| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹2.0 CrAccepted-AOC AGHAPUR RAMPUR UTTAR PRADESH 244901 | RAMPUR | UTTAR PRADESH | 244901 | ₹2.0 Cr | L-1 | Accepted-AOC Work Awarded |
| 2 | L-2₹2.3 Cr+₹22.9 L (11.3%)Rejected-Finance 128 37 S BLOCK YASHODA NAGAR KANPUR U P | FATEHPUR | UTTAR PRADESH | 208001 | ₹2.3 Cr+₹22.9 L (11.3%) | L-2 | Rejected-Finance Due to higher rate |
| 3 | L-3₹2.8 Cr+₹79.2 L (39.0%)Rejected-Finance | ₹2.8 Cr+₹79.2 L (39.0%) | L-3 | Rejected-Finance Due to higher rate |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Others-Earnest Money FDR not submitted |
Tender Value
Refer Docs
EMD Value
₹4.2 L
Closing Date
9 Apr 2025, 12:00 pmClosed
Superintending Engineer
Electricity Distribution Circle, Rudrapur
Replacement of LT bare conductor by LT ABC at various places in 11 KV Lalpur-II Feeder emanating from 33/11 KV S/s Lalpur under EDD, Kichha on Turnkey Basis under the head of Capital (S.I.)
2025_UPCL3_81845_1
EDC(USN)48/2024-25
Open Tender
Electrical Works
Turn-key
180 days
Lalpur
Pl. refer tender documents
4 documents required · 4 mandatory
₹11,800
EE ETD Rudrapur
₹4.2 L
2 Aug 2025
24 Mar 2025
11 Apr 2025
24 Mar 2025
9 Apr 2025
25 Mar 2025
Amount
Annexure-A (LABOUR CHARGES)
Earthing of support with M.S. Earth rod of 2.5 meter long by hammaring of M.S. Rod to proper depth and connecting the earth electrode with the help of G.I. wire as per construction manual.
Excavation of earth for stay pit of size 0.6x0.6x1.2 mtr in all types of soil including proper dressing of sides and ramming of bottom including getting out the excavated soil and disposal of surplus excavated soil as directed complete work
Fixing, tightening and nozzling of stay with pole and stay rod on required tension as per drawing/manual in LT line
Grouting of Stay in size 0.6x0.6x0.3 in CC ratio 1:4:8 (1 cement : 4 graded stone 20mm nominal size : 8 coarse sand) block including cost of Cement, sand and stone ballast back filling of soil and boulders in pit and ramming and proper alignment, leveling as per RESSPO Manual.
Excavation of earth for pole pit of size 0.9x0.6x1/6 of full length of pole for erection of pole in all types of soil including proper dressing of sides and ramming of bottom including etting out the excavated soil and disposal of surplus excavated soil as directed complete work
Erection of PCC single support pole in proper level and alignment along with fixing of all accessories like top channel & clamps as per RESPO manual
Grouting of pole in size 0.45x4.45x1/9 of the support in CC ratio 1:4:8(1 cement:4 graded stone 20 mm niminal size: 8 coarse sand) block including cost of cement, sand and stone ballast back filling of soil and boulders in pit and ramming and proper alignment, levelling as per RESPO cnstruction manual
Muffing of poles size 0.45x0.60 cm radius with 1:3:6(1 cement:3 coarse sand :graded stone 10 mm nominal size) block size 45 cm height from ground level including cost of cement,stone and sand etc.
Dismantling of existing LT line. (1 Phase 2 Wire) including disc fitting, Insulator, clamps, Nut & Bolts and consumer connections and Street light connections etc. including rolling of conductor and cartage back from site to JE store(ACSR Weasel)
Dismantling of existing LT line. (2 Phase 3 Wire) including disc fitting, Insulator, clamps, Nut & Bolts and consumer connections and Street light connections etc. including rolling of conductor and cartage back from site to JE store(ACSR Weasel)
Dismantling of existing LT line. (3 Phase 4 Wire) including disc fitting, Insulator, clamps, Nut & Bolts and consumer connections and Street light connections etc. including rolling of conductor and cartage back from site to JE store(ACSR Weasel)
Painting of SP-55 pole with angle and channel and all steel part by one coat of Red Oxide Primer and two coats of aluminium Paint and two strip of fluorescent altemate Red and White paint 30 Cm wide upto 1.5 Mtrs. From ground level.
Disconnection and Reconnection of Consumer Connection.
Laying Sagging of LT XLPE AB CABLE 3x120+ 1x95+1x16 Sq.mm
Straightning of Tilted STP Poles
Supply and Fixing of LT Clamp for PCC Pole with N&B
Erection of Dead End Clamp
Erection of Suspension Clamp
Providing and fixing three phase distribution box with clamp
Fixing of Piercing Connector 120-35 sqmm
Fixing of PG Clamp 95-95 sqmm
Annexure-B (SUPPLY ITEMS)
Supply of PCC Pole 8.5 Mtr long
Supply of Earthing Rod MS 20x2500mm
Supply of GI wire 5mm/6 SWG
Supply of Stay set GI 16x1800 mm
Supply of stay wire GI 7/3.15mm 7/10 SWG.
Supply of Suspension clamp with Eye Hook.
Supply of Dead End Clamp with I Hook.
Supply of Stay Insulator.
Supply of MS Clamp with N&B for Suspension Clamp.
Supply of MS Clamp with N&B for PCC Dead End Clamp.
Supply of Stay Clamp with N&B.
Supply of PG Clamp.
Supply of Share head type Insulated piercing connector body molded from high quality mechanical climate and UV resistant glass reinforced polyamide, hot dipped galvanized bolts & contact teeth ABC size 120-70/35-35 sqmm to 25 Sqmm
Supply of LT AB cable 3x120+1x95+1x16 sqmm-D
Supply of SMC Three Phase L.T. Distribution Box with inbuilt panal lock, Al bus bar RYB 25x6mm., Al Busbar N. 40x6mm. for connection of L.T. consumer (Sintex make or other ISI mark reputed company ) with Panel Lock with key) (As per drawing attached)
Supply of MS Half Clamp for LT Distribution Box
DHRUV ENTERPRISES (BID ID -371857)
SRV TECHNO ENGINEERING PVT LTD (BID ID -372533)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .