Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.1 CrAccepted-AOC 19 195 A 1 ATC BUILDING MOOLEPADAM NAGAR ROAD HMT JN KALAMASSERY P O KOCHI 683104 | KOCHI | ERNAKULAM | KERALA | 683104 | ₹3.1 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹3.3 Cr+₹22.1 L (7.19%)Rejected-AOC | ₹3.3 Cr+₹22.1 L (7.19%) | L2 | Rejected-AOC L2 |
Tender Value
₹3.1 Cr
EMD Value
₹50,000
Closing Date
15 Feb 2023, 5:00 pmClosed
Secretary
Munnar Grama Panchayat Office
As per tender Notice and BOQ
2023_DP_554795_1
100/2023
Open Tender
Miscellaneous Works
Supply and Service
90 days
Munnar Grama Panchayat
Agencies and institutions who have already succesfully completed work of a similar nature and for the amount of the Project and amount in excess of it
4 documents required · 4 mandatory
₹2,000
Yes
₹50,000
Yes
4 Apr 2023
3 Feb 2023
17 Feb 2023
3 Feb 2023
15 Feb 2023
3 Feb 2023
3 Feb 2023 - 15 Feb 2023
Amount
2.31 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of the girth up to 30 cm measured at height of 1.00 m above ground level and removal of rubbish up to distance of 50.00 m outside the periphery of the area cleared
2.6.1Earth work in excavation by mechanical means (Hydraulic Excavator) manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m. Disposed earth to be levelled and neatly dressed all kind of soil.
2.26.1Extra for every additional lift of 1.5m or part there of in excavation/ banking excavated or stacked materials. All kind of Soils
4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering- All work up to plinth level 1:4:8 (1 Cement : 4 Coarse sand : 8 graded stone aggregate 40 nominal size)
7.1.1 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand: 12 graded stone aggregate 20 mm nominal size), up to plinth level with cement mortar 1:6 (1 cement : 6 coarse sand)
6.4.1 Brickwork with common burnt clay FPS (non-modular) bricks of Class designation 7.5 in super structure above plinth level up to floor V level in all shapes and sizes in : cement mortar 1: 4 (1 cement : 4 coarse sand)
5.9.1 Centering and shuttering including strutting, etc. and removal of form for: Foundations, footing, bases of columns, etc for mass concrete
5.9.2 Centering and shuttering including strutting, etc. and removal of form for: Wall (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
5.9.3 Centering and shuttering including strutting, etc. and removal of form for: slab
5.37.1 Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C from transit mixer to site of laying, including the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS:9103 to accelerate/retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in–charge. Note-Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately. All work upto plinth level
5.37.2Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C from transit mixer to site of laying, including the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS:9103 to accelerate/retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in–charge. Note-Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately. All works above plinth level upto floor V level
5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars.
13.16.1 6 mm cement plaster of mix: 1:3 (1 cement: 3 fine sand)
13.37.1 White washing with lime to give an even shade : New work (three or more coats)
13.44.1 Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm)
13.47.1 Finishing walls with premium acrylic smooth exterior paint with silicon additives of required shade: new work (2 or more coats applied @ 1.43 L/10 m2 over and including priming coat of exterior primer applied @ 2.20 kg/ 10 m2.
4.12 Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification
12.47.1 Providing & fixing UV stabilised fibre glass reinforced plastic sheet rooting up to any pitch, including fixing with polymer coated 'J' or 'L' hooks, bolts & nuts 8 mm dia G.I plain/ bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovings incorporating minimum 0.3% ultra-violet stabiliser in resin system under approxirnately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866. The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified.2 mm thick corrugate 2.5"or 4.2" or 6") or step-down (2' or 3" or 6") as specified.
10.16.1 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes
10.25.1 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
19.16 Providing orange colour safety foot rest of minimum 6 mm thickplastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
11.37 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
8.31 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
11.41.1 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 500x500 mm
9.147C.1 Providing and fixing factory made uPVC white colour casement. Casement cum fixed glazed door comprising of uPVC multi- chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealent shall be paid separately). Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of door upto 2.00 sqm).
9.147A.4 Providing and fixing factory made uPVC white colour casement/ casement cum fixed glazed windows comprising of uPVC multi- chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Casement window single panel with S.S. friction hinges (300 x 19 x 1.9 mm), made of (small series) frame 47 x 50 mm & sash 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glass pane glazing bead of appropriate dimension. (Area of window upto 0.75 sqm.)
19.19.1.1 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality L D- 2.5 Rectangular shape 600x450 mm internal dimensions
Supplying, stacking and placing in position of stone Aggregate (Single size) : 06 mm nominal size
Supplying, stacking and placing in position Stone Aggregate (Single size) : 12.5 mm nominal size
Supplying, stacking and placing in position of Stone Aggregate (Single size): 20 mm nominal size
Supplying, stacking and placing in position of Gravel 1.5 mm to 2 mm
Bar Screen Supply, erection, testing and commissioning of 10 mm clear spacing SS 304 make as per technical specification
Raw Sewage Pump Sewage Pump Supply, erection, testing and commissioning of submersible cutter pump with CI Casing, including valves, pressure gauges etc & suitable for operation on 415±10% V, 3 Phase, 50 Hz, AC power supply, complete in all respects as required by the standard specifications complete with all accessories as per technical specification. Open impeller monoblock pump with flow rate 2.5 m3/h, 10 m head.
Air Blower Supply, erection, testing and commissioning of Twin type Rotary Air Blower (1W+1S) of free air at 50 mm Water Column &driven through “V” belt or directly coupled through flexible coupling to a TEFC motor, suitable for 415±10% volts, 3 phase, 50 Hz AC power supply, complete in all respects as required by the standard specifications complete with all accessories as per technical specification
Membrane Diffusers for aeration tank Supplying and fixing of retrievable type fine bubble diffusers of 63 mm dia and 1000 mm long complete with laterals and headers and complete in all respects as required by the standard specifications complete with all accessories as per technical specification Make: PP
MBBR Media for the aeration Tank: Supplying and keeping MBBR media in the aeration tank of make: polypropylene UV stabilized, effective surface area 400 m2/m3complete as per technical specification or as directed by Engineer in Charge Make: PP 22
Tube Settler media Supplying and keeping tube settler media with 600 mm vertical height Make: PP
Sludge Recirculation Pump(From Settling Tank to MBBR Tank and to Sludge Drying Bed) Supply, erection, testing and commissioning of self-priming non clogging type pumps with CI Casing, including valves, pressure gauges etc & suitable for operation on 415±10% V, 3 Phase, 50 Hz, AC power supply, complete in all respects as required by the standard specifications complete with all accessories as per technical specification.2.5 m3 /h @ 10 m head, 0.5 HP Self-priming Non clogging Type pumps
Filter feed Pump: Supply, erection, testing and commissioning of mono-block pumps with CI Casing, including valves, pressure gauges etc & suitable for operation on 415±10% V, 3 Phase, 50 Hz, AC power supply, complete in all respects as required by the standard specifications complete with all accessories as per technical specification. 3.125m3 /h @ 30 m head, 1.5 HP Monoblock Type pumps
Pressure Sand Filter Supply, erection, testing and commissioning of vertical self-supporting Pressure Sand filter inFRP vessels, operating pressure 10 kg/cm2, pressure gauges at inlet and outlet, sample cock, air vent valve with piping, CI butterfly valves and all accessories with backwash arrangement, with initial charge of filter media for sand filter, complete. 0.6 m dia @ 1.5m HOS Providing, fixing of vertical selfsupporting Pressure Sand filter Media: Silex sandand fine sand
Activated Carbon Filter: Supply, erection, testing and commissioning of vertical self-supporting Activated Carbon filter in FRP vessels, operating pressure 10 kg/cm2, pressure gauges at inlet and outlet, sample cock, air vent valve with piping, CI butterfly valves and all accessories with backwash arrangement, with initial charge of filter media for activated carbon filter, complete. 0.39 m dia @ 1.5m HOS Providing, fixing of vertical self supporting Activated Carbon Media: Silex sand and Activated Carbon
Hypodosing system Supply, erection, testing and commissioning as required by the standard specifications complete with all accessories as per technical specification. 0-4 lph pump, 100 L Tank
Flow Meter Supply, erection, testing and commissioning of electromagnetic flow meter with flow recorder, digital flow indicator, flow integrator with sensors, totalizer, transmittal and display arrangement and complete in all respects as required by the standard specifications complete with all accessories as per technical specifications to fix in the incoming pipeline to treated watertank
Level Switch Supply, erection, testing and commissioning, complete in all respects as required by the standard specifications complete with all accessories as per technical specification.
Anoxic media for the Anoxic tank Tank: Supplying and keeping Anoxic media in the aeration tank of make: polypropylene UV stabilized, effective surface area 400 m2/m3complete as per technical specification or as directed by Engineer in Charge Make: PP 22
Treated Water Pump (for treated water tank to Overhead water tank) Supply, erection, testing and commissioning of mono-block pump with CI Casing, including valves, pressure gauges etc & suitable for operation on 415±10% V, 3 Phase, 50 Hz, AC power supply, complete in all respects as required by the standard specifications complete with all accessories as per technical specification. 5.0 m3 /h @ 8 m head, 0.5 HP Self-priming
Sludge Transfer Pump Supply, erection, testing and commissioning of self-priming non clogging type pumps with CI Casing, including valves, pressure gauges etc & suitable for operation on 415±10% V, 3 Phase, 50 Hz, AC power supply, complete in all respects as required by the standard specifications complete with all accessories as per technical specification. 5.0 m3 /h @ 10 m head, 1.02 HP Self-priming Non clogging Type pumps
Supply & fixing of Honda- 12.5 KVA THREE PHASE DIESEL GENERATOR SET
50.18.9.9.1 Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2
50.18.9.22.1 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow
50.18.9.6.1 Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm dia 6 Kgf/cm2
Providing and fixing PVC moulded fittings / accessories for rigid PVC pipes, including jointing with PVC solvent cement – 50 mm dia Elbow
Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 50 x 50 x 50 mm Tee
Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 50 mm dia Socket/ coupler
Providing and fixing ball valve (PVC) of approved quality, high or low pressure, with plastic floats, complete 50 mm dia, Ball Valve
Providing and fixing G.I elbow of 80 mm
Providing and fixing G.I. pipes complete with G.I fittings including clamps. External work 80 mm dia nominal bore
Providing and fixing G.I pipes complete with G.I fittings and clamps; 50 mm nominal bore
Providing and fixing G.I pipes complete with G.I fittings and clamps; 110 mm nominal bore
50.18.9.22.5 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVC solvent cement 110x110x110 mm dia Tee
50.18.9.22.11 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Socket/ coupling
50.18.9.22.2 Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow
Supply & Wiring for light / power plug with 4x4 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit along with 2 Nos 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required, Supply & Wiring for light / power plug with 4x4 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit along with 2 Nos 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing.
Supply & Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required: 2x4 sq.mm + 1x4 sq.mm earth wire. Supply & Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed steel conduit as required 2x4 sq.mm + 1x4 sq.mm earth wire
Installation, Testing and Commissioning of EB Meter Board complete with all inter connections, with following switchgears and provision for fixing Three phase CT operated energymeter. 63A 4P 18KA MCCB - 1 No. 50A Bakelite fuse with HRC - 3 Nos. Neutral Link - 1 No. Installation, Testing and Commissioning of EB Meter Board complete with all inter connections, with 63A 4P 18KA MCCB, 50 A Bakelite fuse with HRC and neutral links and provision for fixing three phase CT operated energymeter.
Distribution Boards Supply, Installation, Testing and Commissioning of following double door MCB DB’s with necessary insulated tinned copper bus bars, interconnections, earthing and neutral terminal blocks, circuit name plate etc. DB’s shall be installed flush with the wall with necessary terminal boxes for the incoming /outgoing cables/conduits. 8 WAY TPN DB. Supply, Installation, Testing and Commissioning of 8 WAY TPN Distribution Box with necessary insulated tinned copper bus bars, interconnections, neutral terminal blocks, etc. installed flush with wall with terminal boxes for incoming/outgoing.
Distribution Boards Supply, Installation, Testing and Commissioning of following double door MCB DB’s with necessary insulated tinned copper bus bars, interconnections, earthing and neutral terminal blocks, circuit name plate etc. DB’s shall be installed flush with the wall with necessary terminal boxes for the incoming /outgoing cables/conduits. 25A 30mA 4P RCBO
Distribution Boards Supply, Installation, Testing and Commissioning of following double door MCB DB’s with necessary insulated tinned copper bus bars, interconnections, earthing and neutral terminal blocks, circuit name plate etc. DB’s shall be installed flush with the wall with necessary terminal boxes for the incoming /outgoing cables/conduits. MCB (C curve 10kA) - 6A SP MCB.
Distribution Boards Supply, Installation, Testing and Commissioning of following double door MCB DB’s with necessary insulated tinned copper bus bars, interconnections, earthing and neutral terminal blocks, circuit name plate etc. DB’s shall be installed flush with the wall with necessary terminal boxes for the incoming /outgoing cables/conduits. MCB (C curve 10kA) - 16A SP MCB
Supply & Laying, Testing & commissioning of XLPE insulated PVC sheathed 1.1kV grade Al. cables of size - 4C x 16 Sq.mm. The cable shall be laid in excavated trench/ built up trench/ existing cable tray /pulling through existing pipes/clamped on to the walls using necessary fixing accessories and identification tags.
Supply & Laying, Testing & commissioning of XLPE insulated PVC sheathed 1.1kV grade Al. cables of size - 4C x 10 Sq.mm. The cable shall be laid in excavated trench/ built up trench/ existing cable tray / pulling through existing pipes/clamped on to the walls using necessary fixing accessories and identification tags.
Supply & Laying, Testing & commissioning of XLPE insulated PVC sheathed 1.1kV grade Al. cables of size - 4C x 6 Sq.mm. The cable shall be laid in excavated trench/ built up trench/ existing cable tray / pulling through existing pipes/clamped on to the walls using necessary fixing accessories and identification tags.
Supply & Laying, Testing & commissioning of XLPE insulated PVC sheathed 1.1kV grade Al. cables of size - 3C x 6 Sq.mm. The cable shall be laid in excavated trench/ built up trench/ existing cable tray /pulling through existing pipes/clamped on to the walls using necessary fixing accessories and identification tags.
Supply & Laying, Testing & commissioning of XLPE insulated PVC sheathed 1.1kV grade Al. cables of size - 3C x 4 Sq.mm. The cable shall be laid in excavated trench/ built up trench/ existing cable tray /pulling through existing pipes/clamped on to the walls using necessary fixing accessories and identification tags.
Supply & Laying, Testing & commissioning of XLPE insulated PVC sheathed 1.1kV grade Cu. cables for the size - 3C x 2.5 Sq.mm. The cable shall be laid in excavated trench/ built up trench/ existing cable tray / pulling through existing pipes/clamped on to the walls using necessary fixing accessories and identification tags.
Supply & Laying, Testing & commissioning of XLPE insulated PVC sheathed 1.1kV grade Cu. cables for the size - 3C x 1.5 Sq.mm. The cable shall be laid in excavated trench/ built up trench/ existing cable tray / pulling through existing pipes/clamped on to the walls using necessary fixing accessories and identification tags.
Supply, Laying, Testing & commissioning of Cu. control cables of 10C x 1.5 Sq.mm
Supply & Installation and commissioning charges for carrying out cable end termination for the 4C x 16 Sq.mm cable using brass cable gland, compression type copper crimping lugs, gland earthing of adequate size etc., complete.
Supply & Installation and commissioning charges for carrying out cable end termination for the 4C x 10 Sq.mm cable using brass cable gland, compression type copper crimping lugs, gland earthing of adequate size etc., complete.
Supply & Installation and commissioning charges for carrying out cable end termination for the 4C x 6 Sq.mm cable using brass cable gland, compression type copper crimping lugs, gland earthing of adequate size etc., complete.
Supply & Installation and commissioning charges for carrying out cable end termination for the 3C x 6 Sq.mm cable using brass cable gland, compression type copper crimping lugs, gland earthing of adequate size etc., complete.
Supply & Installation and commissioning charges for carrying out cable end termination for the 3C x 2.5 Sq.mm XLPE Cu. cable using brass cable gland, compression type copper crimping lugs, gland earthing of adequate size etc., complete.
Supply & Installation and commissioning charges for carrying out cable end termination for the 3C x 1.5 Sq.mm XLPE Cu. cable using brass cable gland, compression type copper crimping lugs, gland earthing of adequate size etc., complete.
Supply & Labour charges for Providing pipe earth station with 4500mm long, 40mm Diameter G.I Pipe, earthing strips, clamps, funnel, terminal Electrodes etc., excavation in all classes of soil, filling with alternate layers of charcoal and salt and back filling, construction of Earthpit Inspection Chamber and Heavy-duty C.I. Chequered plate for Earthpit Inspection Chamber cover. The Earthing Station should conform to IS 3043/1987.
Supply & Installation & connecting of Cu. strip/wire (Copper wire No. 10 SWG) being clamped to walls, cable trays, ladders, run in pipes, laid underground etc., as required including interconnection between the earth stations etc. as per the general specifications and IS 3043/1987.
Supply & Installation & connecting of Cu. strip/wire (Copper wire No. 14 SWG) being clamped to walls, cable trays, ladders, run in pipes, laid underground etc., as required including interconnection between the earth stations etc. as per the general specifications and IS 3043/1987.
Supply & Installation of modular type 16A power switches & sockets with indicator in standard metal boxes concealed on wall and giving connections complete.
Supply & Installation of modular type 6A 5PIN power switches & sockets with indicator in standard metal boxes concealed on wall and giving connections complete.
Supply & Labour charges for, fixing, testing and commissioning wall light on the wall with all necessary ball and sockets, false ceiling protection accessory, rackets, down rods and 3-core flexible wires etc.
Supply & Labour charges for, fixing, testing and commissioning of the LED Tube light(4ft) on roof/truss/ceiling/wall with all necessary ball and sockets, false ceiling protection accessory, rackets, down rods and 3-core flexible wires etc.
Supply & Labour charges for, fixing, testing and commissioning of the Ceiling fan 1200mm Sweep on ceiling with all necessary ball and sockets, false ceiling protection accessory, rackets, down rods and 3-core flexible wires etc.
Supply and Labour charges fixing 4" Al pipe (including Al cladding) cladding upto 5 m of exhaust pipe including residential silencer complete for 20kVA, 415V, 50Hz Diesel Generating Set.
Supply & Installing of Ceiling Hook for Ceiling fans/Chandeliers
Supply & fixing of LT danger boards.
Labour charges for Installation, testing and commissioning of 20kVA, 415V, 50Hz Diesel Generating Set with acoustic enclosure with entire standard accessories and control panel and all related works including supply and fixing Al cladding upto 5Mtr of exhaust pipe, exhaust pipe including residential silencer complete. Rate shall also include doing foundation works of required size as insisted by the manufacturer.
Supply of Rubber gloves as per IS 4770
Supply of first aid box kit
Supply & Laying of 20 mm medium grade PVC conduits of ISI in recessed concrete, floors etc. with all necessary PVC accessories and rough plastering as required (for pulling cable/wires)
Supply & Laying of 25 mm medium grade PVC conduits of ISI in recessed concrete, floors etc. with all necessary PVC accessories and rough plastering as required (for pulling cable/wires)
PANEL BOARD Design, fabrication, erection, testing and commissioning of the following cubicle type dust and vermin proof free standing, floor mounting panel boards with top entry for cables and complete with all interconnections, powder coating, control wiring etc. as per approved drawings, IS, CEA Regulations and General conditions/ Technical specifications. MSB Incomer: (1) E.B side: 63A 4P MCB ISOLATOR-1 No 63A ,TP+N, AC-3 duty Contactor with electrical & mechanical interlock- 1Nos (a) Meters & Relays: Multifunction Energy meter with display of voltage, Current, Power, Frequency, Power Factor (b) RYB indication lamp LED type with protection gears- 1 set. (2) DG-1: 63A 4P MCB ISOLATOR-1 No 63A ,TP+N, AC-3 duty Contactor with electrical & mechanical interlock- 1Nos(a) Meters & Relays: Multifunction digital energy meter with display of voltage, Current, Power, Frequency & Power Factor (b) RYB indication lamp LED type with protection gears- 1 set. Microprocessor based AMF relay (Type: EC-2 PLUS of make-C&S) with all related accessories like auxiliary contacts, switchgears, control wiring etc. complete Outgoing: 25A 4P MCB -4Nos 16A TP MCB with 2 Nos of DOL starter for 2.0HP motor and on/off indication lamps with 25A 3 pole two-way rotary cam operated switch with centre off - 7 set 25A TP MCB with 2 Nos of star delta starter for 10.0HP motor and on/off indication lamps with 25A 3 pole two-way rotary cam operated switch with centre off - 2 sets 16A TP MCB with 2 Nos of star delta starter for 3.0HP motor and on/off indication lamps with 25A 3 pole two-way rotary cam operated switch with centre off - 1set 16A TP MCB with 2 Nos of star delta starter for 2.7HP motor and on/off indication lamps with 25A 3 pole two-way rotary cam operated switch with centre off - 1set Busbar:1 Set TPN AL bus bars suitably rated for 63A
Supply and Wiring for light point/ fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required
Supply, Installation and commissioning charges for carrying out cable end termination for the 3C x 4 Sq.mm cable using brass cable gland, compression type copper crimping lugs, gland earthing of adequate size etc., complete.
DOCUMENTS/APPROVAL Preparation of necessary documents and submitting to the Electrical Inspectorate and KSEB for getting service connections.
Fabricating, supplying and erection of 6 Mtrs long hot dip Galvanized Octagonal pole with BSEN 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 180kmph for 6 Mtrs pole having dimensions bottom 130mm, top 70mm with 3mm thick, 220mm x 220 x 12mm base plate and 4Nos of M20x600mm long J bolts along with template and with Single arm bracket including supply and fixing the LED lamp(65W) and giving connection using suitable size 3 core copper round cable etc. complete. The pole shall be galvanized with not less than 65micron etc.
Supply & Installation of 6mm thick M.S cable trays (150mm X 50mm) and other structural supports for cable, cable trays and other structural material not covered elsewhere including one coat of metal primer and two coats of Grey paint.
7.1.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Upto 35 sq. mm. Excavation, sand cushioning, protective covering and refilling for a depth of 1.1m and width 0.5m for the laying of XLPE insulated PVC sheathed 1.1kV grade Al. cables of size: 4C X 16 sq.mm
Supply and Laying of GI conduit pipe of size 2 inch for the laying of XLPE insulated PVC sheathed 1.1kV grade Al. cables of size 4C X 16 sq.mm
Fire protection (DRAWING , DOCUMENTATION & LAISIONING WORK)
PRASANTH.MG
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_815248.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .