EE JSD Ghumarwin
EE JSD Ghumarwin
SH Laying jointing in trenches and testing of rising main and supply and errection of submersible pumping machinery Job No 2
2020_HPIPH_40546_1
GMR-BLP02-737(5544-94)
Open Tender
Civil Works
Item Rate
180 days
Bharari
Please refer Tender documents.
7 documents required · 7 mandatory
₹250
Yes
EE JSD Ghumarwin
₹16,849
Yes
2 Dec 2020
10 Sept 2020
18 Sept 2020
10 Sept 2020
17 Sept 2020
10 Sept 2020
10 Sept 2020 - 17 Sept 2020
Amount
Rising main:-Excavation in foundation and trenches etc. ( for pipe and pits) up to all depths and in all kinds of soils such as pick work, pick jumper work, saturated soil including bailing or pumping out of water, blasting in soft/ hard rock, chiseling/wedging out of rock where blasting is prohibited, in all leads and lifts including trimming and dressing of sides, leveling of beds to correct grade including shoring, strutting, planking timbering , stacking usable and unusable materials/ soils separately and after laying, jointing and testing of pipes, returning the usable soils in 15 cm layers by ramming and watering and then disposing of all surplus excavated soil / unusable materials as directed within all leads and lifts including restoration of un-metalled surfaces to its original condition and including cost of diversion of traffic, night signal boards, fixing caution boards, crossing over trenches for access to houses, fencing etc. complete in all respects within all leads and lifts as per the direction of the Engineer-in-charge. PICK JUMPER WORK 50% EACH
Pick Jumper work
Pick work
Laying, jointing and testing in trenches double flanged G.I. pipe 150 mm (MC)as per IS 1239-1990, dia of pipe as specified below Including providing, welding/ fixing M.S.flange including required number of nuts & bolt cnforming to IS 6392-1971 as per table specified below and providing & fixing asbestos gasket of appropriate thickness but not less than 3mm thick complete in all respect and to the entire satisfaction of the Engineer-in-Charge . including cutting the threaded portion of pipe,in all leads and lifts complete as per the direction and to the entire satisfaction of the Engineer-in-Charge.(earth work in trenches to be measured and paid for seprately)..
GI pipe 150 mm dia Medium Class with wall thickness 4.80 mm flang table 17
Dismentaling of existing GI pipe line of various dia meter complete with in all leads and lifts (earth work in trenches to be measured and paid separately)
GI pipe 150 mm dia Medium Class with wall thickness 4.80 mm Table 17
Re-Laying, jointing and testing in trenches double flanged G.I. pipe as per IS 1239-1990, dia of pipe as specified below Including providing, welding/ fixing M.S.flange including required number of nuts & bolt cnforming to IS 6392-1971 as per table specified below and providing & fixing asbestos gasket of appropriate thickness but not less than 3mm thick complete in all respect and to the entire satisfaction of the Engineer-in-Charge . including cutting the threaded portion of pipe,in all leads and lifts complete as per the direction and to the entire satisfaction of the Engineer-in-Charge.(earth work in trenches to be measured and paid for seprately)..
GI pipe 150 mm dia Medium Class with wall thickness 4.80 mm Table 17
PUMPING MACHINERY BOOSTER STAGE Providing & Installation of submersible pumping set of KSB/Kirloskar/ Calma/ Johnsion/ Oswal make comprising to latest relevant code. The pump should be fitted with bronze impellers of suitable alloys as per IS 8034-1976 latest suitable for clear water having greased packed bearings and shaft with wound stator on motor side with soft protection sleev on pump side ensuring better life for shaft of steel grade EN-8 coupled to a submersible squirrel cage electric induction motor (water proof type of required HP,RPM 2900 of standard make such as Kirloskar/Crompton/ BHEL confirming to BIS 9238-1979 latest with up to date amendments , totally dust and water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed lubricated bearings and provided with stainless steel thrust bearing plate to with stand non vertical loads with minimum wear and tear. It also should be fitted with a device to take up the expansion of water with heating of motor . The pump set should include water level gaurds, erection clamps, cable clips and depth gauge etc. and suitable for operation on data given below:- A) SITE CONDITIONS:- Location of site :- Seer Khad near Barog Quality of water :- Clear water and turbidity less than 50 ppm Source:- S/well in right bank of Seer khad .B) OPERATING CONDITIONS: AC Three phase current , 50 HZ operating frequency, 400 (+/-) rated voltage , double earthing system if required, speed of revolution, direction of rotation to be specified by the bidder, 20 hours , working hours per day , temperature of place specified up to 45 degree centigrade. C)MOTOR BIS code BIS:- 9283-1979 with up to date amendments , Enclosure of motor as per BIS 4691-1985 (latest), continuous duty, Insulation class B. DETAIL OF SHAFT EXTENSION REQUIRED:- Break way torque to be given by he tenderer, but starting current should not exceed 2.5 times of the full load current. The motor should be able to withstand initial current of 2.5 times the rated current for two minutes without suffering damages or permanent deformations. D)PUMP The one set will work at a time and one set will act as stand bye , Two years normal maintenance as recommended by the manufacturer.E) Pump Operating Conditions:- 38.34 Metre Total Head, 35 Metre Static Head , 7.94 LPS or 28.58 cum per hour each pump discharge , 450 metre length of Rising Main 150 mm dia , - 15% to + 10% of total head limits of pump required to operate, Suction / delivery size of pump specified by the bidder, pump manufacturers certificate to be provided
Providing and Installation of suitablestar delta of MEI/Kilburn make starter confirming to BIS 8544 -1979 latest with upto date amendments for electric induction motor mounted on panel board with magnetic type over load release and dashpot, time lag, under voltage release with initial oil filing of suitable capacity. Starter i) Type ii) Make
Providing and fixing of M.S. sheet, steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm, duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories with all internal electric duly painted. The drawing of panel board shall be subject to approval of Engineer in charge
Providing and fixing of ICTP switches with HRC fuses of L&T/ Crompton /Havells make for required motor of suitable capacity as per IS: 4064-1978 with up to date amendments.
Providing and fixing of Bus bar chamber having 3 core copper bars of suitable rating for full length of three phase and one bar of half the rating of full length for neutral confirming to BIS 8064-1976 and 11353-1985 read with 5578-1985- latest with up to date ammendments .
Providing and fixing of MCB of Havell/MDS/ Kilburn Jyoti make of suitable capacity on incoming feeder with initial oil filling as per IS: 2516-1985 latest with up to date amendments with neutral linked under voltage release.
Providing and fixing Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 ( P-I&II) with up to date amendments of 15 watts.
Providing and fixing 50 mm dial hour run metre of CEE/NEE make of suitable range as per relevant BIS specifications.
Providing and fixing double flanged Cast iron sluice valve of Leader/Kirloskar/KSB make class PN 1.00 of 125 mm diametre and capable of withstanding the normal seat pressure of 10.20 Kg/cm2 as per IS: 14846 with up to date amendments. Head including water hammer effect = 38.34 metre.
Providing and fixing double flanged Cast iron swing check type reflux valve 150 mm dia of Leader/Kirloskar/KSB make class PN 1.0 and capable of withstanding the normal seat pressure of 10.20 Kg/cm2 as per BIS: 5312-1984 Part I with up to date amendments.
Providing and laying copper PVC insulated armoured power 3.5 core cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of Siemens/ IEC/ICC/ make from metre of HPSEB to MCB and from MCB to bus bar switch and starter including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor. Supply side: 4.00 mm2 Motor side 4.00 mm2
Providing and fixing double flanged Cast iron swing check type reflux valve 125 mm dia of Leader/Kirloskar/KSB make class PN 1.0 and capable of withstanding the normal seat pressure of 10.20 Kg/cm2 as per BIS: 5312-1984 Part I with up to date amendments.
Providing and fixing of PVC joint less flat water proof cable as per BIS 694-1990 latest with up to date amendments suitable for the pump sets offered from MCB to motor including all other electrical equipments/ accessories such as thimbles, flexible pipe solder, nuts and bolts, cable glands etc. laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities & in case of non acceptance by HPSEB authorities same shall be replaced by the bidder.
Providing and Laying double loop earthing with GI wire & GI plate complete with material such as thimbles, nuts and bolts, charcoal and common salt, 25mmx3mm copper strips, digging of pits & G.I. wire as per IS: 3043-1987 with up to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect.
Providing and fixing 100 mm dia. circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0-16 Kg/cm2
Providing and laying delivery pipe 125 mm dia and common header 150 mm dia GMS tubes Medium class as per IS 1239- 1990 jointed with MS flanges of table 5 as per IS 6392-1971 up to a length of 20 metres including rappers, flanges, rubber gaskets, nuts and bolts bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications up to 5 metre away from the outer wall of pump houses. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated under item No.1.
Providing and fixing of floor/ wall mounted power factor shunt capacitor of L&T/Bajaj/Assian/Crompton make as per IS:2834-1986 with up to date amendments to raise the power factor at site to 0.95 for direct connections to induction motor individually of required 4.00 KVAR rating according to HP offered including cables as per relevant ISI code of Siemens/Gloster/IEC make) from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per IS: 4064-1978 with upto date amendments .
Ravinder Singh Patial
SUNIL KUMAR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .