Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.9 CrAccepted-AOC 1ST FLOOR KRISHNA TOWERS OPP TO THRIKKAKARA TEMPLE THRIKKAKARA P O COCHIN 682 021 | ERNAKULAM | KERALA | 682021 | ₹2.9 Cr | L1 | Accepted-AOC Lowest bid |
| 2 | L2₹2.9 Cr+₹1.2 L (0.42%)Rejected-Finance 801 VENUS BENECIA PAKVAN DINING LANE OPP RAJPATH CLUB S G HIGHWAY BODAKDEV AHMEDABAD 380053 | AHMADABAD | GUJARAT | 380053 | ₹2.9 Cr+₹1.2 L (0.42%) | L2 | Rejected-Finance Not the lowest bidder |
| 3 | L3₹3.1 Cr+₹22.5 L (7.90%)Rejected-Finance 11TH FLOOR ECO CENTRE BUSINESS TOWER P NO 4 EM BLOCK SECTOR V KOLKATA 91 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | ₹3.1 Cr+₹22.5 L (7.90%) | L3 | Rejected-Finance Not the lowest bidder |
| 4 | L4₹4.4 Cr+₹1.6 Cr (54.8%)Rejected-Finance | ₹4.4 Cr+₹1.6 Cr (54.8%) | L4 | Rejected-Finance Not the lowest bidder |
Tender Value
₹3.0 Cr
EMD Value
₹5.9 L
Closing Date
25 Jun 2024, 11:00 amClosed
Asst GM EE
Asst GM (Engg-Ele) AAI, Calicut International Airport, Calicut Airport PO, Malappuram - 673 647
Facility Management of E and M Installations of Terminal Buildings Technical Block Residential Colony Car Park Street Lights Water Supply Fire Fighting etc of Calicut International Airport during 2024_26
2024_AAI_196993_1
AAI/CL/EE/231/NIT-04/24-25
Open Tender
Electrical Works
Works
730 days
AAI Calicut Airport
Please refer Tender documents.
15 documents required · 15 mandatory
₹1,120
₹5.9 L
18 Jul 2025
3 Jun 2024
26 Jun 2024
4 Jun 2024
25 Jun 2024
4 Jun 2024
4 Jun 2024 - 11 Jun 2024
Amount
Operation and periodic maintenance of all Electrical and Mechanical installations at different buildings/installations of airport such as Terminal building, Residential Colony, Pump Houses including but not limited to: operation of pumps for water supply and firefighting, lift, escalator, switchgears, Carpark/street lighting including rectifying defects/faults/breakdowns on round the clock shifts, on all days including Sundays and Holidays including preparation & maintenance of PMI activities, updating of associated log books and records etc., complete as required.
Engaging of skilled labour for carrying out electrical works like wiring, conduiting, electrification and other miscellaneous electrical works as per instructions from Engineering in charge ( 1 man /day = 8 hours of work).
Engaging of unskilled labour for carrying out casual/unspecified works like clearing of site, shifting of inventory, and other miscellaneous works as per instructions from Engineering in charge ( 1 man/ day = 8 hours of work).
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. ( GROUP C)
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire.
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 4 sq. mm + 2 X 4 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 4 x 1.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 2.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 4 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 4 x 4 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 5 x 4 \sq.mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 6 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 4 x 6 sq. mm
Supplying and fixing of following sizes of PVC conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. - 20 mm
Supplying and fixing of following sizes of PVC conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. - 25 mm
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm)
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 3Module (100mmX75mm)
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 4 Module (125mmX75mm)
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 6 Module (200mmX75mm)
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 8 Module (125mmX125mm)
Supplying and fixing following size/ modules, plastic surface box along with modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm)
Supplying and fixing following size/ modules, plastic surface box along with modular base & cover plate for modular switches in recess etc. as required. 3 Module (100mmX75mm)
Supplying and fixing following size/ modules, plastic surface box along with modular base & cover plate for modular switches in recess etc. as required. 4 Module (125mmX75mm)
Supplying and fixing following size/ modules, plastic surface box along with modular base & cover plate for modular switches in recess etc. as required. 6 Module (200mmX75mm)
Supplying and fixing following size/ modules, plastic surface box along with modular base & cover plate for modular switches in recess etc. as required. 8 Module (125mmX125mm)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 amps switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 A socket
Supplying and fixing 32 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top along with 20 amps “C” curve, TPN MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 6 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing 6 A to 32 A rating, 240/415 V, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
Supplying and fixing 6 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Four Pole
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. .with charcoal/ coke and salt as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Repairing of earth pits by dismantling the existing masonry enclosure and providing RCC enclosure of 1:2:4 grade (1 cement : 2 coarse sand : 4 graded stone) and reinforced with steel rods 8mm dia in a pattern approved by AAI, providing hinged MS cover of minimum 8 mm thickness with suitable locking system as per specifications including, painting the earth pit portion above ground and cover plate, numbering the same, providing and fixing suitable funnel, removing of debris etc. as per the direction of EIC.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Up to 35 sq. mm (clamped with 1mm thick saddle)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Above 35 sq. mm and up to 95 sq. mm (clamped with 25x3mm MS flat clamp)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Up to 35 sq.mm (clamped with 1mm thick saddle)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Above 35 sq. mm and up to 95 sq. mm (clamped with 25x3mm MS flat clamp)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc. as required, but excluding sand cushioning and protective covering. Up to 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc. as required, but excluding sand cushioning and protective covering. Above 35 sq. mm and up to 95 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Up to 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 35 sq. mm and up to 95 sq. mm
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 16 sq. mm
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 25 sq. mm
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 35 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5 X 25 sq. mm (28mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5X 35 sq. mm (32mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5X 50 sq. mm (35mm)
Excavation of the cable trenches in hard rock not exceeding 1.5 metres in width and lift up to 1.5 metres, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 metres.
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 20 mm nominal size) including form work etc. as required.
Providing and laying in position cement concrete 1:3:6 (1 cement : 2 coarse sand : 6 graded stone aggregate 20 mm nominal size) including form work etc. as required.
Spray painting with two or more coat of synthetic PU enamel paint of approved brand, manufacturer and colour to give an even shade for distribution boards, Fire hydrant Pipes, Internal & External Electrical panels/ Junction boxes/feeder pillars, etc. provided in the Terminal Buildings, Technical Block and other Ancillary Buildings including cleaning the surface, applying two or more coats of primer wherever necessary, removing, shifting of installations from existing site to a suitable site for painting where ever required. Scope also includes re-lettering / new lettering of various distribution boards/ panels wherever required.
Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, depth up to 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m. (a) All kinds of soil for laying of pipes, cables etc., not exceeding 80 mm dia.
Cutting road/concrete including equipment, labour etc. and disposal of material as directed, within a lead of 50 m.
Hiring of crane of suitable capacity operating height of 30 meter (minimum) with working bucket, safety harness etc. for replacement of the steel wire rope of the 30.5 meter monumental National Flag Mast installed opposite to Terminal Building of the Calicut Intl. Airport. (Steel Rope and Labour for steel rope shall be provided by AAI.)
Hiring of crane of suitable capacity operating height of 30 meter (minimum) with working bucket, safety harness etc. for replacement of the aviation obstruction light of the 30.5 meter monumental National Flag Mast installed opposite to Terminal Building of the Calicut Intl. Airport. (Aviation Obstruction light and Labour shall be provided by AAI.)
Supply of Single Dome Integral LED Aviation Obstruction light comprising of aluminium housing with polycarbonate housing as per approved makes.
Supply and installation of AISI 316 Grade 6 mm SS steel wire ropes suitable for 30.5 m monumental flag mast installed in Calicut Airport. The job includes the supply and installation of 6 mm rope on the 30.5 mtr monumental flag mast. including replacement of stainless steel thimbles, copper splicing, galvanized turnbuckle eye and bull dog grips including using suitable equipments , tools , safety harness etc. complete as required for replacement of the wire rope complete as required. The job also includes removal of existing wire ropes from the high mast.
Extra for each Additional day of Illumination on one job of Item No.69
Replacing the drive end bearings of motor of following capacity and application including decoupling from the load side, dismantling from the foundation , loading , unloading transportation, labour charges, consumables, lubricants , tools , tackles , jigs and implements etc. complete as required including refixing, realignment, ensuring the design / required parameters etc. complete as required (Damaged Bearing need not be returned to AAI. Rate shall be quoted accordingly) a) 12.50 HP Jockey Pump
Replacing the drive end bearings of motor of following capacity and application including decoupling from the load side, dismantling from the foundation , loading , unloading transportation, labour charges, consumables, lubricants , tools , tackles , jigs and implements etc. complete as required including refixing, realignment, ensuring the design / required parameters etc. complete as required (Damaged Bearing need not be returned to AAI. Rate shall be quoted accordingly) b) 25.00 HP Jockey Pump
Replacing the drive end bearings of motor of following capacity and application including decoupling from the load side, dismantling from the foundation , loading , unloading transportation, labour charges, consumables, lubricants , tools , tackles , jigs and implements etc. complete as required including refixing, realignment, ensuring the design / required parameters etc. complete as required (Damaged Bearing need not be returned to AAI. Rate shall be quoted accordingly) c) 75.00 HP Main Fire Pump
Replacing the drive end bearings of motor of following capacity and application including decoupling from the load side, dismantling from the foundation , loading , unloading transportation, labour charges, consumables, lubricants , tools , tackles , jigs and implements etc. complete as required including refixing, realignment, ensuring the design / required parameters etc. complete as required (Damaged Bearing need not be returned to AAI. Rate shall be quoted accordingly) d) 120.00 HP Main Fire Pump
Replacing the non-drive end bearings of motor of following capacity and application including decoupling from the load side, dismantling from the foundation , loading , unloading transportation, labour charges, consumables, lubricants , tools , tackles , jigs and implements etc. complete as required including refixing, realignment, ensuring the design / required parameters etc. complete as required (Damaged Bearing need not be returned to AAI. Rate shall be quoted accordingly) a) 12.50 HP Jockey Pump
Replacing the non-drive end bearings of motor of following capacity and application including decoupling from the load side, dismantling from the foundation , loading , unloading transportation, labour charges, consumables, lubricants , tools , tackles , jigs and implements etc. complete as required including refixing, realignment, ensuring the design / required parameters etc. complete as required (Damaged Bearing need not be returned to AAI. Rate shall be quoted accordingly) b) 25.00 HP Jockey Pump
Replacing the non-drive end bearings of motor of following capacity and application including decoupling from the load side, dismantling from the foundation , loading , unloading transportation, labour charges, consumables, lubricants , tools , tackles , jigs and implements etc. complete as required including refixing, realignment, ensuring the design / required parameters etc. complete as required (Damaged Bearing need not be returned to AAI. Rate shall be quoted accordingly) c) 75.00 HP Main Fire Pump
Replacing the non-drive end bearings of motor of following capacity and application including decoupling from the load side, dismantling from the foundation , loading , unloading transportation, labour charges, consumables, lubricants , tools , tackles , jigs and implements etc. complete as required including refixing, realignment, ensuring the design / required parameters etc. complete as required (Damaged Bearing need not be returned to AAI. Rate shall be quoted accordingly) d) 120.00 HP Main Fire Pump
Replacing both the bearings of motor of following capacity and application including decoupling from the load side, dismantling from the foundation , loading , unloading transportation, labour charges, consumables, lubricants , tools , tackles , jigs and implements etc. complete as required including refixing, realignment, ensuring the design / required parameters etc. complete as required (Damaged Bearing need not be returned to AAI. Rate shall be quoted accordingly) a) 12.50 HP Jockey Pump
Replacing both the bearings of motor of following capacity and application including decoupling from the load side, dismantling from the foundation , loading , unloading transportation, labour charges, consumables, lubricants , tools , tackles , jigs and implements etc. complete as required including refixing, realignment, ensuring the design / required parameters etc. complete as required (Damaged Bearing need not be returned to AAI. Rate shall be quoted accordingly) b) 25.00 HP Jockey Pump
Replacing both the bearings of motor of following capacity and application including decoupling from the load side, dismantling from the foundation , loading , unloading transportation, labour charges, consumables, lubricants , tools , tackles , jigs and implements etc. complete as required including refixing, realignment, ensuring the design / required parameters etc. complete as required (Damaged Bearing need not be returned to AAI. Rate shall be quoted accordingly) c) 75.00 HP Main Fire Pump
Replacing both the bearings of motor of following capacity and application including decoupling from the load side, dismantling from the foundation , loading , unloading transportation, labour charges, consumables, lubricants , tools , tackles , jigs and implements etc. complete as required including refixing, realignment, ensuring the design / required parameters etc. complete as required (Damaged Bearing need not be returned to AAI. Rate shall be quoted accordingly) d) 120.00 HP Main Fire Pump
Replacing the damaged rubber bush of following capacity and application pump motor sets as listed below including labour charges for dismantling the coupling, refixing the coupling , ensuring proper shaft alignment etc. as required a) 12.50 HP Jockey Pump
Replacing the damaged rubber bush of following capacity and application pump motor sets as listed below including labour charges for dismantling the coupling, refixing the coupling , ensuring proper shaft alignment etc. as required b) 25.00 HP Jockey Pump
Replacing the damaged rubber bush of following capacity and application pump motor sets as listed below including labour charges for dismantling the coupling, refixing the coupling , ensuring proper shaft alignment etc. as required c) 75.00 HP Main Fire Pump
Replacing the damaged rubber bush of following capacity and application pump motor sets as listed below including labour charges for dismantling the coupling, refixing the coupling , ensuring proper shaft alignment etc. as required d) 120.00 HP Main Fire Pump
Lifting and lowering of submersible pump along with the installed pipe from bore well ( up to 400 feet max) including dismantling the defective submersible motor, pump set and installing the serviceable motor pump set with the existing pipe, arranging T&P and necessary consumables etc. complete as required a) Submersible pumps installed with HDPE/PVC Pipe
Lifting and lowering of submersible pump along with the installed pipe from bore well ( up to 400 feet max) including dismantling the defective submersible motor, pump set and installing the serviceable motor pump set with the existing pipe, arranging T&P and necessary consumables etc. complete as required b)Submersible pumps installed with GI pipe with Sockets/ Flanges
Lifting of defective submersible motor pump set from open well/sump and dismantling the same and installing the serviceable motor pump set arranging T&P and necessary consumables including lifting and lowering into sump/open well etc. complete as required (Serviceable Motor will be provided by AAI).
Rewinding of following type of motors with enamelled/Teflon coated copper wire varnishing & baking along with gunmetal bushes, thrust bearing etc. and including to & fro transportation etc. complete as required (Burnt copper need not be returned to AAI. Rate shall be quoted accordingly) Submersible Motor (Bore well) Above 2 HP and up to 5 HP
Rewinding of following type of motors with enamelled/Teflon coated copper wire varnishing & baking along with gunmetal bushes, thrust bearing etc. and including to & fro transportation etc. complete as required (Burnt copper need not be returned to AAI. Rate shall be quoted accordingly) Submersible Motor (Bore well) Above 5 HP and up to 10 HP
Rewinding of following type of motors with enamelled/Teflon coated copper wire varnishing & baking along with gunmetal bushes, thrust bearing etc. and including to&fro transportation etc. complete as required (Burnt copper need not be returned to AAI. Rate shall be quoted accordingly) Submersible Motor (Open well/sump) Below 2 HP
Rewinding of following type of motors with enamelled/Teflon coated copper wire varnishing & baking along with gunmetal bushes, thrust bearing etc. and including to&fro transportation etc. complete as required (Burnt copper need not be returned to AAI. Rate shall be quoted accordingly) Submersible Motor (Open well/sump) Above 2 HP and up to 5 HP
Rewinding of following type of motors with enamelled/Teflon coated copper wire varnishing & baking along with gunmetal bushes, thrust bearing etc. and including to&fro transportation etc. complete as required (Burnt copper need not be returned to AAI. Rate shall be quoted accordingly) Submersible Motor (Open well/sump) Above 5 HP and up to 10 HP
Rewinding of following type of motors with enamelled/Teflon coated copper wire varnishing & baking along with gunmetal bushes, thrust bearing etc. and including to&fro transportation etc. complete as required (Burnt copper need not be returned to AAI. Rate shall be quoted accordingly) Submersible Motor (Open well/sump) Above 10 HP and up to 15 HP
