| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.1 LAccepted-AOC G 16 JAY COMPLEX BELOW UMA CO OP BANK NIZAMPURA VADODARA GUJARAT 390002 | VADODARA | VADODARA | GUJARAT | 390002 | ₹21.1 L Quoted ₹21.3 L | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹22.9 L+₹1.5 L (7.23%)Rejected-Finance GANDHI NAGARI AIRPORT ROAD BHUJ KUTCH PIN 370 001 GUJARAT | KACHCHH | GUJARAT | 370001 | ₹22.9 L+₹1.5 L (7.23%) | L2 | Rejected-Finance BEING L2 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
31 Jul 2023, 6:00 pmClosed
GE AF BARODA
GE AF BARODA PO DARJIPURA BARODA 390022
REPAIR TO ROOF TREATMENT, FALSE CEILING AND MISC WORK AT MAKARPURA AT AFS BARODA
2023_MES_607031_1
8816/E8
Open Tender
Civil Works
Item Rate
270 days
GE AF BARODA
AS PER TENDER DOCUMENTS AND NIT
3 documents required · 3 mandatory
₹500
GE AF BARODA
₹50,000
Yes
4 Nov 2023
30 Jun 2023
7 Aug 2023
30 Jun 2023
31 Jul 2023
18 Jul 2023
1 Jul 2023 - 7 Jul 2023
Amount
M&L for taking down existing water proofing treatment (WPT) of any description from roof surfaces alongwith tiles if any incl dismantling of existing PCC/plaster surfaces and roughening of concrete surfaces cleaning and wahsing down the surfaces with water and removing rubbish to out side MD land complete all as specified and directed Note :- Felts and cement plaster/PCC/ tiles etc shall be measured as one layer only.
Material and Labour Rendering/ bedding layer of mortar 10mm thick in CM 1:3 on brick or concrete surfaces mixed with integral water proofing compound as per manufactures instruction while the concrete is green complete all as specified and directed Note:- WPC shall be measured & paid seperately.
M&L for applying cold bituminous primer @ 0.30 ltr/Sqm confirming to IS-3384 and laying APP polymer modified fiber glass reinforced membrane 3mm thick weight not less than 3.5kg/sqm (modified bituminous water proofing membrane ) with plain finish with polyester base reinforcement, sealing all over with lap of 100mm in length side and 150mm on width side of membrane by torching the same and including applying a coat of bituminous aluminium paint @ 100 gms/sqm all as per manufacturer instructions complete all as specified and directed .
Note:- (a) Rate quoted deemed to be inclusive of cleaning of surface to be treated properly to receive the primer and all as directed by the Engr-in-Charge. (b) Necessary guarantee certificate shall be given by contractor for 10 years from the date of completion of work. (c) APP membrane treatment shall be done firstly at corners and junction of parapet wall 30cm on verticle position and 30cm on horizontal position shall be done with proper attention and work carried out by authorised applicator only. Main portion of roof treatment shall be commenced only on completion of corners/ edges/ junctions. (d) APP membrane shall be taken upto outside of the parapet wall to an extent of 150mm minimum. (e) Ensure while laying the treatment no bulging on surface/voids shall be found and proper care/attention be given for the treatment. (f) If any work executed at site without any authorised applicator, the same shall be rejected and no payment shall be made. (g) Contractor shall produce the certificate from the manufacturer for the authorised applicator before commencement of work.
M&L for cement concrete type B-0 1:2:4 (using 12.5mm graded stone aggregate) (in roof slabs) laid to slope 1:30 in padding for WPT over roof slab complete all as specifed and as directed.
Supply only Integral waterproofing compound complete all as specified and directed
Demolition of cement concrete (reinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) complete all as specified and directed
M&L for providing cement concrete type B-0 1:2:4 (using 12.5mm graded stone aggregate) in cover fillets at junction of roof slabs and parapets wall, RCC chajja coping and similar work as directed with using WPC complete all as specified and directed. Note : WPC will be measured and paid separatly
Disconnecting existing water tanks (PVC/RCC) exc 250 ltr & n.exc 500 ltr capacity, setting aside (or lowring if required ) for repairs, cleaning etc and hoisting if required, reconnecting and refixing including cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc complete all as specified and directed.
Disconnecting existing water tanks (PC/RCC) exc 500 ltr & n.exc 1000 ltr capacity, setting aside (or lowring if required ) for repairs, cleaning etc and hoisting if required, reconnecting and refixing including cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc. complete all as specified and directed.
Demolition of brickwork or stone/boulder masonry built in cement mortar incl all quoins, arches pillars etc but excluding ashlar facings complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tanks 500 ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position including taking down the existing one complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tanks 1000 ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position including taking down the existing one complete all as specified and directed.
M&L for pre-cast cement concrete block type C-1, 1:3:6 (20mm graded aggregate) masonary with solid blocks, exc 10cm in width and setting in mortar 1:6 complete all as specified and directed.
M&L for renderting 15mm thick on other than fair faces of brick work or stone surfaces in CM 1:4, finished even and smooth without using extra cement complete all as specified and directed.
Taking up or down 15mm bore steel tubing and connections, including cleaning for re-fixing or removal to store complete all as specified and directed.
Taking up or down 20mm bore steel tubing and connections, including cleaning for re-fixing or removal to store complete all as specified and directed
Taking up or down 25mm bore steel tubing and connections, including cleaning for re-fixing or removal to store complete all as specified and directed
Refixing old steel tubing 15mm bore and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and directed
Refixing old steel tubing 20mm bore and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and directed
Refixing old steel tubing 25mm bore and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and directed
S&F 15mm bore Tubes,'Medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F 20mm bore Tubes,'Medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F 25mm bore Tubes,'Medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F (in repair) 20mm size Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm - 210gms) and fixed complete all as specified and directed
S&F (in repair) 25mm size Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 25mm-455gms) and fixed complete all as specified and directed
S&F (in repair) 20 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F (in repair) 25 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repair 20mm GI Nipple suitable for HDPE water tank. (Minimum weight 20mm - 45gms ) complete all as specified and directed
S&F in repair 25mm GI Nipple suitable for HDPE water tank. (Minimum weight 25mm- 65gms) complete all as specified and directed
M&L for complete removal of existing treatment by scraping down completely on brick walls/stone walls/concrete surfaces plastered or unplastered thoroughly, rubbing down, washing with water to the entire satisfaction of Engineer-in-Charge and applying two coats of Cement Base Paint camouflage pattern (Colour or shade as approved by GE) over and including alkali resistant priming coat as per manufacturers instruction complete on wall upto 4th floor including necessary scaffolding as required cleaning window glasses, joinery, electric fittings, wiring etc of drops and splashes and cleaning premise clean and tidy complete all as specified and directed
M&L, Preparation of old plastered ceiling surfaces and applying two coats of white wash complete all as specified and directed
M & L for framed work such as grills, gratings etc with ends shouldered and or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balustere, walk ways, railings, framework of water tanks and similar work including pintle hinges, stops, hand made sliding botl etc including ornametal and intricate design conforming to Fe-290, Gde-E-165 complete all as specified and directed
M & L for preparation of new surfaces of steel or iron over 10cm width or girth and applying two coats of synthetic enamel paint over and including a coat of red oxide zinc chrome primer complete all as specified and directed
S & F mild steel 4mm dia galvanised steel wire, 150x 100mm mesh, made up into mattresses or cages, lapped, wired and laid in position including closing after filling complete all as specified and directed
Dimantling plain or corrugated steel sheeting any gauge, thickness including Nainital or similar pattern roof coverings complete all as specified and directed
S & F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed
S & F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed
OM SREE MAHADEV TRADERS
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .