REPAIR REPLACEMENT OF ELECTRIC WIRING IN OTM ACCN AND REPAIRS/MAINTENANCE OF COOLING APPLIANCES DESERT COOLERS WATER COOLERS REFRIGERATOR AIR CONDITIONERS AND DEEP FREEZER AT MIL STN GANDHINAGAR
2022_MES_522449_2
GE(A)/GNR/TOKEN/01 of 2022-23
Open Tender
Civil Works
Item Rate
180 days
GE ARMY GANDHINAGAR
As per tender documents
6 documents required · 6 mandatory
₹500
GE ARMY GANDHINAGAR
₹48,000
Yes
6 Aug 2022
1 Jun 2022
17 Jun 2022
1 Jun 2022
15 Jun 2022
3 Jun 2022
1 Jun 2022 - 3 Jun 2022
Amount
Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete, including fixture and fitting such as as switches, ceiling roses, pendants, regulators, sockets, etc excluing light fittings etc, removing materials to store for keeping in safe custudy or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surface of walls, ceiling, floor etc to match with the existing surface.
M&L for wiring with and including multistranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number drawn in and including medium grade PVC casing and capping double lock type 32mm in size, fire resistant, ISI marked including with its fittings and fixtures such as tees, bends, elbows, junction boxes, etc. including multistranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number as continuity earth wire and including pressed steel sunken concealed terminal box with 3mm thick industrial laminated sheet cover for mounting switches, sockets and fan regulators etc. complete all as specified and directed for the following :-
(a) One light/fan point controlled by one switch
(b) One multi purpose socket 5 Amps, Independent board.
(c) One multi purpose socket 5 Amps, on the same board.
M&L for wiring with and including multistranded copper conductor 2.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number drawn in and including medium grade PVC casing and capping double lock type 32mm in size, fire resistant, ISI marked including with its fittings and fixtures such as tees, bends, elbows, junction boxes, etc. including multistranded copper conductor 2.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number as continuity earth wire and including pressed steel sunken concealed terminal box with 3mm thick industrial laminated sheet cover for mounting switches, sockets and fan regulators etc. for one 3 pin, 15 Amps socket outlet point on independent board complete all as specified and directed.
M&L for wiring with and including multi stranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLS cable, 1100 volts grade, ISI marked with valid CML number, drawing through in and including, rigid non metallic, PVC concealed conduit of 20mm bore and including cutting chases for conduits and sinkings for boxes, its accessories & including with multi stranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLS cable, 1100 volts grade, ISI marked with valid CML number as continuity earth wire terminating with provision sunken concealed terminal boxes complete all as specified and directed for the following :-
(a) One light/fan point controlled by one switch
(b) One multi purpose socket 5 Amps, Independent board.
(c) One multi purpose socket 5 Amps, on the same board.
M&L for wiring with and including multi stranded copper conductor 2.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLS cable, 1100 volts grade, ISI marked with valid CML number, drawing through in and including medium grade, rigid non metallic, PVC concealed conduit of 20mm bore and including cutting chases for conduits and sunken for boxes, its accessories & including with multi stranded copper conductor 2.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLS cable, green colour, 1100 volts grade, ISI marked with valid CML number as continuity earth wire terminating with provision of sunken concealed terminal boxes complete all as specified and directed.
S&F, in repair, lamp holder, insulated body with back plate for batten fittings complete all as specified and directed.
S&F, in repair, switch piano, flush button single pole, one way 5 Amps complete all as specified and directed.
S&F, in repair, switch piano flush button single pole, one way 15 Amps complete all as specified and directed.
S&F, in repair, socket outlet multipurpose, 3 pin, 5 &15 Amps flush type complete all as specified and directed.
S&F, in repair, socket outlet 2 in1, 3 pin, 5 Amps, flush type complete all as specified and directed.
S&F in repair switch socket combination 2 in 1, 3 pin, 5 & 15 Amps flush type complete all as specified and directed.
S&F, in repair, switch socket combination 2 in 1, 3 pin, 5 Amps flush type complete all as specified and directed.
S&F, in repair, Ceiling rose, PVC/poly carbonate, isolated body three terminals, complete all as specified and directed
S&F, in repair, Distribution Board SPN 12 way, 240 volts, factory made powder coated, double door with neutral and earth link, suitable for fixing MCB,s complete including connecting all as specified and directed.
S&F, in repair, Distribution Board SPN 8 way, 240 volts, factory made powder coated, double door with neutral and earth link, suitable for fixing MCB,s complete including connecting all as specified and directed.
S & F in repair Distribution Board Power line VTPN , 4 way, 415 volts, factory made powder coated, double door with neutral and earth link, suitable for 4 pole MCCB 63 Amps for incoming supply and 12 Nos single pole MCBs 6 to 32 Amp for out going supply complete all as specified and directed.
M&L for ceiling fan regulators, Electronic step type type, AC, 230 Volts complete all as specified and directed.
S&F, in repair, MCB’s single pole, 6 to 32 Amps 240 volts with ‘C’ curve,10KA, fixed in sheet metal board complete including connecting.
S&F, in repair, MCB’s SPN 32 Amps 240 volts with ‘C’ curve, fixed in sheet metal board complete including connecting.
S&F, in repair, MCCB Three pole and neutral 10KA, 63 Amps, 415Volts. complete all as specified and directed.
S&F, in repairs, LED light fitting, 1x20W, 220 V AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed
S&F, in repair, LED light fitting 1x10 W bulk head luminaries including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size
S&F, in repair, LED fitting ceiling mounted recessed 2X2 luminaire 36 watt and glare free soft illumination complete all as specified and directed.
S&F, in repair, LED type Bldg security light fittings, IP-66, 25W, Pressure die cast aluminium housing with toughned glass & individual LEDs with secondary optics including taking out old unsv fitting of any type complete all specified and directed.
M&L in replacement sub-main wiring with 2 single core 4 Sqmm PVC insulated, unsheathed, 1100Volts grade, copper multi stranded conductor drawn in PVC casing and capping ISI marked including with its fittings and fixtures such as tees, bends, elbows, junction boxes, etc. including multistranded copper conductor 4.0 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number as continuity earth wire drawn through and connected to main switch/ DB and testing on completion. Note: (i). 2 run of main conductor and one run of earth conductor shall be measured as one length.
S&F, in repair, LED Post top lantern made of cast aluminium with decorative opal poly carbonate diffuser with protection IP-65 with 45 W LED (Warm white) complete with electrical connections.
M&L for earthing and testing complete, in repair, with galvanized iron earth plate electrode 60 cm x 60cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 M below normal ground level with top edge plate at a depth not less than 1.5M below normal ground level connected to and including earth lead GI wire 4.0 mm dia, by means of bolts and nuts, check nuts and washers etc., made of GI and connected to panel/distribution board and earthing test point and earth dolly all as shown in elect plate No.3 of SSR Part-1 including necessary earth work,excavation PCC chamber cover with handle (PCC 1:2:4) incl 20mm dia GI pipe of medium grade for watering and 15mm dia GI pipe of light grade for protection of earthing lead, wire mesh, funnel, charcoal dust,common salt,copper lugs etc all as specified and directed .
S&F, in repair, integral decorative LED Bollard fitting with IP-65 protection cylindercial shape integral decorative LED Bollard with opal acrylic diffuser, 9W LED (Warm white) complete with electrical connections.
S & F in repair LED strip light 5watt/meter with driver (5 m each)as per cat part No-LST20BL of CG make or make approved all as specified and directed .
S&F, in repair decorative wall mounting, fixture in durable plastic body and designer mesh in gold finish suitable for 9W LED lamp B22 Base complete all as specified and directed.
S&F, in repairs, surface mounted, LED bedside light of 3 W in Black colour (WW), 240V, 50 Hz, and connecting up all as specified and directed.
S&F, in repairs, mirror light 12 watt , 240V, 50Hz and connecting up all as specified and directed.
S&F, in repair, 24 Watt, LED light of recess cum surface panel solution to provide variable cut out size mounting round type/square type complete with all attachment complete all as specified and directed.
Maintenance & Services of Split AC/Window AC, fixed in position at site, Cleaning of filter, dust with blower motor cleaning of condecing unit and evaporate unit complete all as specified and directed.
Repair and Maintenance of flame proof split AC 1.5 ton with dismentling of assembly cleaning the body with air blower, replacement of electrical contactor set, cleaning of filter for internal unit, replacement insulation for cooling pipe, checking of electrical connection and tightning of the same and testing complete all as specified and directed.
S&F, in repair, fan motor for condencing unit of Split AC of 1.5 TR of the same as of the original equipment manufacturer complete all as specified and directed.
S&F, in repair, PCB for remot operation of internal unit of Split AC of the same as of the original equipment manufacturer complete all as specified and directed.
S&F, in repair, internal blower motor for internal unit electrically operated 230 V AC supply of the same original equipment manufacturer of the Split AC complete all as specified and directed.
S&F, in repair, internal blower unit & cooling coil for 1.5/2.0 TR Split AC complete all as specified and directed.
S&F, in repair, sealed unit compressor (replaced with original company new compressor of same make as per existing), suitable for working on single phase, 50 HZ AC supply in window/split type A/C of appropriate make including making necessary refrigerent pipe connection, electric connection, checking of leakage and testing complete all as specified and directed for 1.5 TR Capacity, complete all as specified and directed.
S&F, in repair, sealed unit compressor (replaced with original company new compressor of same make as per existing), suitable for working on single phase, 50 HZ AC supply in window/split type A/C of appropriate make including making necessary refrigerent pipe connection, electric connection, checking of leakage and testing complete all as specified and directed for 2 TR Capacity, complete all as specified and directed.
S&F, in repair, sealed unit compressor (replaced with original company new compressor of same make as per existing ) suitable for working on single phase 50 Hz AC supply in water cooler of 40/80 Ltrs capacity including making connection and brazing of necessary refrigerent pipe, electric connections and testing for leakproof complete all as specified and directed.
S&F, in repair, sealed unit compressor (replaced with original company new compressor of same make as per existing ) suitable for working on single phase 50 Hz AC supply in refrigerator 1/8 HP (165 to 210 Ltrs) capacity including making connection and brazing of necessary refrigerent pipe, electric connections and testing for leakproof complete all as specified and directed.
S&F, in repair, sealed unit compressor (replaced with original company new compressor of same make as per existing ) suitable for working on single phase 50 Hz AC supply in refrigerator 1/6 HP (265 to 310 Ltrs) capacity including making connection and brazing of necessary refrigerent pipe, electric connections and testing for leakproof complete all as specified and directed.
S&F, in repair, sealed unit compressor (replaced with original company new compressor of same make as per existing) suitable for working on single phase 50 Hz AC supply in deep freezer 310/320 Ltrs capacity including making connection and brazing of necessary refrigerent pipe, electric connections and testing for leakproof complete all as specified and directed.
M&L, in repair, starting relay of window/Split type A/C, 1.5 to 2 TR capacity including making necessary electric connections complete all as specified and directed.
M&L, in repair, starting relay of water coolers 40/80 Ltr capacity including making necessary electric connections complete all as specified and directed.
M&L, in repair, starting relay of Refrigerator 1/8 to 1/6 HP capacity including making necessary electric connections complete all as specified and directed.
S&F, in repair, overload protector of A/C 1.5 to 2 TR complete all as specified and directed.
S&F, in repair, overload protector of Water coolers up to 120 Ltr complete all as specified and directed.
S&F, in repair, overload protector of Refrigerator and Deep freezer 165 Ltr to 310 Ltr complete all as specified and directed.
S&F, in repair, Thermostate suitable for A/C 1.5 to 2 TR complete all as specified and directed.
S&F, in repair, Thermostate suitable for Water coolers up to 120 Ltrs complete all as specified and directed.
S&F, in repair, Thermostate suitable for Refrigerators & deep freezer up to 310 Ltrs complete all as specified and directed.
S&F, in repair, Starting capacitor 230 Volt, 100-150MFD suitable for AC's complete all as specified and directed.
S&F, in repair, Starting capacitor 230 Volt, 80-100MFD suitable for AC's complete all as specified and directed.
S&F, in repair, Running capacitor, 230 Volts, SP, 6.3 MFD complete all as specified and directed.
S&F, in repair, Running capacitor, 230 Volts, SP, 36/45 MFD complete all as specified and directed.
M&L for refrigerent charging with R-22/R-134 for window/split type A/C of capacity 1.5 & 2 TR and making necessary copper tubing connection for refrigerent line, soldering, brassing of leakage point complete all as specified and directed.
M&L for refrigerent charging with R-22/R-134 for Water Cooler of capacity 40/80 Ltr and making necessary copper tubing connection for refrigerent line, soldering, brassing of leakage point complete all as specified and directed.
M&L for refrigerent charging with R-22/R-134 for Deep Freezer of capacity 165 Ltr to 320 Ltr and making necessary copper tubing connection for refrigerent line, soldering, brassing of leakage point complete all as specified and directed.
S&F, in replacement, bottom water tank of desert cooler of size 750 x 750 x 200mm fabricated out of 18 gauge PGI sheet including nuts bolts and washers etc complete all as specified and directed.
S&F, in replacement, side supporting columns made out of 20 Gauges PGI sheet of size 80 x 80 x 800mm including necessary nut & bolts, etc. including painting to match with existing desert cooler complete all as specified and directed.
S&F, in replacement, push cock, 15mm bore made of brass chromium plated self closing, vertical type complete all as specified and directed.
S&F, in replacement connectors made of brass with chromium plated suitable for water cooler having cooling capacity 40 Ltr/Hr complete all as specified and directed.
S&F, in replacement fan blade for condensing fan motor suitble for water cooler having cooling capacity 40/60 Ltr/Hr complete all as specified and directed.
S&F, in replacement, condenser unit complete suitable for 40 Ltr/Hr capacity water cooler including gas charging, fulshing out the system, brazing, welding and jointing the suction reed and discharge reed complete all as per direction of Engineer-in-Charge complete all as specified and directed.
S&F, in replacement, side panel made out of PGI Sheet including handles including painting to match with the existing desert cooler complete.
S&F, in replacement, top cover made out of PGI Sheet with suitable handles including painting to match with the existing desert cooler complete all as specified and directed.
S&F, in repairs, water lift submerssible pump (ISI Marked) suitable to operate on 230V AC supply of desert cooler and connecting electically, complete all as specified and directed.
S&F, in repair, fan motor (ISI Marked), 1/10 HP, 230 volt single phase of existing desert cooler with fixing clamps, complete all as specified and directed
S&F, in repair, wood wool pads, superior quality, suitable size of existing desert cooler, complete all as specified and directed
S&F, desert cooler fan blade suitable for 4000/5000 cum desert cooler motor complete all as specified and directed.
S&F, in replacment PVC pipe 15mm dia heavy duty for suitable for desert cooler pump complete all as specified and directed.
S&F, in repair, Candles of existing water purifier at the inlet of the water cooler of any capacity complete all as specified and directed.
ARTI CONSTRUCTION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .