Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.9 LAccepted-AOC HOUSE NO 8 589 BEHIND PHC HOSPITAL OLD BUS STAND KORBA KORBA CHHATTISGARH 495678 | 495678 | L1 | Accepted-AOC L1 | |
| 2 | L2₹18.2 L+₹24,263 (1.35%)Rejected-Finance MARYADA 111 SHIKARGARH KANHAIYA NAGAR JODHPUR 342001 | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-Finance REJECTED DUE TO L2 | |
| 3 | L3₹18.8 L+₹78,068 (4.34%)Rejected-Finance 10 SUBASH COLONY DEFENCE LAB ROAD RATANDA JODHPUR 342006 | JODHPUR | JODHPUR | RAJASTHAN | 342006 | L3 | Rejected-Finance REJECTED DUE TO L3 | |
| 4 | L4₹22.7 L+₹4.7 L (25.9%)Rejected-Finance | L4 | Rejected-Finance REJECTED DUE TO L4 | |
| 5 | Rejected-Technical INSIDE SIWANCHI GATE GORIYON KI GALI JODHPUR 342001 | JODHPUR | JODHPUR | RAJASTHAN | 342001 | - | Rejected-Technical OLD AND INVALID DOCUMENTS |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
19 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE SHIKARGARH
Military Engineer Services, Garrison Engineer, Shikargarh, Near ASC Supply Depot, Ratanada Jodhpur-342011
REPAIR AND CLEANING OF SEWAGE SYSTEM TO MH AND ADJOINING AREA UNDER GE SHIKARGARH JODHPUR
2021_MES_439238_2
8689/E8 05
Open Tender
Civil Works
Works
335 days
GE SHIKARGARH JODHPUR
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE SHIKARGARH
₹50,000
Yes
1 Jul 2021
4 Jun 2021
21 Jun 2021
4 Jun 2021
19 Jun 2021
5 Jun 2021
60 days
Amount
Cleaning/ taking out sludge/mud/silt from manhole and septic tanks of any size, depth and capacity by manually or mechanically in foul condition including dewatering septic tank and manholes when ever required including removing of sludge/muds/silt in a closed container vehicle to a distance outside MD land and or buried in pits by making necessary excavation for filling of sludge and covering by earth on top properly all as specified and directed by Engineer-in-charge Note:- Sludge/ muds/ silt including water shall be measured before taking out from manholes/ septic tank.
Taking out muddy/ sewage water from manholes, soakage pit/ septic tanks of any size, depth and capacity by using of mechanical sewage/ mud water disposal pump set and dispossed off muddy/ sewage water in a closed container vehicle to a distance outside MD land complete all as specified and directed by Engr-in-charge. Note:- All labour and T&P i.e. sewage water pump set, diesel, transportation of pump set from one place to other place, suction pipe, delivery pipe and manpower, prepair approach to working site/ point etc required for above work, shall be deemed included in unit rates quoted by the contractor and nothing extra shall be admissible on this account.
Cleaning of existing drain pipes upto & including 200mm dia at any depth by rodding manually/ mechanically as required at site from manhole and well finishing after cleaning including getting out sludge if any and liquid materials from connecting manholes deposited in lines removing the solid and sludge to any distance place outside the defence land at their own cost and refixing manhole covers etc, the cost of removal shall be included in the quoted rate complete all as specified and directed by Engr-in-charge.
.ditto all as per Item No. 03 but above 200mm dia up to and including 450mm dia of pipe complete all as specified and directed by Engr-in-charge.
Removing blockage including cleaning of SGSW /CI pipe upto and including 100 mm bore from kitchen/bath/wash hand basin/Urinal/ WC of any length upto gulley trap by rodding/choke remover manually or otherwise including removing & refixing of oval access door cover (up to 6.00mtr hight) complete all as specified and directed by Engr-in-charge.
.ditto all as per Item No. 05 but above 6.00mtr hight complete all as specified and directed by Engr-in-charge.
Removing blockage including cleaning of SGSW /CI pipe upto and including 100 mm bore in any length from gulley trap to 1st manhole by rodding /choke remover,manually or otherwise including removing & refixing manhole covers of 1st manhole complete all as specified and directed by Engr-in-charge.
Site clearance soft loose soil including clearing away all grass vegetation, saplings,shrubs, brushwood, undergrowth,roots,and trees not exceeding 30 cm in girth (measured at a height of one meter above ground level) and removing entire rubbish out side MOD land complete all as specified and directed by Engineer in charge.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in any type of soil all as specified & directed by Engineer-in-Charge
Excavation in trenches not exceeding 1.5m wide and exceeding 1.5m but not exceeding 3.00 m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in any type of soil all as specified & directed by Engineer-in-Charge
Demolition and breaking up drain pipes (Salt glazed ware, AC or reinforced concrete) of 150mm bore set in cement mortar including PCC in bed and haunching against side complete all as specified and directed by Engineer-in-charge. Note:- Excavation and earth work shall be measured and paid separately.
Demolition and breaking up drain pipes (Salt glazed ware, AC or reinforced concrete) of 200mm bore set in cement mortar including PCC in bed and haunching against side complete all as specified and directed by Engineer-in-charge. Note:- Excavation and earth work shall be measured and paid separately.
Demolition and breaking up drain pipes (Salt glazed ware, AC or reinforced concrete) of 300mm bore set in cement mortar including PCC in bed and haunching against side complete all as specified and directed by Engineer-in-charge. (Note :- Excavation and earth work shall be measured and paid separately.
M&L PCC 1:4:8 type D2 (using 40 mm graded crushed stone aggregate) as in foundation , filling and mass concerete complete all as specified & directed by Engineer in charge.
M&L PCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate as in benching/ channels of manholes etc complete all as specified and as directed by Engineer in charge.
M&L PCC 1:2:4 type B-1 (20mm graded crushed stone aggregate) as in coping including necessary form work complete all as specified and directed by Engineer in charge.
S&F 150 mm bore Salt glazed stone ware drain pipe laid in trenches and cement joint in cement mortar 1:1 complete all as specified and as directed by Engineer in charge.
S&F 150 mm bore Reinforced cement concrete pipes, one end socketed, class NP-2, laid in trenches and jointed complete all as specified and as directed by Engineer in charge.
M&L for Reinforced concrete pipes, 200mm bore, class NP-2, laid in trenches and jointed in cement mortar as specified complete with collars.
M&L for Reinforced concrete pipes, 300mm bore, class NP-2, laid in trenches and jointed in cement mortar as specified complete with collars.
M&L PCC 1:4:8 type D-2 (using 40 mm graded crused stone aggregate) as in bed to150 mm bore salt glazed stone ware drain pipe including packing under and haunching against the side of pipe after they are laid and tested complete all as specified and directed by Engineer in charge.
.-ditto- but 200mm dia
.-ditto- but 300mm dia
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm soft/loose soil.
Removing excavated material/soil not exeeding 50 meater and deposting where directed at a level n. exc 1.5 M above the starting point.
Demolition of cement reinforced concrete of any descreption and any position not otherwise specifically provided complete all as specified & directed by Engineer-in-charge.
M&L for precast cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate in landings, cover slabs for man holes etc; chullah hoods,chajjas,water troughs,shelves and similar articles with plain faces complete all as specified & directed by Engineer-in-charge.
M&L mild steel TMT bars 10mm dia & over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed by Engineer-in-Charge.
M&L Mild steel round bars 12 mm dia and over cut to length, bent to shape as in handle of RCC cover slab of manholes complete all as specified & directed by Engineer in charge.
Dismantling of brick work or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles built in cement mortar or cement lime mortar incl all quions etc complete all as specified and as directed.
M&L for squarred rubble walling Jodhpur type brought upto course well bonded, bedded and solidly hearts built in cement mortar 1:6 complete all as specified and as directed.
-ditto- all as item No 36 above, but, except stone.
Hammer dressing to face stone with maximum depression on face from a straight edge not exceeding 20 mm and dressing face beds and jointed as specified to square rubble walling jodhpur type regular to courses.
Taking down cement plaster on brick/ stone walls of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as specified.
Rendering 15mm thick in cement mortar (1:6) on any face of brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified.
M&L rendering/ plastering 15 mm thick in CM 1:4 on brick, stone or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. Note: - Locations for use of WPC shall be given by Engineer Incharge and WPC Shall be measured and paid for separately under respective item.
Preparation of new plastered surfaces of walls etc. & applying three coats of lime white wash on walls complete all as specified.
Plugging minor leakages of SGSW pipes 150 mm bore to 200 mm bore pipes by carefully detecting leakage, cleaning outer surface of pipes and plugging with cement mortar 1:2 and/ or PCC 1:2:4 Type B-1 incl rubber packing as required at site all as specified and as directed by Engineer-in-charge. Note:- Excavation, returning filling & removal of surplus soil shall be measured and paid for separately under serial item Nos 65 & 66 here-in-after.
Plugging minor leakages of RCC NP-2 pipes 300 mm bore pipes to 600 mm bore pipes by carefully detecting leakage, cleaning outer surface of pipes and and plugging with cement mortar 1:2 and/ or PCC 1:2:4 Type B-1 incl rubber packing as required at site all as specified and as directed by Engi neer-in-charge. Note:- Excavation, returning filling & removal of surplus soil shall be measured and paid for separately under serial item Nos 65 & 66 here-in-after.
Excavation over area in mud or liquid mud / sludge (including removing accumulated water nearby from leaking sewage piplines) not exceeding 1.50 m in depth and getting out in soft/loose soil and returning filling in soils etc after repairs of the pipe etc complete all as specified and as directed by Engineer-in-charge. (for repairing leaking sewage pipelines)
Excavation over area in mud or liquid mud / sludge (including removing accumulated water nearby from leaking sewage pipe lines) exceeding 1.50 m depth but not exceeding 3.00 m in depth and getting out in soft/loose soil and returning filling in soils etc after repairs of the pipe etc complete all as specified and as directed by Engineer-in-charge. (for repairing leaking sewage pipelines).
S&F in repair precast steel fibre reinforced concrete (SFRC) any colour 75-100mm thick manhole cover with frames (ISI marked) of overall covered area not exceeding 3.00Sqm with clear opening not less than 0.36 Sqm, any shape (round, square, rectangular etc;) provided with suitable mild steel rims to prevent from chipping of edges and enable clear opening with provision of easy lifting hooks which are duly protected against corrosion laid over and including 10mm thick rendering in CM 1:4 complete all as specified and directed.
M&L for Jodhpur stone patti slabs, self faced 7.50mm to 10cm thick, 25cm to 35cm wide, laid dry as in manhole coveres, sizes as directed by Engineer incharge complete all as specified and as directed.
Note :-(i) The contractor or his represantative will report in complaint cell to receive the complaints in the morning by 0900hrs with necessary daily stores and are required to attend day to day complaints (ii) The complaints should be attended/ completed within 48hours after receiving the complaint slip failing which penalty of Rs. 500/- will be recovered for each complaint per day from the contractor payment. (iii) The cost of masson, plumber & carpenter should be deemed to be included in the item rates quoted by the contractor nothing will be paid extra for hiring the skilled labour. (iv) All safety measures will be provided by contractor during the working period. If any accident occurs, then the contractor will be solely responsible. (v) Work place in this subject cantract is at more than one story building and if any scaffolding is required no extra payment shall be made to contractor.
M/S KAUTILYA GARG
Panwar Electricals
Shri Ram Traders Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .