Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.7 LAccepted-AOC NULL | 1 | Accepted-AOC L1 BIDDER | |
| 2 | 2₹1.8 L+₹7,080 (4.19%)Rejected-AOC | 2 | Rejected-AOC L2 | |
| 3 | 3₹1.9 L+₹24,921 (14.7%)Rejected-AOC 508 1ST FLOOR DR MUKHERJEE NAGAR DELHI 110009 | NORTH | DELHI | 110009 | 3 | Rejected-AOC L3 | |
| 4 | 4₹2.0 L+₹31,115 (18.4%)Rejected-AOC A 20 COMMERCIAL COMPLEX DR MUKHERJEE NAGAR KINGSWAY CAMP DELHI 110009 | NORTH | DELHI | 110009 | 4 | Rejected-AOC L4 |
Tender Value
₹2.0 L
EMD Value
₹4,000
Closing Date
21 Sept 2021, 10:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Ex. Engineer (Elect)/CSPZ
OFFICE OF THE EX. ENGINEER (ELECT)-I UNDER GROUND CAR PARKING ASAF ALI ROAD, DELHI-110002
Strengthning and renovation of electrical work 1st floor M and CW Center Sarak prem Narayan in ward No. 87 N Bazar Sita Ram City S.P. Zone
2021_NDMC_88203_1
21/MWEEE-I/2021-22/TC/05
Open Tender
Electrical Works
Item Rate
30 days
CSPZ
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
₹4,000
30 Apr 2022
14 Sept 2021
22 Sept 2021
14 Sept 2021
21 Sept 2021
14 Sept 2021
120 days
Amount
Wiring for light point /fan point /exhaust fan point /call ball point with 1.5sq.mm FRLS PVC installed copper conductor single core cable in surface / recessed PVC conduit, with piano type switch phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5sq.mm. FRLS PVC installed copper conductor single core cable etc as required. Group C
Rewiring for light point /fan point /exhaust fan point /call ball point with 1.5sq.mm FRLS PVC insulated copper conductor single core cableas earth wire in existing surface/recessed steel/ pvc conduit i/c dismentaling as reqd. etc as required. Group C
Supplying & fixing metal box of 180mm X 100mm X 60mm deep(nominal size) on surface or recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6pin 5/6 &15/16 amps socket outlet and piano type switch, connection painting etc. as required
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 200 mm X 300 mm X 100 mm deep
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
-do- 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (A) 12 Way Double door
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep
Supplying and fixing 5amps,to 32 amps rating, 240 volts, "C" curve miniature circuit breaker suitable for inductive load of following pole in the existing MCB DB complete with connection testing and commissioning etc, as required. (A) Single Pole
Supply and fixing following rating, double pole, 240 volt, isolator in the existing MCB DB complete with connection, testing and commissioning etc. as required. (A) 63 Amp.
Laying of one number pvc insulated and PVC sheathed/ XLPE power cable of 1.1 kv grade of following size in the existing surface as required Upto 35 sq. mm (clamped with 1mm thick saddle)
Earthing with G.I. earth pipe 4.5 mtr long,40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
S/I/T/C of LED tube type luminaire 20 watt rating complete with extruded aluminium batten prewired with high efficient LEDs with the following : Total system wattage 20 watt +/- 5 % Luminous efficacy lumens/watt >=95 Power factor >=0.95
Supply and fixing of following piano type swich/ socket on the existing switch box/ cover including connection etc as required. 5/6amps switch
-do- 15/16 amps switch
-do- 3 pin 5/6 amps socket outlet
-do- 6 pin 15/16 amps socket outlet
Supply of size 48"(1200mm) 50 watt energy saver ISI mark BEE 5 star rating AC ceiling fans suitable for 230 volt 50 Hz AC supply complete with down rod of standard length (30 cm) canopy, blades without regulator.
Supply of 15'(380mm)sweep 1400 rpm heavy duty Exaust Fan complete with ring, blade etc as required. ISI marked.
Supply & Fixing of 400 mm wall fans complete with blades ,jaal workable on 220/240 V AC supply etc as reqd.
Supply of PVC/XLPE insulated PVC/XLPE sheathed Al. conductor armoured cable for working voltage up to 1.1 kv confirming to IS 7098(part-1) of following size 2 X10 sqmm
PRINCE ENTERPRISES
M. CHHIBBA & CO.
ARPIT ELECTRIC CO.
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .