Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.7 LAdmitted-Finance | -11.90% | ₹1.7 L | L1 | Admitted-Finance |
| 2 | L2₹2.0 LAdmitted-Finance HARIPAD VENDOR VIJAYAMMA HARIPAD 690 314 | 690314 | -0.01% | ₹2.0 L | L2 | Admitted-Finance |
| 3 | L3₹2.1 LAdmitted-Finance KERALA KL | +6.00% | ₹2.1 L | L3 | Admitted-Finance |
Tender Value
₹2.0 L
EMD Value
₹4,912
Closing Date
30 Jan 2026, 12:00 pmClosed
EXECUTIVE ENGINEER, ELECTRICAL DIVISION
EXECUTIVE ENGINEER OFFICE, ELECTRICAL DIVISION, TRAVANCORE DEVASWOM BOARD,CHENGANNUR
Ambalapuzha Sreekrishna Swamy Temple Urgent Electrical Maintenance of the Distribution Board and Associated Accessories General Electrical Work
2026_TDB_830731_1
TDB/EEE/ET-181/2025-26
Open Tender
Electrical Works
7 days
AMBALPPUZHA
Please refer Tender documents.
6 documents required · 6 mandatory
₹590
₹4,912
2 Feb 2026
27 Jan 2026
31 Jan 2026
27 Jan 2026
30 Jan 2026
27 Jan 2026
Ambalapuzha Devaswom in Ambalapuzha Group-Reg.
OD312368/2025-2026:Dismantling the existing PVC conduits ,switchboard, Distribution boards ,cables and all other accessories as required for the proper completion of the work and fixing the switch boards, distribution boards(single phase & three phase) in recess by cutting holes suitable sizes on wall and making good the damages etc. (concealing the cables and PVC conduit near the switch board and DBs). Wireman
OD312379/2025-2026:Dismantling the existing PVC conduits ,switchboard, Distribution boards ,cables and all other accessories as required for the proper completion of the work and fixing the switch boards, distribution boards(single phase & three phase) in recess by cutting holes suitable sizes on wall and making good the damages etc.(concealing the cables and PVC conduit near the switch board and DBs) Electrician.
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
2.17:Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32amps 415 volts "C" curve TP MCB complete with connections, testing and commissioning etc. as required.
9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
9.1.34:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.13.3:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.1.5:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.160 Amp TP&N
90.11.1.19:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
90.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
90.12.7.42:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp
2.2.13:Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel. making connections. etc. as required. 100 Amp, 30 KA 4 Pole
2.2.14:Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel. making connections. etc. as required. 125 Amp, 36 KA
OD314797/2025-2026:Supplying and fixing 100 A, 2 Way neutral link with all accessories including connections etc. as required.
OD314798/2025-2026:Supplying and fixing 100A HRC Fuse unit with all accessories including connections etc. as required.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.18 MB
PAGREEMENTFormat.pdf
Tender Documents • 0.12 MB
SPECIALCONDITIONSagreement.pdf
Tender Documents • 0.08 MB
approvedmaterials.pdf
Tender Documents • 0.51 MB
BOQ_1395568.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid