile, Disposable, Transparent. Contact Deptt. of Cardiothoracic Surgery for the drawings.
Custom Tubing Pack Small Adult- Sterile, Disposable, Transparent. Contact Deptt. of Cardiothoracic Surgery for the drawings.
Custom Tubing Pack Pediatric- Sterile, Disposable, Transparent. Contact Deptt. of Cardiothoracic Surgery for the drawings.
Dextrose- 10% Infusion fluid containing 10% dextrose
Dextrose- 25% Infusion fluid containing 25% dextrose
Dextrose- 5% Infusion fluid containing 5% dextrose
Disposable Aortic -Vascular Punch 4 mm - with smooth telescoping movement & adequate finger grip mechanism. SPR
Disposable Aortic -Vascular Punch 3.5 mm - with smooth telescoping movement & adequate finger grip mechanism. SPR
Disposable blood pressure transducer kit
Disposable electrocautery plate. Single use. Adhesive Corded patient return electrodes.
Disposable Laryngoscope with blades, Size 0 Solid metal construction from tip to heel Integrated LED bulb provides optimal light output Blades are colour coded by size for easy identification Reliable "click" locking mechanism Compatible with ISO 7376-compliant standard system laryngoscope handles
Disposable Laryngoscope with blades, Size 1 Solid metal construction from tip to heel Integrated LED bulb provides optimal light output Blades are colour coded by size for easy identification Reliable "click" locking mechanism Compatible with ISO 7376-compliant standard system laryngoscope handles
Disposable Laryngoscope with blades, Size 2 Solid metal construction from tip to heel Integrated LED bulb provides optimal light output Blades are colour coded by size for easy identification Reliable "click" locking mechanism Compatible with ISO 7376-compliant standard system laryngoscope handles
Disposable Laryngoscope with blades, Size 3 Solid metal construction from tip to heel Integrated LED bulb provides optimal light output Blades are colour coded by size for easy identification Reliable "click" locking mechanism Compatible with ISO 7376-compliant standard system laryngoscope handles
Disposable Laryngoscope with blades, Size 4 Solid metal construction from tip to heel Integrated LED bulb provides optimal light output Blades are colour coded by size for easy identification Reliable "click" locking mechanism Compatible with ISO 7376-compliant standard system laryngoscope handles
Disposable Microscalpel with high quality micro-blade attached for coronary arteriotomy - SPR
DNS 0.45% Sterile. 500ml bag/bottle
Double Lumen 37 Fr Right Sterile. Disposable Material of Tube (Medical grade): PVC/Silicon Matrerial of tube should be non toxic and latex Free Should be DEHP Free Tube Should be Cuffed tube (Tracheal cuff and Bronchial cuff) The cuffs, two lumens and pilot balloons should be color coded for easy identification Kink resistant thermostatic tube Radio opaque line on tube Provision of Murphy eye Intubation depth marking on tube should be present Size of the Tube: 37Fr, Right sided Provided with connector Size of Connector: 15mm Provided with individual port blocking clamp Intubation depth marking on tube should be present Should be provided with individual port blocking clamp
Double Lumen Endotracheal tube, 32 Fr Left sided Sterile. Disposable Material of Tube (Medical grade): PVC/Silicon Matrerial of tube should be non toxic and latex Free Should be DEHP Free Tube Should be Cuffed tube (Tracheal cuff and Bronchial cuff) The cuffs, two lumens and pilot balloons should be color coded for easy identification Kink resistant thermostatic tube Radio opaque line on tube Provision of Murphy eye Intubation depth marking on tube should be present Size of the Tube: 32Fr Left sided Provided with connector Size of Connector: 15mm Provided with individual port blocking clamp Intubation depth marking on tube should be present Should be provided with individual port blocking clamp
Double Lumen Endotracheal tube, 32 Fr Right sided Sterile. Disposable Material of Tube (Medical grade): PVC/Silicon Matrerial of tube should be non toxic and latex Free Should be DEHP Free Tube Should be Cuffed tube (Tracheal cuff and Bronchial cuff) The cuffs, two lumens and pilot balloons should be color coded for easy identification Kink resistant thermostatic tube Radio opaque line on tube Provision of Murphy eye Intubation depth marking on tube should be present Size of the Tube: 32Fr Right sided Provided with connector Size of Connector: 15mm Provided with individual port blocking clamp Intubation depth marking on tube should be present Should be provided with individual port blocking clamp
Double Lumen Endotracheal tube, 37 Fr Left sided Sterile. Disposable Material of Tube (Medical grade): PVC/Silicon Matrerial of tube should be non toxic and latex Free Should be DEHP Free Tube Should be Cuffed tube (Tracheal cuff and Bronchial cuff) The cuffs, two lumens and pilot balloons should be color coded for easy identification Kink resistant thermostatic tube Radio opaque line on tube Provision of Murphy eye Intubation depth marking on tube should be present Size of the Tube: 37Fr Left sided Provided with connector Size of Connector: 15mm Provided with individual port blocking clamp Intubation depth marking on tube should be present Should be provided with individual port blocking clamp
Double LumenEndotracheal tube, 35 Fr Left sided Sterile. Disposable Material of Tube (Medical grade): PVC/Silicon Matrerial of tube should be non toxic and latex Free Should be DEHP Free Tube Should be Cuffed tube (Tracheal cuff and Bronchial cuff) The cuffs, two lumens and pilot balloons should be color coded for easy identification Kink resistant thermostatic tube Radio opaque line on tube Provision of Murphy eye Intubation depth marking on tube should be present Size of the Tube: 35Fr Left sided Provided with connector Size of Connector: 15mm Provided with individual port blocking clamp Intubation depth marking on tube should be present Should be provided with individual port blocking clamp
Elongated Aortic /arterial Perfusion Cannula Pediatric Size 12Fr - With elongated thin walled bevelled tip - vented type - depth markings - overall at least 9 inch long with introducer -SPR
Elongated Aortic /arterial Perfusion Cannula Pediatric Size 14Fr - With elongated thin walled bevelled tip - vented type - depth markings - overall at least 9 inch long with introducer -SPR
Elongated Aortic /arterial Perfusion Cannula Pediatric Size 10Fr - With elongated thin walled bevelled tip - vented type - depth markings - overall at least 9 inch long with introducer -SPR
Elongated Aortic /arterial Perfusion Cannula Pediatric Size 8Fr - With elongated thin walled bevelled tip - vented type - depth markings - overall at least 9 inch long with introducer -SPR
Endotracheal tube uncuffed 4 mm Sterile.Disposable Material of ET Tube (Non-toxic, Medical Grade): 100%PVC Internal Diameter: 4 millimeter Cuff shape: NA
Endotracheal tube uncuffed 4.5 mm Sterile.Disposable Material of ET Tube (Non-toxic, Medical Grade): 100%PVC Internal Diameter: 4.5 millimeter Cuff shape: NA
Endotracheal tube uncuffed 5 mm Sterile.Disposable Material of ET Tube (Non-toxic, Medical Grade): 100%PVC Internal Diameter: 5 millimeter Cuff shape: NA
Endotracheal tube uncuffed 5.5 mm Sterile.Disposable Material of ET Tube (Non-toxic, Medical Grade): 100%PVC Internal Diameter: 5.5 millimeter Cuff shape: NA
ePTFE Patch 0.6mm thickness, 5x7.5cm. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified. SPR
ePTFE Pericardial Membrane 0.1mm thickness, 6x12cm. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified. SPR
ePTFE Sutures, 3-0 Type Of Needles: Taper Point Double Armed Needle Length: 22mm Needle Curvature: 1/2 circle Suture Length: 90cm Construction: Monofilament Needle: With Governing Specification: USP Category Of Suture: Non absorbable Suture Material: ePTFE pledgeted
Femoral Arterial Perfusion cannula 15F or 16F - with overall length of at least 30 cm with depth marking, introducer, preferably with central lumen & suitable guidewire (.038“ ) and vented connector - SPR
Femoral Arterial Perfusion cannula 17F or 18F - with overall length of at least 30 cm with depth marking, introducer, preferably with central lumen & suitable guidewire (.038“ ) and vented connector - SPR
Femoral Arterial Perfusion cannula 19F or 20F - with overall length of at least 30 cm with depth marking, introducer, preferably with central lumen & suitable guidewire (.038“ ) and vented connector - SPR
Femoral Venous Perfusion cannula 21F or 22 F with multiple side holes, wire wound body, introducer & depth marking preferably with length of at least 50 cm - SPR
Femoral Venous Perfusion cannula 23F or 24 F with multiple side holes, wire wound body, introducer & depth marking preferably with length of at least 50 cm - SPR
Fibrin Sealant (Tisseel Glue), 2ml Liquid hemostatic agent
Fibrin Sealant (Tisseel Glue), 4ml Liquid hemostatic agent
Flexible Silicon Coronary artery ostial cannulae Bulb-shaped tips, 15Fr and tip 2.1mm- SPR
Flexible Silicon Coronary artery ostial cannulae Bulb-shaped tips, 12Fr and tip 2.1mm- SPR
Gelatin granules and human thrombin (Floseal), 5ml Hemostatic agent
Gigli saw handle Reusable. Made of Stainless steel. T-Shaped Design. Distal Hook to securely hold the Gigli saw
Guedel Oropharyngeal Airway Size "0" Should be manufactured from non-toxic, non-irritant PE polymer Color-coded for easy identification Smooth finish and rounded edges should have reinforced bite block to prevent occlusion
Guedel Oropharyngeal Airway Size "00" Should be manufactured from non-toxic, non-irritant PE polymer Color-coded for easy identification Smooth finish and rounded edges should have reinforced bite block to prevent occlusion
Guedel Oropharyngeal Airway Size 1 Should be manufactured from non-toxic, non-irritant PE polymer Color-coded for easy identification Smooth finish and rounded edges should have reinforced bite block to prevent occlusion
Guedel Oropharyngeal Airway Size 2 Should be manufactured from non-toxic, non-irritant PE polymer Color-coded for easy identification Smooth finish and rounded edges should have reinforced bite block to prevent occlusion
Guedel Oropharyngeal Airway Size 3 Should be manufactured from non-toxic, non-irritant PE polymer Color-coded for easy identification Smooth finish and rounded edges should have reinforced bite block to prevent occlusion
Guedel Oropharyngeal Airway Size 4 Should be manufactured from non-toxic, non-irritant PE polymer Color-coded for easy identification Smooth finish and rounded edges should have reinforced bite block to prevent occlusion
Hand rub, Chlorhexidine gluconate 0.5% w/v with Ethyl alcohol 70% v/v 2.5 liters without pump
HbsAg Rapid card kit (Tenders shall be accepted from WHO prequalified kit vendors only) Should detect Hepatitis B surface antigen Should be solid phase/ particle coated with monoclonal antibodies to HBsAg Test Should be able to detect all 11 subtype of HBsAg Test can be performed on Whole blood, Serum and plasma Should yield result within 3 minutes Sensitivity and specifity should be more than 98%
Hemofilter -Adult MSA = 1.1m², PV ≤ 71 ml. To be supplied with tubing set & collection bag & a suitable holder. Primary Pack should be labelled. SPR
Hemofilter -Adult MSA ≤ 1.4m², PV ≤ 80 ml. To be supplied with tubing set & collection bag and a suitable holder. Primary Pack should be labelled.SPR
Hemofilter -Adult MSA ≤ 0.71m², PV ≤ 65 ml. To be supplied with tubing set & collection bag & a suitable holder. Primary Pack should be labelled. SPR
Hemofilter -Pediatric MSA ≤ 0.3m², PV ≤ 35 ml. To be supplied with tubing set & collection bag & a suitable holder. Primary Pack should be labelled. SPR
Hemofilter-Infant MSA ≤0.1m², PV ≤ 20 ml. To be supplied with tubing set & collection bag & a suitable holder. Primary Pack should be labelled. SPR
Hetastarch 6%
HIV rapid card kit (Tenders shall be accepted from WHO prequalified kit vendors only) Should be 4th generation kit Test should be able to detect HIV 1 Antibodies,HIV 2 Antibodies,HIV 1 p24 Ag Test can be performed on Whole blood, Serum and plasma Should yield result within 3 minutes Sensitivity and specifity should be more than 98%
HTK type - single shot cardioplegia. Histidine – Tryptophan – Ketoglutarate (HTK) type cardioplegic solution for myocardial protection for at least 3 hours after a single shot of cardioplegia. 1 litre
Hudson T-piece (Aerosol Tee Connector) 22mm OD x 15mm ID
Hudson T-piece (Aerosol Tee Connector) 22mm OD x 22mm OD.
IMA (Internal Mammary Arterial) cannula 1mm, with bulb shaped tip for checking patency of the artery
Integrated Membrane Extracorporeal Oxygenator with Hard Shell Venous Reservoir - Pediatric MSA ≤ 0.8m², Max BFR 2.1 -2.8 L /min, SPV≤ 100ml, CVR ≤ 1500ml, SS-HE integrated with oxygenator. Primary Pack should be labelled. Holder & Temperature probe to be supplied. SPR
Integrated Membrane Extracorporeal Oxygenator with Hard Shell Venous Reservoir- Adult MSA = 1.4 to 1.8m², Max BFR =6 L/min, SPV ≤ 185ml, CVR ≥ 4500ml. Coated Surface -Polyurethane HE, Primary Pack should be labelled. Holder & Temperature probe to be supplied. SPR
Integrated Membrane Extracorporeal Oxygenator with Hard Shell Venous Reservoir- Adult MSA= 1.5m², Max BFR= 4 L/min, SPV ≤ 135 ml, Hard shell reservoir capacity 3000-3200ml, Metal HE. Primary Pack should be labelled. Holder & Temperature probe to be supplied. SPR
Integrated Membrane Extracorporeal Oxygenator with Hard Shell Venous Reservoir- Infant MSA ≤ 0.5m², Max BFR = 1.5 L /min, SPV ≤ 43ml, Integrated SS-HE. Biocompatible hydrophilic polymer surface coating . Primary Pack should be labelled. Holder & Temperature probe to be supplied. SPR
Integrated Membrane Extracorporeal Oxygenator with Hard Shell Venous Reservoir- Pediatric MSA ≤ 1.1m², Max. BFR 2.8 to3.5L/min, SPV ≤ 130ml, CVR ≥ 2500ml, SS- HE integrated with oxygenator. Primary Pack should be labelled. Holder & Temperature probe to be supplied. SPR
Integrated Membrane Extracorporeal Oxygenator with Hard Shell Venous Reservoir-Pediatric MSA ≤ 0.67m², Max BFR = 2 L/min, SPV ≤ 48ml. Integrated HE of Terephthalate (PET) Primary Pack should be labelled. Holder & Temperature probe to be supplied. SPR
Intracardiac Sump 12" in length, 12Fr- SPR
Intracardiac Sump 15" in length, 20Fr- SPR
Intra-Coronary shunts (silicon type) for intra-operative use for CABG (Coronary Artery Bypass Graft) Bulbed tips, 1.25mm –with 14 mm long & clear shaft-SPR
Intra-Coronary shunts (silicon type)- for intra-operative use for CABG (Coronary Artery Bypass Graft) Bulbed tips, 2.25mm –with 14 mm long & clear shaft-SPR
Intra-Coronary shunts (silicon type)- for intra-operative use for CABG (Coronary Artery Bypass Graft) Bulbed tips, 2mm –with 14 mm long & clear shaft-SPR
Intra-Coronary shunts (silicon type)- for intra-operative use for CABG (Coronary Artery Bypass Graft) Bulbed tips, 1.5mm–with 14 mm long & clear shaft-SPR
Intra-Coronary shunts (silicon type)- for intra-operative use for CABG (Coronary Artery Bypass Graft) Bulbed tips, 1.75mm–with 14 mm long & clear shaft-SPR
Intra-Coronary shunts (silicon type)- for intra-operative use for CABG (Coronary Artery Bypass Graft) Bulbed tips, 1mm –with 14 mm long & clear shaft-SPR
Intra-Coronary shunts (silicon type)- for intra-operative use for CABG (Coronary Artery Bypass Graft) Bulbed tips, 2.5mm –with 14 mm long & clear shaft-SPR
Introducer sheath for femoral access 7Fr, 12cm in length
Introducer sheath for femoral access 8Fr, 12cm in length
Introducer sheath for femoral access 6Fr, 12cm in length
Intubating Stylet, 10Fr Sterile, Latex-free, Made of malleable aluminum covered with a plastic sheath with a lubricated surface. Sheath extends beyond tip.
Intubating Stylet, 14Fr Sterile, Latex-free, Made of malleable aluminum covered with a plastic sheath with a lubricated surface. Sheath extends beyond tip.
Intubating Stylet, 6Fr Sterile, Latex-free, Made of malleable aluminum covered with a plastic sheath with a lubricated surface. Sheath extends beyond tip.
Iodophor impregnated Incise drape Sterile. 60x45cm
IV Decanters 8.5 inch length, flexible tubing with clamp
IV infusion set with Flow regulator and micro drip chamber Burette with flow regulator
IV infusion set with Flow regulator with standard drip chamber
IV infusion set with inline filter
IV infusion set with Y-injection port
Jackson Rees (JR) circuit, Adult 180cm length, 2 liters capacity, corrugated flex tube
Jackson Rees (JR) circuit, Pediatric 100cm length, 0.5 liters capacity, corrugated flex tube
Left Heart Vent Catheter- 10Fr 15 inch length, malleable body, vented connector- SPR
Left Heart Vent Catheter- 13Fr 15 inch length, malleable body, vented connector- SPR
Left Heart Vent Catheter- 15Fr 15 inch length, malleable body, vented connector- SPR
Liga Clips, Large Compatible with the existing Liga clip Applicator.
Liga Clips, Small Compatible with the existing Liga clip Applicator.
Macrobore 4-way stopcock, 32"
Macrobore IV Extension Set, 8.5" With removable Clave connector, female luer lock adapter with wings, slide clamp, and rotating luer. Sterile
Macrobore IV Extension Set, bifurcated, 8" with 2 MicroClave connectors, 2 slide clamps and rotating male luer lock adapter.
Male cap or stoppers, non-vented
Male cap or stoppers, vented
MAX Activated Clotting Time tubes containing multiple particulate activators - kaolin, celite, and glass beads
Microbore IV Extension Set, 30"
Microbore IV Extension Set, 6" With removable Clave connector, female luer lock adapter with wings, slide clamp, and rotating luer
Microbore IV Extension Set, bifurcated, 6" With 2 MicroClave connectors, 2 slide clamps and rotating male luer lock adapter.
Mist blowing device (Mister blower) With fluid/gas mixing technology creating a consistent, predictable blood clearing mist. On/off control in hand-piece - Malleable shaft - Specialized nozzle, utilizing a micro-orifice for fluid delivery and a separate orifice for gas delivery - SPR
Mitral Valve Annuloplasty Ring - Complete, semi-rigid ring All sizes (23/24mm-36/37mm), Should be supplied with suitable holder & sizer. Purchase will be made individually whenever necessary - S.O.S.on consignment basis
Multiple perfusion adapter set with 4 legs (3 long +1 short leg) with individual tubing clamps for simultaneous perfusion of venous grafts and aortic root - with female luer inlet & male luer outlets preferably with length of at least 10". SPR.
Normal Saline- 0.45% 500ml bottle/bag
Normal Saline- 0.9% 500ml bottle/bag
Normal Saline- 3% 500ml bottle/bag
One-way stopcock with 10cm extension Sterile. Male luer lock at one end
One-way stopcock without extension Sterile.
Ophthalmic/Synthetic graft cautery sterile , disposable & battery operated for making perfect holes in the prosthetic vascular grafts
Pediatric Anesthetic Mask Size "0" Sterile
Pediatric Anesthetic Mask Size "00" Sterile
Pediatric Closed blood sampling system (VAMP) with needle-less cannula 6" sampling kit
Pericardial/Intracardiac Sump catheter without stainless steel spring, 15" in length, 20Fr in diameter- SPR
Peripheral IV Cannula (Venflon) with dual port, 18G Sterile. Disposable.
Peripheral IV Cannula (Venflon) with dual port, 20G Sterile. Disposable.
Peritoneal Dialysis Catheter set 16 Fr Pull-Apart Introducer Set. Set should include: 16 Fr Pull-Apart Sheath / Dilator, 18G Introducer Needle, 10 mL Syringe, J/Straight 0.038" guidewire, 15cm Catheter
Peritoneal dialysis fluid 1L, Adult
Peritoneal dialysis fluid 1L, Pediatric
Plasmalyte-A 500ml bag
Polyester (Dacron) double-valour, woven cardiovascular patch Collagen coated, 0.61-0.65mm thick, 10x10cm. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester (Dacron) Grafts- Straight Collagen impregnated, Straight, 18mm diameter, 60cm length. SPR
Polyester (Dacron) Grafts- Straight Collagen impregnated, Straight, 20mm diameter, 60cm length. SPR
Polyester (Dacron) Grafts- Straight Collagen impregnated, Straight, 22mm diameter, 60cm length. SPR
Polyester (Dacron) Grafts- Straight Collagen impregnated, Straight, 26mm diameter, 60cm length. SPR
Polyester (Dacron) Grafts- Straight Collagen impregnated, Straight, 28mm diameter, 60cm length. SPR
Polyester (Dacron) Grafts- Straight Collagen impregnated, Straight, 8mm diameter, 30cm length. SPR
Polyester (Dacron) patch Non-collagen coated, 10x10cm. SPR
Polyester No.2 (100cm,45mm,TC,1/2) Type of Needles: Taper cutting Needle Length: 45mm Needle Curvature: 1/2 circle Suture Length: 100cm Construction: Braided Needle: With Governing Specification: USP Category of suture: non absorbable Suture Material: Polyester
Polyester suture for Mitral valve pledgeted Type Of Needles: Taper Cut Double Armed, Pledgeted Needle Length: 26mm Needle Curvature: 1/2 circle Suture Length: 75cm Construction: Braided Needle: With Governing Specification: USP Category Of Suture: Non absorbable Suture Material: Polyester Colour: Alternating White or Green/blue
Polyester sutures for Aortic Valve, Pack of 10 Type Of Needles: Taper Cut Double Armed, Pledgeted Needle Length: 17mm Needle Curvature: 1/2 circle Suture Length: 75cm Construction: Braided Needle: With Governing Specification: USP Category Of Suture: Non absorbable Suture Material: Polyester Colour: Alternating White or Green/blue
Polyethylene half-gown Disposable. Non-transparent
Polyglactin 3-0(45cm,22mm,RC,3/8, antibacterial coated), Type Of Needles: Reverse Cutting Needle Length: 22mm Needle Curvature: 1/2 circle Suture Length: 45 Construction: Braided Needle: With Governing Specification: USP Category Of Suture: Absorbabale Suture Material: Polyglactin antibacterial coated
Polypropylene 3-0(70cm,26mm,TP,1/2) Type of Needles: Taper Point Double Armed Needle Length: 26mm Needle Curvature: 1/2 circle Suture Length: 70-75cm Construction: Monofilament Needle : With Governing Specification: USP category of suture: Non absorbable Suture Material: Polypropylene
Polypropylene 4-0(70cm,17mm,TP,1/2) Type of Needle: Taper Point Needle Length: 17mm Needle Curvature: 1/2 circle Suture Length: 70-75cm Construction: Monofilament Needle: With Governing Specification: USP Category Of Suture: Non absorbable Suture Material: Polypropylene
Polypropylene 4-0(70cm,22mm,TP,1/2) Type Of Needles: Taper Point Double Armed Needle Length: 22mm Needle Curvature: 1/2 circle Suture Length: 70-75cm Construction: Monofilament Needle: With Governing Specification: USP Category Of Suture: Non absorbable Suture Material: Polypropylene
Polypropylene 4-0(70cm,26mm,TP,1/2) Type Of Needles: Taper Point Double Armed Needle Length: 26mm Needle Curvature: 1/2 circle Suture Length: 70-75cm Construction: Monofilament Needle: With Governing Specification: USP Category Of Suture: Non absorbable Suture Material: Polypropylene
Polypropylene 5-0(70cm,17mm,TP,1/2) Type Of Needles: Taper Point Double Armed Needle Length: 17mm Needle Curvature: 1/2 circle Suture Length: 70-75cm Construction: Monofilament Needle: With Governing Specification: USP Category Of Suture: Non absorbable Suture Material: Polypropylene
Polypropylene 8-0 (60cm,8mm,RB, 3/8) Type Of Needles: Round Body Needle Length: 8mm Needle Curvature: 3/8 circle Suture Length: 60cm Construction: Monofilament Needle: With Governing Specification: USP Category Of Suture: Non absorbable Suture Material: Polypropylene
Polypropylene with Hemoseal Technology 5-0 (75cm,13mm,TP,1/2) Type Of Needles: Taper Point Needle Length: 13mm Needle Curvature: 1/2 circle Suture Length: 75cm Construction: Monofilament Needle: Thread Ratio: 1:1 Governing Specification: USP Category Of Suture: Non absorbable Suture Material: Polypropylene
Polypropylene with Hemoseal Technology 4-0 (90cm,17mm,TP, 1/2) Type Of Needles: Taper Point Needle Length: 17mm Needle Curvature: 1/2 circle Suture Length: 90cm Construction: Monofilament Needle: Thread Ratio: 1:1 Governing Specification: USP Category Of Suture: Non absorbable Suture Material: Polypropylene
Polypropylene with Hemoseal Technology 4-0 (90cm,26mm,TP,1/2) Type Of Needles: Taper Point Needle Length: 26mm Needle Curvature: 1/2 circle Suture Length: 90cm Construction: Monofilament Needle: Thread Ratio: 1:1 Governing Specification: USP Category Of Suture: Non absorbable Suture Material: Polypropylene
Polypropylene with Hemoseal Technology 5-0 (75cm,17mm,TP,1/2) Type Of Needles: Taper Point Needle Length: 17mm Needle Curvature: 1/2 circle Suture Length: 75cm Construction: Monofilament Needle: Thread Ratio: 1:1 Governing Specification: USP Category Of Suture: Non absorbable Suture Material: Polypropylene
Pressure tubing 100cm, Male-to-female Sterile. Disposable. Without stopcock
Pressure tubing 100cm, Male-to-male Sterile. Disposable. Without stopcock
Pressure tubing 200cm, Male-to-female Sterile. Disposable. Without stopcock
Pressure tubing 200cm, Male-to-male Sterile. Disposable. Without stopcock
Pro Seal Laryngeal Mask Airway with oesphageal vent, Size 3 Sterile
Pro Seal Laryngeal Mask Airway with oesphageal vent, Size 4 Sterile
Prosthetic Composite Aortic Valved Conduits with Mechanical valve All sizes (18/19mm- 26/27mm)- for Bentall operation. Should be incorporated with prosthetic bileaflet mechanical valve mounted on to collagen impregnated synthetic tube grafts. Should be supplied with valve holder, valve sizer & cauterizing loop for creating perforation in the graft. Purchase will be made individually whenever necessary - S.O.S. on consignment basis
PTFE Felt low-porosity, 1.85mm thick, 10x10cm. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
PTFE FELT pledgets Thickness x breadth & length : 1.65 mm x 4.8mm x 6 mm For vascular and cardiac sutures - Specify the number of pledgets in a pack and the rate of the pack clearly. SPR
Pulmonary Artery catheter introducer sheath, 8Fr Sterile. Disposable
Rapid Prime Sets (Large bore spikes attached to flexible tubing with a clamp) 16 inch length with open end. SPR
Rapid Prime Sets (Large bore spikes attached to flexible tubing with a clamp) 14 inch length with male leur at one end. SPR
Red rubber latex catheters - 10Fr for vessel snugging High quality and tension resistant body - at least 16" long overall. -SPR
Red rubber latex catheters - 8Fr for vessel snugging High quality and tension resistant body - at least 16" long overall. -SPR
Retrograde cardioplegia cannula (Coronary sinus) With Solid Stylet 15Fr -with auto-inflatable cuff & integral stop cock for pressure monitoring - Preferably wirewound body - SPR
Rigid coronary artery ostial cannula, 10Fr Sterile. 45° angled, basket tips- SPR
Rigid coronary artery ostial cannula, 10Fr Sterile. 90° angled, basket tips- SPR
Rigid coronary artery ostial cannula, 12Fr Sterile. 45° angled, basket tips- SPR
Rigid coronary artery ostial cannula, 12Fr Sterile. 90° angled, basket tips- SPR
Rigid coronary artery ostial cannula, 14Fr Sterile. 45° angled, basket tips- SPR
Rigid coronary artery ostial cannula, 14Fr Sterile. 90° angled, basket tips- SPR
Ringed ePTFE tube graft- Axillo-bifemoral branched graft Sterile. 8x8mm diameter, 70x40cm length.SPR
Ringed ePTFE tube graft, 8mmx40cm Sterile. Straight, 8mm, 40cm in length. SPR
Ringed ePTFE tube graft, 8mmx80cm Sterile. Straight, 8mm, 80cm in length. SPR
Ringer Lactate Sterile. 500ml bottle/bag
Silicone vessel (vascular) loop - Large size sterile medical grade radioopaque silicone loop 2 to 2.5 mm wide, < 1.2 mm thick & at least 40 cm long. for encircling the blood vessels during dissection. To be available in at least 3-4 colors (in each size) - preferably indiviual loop packed in a separate foil. The cost of a single loop will be taken for comparison purpose and hence the number of loops present in a single pack needs to be mentioned -SPR
Silicone vessel (vascular) loop - Small size sterile medical grade radioopaque silicone loop 1 to 1.3 mm wide, < 1 mm thick & at least 40 cm long. for encircling the blood vessels during dissection. To be available in at least 3-4 colors (in each size) - preferably indiviual loop packed in a separate foil. The cost of a single loop will be taken for comparison purpose and hence the number of loops present in a single pack needs to be mentioned -SPR
Stapler Cartridges/Reloads Compatible with the endoscopic powered stapler provided. Cartridges compatible with thoracic surgery should be made available. SPR
Sterile Polyethylene plain sheet, 100x60cm Disposable. Transparent. Taping at one end
Sterile Polyethylene plain sheet, 120x200cm Disposable. Non-transparent
Sterile Polyethylene plain sheet, 120x75cm Disposable. Non-transparent
Sterile, Disposable IV dressing for central intravascular lines with borders (Tegaderm), 9x11cm Waterproof film coating on all surfaces. Pre-printed documentation label for dressing changes. Breathable transparent film. Without absorbent pad. Flexible and conformable. SPR
Sterile, transparent film dressing (Tegaderm), 10x12cm Breathable and waterproof. Documentation label for dressing changes.Without absorbent pad. SPR
Straight connector for EtCO2 port
Swan Ganz catheter, 7Fr triple lumen, without cardiac output
Syringe 10cc with Luer lock
Syringe 20cc with Luer lock
Syringe 50cc with Luer lock
Temporary Epi-myocardial Pacing wire - Adult type at least 60 cm long for intraoperative placement during cardiac surgery- Incorporating a straight cutting needle of at least 60 mm long with ‘breakaway’ feature enabling the remaining butt to be used as a connecting plug to the Pace maker. The other end of the wire should have 25 to 27 mm tapercut 1/2 circle needle -SPR. 2 wires/pack
Temporary Epi-myocardial Pacing wire - Pediatric type at least 60 cm long for intraoperative placement during cardiac surgery- Incorporating a straight cutting needle of at least 60 mm long with ‘breakaway’ feature enabling the remaining butt to be used as a connecting plug to the Pace maker. The other end of the wire should have 16 to 18 mm tapercut 1/2 circle needle -SPR. 2 wires/pack
Three-way stopcock with 100cm extension Sterile. Disposable.
Tracheostomy Tubes, uncuffed 5.5mm Material of Tube (Non-toxic, Medical Grade): 100% PVC Obtulator with hole: Yes Pilot baloon with one way valve: Yes
Transparent (Silicone) Anesthesia Masks, size 4 Disposable, BPA and PVC free, Non-slip ridges and a flexible mask body, Non-scented
Transparent (Silicone) Anesthesia Masks, size 0 Disposable, BPA and PVC free, Non-slip ridges and a flexible mask body, Non-scented
Transparent (Silicone) Anesthesia Masks, size 1 Disposable, BPA and PVC free, Non-slip ridges and a flexible mask body, Non-scented
Transparent (Silicone) Anesthesia Masks, size 2 Disposable, BPA and PVC free, Non-slip ridges and a flexible mask body, Non-scented
Transparent (Silicone) Anesthesia Masks, size 3 Disposable, BPA and PVC free, Non-slip ridges and a flexible mask body, Non-scented
Transparent (Silicone) Anesthesia Masks, size 5 Disposable, BPA and PVC free, Non-slip ridges and a flexible mask body, Non-scented
Tricuspid Valve Annuloplasty Ring - Partial, Rigid ring All sizes (25/26mm-35/36mm)- Near anatomical contour with downward angle at septal end. Should be supplied with suitable holder & sizer. Purchase will be made individually whenever necessary - S.O.S.on consignment basis
Vascular tourniquet (Snugger) set, (6" long) for open heart surgery - color coded 4 tubes with one snare- for snugging the purse string sutures during open heart procedures - SPR
Vascular tourniquet (Snugger) set, (7" long) for open heart surgery- color coded 4 tubes with one snare- for snugging the purse string sutures during open heart procedures - SPR
Venous Return Cannula - single stage -- right angled metal 12Fr multiport tip with kink resistant wirewound body- tip orientation line overall length of at least 14 inch long - SPR
Venous Return Cannula - single stage -- right angled metal 14Fr multiport tip with kink resistant wirewound body- tip orientation line overall length of at least 14 inch long - SPR
Venous Return Cannula - single stage -- right angled metal 16Fr multiport tip with kink resistant wirewound body- tip orientation line overall length of at least 14 inch long - SPR
Venous Return Cannula - single stage -- right angled metal 18Fr multiport tip with kink resistant wirewound body- tip orientation line overall length of at least 14 inch long - SPR
Venous Return Cannula - single stage -- right angled metal 20Fr multiport tip with kink resistant wirewound body- tip orientation line overall length of at least 14 inch long - SPR
Venous Return Cannula - single stage -- right angled metal 22Fr multiport tip with kink resistant wirewound body- tip orientation line overall length of at least 14 inch long - SPR
Venous Return Cannula - single stage -- right angled metal 24Fr multiport tip with kink resistant wirewound body- tip orientation line overall length of at least 14 inch long - SPR
Venous Return Cannula - single stage -- right angled metal 26Fr multiport tip with kink resistant wirewound body- tip orientation line overall length of at least 14 inch long - SPR
Venous Return Cannula - single stage -- right angled metal 28Fr multiport tip with kink resistant wirewound body- tip orientation line overall length of at least 14 inch long - SPR
Venous Return Cannula - single stage -- straight 22Fr multiport tapered tip with kink resistant wirewound body- overall length of at least 12 inch long - SPR
Venous Return Cannula - single stage -- straight 24Fr multiport tapered tip with kink resistant wirewound body- overall length of at least 12 inch long - SPR
Venous Return Cannula - single stage -- straight 26Fr multiport tapered tip with kink resistant wirewound body- overall length of at least 12 inch long - SPR
Venous Return Cannula - single stage -- straight 28Fr multiport tapered tip with kink resistant wirewound body- overall length of at least 12 inch long - SPR
Venous Return Cannula - single stage -- straight 30Fr multiport tapered tip with kink resistant wirewound body- overall length of at least 12 inch long - SPR
Venous return cannula -Two Stage round body 34/46Fr - thin walled - with multi-ported tips & atrial basket - wirewound with depth markings with overall length of at least 38 cm - SPR
Vessel cannula - 2 mm tip with stepped contour - transparent body & a female luer at one end for checking the patency and leak in the harvested grafts - length about 5 cm. SPR
Vessel cannula - 3 mm tip with stepped contour - transparent body & a female luer at one end for checking the patency and leak in the harvested grafts - length about 5 cm. SPR
Viral barrier kit containing Medium Size Gown(1 no), Disposable Bag(1 no), Plain Sheet Large(2 no), Waterproof Legging(1 Pair), Cap(1 no), Mask(1 no), Paper Hand Towel, Nitrile Gloves (1 Pair), Goggle(1 no). Wrap around gown made of 50gsm SMS water resistant to 20cm of plain water, stitched, 3 ply mask, cap made of 15gsm spun bond, shoe cover leggings made of 50 micron polyethylene height up to below knee, Nitrile gloves one pair, polycarbonate goggles, plain sheets large 120x120 cm 2 nos. Disposable pouch one