Rewinding of following type of motors with enamelled/Teflon coated copper wire varnishing & baking along with gunmetal bushes, thrust bearing etc. and including to&fro transportation etc. complete as required (Burnt copper need not be returned to AAI. Rate shall be quoted accordingly) Submersible Motor (Open well/sump) Above 15 HP and up to 17.5 HP
Rewinding of following type of motors with enamelled/Teflon coated copper wire varnishing & baking along with gunmetal bushes, thrust bearing etc. and including to&fro transportation etc. complete as required (Burnt copper need not be returned to AAI. Rate shall be quoted accordingly) Monoblock Pump Motor Below 2 HP
Rewinding of following type of motors with enamelled/Teflon coated copper wire varnishing & baking along with gunmetal bushes, thrust bearing etc. and including to&fro transportation etc. complete as required (Burnt copper need not be returned to AAI. Rate shall be quoted accordingly) Monoblock Pump Motor Above 2 HP and up to 5 HP
Rewinding of following type of motors with enamelled/Teflon coated copper wire varnishing & baking along with gunmetal bushes, thrust bearing etc. and including to&fro transportation etc. complete as required (Burnt copper need not be returned to AAI. Rate shall be quoted accordingly) Monoblock Pump Motor Above 5 HP and up to 10 HP
Rewinding of following type of motors with enamelled/Teflon coated copper wire varnishing & baking along with gunmetal bushes, thrust bearing etc. and including to&fro transportation etc. complete as required (Burnt copper need not be returned to AAI. Rate shall be quoted accordingly) Monoblock Pump Motor Above 10 HP and up to 15 HP
Servicing of the following capacity submersible (Open well/Bore well/sump) pumps including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation. Upto 2 HP Thrust bearing
Servicing of the following capacity ubmersible (Open well/Bore well/sump) pumps including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation. Upto 2 HP Bushes
Servicing of the following capacity Submersible Motor (Open well/Bore well/sump) pump including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation. Upto 2 HP Shaft sleeve
Servicing of the following capacity Submersible Motor (Open well/Bore well/sump) pump including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation. Upto 2 HP Thrust plate
Servicing of the following capacity submersible (Open well/Bore well/sump) pumps including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation. Above 2 HP and up to 5 HP Thrust bearing
Servicing of the following capacity ubmersible (Open well/Bore well/sump) pumps including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation. Above 2 HP and up to 5 HP Bushes
Servicing of the following capacity Submersible Motor (Open well/Bore well/sump) pump including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation. Above 2 HP and up to 5 HP Shaft sleeve
Servicing of the following capacity Submersible Motor (Open well/Bore well/sump) pump including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation. Above 2 HP and up to 5 HP Thrust plate
Servicing of the following capacity Submersible Motor (Open well/Bore well/sump) pumps including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation. Above 5 HP and up to 10 HP Thrust bearing
Servicing of the following capacity Submersible Motor (Open well/Bore well/sump) pumps including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation. Above 5 HP and up to 10 HP Bushes
Servicing of the following capacity Submersible Motor (Open well/Bore well/sump) pumps including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation. Above 5 HP and up to 10 HP Shaft sleeve
Servicing of the following capacity submersible/mono block pumps including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation. Submersible Motor (Open well/Bore well/sump) Above 5 HP and up to 10 HP Thrust plate
Servicing of the following capacity Submersible Motor (Open well/Bore well/sump) pumps including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation. Above 10 HP and up to 15 HP Thrust bearing
Servicing of the following capacity Submersible Motor (Open well/Bore well/sump) pumps including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation. Above 10 HP and up to 15 HP Bushes
Servicing of the following capacity Submersible Motor (Open well/Bore well/sump) pumps including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation. Above 10 HP and up to 15 HP Shaft sleeve
Servicing of the following capacity Submersible Motor (Open well/Bore well/sump) pumps including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation. Above 10 HP and up to 15 HP Thrust plate
Servicing of the following capacity Submersible Motor (Open well/Bore well/sump) pumps including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation. Above 15 HP and up to 20 HP Thrust bearing
Servicing of the following capacity Submersible Motor (Open well/Bore well/sump) pumps including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation. Above 15 HP and up to 20 HP Bushes
Servicing of the following capacity Submersible Motor (Open well/Bore well/sump) pumps including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation. Above 15 HP and up to 20 HP Shaft sleeve
Servicing of the following capacity Submersible Motor (Open well/Bore well/sump) pumps including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation. Above 15 HP and up to 20 HP Thrust plate
Servicing of the following capacity Monoblock Pump Motor including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation. Below 2HP Bearing
Servicing of the following capacity Monoblock Pump Motor including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation. Below 2HP Bushes
Servicing of the following capacity Monoblock Pump Motor including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation. Below 2HP Shaft sleeve
Servicing of the following capacity Monoblock Pump Motor including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation. Above 2 HP and up to 5 HP Bearing
Servicing of the following capacity Monoblock Pump Motor including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation. Above 2 HP and up to 5 HP Bushes
Servicing of the following capacity Monoblock Pump Motor including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation. Above 2 HP and up to 5 HP Shaft sleeve
Servicing of the following capacity Monoblock Pump Motor including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation. Above 5 HP and up to 10 HP Bearing
Servicing of the following capacity Monoblock Pump Motor including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation. Above 5 HP and up to 10 HP Bushes
Servicing of the following capacity Monoblock Pump Motor including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation. Above 5 HP and up to 10 HP Shaft sleeve
Servicing of the following capacity Monoblock Pump Motor including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation. Above 10 HP Bearing
Servicing of the following capacity Monoblock Pump Motor including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation. Above 10 HP Bushes
Servicing of the following capacity Monoblock Pump Motor including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation. Above 10 HP Shaft sleeve
Repairing of Soft starter (Make: L&T, Model : EMX3-0145B-V4-C1-H) used for fire fighting main electric pump, including repair/ replacement of any components like SCR, control card, display etc. including testing and commissioning of the same. The cost shall include to and fro transport of the soft starter to the service location of the specialized agency/L&T authorized centre as the case may be.
Rewinding of following type of Air Circulators/ceiling fans/exhaust fans with enamelled copper wire, baking, varnishing, overhauling, greasing, refitting of motor etc. and including to & fro transportation etc. complete as required (Burnt copper need not be returned to AAI. Rate shall be quoted accordingly) 600mm. Sweep air circulators
Rewinding of following type of Air Circulators/ceiling fans/exhaust fans with enamelled copper wire, baking, varnishing, overhauling, greasing, refitting of motor etc. and including to & fro transportation etc. complete as required (Burnt copper need not be returned to AAI. Rate shall be quoted accordingly) 450mm. Sweep air circulators
Rewinding of following type of Air Circulators/ceiling fans/exhaust fans with enamelled copper wire, baking, varnishing, overhauling, greasing, refitting of motor etc. and including to & fro transportation etc. complete as required (Burnt copper need not be returned to AAI. Rate shall be quoted accordingly) 300/380mm. Sweep Exhaust fan 900rpm heavy duty
Rewinding of following type of Air Circulators/ceiling fans/exhaust fans with enamelled copper wire, baking, varnishing, overhauling, greasing, refitting of motor etc. and including to & fro transportation etc. complete as required (Burnt copper need not be returned to AAI. Rate shall be quoted accordingly) 300mm. Sweep Exhaust fan 1400 rpm light duty
Rewinding of following type of Air Circulators/ceiling fans/exhaust fans with enamelled copper wire, baking, varnishing, overhauling, greasing, refitting of motor etc. and including to & fro transportation etc. complete as required (Burnt copper need not be returned to AAI. Rate shall be quoted accordingly) 1200mm. Sweep ceiling fan
Rewinding of following type of Air Circulators/ceiling fans/exhaust fans with enamelled copper wire, baking, varnishing, overhauling, greasing, refitting of motor etc. and including to & fro transportation etc. complete as required (Burnt copper need not be returned to AAI. Rate shall be quoted accordingly) 400 mm. sweep wall mounting fan
Rewinding of following type of Air Circulators/ceiling fans/exhaust fans with enamelled copper wire, baking, varnishing, overhauling, greasing, refitting of motor etc. and including to & fro transportation etc. complete as required (Burnt copper need not be returned to AAI. Rate shall be quoted accordingly) 400 mm. sweep pedestal fan
ABHISHEK INTEGRATIONS LIMITED
Blue Star Limited
CHENNAI ENGINEERING SERVICES
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .